915 resultados para priming and fisiological quality seeds
Resumo:
Subtropical grasslands are low in organic matter digestibility (OMD) (0.60) and nitrogen (N) (15 g/kg) for much of the year and this limits cattle production which is characterized by low calving rates and low weaning weights. Production has been based on Bos taurus British breeds of cattle but this is changing and now many breeding herds comprise B, indicus cows and their crosses. This change has increased some aspects of production, but low calving rates persist. A 4-year study was undertaken with a view to improve calving rates and weaner output by supplementing cows grazing either native or improved pastures with a high protein oilseed meal (cottonseed meal; CSM) on four sites. These sites were subdivided into a total of 36 paddocks to allow for two replications in a 3 breeds X 3 supplementation rates X 2 pastures factorial design. Selected cows (no. = 216) from Hereford (H), Brahman (B) and Brahman X Hereford (BH) breed types were set to graze either native pastures (0.45 to 0.62 OMD, 8 to 15 g N per kg; low quality) or improved pastures (0.47 to 0.67 OA ID, 10 to 22 g N per kg; medium quality). Cows were given either 0, 750 or 1500 g/day of CSM for 130 days from calving until 4 weeks into a 12- to 13-week mating period. The CSM was given as two meals per week. Live weight at mating of cows on the low quality pasture was increased (P < 0.01) over those not supplemented by feeding either 750 g CSM per day (H and B cows) or 1500 g CSM per day tall cows). There was no significant effect of supplementation on the mating weights of B cows grazing the medium quality sites. Calving rate of B cows was not increased by their supplementation on either low (4-year mean 58.3 %) or medium quality pastures (66.8%) but did tend to be higher in H cows when supplemented at 1500 g CSM per day on the low (66.7 v. 78.0 (s.e. 6.09) %; P < 0.1) and medium quality pastures (70.5 v. 93.5 (s.e. 4.72) %). An increased calving rate (65.8 (s.e. 6.6) % to 83.2 (s.e. 5.82) % in supplemented BH cows grazing low quality pastures approached significance (P < 0.1) when given CSM at 1500 g/day but there was no increased trend in calving rate when this breed type was supplemented on medium quality pastures. Weaning weights of calves from and B and BH cows were increased (P < 0.05) by supplementation of their darns at 750 g/day and for calves weaned from H cows supplemented at 1500 g/day of CSM. Supplementation at 1500 g/day on low quality pastures increased weaner output per cow mated by 120% for H, by 65% for BH cows and by 50% for B cows. Weaner output was increased by 34 and 40%, respectively, for B and H cows when supplemented at 750 g/day and grazing medium quality pastures but there teas no significant effect of supplementation on output from BH cows. Responses in many parameters differed between years. These results were interpreted as a response to the protein in the oilseed meal supplement by B, taurus and B. taurus X B. indicus cross cows grazing on the subtropical pastures. The study also highlighted that responses to the meal differed between breed types, between the quality of the grazed pasture and between the years of supplementation.
Resumo:
A storage trial of two varieties of adzuki (Vigna angularis), Bloodwood and Erimo, produced in Australia, was conducted to determine the effect of various combinations of temperature, humidity and length of storage on bean quality. The beans were stored for up to 6 mo under the following conditions: temperature (10, 20 and 30degreesC), relative humidity (RH) (40 and 65%). Storage of adzuki at elevated temperature (30degreesC) and low relative humidity (40%) resulted in the greatest loss of bean moisture, increase in hydration times and decrease in bean cooking quality, i.e. increased hardness of cooked beans. The best storage conditions for the preservation of adzuki quality were 10degreesC and 65% RH.
