975 resultados para pupil size


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To use a large wavefront database of a clinical population to investigate relationships between refractions and higher order aberrations and between aberrations of right and left eyes. Methods: Third and fourth-order aberration coefficients and higher-order root-mean-squared aberrations (HO RMS), scaled to a pupil size of 4.5 mm diameter, were analysed in a population of about 24,000 patients from Carl Zeiss Vision's European wavefront database. Correlations were determined between the aberrations and the variables of refraction, near addition and cylinder. Results: Most aberration coefficients were significantly dependent upon these variables, but the proportions of aberrations that could be explained by these factors were less than 2% except for spherical aberration (12%), horizontal coma (9%) and HO RMS (7%). Near addition was the major contributor for horizontal coma (8.5% out of 9.5%) and spherical equivalent was the major contributor for spherical aberration (7.7% out of 11.6%). Interocular correlations were highly significant for all aberration coefficients, varying between 0.16 and 0.81. Anisometropia was a variable of significance for three aberrations (vertical coma, secondary astigmatism and tetrafoil), but little importance can be placed on this because of the small proportions of aberrations that can be explained by refraction (all less than 1.0 %). Conclusions: Most third- and fourth-order aberration coefficients were significantly dependent upon spherical equivalent, near addition and cylinder, but only horizontal coma (9%) and spherical aberration (12%) showed dependencies of greater than 2%. Interocular correlations were highly significant for all aberration coefficients, but anisometropia had little influence on aberration coefficients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study is to determine visual performance in water, including the influence of pupil size. The water en-vironment was simulated by placing a goggle filled with saline in front of eyes, with apertures placed at the front of the goggle. Correction factors were determined for the different magnification under this condition in order to to estimate vision in water. Experiments were conducted on letter visual acuity (7 participants), grating resolution (8 participants), and grating contrast sensitivity (1 participant). For letter acuity, mean loss in vision in water, compared to corrected vision in air, varied between 1.1 log minutes of arc resolution (logMAR) for a 1mm aperture to 2.2 logMAR for a 7mm aperture. The vision in minutes of arc was described well by a linear relationship with pupil size. For grating acuity, mean loss varied between 1.1 logMAR for a 2mm aperture to 1.2 logMAR for a 6mm aperture. Contrast sensitivity for a 2mm aperture dete-riorated as spatial frequency increased, with 2 log unit loss by 3 cycles/degree. Superimposed on this deterioration were depressions (notches) in sensitivity, with the first three notches occurring at 0.45, 0.8 and 1.3 cycles/degree with esti-mates for water of 0.39, 0.70 and 1.13 cycles/degree. In conclusion, vision in water is poor. It becomes worse as pupil size increases, but the effects are much more marked for letter targets than for grating targets.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To determine visual performance in water, including the influence of pupil size. Method: The water environment was simulated by placing a goggle filled with saline in front of eyes, with apertures placed at the front of the goggle. Correction factors were determined for the different magnification under this condition to estimate vision in water. Experiments were conducted on letter visual acuity (7 participants), grating resolution (8 participants), and grating contrast sensitivity (1 participant). Results: For letter acuity, mean loss in vision in water, compared to corrected vision in air, varied between 1.1 log minutes of arc resolution (logMAR) for a 1mm aperture to 2.2 logMAR for a 7mm aperture. The vision in minutes of arc was described well by a linear relationship with pupil size. For grating acuity, mean loss varied between 1.1 logMAR for a 2mm aperture to 1.2 logMAR for a 6mm aperture. Contrast sensitivity for a 2mm aperture deteriorated as spatial frequency increased, with 2 log unit loss by 3 cycles/degree. Superimposed on this deterioration were depressions (notches) in sensitivity, with the first three notches occurring at 0.45, 0.8 and 1.3 cycles/degree and with estimates for water of 0.39, 0.70 and 1.13 cycles/degree. Conclusion: Vision in water is poor. It becomes worse as pupil size increases, but the effects are much more marked for letter targets than for grating targets.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis investigates the use of fusion techniques and mathematical modelling to increase the robustness of iris recognition systems against iris image quality degradation, pupil size changes and partial occlusion. The proposed techniques improve recognition accuracy and enhance security. They can be further developed for better iris recognition in less constrained environments that do not require user cooperation. A framework to analyse the consistency of different regions of the iris is also developed. This can be applied to improve recognition systems using partial iris images, and cancelable biometric signatures or biometric based cryptography for privacy protection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The richness of the iris texture and its variability across individuals make it a useful biometric