998 resultados para pulse wave velocity
Resumo:
Pulse wave velocity (PWV) is a surrogate of arterial stiffness and represents a non-invasive marker of cardiovascular risk. The non-invasive measurement of PWV requires tracking the arrival time of pressure pulses recorded in vivo, commonly referred to as pulse arrival time (PAT). In the state of the art, PAT is estimated by identifying a characteristic point of the pressure pulse waveform. This paper demonstrates that for ambulatory scenarios, where signal-to-noise ratios are below 10 dB, the performance in terms of repeatability of PAT measurements through characteristic points identification degrades drastically. Hence, we introduce a novel family of PAT estimators based on the parametric modeling of the anacrotic phase of a pressure pulse. In particular, we propose a parametric PAT estimator (TANH) that depicts high correlation with the Complior(R) characteristic point D1 (CC = 0.99), increases noise robustness and reduces by a five-fold factor the number of heartbeats required to obtain reliable PAT measurements.
Resumo:
Understanding arterial distensibility has shown to be important in the pathogenesis of cardiovascular abnormalities like hypertension. It is also known that arterial pulse wave velocity (PWV) is a measure of the elasticity or stiffness of peripheral arterial blood vessels. However, it generally requires complex instrumentations to have an accurate measurement and not suited for continual monitoring. In this paper, it describes a simple and non-intrusive method to detect the cardiovascular pulse from a human wrist above the radial artery and a fingertip. The main components of this proposed method are a piezoelectric transducer and a photo-plethysmography circuitry. 5 healthy adults (4 male) with age ranging from 25 to 38 years were recruited. The timing consistency of the detected pulsations is first evaluated and compared to that obtained from a commercial electrocardiogram. Furthermore, the derived PWV is then assessed by the predicted values attained from regression equations of two previous similar studies. The results show good correlations (p < 0.05) and similarities for the former and latter respectively. The simplicity and non-invasive nature of the proposed method can be attractive for even younger or badly disturbed patients. Moreover, it can be used for prolonged monitoring for the comfort of the patients.
Resumo:
BACKGROUND: : The systolic augmentation index (sAix), calculated from the central aortic pulse wave (reconstructed from the noninvasive recording of the radial pulse with applanation tonometry), is widely used as a simple index of central arterial stiffness, but has the disadvantage of also being influenced by the timing of the reflected with respect to the forward pressure wave, as shown by its inverse dependence on heart rate (HR). During diastole, the central aortic pulse also contains reflected waves, but their relationship to arterial stiffness and HR has not been studied. METHODS: : In 48 men and 45 women, all healthy, with ages ranging from 19 to 70 years, we measured pulse wave velocity (PWV, patients supine), a standard evaluator of arterial stiffness, and carried out radial applanation tonometry (patients sitting and supine). The impact of reflected waves on the diastolic part of the aortic pressure waveform was quantified in the form of a diastolic augmentation index (dAix). RESULTS: : Across ages, sexes, and body position, there was an inverse relationship between the sAix and the dAix. When PWV and HR were added as covariates to a prediction model including age, sex and body position as main factors, the sAix was directly related to PWV (P < 0.0001) and inversely to HR (P < 0.0001). With the same analysis, the dAix was inversely related to PWV (P < 0.0001) and independent of HR (P = 0.52). CONCLUSION: : The dAix has the same degree of linkage to arterial stiffness as the more conventional sAix, while being immune to the confounding effect of HR. The quantification of diastolic aortic pressure augmentation by reflected waves could be a useful adjunct to pulse wave analysis.