Resumo:
The goal of the current study was to compare the quality of esophageal speech and voice to videofluoroscopic features of the esophagus and pharyngoesophageal (PE) segment. The speech and voice characteristics of 30 laryngectomized patients were rated by 5 speech-language pathologists. Based on these ratings, patients were divided into 3 categories: fluent (n = 9), moderately fluent (n = 10) and nonfluent (n = 11). Videofluoroscopy of the PE region was then performed during both swallowing and voice production. An insufflation test and percutaneous pharyngeal plexus block were required in 9 patients to determine the etiology of poor esophageal voice production. The strongest videofluoroscopic indicators of nonfluent speakers were: (1) small or absent air reservoir and (2) lack of a vibrating PE segment. Fluent speakers presented with shorter PE segments (1.17 mm) compared to moderately fluent speakers (17.1-29.9 mm). Perceptually, fluent speakers presented with a predominantly rough vocal quality. In contrast, moderately fluent speakers presented with a tense quality. In addition, stoma blast noise was reduced in fluent speakers. Videofluoroscopic findings highly correlated with the quality of esophageal speech. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
The detection of replicative intermediate RNAs as markers of active replication of RNA viruses is an essential tool to investigate pathogenesis in acute viral infections, as well as in their long-term sequelae. In this regard, strand-specific PCR has been used widely to distinguish (-) and (+) enteroviral RNAs in pathogenesis studies of diseases such as dilated cardiomyopathy. It has been generally assumed that oligonucleotide-primed reverse transcription of a given RNA generates only the corresponding specific cDNA, thus assuring the specificity of a PCR product amplified from it. Nevertheless, such assumed strand-specificity is a fallacy, because falsely primed cDNAs can be produced by RNA reverse transcription in the absence of exogenously added primers, (cDNA(primer)(-)), and such falsely primed cDNAs are amplifiable by PCR in the same way as the correctly primed cDNAs. Using as a prototype the coxsackievirus B5 (CVB5), a (+) strand RNA virus, it was shown that cDNA(primer)(-) renders the differential detection of viral (-) and (+) RNAs by conventional PCR virtually impossible, due to gross non-specificity. Using in vitro transcribed CVB5 RNAs (+) and (-), it was shown that cDNA(primer)(-) could be removed effectively by magnetic physical separation of correctly primed biotinylated cDNA. Such strategy enabled truly strand-specific detection of RNA (-) and (+), not only for CVB5, but also for other non-polio enteroviruses. These findings indicate that previous conclusions supporting a role for the persistence of actively replicating enterovirus in the pathogenesis of chronic myocarditis should be regarded with strong skepticism and purification of correctly primed cDNA should be used for strand-specific PCR of viral RNA in order to obtain reliable information on this important subject. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Objective: To assess the impact of the mean oocyte diameter (MOD) on occurrence of fertilization and embryo quality in assisted reproduction cycles. Design: Prospective observational study. Setting: Sector of Human Reproduction of the University Hospital, Faculty of Medicine of Ribeirao Preto, University of Sao Paulo (HCFMRP-USP). Patient(s): Thirty-five women undergoing intracytoplasmic sperm injection (ICSI) at the University Hospital of Ribeirao Preto from May to October 2007. Intervention(s): MOD assessment. Main Outcome Measure(s): Occurrence of fertilization and qualitative embryo classification on 2nd and 3rd day after ICSI. Result(s): We divided 160 metaphase II oocytes according to MOD into groups A (MOD below the 25th percentile), B (MOD between 25th and 75th percentile), and C (MOD above the 75th percentile). There was no statistically significant association between MOD and the occurrence of fertilization or the qualitative embryo classification on days 2 and 3. There was no statistically significant difference between groups regarding number of cells or the qualitative embryo classification on days 2 and 3. Conclusion(s): The MOD of mature oocytes does not seem to be related to the occurrence of fertilization or to the developmental quality of human embryos on days 2 and 3 after ICSI. (Fertil Steril(R) 2010;93:621-5. (C)2010 by American Society for Reproductive Medicine.)