trait for personal authentication. One of the key stages in classical iris recognition is the normalization process, where the annular iris region is mapped to a dimensionless pseudo-polar coordinate system. This process results in a rectangular structure that can be used to compensate for differences in scale and variations in pupil size. Most iris recognition methods in the literature adopt linear sampling in the radial and angular directions when performing iris normalization. In this paper, a biomechanical model of the iris is used to define a novel nonlinear normalization scheme that improves iris recognition accuracy under different degrees of pupil dilation. The proposed biomechanical model is used to predict the radial displacement of any point in the iris at a given dilation level, and this information is incorporated in the normalization process. Experimental results on the WVU pupil light reflex database (WVU-PLR) indicate the efficacy of the proposed technique, especially when matching iris images with large differences in pupil size.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This is a comprehensive study of a large range of biometric and optical parameters in people with type 1 diabetes. The parameters of 74 people with type 1 diabetes and an age matched control group were assessed. Most of the people with diabetes had low levels of neuropathy, retinopathy and nephropathy. Marginal or no significant differences were found between groups for corneal shape, corneal thickness, pupil size, and pupil decentrations. Relative to the control group, the diabetes group demonstrated smaller anterior chamber depths, more curved lenses, greater lens thickness and lower lens equivalent refractive index. While the optics of diabetic eyes make them appear as older eyes than those of people of the same age without diabetes, the differences did not increase significantly with age. Age-related changes in the optics of the eyes of people with diabetes need not be accelerated if the diabetes is well controlled.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

建立了一种基于图像处理的快速瞳孔直径检测算法,运用此算法提取了反映阿片类药物成瘾人员与正常人对瞳孔光反射变化差异的3个特征值:绝对收缩幅度(absolute amplitude of contraction,AAC)、相对收缩幅度(relative amplitude of contraction,RAC)和收缩斜率(SCV,slope of contraction velocity);分别研究了成瘾、性别、近视、年龄、睡眠剥夺等因素对于这3个特征值的影响。不同性别、近视人员、睡眠剥夺人员与正常人之间的3个特征值均无显著差异,成瘾人员与之对比均显著减小。老年人相对于正常青年人,3个特征值都明显减小;与成瘾人员相比,仅在RAC值上有显著差异。结果表明,阿片类药物成瘾人员除了与正常人外,也与其他具有潜在影响瞳孔变化因素的非阿片成瘾人员在瞳孔对光反射的特征值上具有显著差异。该研究的实验数据为进一步建立基于检测瞳孔对光反射其直径发生变化的方法来快速、非接触地鉴别出阿片类药物成瘾人员提供了可靠的依据。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: In patients with outer retinal degeneration, a differential pupil response to long wavelength (red) versus short wavelength (blue) light stimulation has been previously observed. The goal of this study was to quantify differences in the pupillary re-dilation following exposure to red versus blue light in patients with outer retinal disease and compare them with patients with optic neuropathy and with healthy subjects. DESIGN: Prospective comparative cohort study. PARTICIPANTS: Twenty-three patients with outer retinal disease, 13 patients with optic neuropathy and 14 normal subjects. METHODS: Subjects were tested using continuous red and blue light stimulation at three intensities (1, 10 and 100 cd/m2) for 13 s per intensity. Pupillary re-dilation dynamics following the brightest intensity was analysed and compared between the three groups. MAIN OUTCOME MEASURES: The parameters of pupil re-dilation used in this study were: time to recover 90% of baseline size; mean pupil size at early and late phases of re-dilation; and differential re-dilation time for blue versus red light. RESULTS: Patients with outer retinal disease showed a pupil that tended to stay smaller after light termination and thus had a longer time to recovery. The differential re-dilation time was significantly greater in patients with outer retinal disease (median = 28.0 s, P < 0.0001) compared with controls and patients with optic neuropathy. CONCLUSIONS: A differential response of pupil re-dilation following red versus blue light stimulation is present in patients with outer retinal disease but is not found in normal eyes or among patients with visual loss from optic neuropathy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The current study was an exploration of why some novices are more successful than their peers when learning from the Internet by examining the relations among time spent with relevant information and changes in invested mental effort during Internet navigations as well as achievement. Navigation behaviours and learner characteristics were investigated as predictors of time spent with relevant information and changes in mental effort. Undergraduates (N = 85, Mage = 20 years, 5 months) searched the Internet for information corresponding to a low knowledge topic for 20 min while their eye gaze and pupil size were recorded. Pupil diameter was used as an objective, continuous measure of mental effort. Participants also completed questionnaires or computer tasks pertaining to s e l f-regulated learning characteristics (general intrinsic goal orientation and effort regulation) and cognitive factors (working memory control, distractibility and cognitive style). All analyses controlled for general mental ability, reading comprehension, topic and Internet knowledge, and overall motivation. A greater proportion of time spent with relevant information predicted higher scores on an achievement test. Interestingly, time spent with relevant information partially mediated the positive relation between the frequency of increases in invested mental effort and achievement. Surprisingly, intrinsic goal orientation was negatively related to time spent with relevant information and effort regulation was negatively related to the frequency of increases in invested mental effort. These findings have implications for supports when novices guide their own learning, especially when using the Internet.