Resumo:
Pulse wave velocity (PWV) is a known parameter that is related to arterial distensibility. However, its potential is hampered by the absence of appropriate techniques to estimate it noninvasively. PWV can be used as an assessment of increased arterial stiffness that is linked to systolic hypertension, excess cardiovascular morbidity and mortality.(1,2)
Resumo:
BACKGROUND: Reconstruction of the central aortic pressure wave from the noninvasive recording of the radial pulse with applanation tonometry has become a standard tool in the field of hypertension. It is not presently known whether recording the radial pulse on the dominant or the nondominant side has any effect on such reconstruction. METHOD: We carried out radial applanation tonometry on both forearms in young, healthy, male volunteers, who were either sedentary (n = 11) or high-level tennis players (n = 10). The purpose of including tennis players was to investigate individuals with extreme asymmetry between the dominant and nondominant upper limb. RESULTS: In the sedentary individuals, forearm circumference and handgrip strength were slightly larger on the dominant (mean +/- SD respectively 27.9 +/- 1.5 cm and 53.8 +/- 10 kg) than on nondominant side (27.3 +/- 1.6 cm, P < 0.001 vs. dominant, and 52.1 +/- 11 kg, P = NS). In the tennis players, differences between sides were more conspicuous (forearm circumference: dominant 28.0 +/- 1.7 cm nondominant 26.4 +/- 1.5 cm, P < 0.001; handgrip strength 61.4 +/- 10.8 vs. 53.4 +/- 9.7 kg, P < 0.001). We found that in both sedentary individuals and tennis players, the radial pulse had identical shape on both sides and, consequently, the reconstructed central aortic pressure waveforms, as well as derived indices of central pulsatility, were not dependent on the side where applanation tonometry was carried out. CONCLUSION: Evidence from individuals with maximal asymmetry of dominant vs. nondominant upper limb indicates that laterality of measurement is not a methodological issue for central pulse wave analysis carried out with radial applanation tonometry.
Resumo:
La rigidité anormalement haute des artères à grande conductance est un marqueur de l'augmentation du risque cardiovasculaire et est typiquement retrouvée chez les patients diabétiques ou hypertendus. Ces vaisseaux deviennent plus rigides avec l'âge, expliquant la haute prévalence d'hypertension systolique chez les personnes âgées. Cette rigidification agit sur la pression sanguine de plusieurs façons. Notamment la fonction windkessel est gênée, menant à l'augmentation de la pression systolique et de la pression puisée, la diminution de la pression diastolique, et ainsi à l'augmentation de la postcharge ventriculaire gauche associée à une probable diminution de la perfusion coronarienne. De plus, la propagation des ondes de pression le long de l'arbre vasculaire est accélérée, de sorte que les ondes réfléchies générées au site de décalage d'impédance atteignent l'aorte ascendante plus tôt par rapport au début de l'éjection ventriculaire, aboutissant à une augmentation de la pression systolique centrale, ce qui n'arriverait pas en présence de vaisseaux moins rigides. Dans ce cas, au contraire, les ondes de pression antérogrades et réfléchies voyages plus lentement, de sorte que les ondes de réflexion tendent à atteindre l'aorte centrale une fois l'éjection terminée, augmentant la pression diastolique et contribuant à la perfusion coronarienne. La tonométrie d'applanation est une méthode non invasive permettant l'évaluation de la forme de l'onde de pression au niveau l'aorte ascendante, basée sur l'enregistrement du pouls périphérique, au niveau radial dans notre étude. Nous pouvons dériver à partir de cette méthode un index d'augmentation systolique (sAIX) qui révèle quel pourcentage de la pression centrale est du aux ondes réfléchies. Plusieurs études ont montré que cet index est corrélé à d'autres mesures de la rigidité artérielle comme la vitesse de l'onde de pouls, qu'il augmente avec l'âge et avec les facteurs de risques cardiovasculaires, et qu'il est capable de préciser le pronostic cardiovasculaire. En revanche, peu d'attention a été portée à l'augmentation de la pression centrale diastolique due aux ondes réfléchies (dAIX). Nous proposons donc de mesurer cet index par un procédé d'analyse développé dans notre laboratoire, et ce dans la même unité que l'index systolique. Etant donné que les modifications de la paroi artérielle modulent d'une part la vitesse de l'onde de pouls (PWV) et d'autre part le temps de voyage aller-retour des ondes de pression réfléchies aux sites de réflexion, toute augmentation de la quantité d'énergie réfléchie atteignant l'aorte pendant la systole devrait être associée à une diminution de l'énergie arrivant au même point pendant la diastole. Notre étude propose de mesurer ces deux index, ainsi que d'étudier la relation de l'index d'augmentation diastolique (dAIX) avec la vitesse de propagation de l'onde de pouls (PWV) et avec le rythme cardiaque (HR), ce dernier étant connu pour influencer l'index d'augmentation systolique (sAIX) . L'influence de la position couchée et assise est aussi étudiée. Les mesures de la PWV et des sAIX et dAIX est réalisée chez 48 hommes et 45 femmes âgées de 18 à 70 ans, classés en 3 groupes d'âges. Les résultats montrent qu'en fonction de l'âge, le genre et la position du corps, il y a une relation inverse entre sAIX et dAIX. Lorsque PWV et HR sont ajoutés comme covariables à un modèle de prédiction comprenant l'âge, le genre et la position du corps comme facteurs principaux, sAIX est directement lié à PWV (p<0.0001) et inversement lié à HR (p<0.0001). Avec la même analyse, dAIX est inversement lié à PWV (p<0.0001) et indépendant du rythme cardiaque (p=0.52). En conclusion, l'index d'augmentation diastolique est lié à la rigidité vasculaire au même degré que l'index d'augmentation systolique, alors qu'il est affranchi de l'effet confondant du rythme cardiaque. La quantification de l'augmentation de la pression aortique diastolique due aux ondes réfléchies pourrait être une partie utile de l'analyse de l'onde de pouls.