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose. Hyperopic retinal defocus (blur) is thought to be a cause of myopia. If the retinal image of an object is not clearly focused, the resulting blur is thought to cause the continuing lengthening of the eyeball during development causing a permanent refractive error. Both lag of accommodation, especially for near targets, and greater variability in the accommodative response, have been suggested as causes of increased hyperopic retinal blur. Previous studies of lag of accommodation show variable findings. In comparison, greater variability in the accommodative response has been demonstrated in adults with late onset myopia but has not been tested in children. This study looked at the lag and variability of accommodation in children with early onset myopia. Methods. Twenty-one myopic and 18 emmetropic children were tested. Dynamic measures of accommodation and pupil size were made using eccentric photorefraction (Power Refractor) while children viewed targets set at three different accommodative demands (0.25, 2, and 4 D). Results. We found no difference in accommodative lag between groups. However, the accommodative response was more variable in the myopes than emmetropes when viewing both the near (4 D) and far (0.25 D) targets. Since pupil size and variability also varied, we analyzed the data to determine whether this could account for the inter-group differences in accommodation variability. Variation in these factors was not found to be sufficient to explain these differences. Changes in the accommodative response variability with target distance were similar to patterns reported previously in adult emmetropes and late onset myopes. Conclusions. Children with early onset myopia demonstrate greater accommodative variability than emmetropic children, and have similar patterns of response to adult late onset myopes. This increased variability could result in an increase in retinal blur for both near and far targets. The role of accommodative variability in the etiology of myopia is discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The challenge of moving past the classic Window Icons Menus Pointer (WIMP) interface, i.e. by turning it ‘3D’, has resulted in much research and development. To evaluate the impact of 3D on the ‘finding a target picture in a folder’ task, we built a 3D WIMP interface that allowed the systematic manipulation of visual depth, visual aides, semantic category distribution of targets versus non-targets; and the detailed measurement of lower-level stimuli features. Across two separate experiments, one large sample web-based experiment, to understand associations, and one controlled lab environment, using eye tracking to understand user focus, we investigated how visual depth, use of visual aides, use of semantic categories, and lower-level stimuli features (i.e. contrast, colour and luminance) impact how successfully participants are able to search for, and detect, the target image. Moreover in the lab-based experiment, we captured pupillometry measurements to allow consideration of the influence of increasing cognitive load as a result of either an increasing number of items on the screen, or due to the inclusion of visual depth. Our findings showed that increasing the visible layers of depth, and inclusion of converging lines, did not impact target detection times, errors, or failure rates. Low-level features, including colour, luminance, and number of edges, did correlate with differences in target detection times, errors, and failure rates. Our results also revealed that semantic sorting algorithms significantly decreased target detection times. Increased semantic contrasts between a target and its neighbours correlated with an increase in detection errors. Finally, pupillometric data did not provide evidence of any correlation between the number of visible layers of depth and pupil size, however, using structural equation modelling, we demonstrated that cognitive load does influence detection failure rates when there is luminance contrasts between the target and its surrounding neighbours. Results suggest that WIMP interaction designers should consider stimulus-driven factors, which were shown to influence the efficiency with which a target icon can be found in a 3D WIMP interface.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To determine whether the improvement in intermediate vision after bilateral implantation of an aspheric multifocal intraocular lens (IOL) with a +3.00 diopter (D) addition (add) occurs at the expense of optical quality compared with the previous model with a +4.00 D add. SETTING: Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil. DESIGN: Prospective randomized double-masked comparative clinical trial. METHODS: One year after bilateral implantation of Acrysof Restor SN6AD1 +3.00 D IOLs or Acrysof Restor SN6AD3 +4.00 D IOLs, optical quality was evaluated by analyzing the in vivo modulation transfer function (MTF) and point-spread function (expressed as Strehl ratio). The Strehl ratio and MTF curve with a 4.0 pupil and a 6.0 mm pupil were measured by dynamic retinoscopy aberrometry. The uncorrected and corrected distance visual acuities at 4 m, uncorrected and distance-corrected near visual acuities at 40 cm, and uncorrected and distance-corrected intermediate visual acuities at 50 cm, 60 cm, and 70 cm were measured. RESULTS: Both IOL groups comprised 40 eyes of 20 patients. One year postoperatively, there were no statistically significant between-group differences in the MTF or Strehl ratio with either pupil size. There were no statistically significant between-group differences in distance or near visual acuity. Intermediate visual acuity was significantly better in the +3.00 D IOL group. CONCLUSION: Results indicate that the improvement in intermediate vision in eyes with the aspheric multifocal +3.00 D add IOL occurred without decreasing optical quality over that with the previous version IOL with a +4.00 D add.