Resumo:
Rapport de synthèse Ce travail de thèse s'articule autour de l'importance de l'évaluation de la fonction vasculaire et des répercussions au niveau central, cardiaque, des perturbations du réseau vasculaire. Les maladies cardiovasculaires sont prédominantes dans notre société et causes de morbidité et mortalité importante. La mesure de la pression artérielle classique reste le moyen le plus utilisé pour suivre la santé des vaisseaux, mais ne reflète pas directement ce qui se passe au niveau du coeur. La tonométrie d'aplanation permet depuis quelques années de mesurer l'onde de pouls radial, et par le biais d'une fonction mathématique de transfert validée, il est possible d'en déduire la forme et Γ amplitude de l'onde de pouls central, donc de la pression aortique centrale. Cette dernière est un reflet bien plus direct de la post-charge cardiaque, et de nombreuses études cliniques actuelles s'intéressent à cette mesure pour stratifier le risque ou évaluer l'effet d'un traitement vasculaire. Toutefois, bien que cet outil soit de plus en plus utilisé, il est rarement précisé si la latéralité de la mesure joue un rôle, sachant que certaines propriétés des membres supérieurs peuvent être affectées par un usage préférentiel (masse musculaire, densité osseuse, diamètre des artères, capillarisation musculaire, et même fonction endothéliale). On a en effet observé que ces divers paramètre étaient tous augmentés sur un bras entraîné. Dès lors on peut se poser la question de l'influence de ces adaptations physiologiques sur la mesure indirecte effectuée par le biais du pouls radial. Nous avons investigué les deux membres supérieurs de sujets jeunes et sédentaires (SED), ainsi que ceux de sujets sportifs avec un développement fortement asymétrique des bras, soit des joueurs de tennis de haut niveau (TEN). Des mesures anthropométriques incluant la composition corporelle et la circonférence des bras et avant-bras ont montré que TEN présente une asymétrie hautement significative aux deux mesures entre le bras dominant (entraîné) et l'autre, ce qui est aussi présent pour la force de serrage (mesurée au dynamomètre de Jamar). L'analyse des courbes centrales de pouls ne montre aucune différence entre les deux membres dans chaque groupe, par contre on peut observer une différence entre SED et TEN, avec un index d'augmentation diastolique qui est 50 % plus élevé chez TEN. Les index d'augmentation systolique sont identiques dans les deux groupes. On peut retenir de cette étude la validité de la méthode de tonométrie d'aplanation quel que soit le bras utilisé (dominant ou non-dominant) et ce même si une asymétrie conséquente est présente. Ces données sont clairement nouvelles et permettent de s'affranchir de cette variable dans la mesure d'un paramètre cardiovasculaire dont l'importance est actuellement grandissante. Les différences d'index diastolique sont expliquées par la fréquence cardiaque et la vitesse de conduction de l'onde de pouls plus basses chez TEN, causant un retard diastolique du retour de l'onde au niveau central, phénomène précédemment bien décrit dans la littérature.