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose To evaluate visual, optical, and quality of life (QoL) outcomes and intercorrelations after bilateral implantation of posterior chamber phakic intraocular lenses. Methods Twenty eyes with high to moderate myopia of 10 patients that underwent PRL implantation (Phakic Refractive Lens, Carl Zeiss Meditec AG) were examined. Refraction, visual acuity, photopic and low mesopic contrast sensitivity (CS) with and without glare, ocular aberrations, as well as QoL outcomes (National Eye Institute Refractive Error Quality of Life Instrument-42, NEI RQL-42) were evaluated at 12 months postoperatively. Results Significant improvement in uncorrected (UDVA) and best-corrected distance (CDVA) visual acuities were found postoperatively (p < 0.01), with significant reduction in spherical equivalent (p < 0.01). Low mesopic CS without glare was significantly better than measurements with glare for 1.5, 3, and 6 cycles/degree (p < 0.01). No significant correlations between higher order root mean square (RMS) with CDVA (r = −0.26, p = 0.27) and CS (r ≤ 0.45, p ≥ 0.05) were found. Postoperative binocular photopic CS for 12 cycles/degree and 18 cycles/degree correlated significantly with several RQL-42 scales. Glare index correlated significantly with CS measures and scotopic pupil size (r = −0.551, p = 0.04), but not with higher order RMS (r = −0.02, p = 0.94). Postoperative higher order RMS, postoperative primary coma and postoperative spherical aberration was significant higher for 5-mm pupil diameter (p < 0.01) compared with controls. Conclusions Correction of moderate to high myopia by means of PRL implantation had a positive impact on CS and QoL. The aberrometric increase induced by the surgery does not seem to limit CS and QoL. However, perception of glare is still a relevant disturbance in some cases possibly related to the limitation of the optical zone of the PRL.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: Many practitioners base the prescription of near vision additions on the assertion that only one half or two-thirds of an individual’s amplitude of accommodation is sustainable for a prolonged period. To better understand how much eye focus needs to be restored for presbyopic corrections to be adequate, this study investigated the robustness of the pre-presbyopic human accommodative system during a sustained and intensive near vision task. Methods: Twenty-one pre-presbyopic volunteers (aged 26.1 ± 4.7 years) participated in the study. Binocular subjective amplitude of accommodation was measured before and after a prolonged reading exercise, using the RAF rule. During the 30 min reading task, the subject’s closest comfortable eye-to-text distance and pupil size was monitored. Accommodative accuracy to 0.2, 1.0, 2.0, 3.0 and 4.0 D stimuli was determined objectively using a validated binocular open-view autorefractor immediately before, and after the reading task. Results: Amplitude of accommodation (p = 0.09) and accommodative accuracy (p > 0.05) were statistically unchanged following the intensive near task. The mean proportion of accommodation exerted throughout the near exercise was 80.6% (range 45.3 ± 3.7 to 96.6 ± 4.3%), which increased as the task progressed (F = 2.24, p = 0.02). The mean percentage of accommodation utilised increased with subject age (r = 0.517, p = 0.016). Conclusion: The pre-presbyopic human accommodative system is robust to fatigue during intense and prolonged near work. A greater proportion of one’s amplitude of accommodation may be continuously exerted than previously suggested.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Measurements (autokeratometry, A-scan ultrasonography and video ophthalmophakometry) of ocular surface radii, axial separations and alignment were made in the horizontal meridian of nine emmetropes (aged 20-38 years) with relaxed (cycloplegia) and active accommodation (mean ± 95% confidence interval: 3.7 ± 1.1 D). The anterior chamber depth (-1.5 ± 0.3 D) and both crystalline lens surfaces (front 3.1 ± 0.8 D; rear 2.1 ± 0.6 D) contributed to dioptric vergence changes that accompany accommodation. Accommodation did not alter ocular surface alignment. Ocular misalignment in relaxed eyes is mainly because of eye rotation (5.7 ± 1.6° temporally) with small amounts of lens tilt (0.2 ± 0.8° temporally) and decentration (0.1 ± 0.1 mm nasally) but these results must be viewed with caution as we did not account for corneal asymmetry. Comparison of calculated and empirically derived coefficients (upon which ocular surface alignment calculations depend) revealed that negligible inherent errors arose from neglect of ocular surface asphericity, lens gradient refractive index properties, surface astigmatism, effects of pupil size and centration, assumed eye rotation axis position and use of linear equations for analysing Purkinje image shifts. © 2004 The College of Optometrists.