Resumo:
We have explored the possibility of obtaining first-order permeability estimates for saturated alluvial sediments based on the poro-elastic interpretation of the P-wave velocity dispersion inferred from sonic logs. Modern sonic logging tools designed for environmental and engineering applications allow one for P-wave velocity measurements at multiple emitter frequencies over a bandwidth covering 5 to 10 octaves. Methodological considerations indicate that, for saturated unconsolidated sediments in the silt to sand range and typical emitter frequencies ranging from approximately 1 to 30 kHz, the observable velocity dispersion should be sufficiently pronounced to allow one for reliable first-order estimations of the permeability structure. The corresponding predictions have been tested on and verified for a borehole penetrating a typical surficial alluvial aquifer. In addition to multifrequency sonic logs, a comprehensive suite of nuclear and electrical logs, an S-wave log, a litholog, and a limited number laboratory measurements of the permeability from retrieved core material were also available. This complementary information was found to be essential for parameterizing the poro-elastic inversion procedure and for assessing the uncertainty and internal consistency of corresponding permeability estimates. Our results indicate that the thus obtained permeability estimates are largely consistent with those expected based on the corresponding granulometric characteristics, as well as with the available evidence form laboratory measurements. These findings are also consistent with evidence from ocean acoustics, which indicate that, over a frequency range of several orders-of-magnitude, the classical theory of poro-elasticity is generally capable of explaining the observed P-wave velocity dispersion in medium- to fine-grained seabed sediments
Resumo:
Rapport de synthèseLe syndrome d'apnées obstructives du sommeil (SAOS) est une pathologie respiratoire fréquente. Sa prévalence est estimée entre 2 et 5% de la population adulte générale. Ses conséquences sont importantes. Notamment, une somnolence diurne, des troubles de la concentration, des troubles de la mémoire et une augmentation du risque d'accident de la route et du travail. Il représente également un facteur de risque cardiovasculaire indépendant.Ce syndrome est caractérisé par la survenue durant le sommeil d'obstructions répétées des voies aériennes supérieures. L'arrêt ou la diminution d'apport en oxygène vers les poumons entraîne des épisodes de diminution de la saturation en oxygène de l'hémoglobine. Les efforts ventilatoires visant à lever l'obstacle présent sur les voies aériennes causent de fréquents réveils à l'origine d'une fragmentation du sommeil.La polysomnographie (PSG) représente le moyen diagnostic de choix. Il consiste en l'enregistrement dans un laboratoire du sommeil et en présence d'un technicien diplômé, du tracé électroencéphalographique (EEG), de l'électrooculogramme (EOG), de l'électromyogramme mentonnier (EMG), du flux respiratoire nasal, de l'oxymétrie de pouls, de la fréquence cardiaque, de l'électrocardiogramme (ECG), des mouvements thoraciques et abdominaux, de la position du corps et des mouvements des jambes. L'examen est filmé par caméra infrarouge et les sons sont enregistrés.Cet examen permet entre autres mesures, de déterminer les événements respiratoires obstructifs nécessaires au diagnostic de syndrome d'apnée du sommeil. On définit une apnée lors d'arrêt complet du débit aérien durant au moins 10 secondes et une hypopnée en cas, soit de diminution franche de l'amplitude du flux respiratoire supérieure à 50% durant au moins 10 secondes, soit de diminution significative (20%) de l'amplitude du flux respiratoire pendant au minimum 10 secondes associée à un micro-éveil ou à une désaturation d'au moins 3% par rapport à la ligne de base. La détection des micro-éveils se fait en utilisant les dérivations électroencéphalographiques, électromyographiques et électrooculographiques. Il existe des critères visuels de reconnaissance de ces éveils transitoire: apparition de rythme alpha (8.1 à 12.0 Hz) ou beta (16 à 30 Hz) d'une durée supérieure à 3 secondes [20-21].Le diagnostic de S AOS est retenu si l'on retrouve plus de 5 événements respiratoires obstructifs par heure de sommeil associés soit à une somnolence diurne évaluée selon le score d'Epworth ou à au moins 2 symptômes parmi les suivants: sommeil non réparateur, étouffements nocturne, éveils multiples, fatigue, troubles de la concentration. Le S AOS est gradué en fonction du nombre d'événements obstructifs par heure de sommeil en léger (5 à 15), modéré (15 à 30) et sévère (>30).La polysomnographie (PSG) comporte plusieurs inconvénients pratiques. En effet, elle doit être réalisée dans un laboratoire du sommeil avec la présence permanente d'un technicien, limitant ainsi son accessibilité et entraînant des délais diagnostiques et thérapeutiques. Pour ces mêmes raisons, il s'agit d'un examen onéreux.La polygraphie respiratoire (PG) représente l'alternative diagnostique au gold standard qu'est l'examen polysomnographique. Cet examen consiste en l'enregistrement en ambulatoire, à savoir au domicile du patient, du flux nasalrespiratoire, de l'oxymétrie de pouls, de la fréquence cardiaque, de la position du corps et du ronflement (par mesure de pression).En raison de sa sensibilité et sa spécificité moindre, la PG reste recommandée uniquement en cas de forte probabilité de SAOS. Il existe deux raisons principales à l'origine de la moindre sensibilité de l'examen polygraphique. D'une part, du fait que l'état de veille ou de sommeil n'est pas déterminé avec précision, il y a dilution des événements respiratoires sur l'ensemble de l'enregistrement et non sur la période de sommeil uniquement. D'autre part, en l'absence de tracé EEG, la quantification des micro-éveils est impossible. Il n'est donc pas possible dans l'examen poly graphique, de reconnaître une hypopnée en cas de diminution de flux respiratoire de 20 à 50% non associée à un épisode de désaturation de l'hémoglobine de 3% au moins. Alors que dans l'examen polysomnographique, une telle diminution du flux respiratoire pourrait être associée à un micro-éveil et ainsi comptabilisée en tant qu'hypopnée.De ce constat est né la volonté de trouver un équivalent de micro-éveil en polygraphie, en utilisant les signaux à disposition, afin d'augmenter la sensibilité de l'examen polygraphique.Or plusieurs études ont démontrés que les micro-éveils sont associés à des réactions du système nerveux autonome. Lors des micro-éveils, on met en évidence la survenue d'une vasoconstriction périphérique. La variation du tonus sympathique associée aux micro-éveils peut être mesurée par différentes méthodes. Les variations de l'amplitude de l'onde de pouls mesurée par pulsoxymétrie représentant un marqueur fiable de la vasoconstriction périphérique associée aux micro-réveils, il paraît donc opportun d'utiliser ce marqueur autonomique disponible sur le tracé des polygraphies ambulatoires afin de renforcer la sensibilité de cet examen.Le but de l'étude est d'évaluer la sensibilité des variations de l'amplitude de l'onde de pouls pour détecter des micro-réveils corticaux afin de trouver un moyen d'augmenter la sensibilité de l'examen polygraphique et de renforcer ainsi sont pouvoir diagnostic.L'objectif est de démontrer qu'une diminution significative de l'amplitude de l'onde pouls est concomitante à une activation corticale correspondant à un micro¬réveil. Cette constatation pourrait permettre de déterminer une hypopnée, en polygraphie, par une diminution de 20 à 50% du flux respiratoire sans désaturation de 3% mais associée à une baisse significative de l'amplitude de pouls en postulant que l'événement respiratoire a entraîné un micro-réveil. On retrouve par cette méthode les mêmes critères de scoring d'événements respiratoires en polygraphie et en polysomnographie, et l'on renforce la sensibilité de la polygraphie par rapport au gold standard polysomnographique.La méthode consiste à montrer en polysomnographie qu'une diminution significative de l'amplitude de l'onde de pouls mesurée par pulsoxymétrie est associée à une activation du signal électroencéphalographique, en réalisant une analyse spectrale du tracé EEG lors des baisses d'amplitude du signal d'onde de pouls.Pour ce faire nous avons réalisé une étude rétrospective sur plus de 1000 diminutions de l'amplitude de l'onde de pouls sur les tracés de 10 sujets choisis de manière aléatoire parmi les patients référés dans notre centre du sommeil (CIRS) pour suspicion de trouble respiratoire du sommeil avec somnolence ou symptomatologie diurne.Les enregistrements nocturnes ont été effectués de manière standard dans des chambres individuelles en utilisant le système d'acquisition Embla avec l'ensemble des capteurs habituels. Les données ont été par la suite visuellement analysées et mesurées en utilisant le software Somnologica version 5.1, qui fournit un signal de l'amplitude de l'onde de pouls (puise wave amplitude - PWA).Dans un premier temps, un technicien du sommeil a réalisé une analyse visuelle du tracé EEG, en l'absence des données du signal d'amplitude d'onde de pouls. Il a déterminé les phases d'éveil et de sommeil, les stades du sommeil et les micro¬éveils selon les critères standards. Les micro-éveils sont définis lors d'un changement abrupt dans la fréquence de l'EEG avec un pattern d'ondes thêta-alpha et/ou une fréquence supérieure à 16 Hz (en l'absence de fuseau) d'une durée d'au minimum trois secondes. Si cette durée excède quinze secondes, l'événement correspond à un réveil.Puis, deux investigateurs ont analysé le signal d'amplitude d'onde de pouls, en masquant les données du tracé EEG qui inclut les micro-éveils. L'amplitude d'onde de pouls est calculée comme la différence de valeur entre le zénith et le nadir de l'onde pour chaque cycle cardiaque. Pour chaque baisse de l'amplitude d'onde de pouls, la plus grande et la plus petite amplitude sont déterminées et le pourcentage de baisse est calculé comme le rapport entre ces deux amplitudes. On retient de manière arbitraire une baisse d'au moins 20% comme étant significative. Cette limite a été choisie pour des raisons pratiques et cliniques, dès lors qu'elle représentait, à notre sens, la baisse minimale identifiable à l'inspection visuelle. Chaque baisse de PWA retenue est divisée en 5 périodes contiguës de cinq secondes chacune. Deux avant, une pendant et deux après la baisse de PWA.Pour chaque période de cinq secondes, on a pratiqué une analyse spectrale du tracé EEG correspondant. Le canal EEG C4-A1 est analysé en utilisant la transformée rapide de Fourier (FFT) pour chaque baisse de PWA et pour chaque période de cinq secondes avec une résolution de 0.2 Hz. La distribution spectrale est catégorisée dans chaque bande de fréquence: delta (0.5 à 4.0 Hz); thêta (4.1 à 8.0Hz); alpha (8.1 à 12.0 Hz); sigma (12.1 à 16 Hz) et beta (16.1 à 30.0 Hz). La densité de puissance (power density, en μΥ2 ) pour chaque bande de fréquence a été calculée et normalisée en tant que pourcentage de la puissance totale. On a déterminé, ensuite, la différence de densité de puissance entre les 5 périodes par ANOVA on the rank. Un test post hoc Tukey est été utilisé pour déterminer si les différences de densité de puissance étaient significatives. Les calculs ont été effectués à l'aide du software Sigmastat version 3.0 (Systat Software San Jose, California, USA).Le principal résultat obtenu dans cette étude est d'avoir montré une augmentation significative de la densité de puissance de l'EEG pour toutes les bandes de fréquence durant la baisse de l'amplitude de l'onde de pouls par rapport à la période avant et après la baisse. Cette augmentation est par ailleurs retrouvée dans la plupart des bande de fréquence en l'absence de micro-réveil visuellement identifié.Ce résultat témoigné donc d'une activation corticale significative associée à la diminution de l'onde de pouls. Ce résulat pourrait permettre d'utiliser les variations de l'onde de pouls dans les tracés de polygraphie comme marqueur d'une activation corticale. Cependant on peut dire que ce marqueur est plus sensible que l'analyse visuelle du tracé EEG par un technicien puisque qu'on notait une augmentation de lactivité corticale y compris en l'absence de micro-réveil visuellement identifié. L'application pratique de ces résultats nécessite donc une étude prospective complémentaire.
Resumo:
Velocity-density tests conducted in the laboratory involved small 4-inch diameter by 4.58-inch-long compacted soil cylinders made up of 3 differing soil types and for varying degrees of density and moisture content, the latter being varied well beyond optimum moisture values. Seventeen specimens were tested, 9 with velocity determinations made along two elements of the cylinder, 180 degrees apart, and 8 along three elements, 120 degrees apart. Seismic energy was developed by blows of a small tack hammer on a 5/8-inch diameter steel ball placed at the center of the top of the cylinder, with the detector placed successively at four points spaced 1/2-inch apart on the side of the specimen involving wave travel paths varying from 3.36 inches to 4.66 inches in length. Time intervals were measured using a model 217 micro-seismic timer in both laboratory and field measurements. Forty blows of the hammer were required for each velocity determination, which amounted to 80 blows on 9 laboratory specimens and 120 blows on the remaining 8 cylinders. Thirty-five field tests were made over the three selected soil types, all fine-grained, using a 2-foot seismic line with hammer-impact points at 6-inch intervals. The small tack hammer and 5/8-inch steel ball was, again, used to develop seismic wave energy. Generally, the densities obtained from the velocity measurements were lower than those measured in the conventional field testing. Conclusions were reached that: (1) the method does not appear to be usable for measurement of density of essentially fine-grained soils when the moisture content greatly exceeds the optimum for compaction, and (2) due to a gradual reduction in velocity upon aging, apparently because of gradual absorption of pore water into the expandable interlayer region of the clay, the seismic test should be conducted immediately after soil compaction to obtain a meaningful velocity value.