Resumo:
Objectives: To evaluate the influence of the morphology of the first polar body (PB) on intracytoplasmic sperm injection (ICSI) outcomes. Methods: The morphology of the first PB was assessed in 3177 metaphase 11 oocytes and classified as: intact and normal size, fragmented, or enlarged size. The rates of fertilization, cleavage, and embryo quality were evaluated on day 2. Results: The rates of fertilization, cleavage, and formation of good quality embryos resulting from the insemination of oocytes with an enlarged first PB (20.7%, 18.7%, and 5.0%, respectively) were significantly lower than those for oocytes with an intact first PB of normal size (70.8%, 62.5%, and 19%, respectively) or a fragmented first PB (69.7%, 60.5%, and 17.1%, respectively). Rates did not differ significantly between oocytes with an intact first PB of normal size and oocytes with a fragmented first PB (P>0.05). Conclusions: The presence of an enlarged PB is related to poorer rates of fertilization, cleavage, and top quality embryos. However, identification of first PB fragmentation does not seem to interfere with ICSI outcomes. (C) 2008 International Federation ofGynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
Resumo:
Molecular breeding is becoming more practical as better technology emerges. The use of molecular markers in plant breeding for indirect selection of important traits can favorably impact breeding efficiency. The purpose of this research is to identify quantitative trait loci (QTL) on molecular linkage groups (MLG) which are associated with seed protein concentration, seed oil concentration, seed size, plant height, lodging, and maturity, in a population from a cross between the soybean cultivars 'Essex' and 'Williams.' DNA was extracted from F-2 generation soybean leaves and amplified via polymerase chain reaction (PCR) using simple sequence repeat (SSR) markers. Markers that were polymorphic between the parents were analyzed against phenotypic trait data from the F-2 and F-4:6 generation. For the F-2 population, significant additive QTL were Satt540 (MLG M, maturity, r(2)=0.11; height, r(2)=0.04, seed size, r(2)=0.061, Satt373 (MLG L, seed size, r(2)=0.04; height, r(2)=0.14), Satt50 (MLG A1, maturity r(2)=0.07), Satt14 (MLG D2, oil, r(2)=0.05), and Satt251 (protein r(2)=0.03, oil, r(2)=0.04). Significant dominant QTL for the F-2 population were Satt540 (MLG M, height, r(2)=0.04; seed size, r(2)=0.06) and Satt14 (MLG D2, oil, r(2)=0.05). In the F-4:6 generation significant additive QTL were Satt239 (MLG I, height, r(2)=0.02 at Knoxville, TN and r(2)=0.03 at Springfield, TN), Satt14 (MLG D2, seed size, r(2)=0.14 at Knoxville, TN), Satt373 (MLG L, protein, r(2)=0.04 at Knoxville, TN) and Satt251 (MLG B I, lodging r(2)=0.04 at Springfield, TN). Averaged over both environments in the F-4:6 generation, significant additive QTL were identified as Satt251 (MLG B 1, protein, r(2)=0.03), and Satt239 (MLG 1, height, r(2)=0.03). The results found in this study indicate that selections based solely on these QTL would produce limited gains (based on low r(2) values). Few QTL were detected to be stable across environments. Further research to identify stable QTL over environments is needed to make marker-assisted approaches more widely adopted by soybean breeders.
Resumo:
Male kids (110) from six goat genotypes, i.e. Boer x Angora (BA), Boer x Feral (1317), Boer x Saanen (BS), Feral x Feral (FF), Saanen x Angora (SA) and Saanen x Feral (SF) and two slaughter weight groups, i.e. Capretto and Chevon (liveweight at slaughter 14-22 and 30-35 kg, respectively) were compared for growth, carcass and meat quality characteristics. Due to their better growth rate, kids from BS and SF genotypes reached the required liveweight for slaughter earlier than kids from other Genotypes used in the study. Chevon kids had a significantly (P < 0.05) lower average daily gain (119 g per day) compared to Capretto kids (171 g per day). SA, SF and FF kids deposited more internal fat in comparison to kids from other genotypes. The dressing percentage of kids ranged from 51 to 54%, with significant differences between genotypes. BS and SF kids had longer carcasses. while BF kids had larger eye muscle area compared to other genotypes. Goat carcasses had a thin subcutaneous fat cover (1.6-2.2 mm). Genotype had a significant (P < 0.05) influence on cooking loss, pigment concentration and muscle colour parameters (CIE L*, a* and b* values). As denoted by the higher V and fibre optic probe values and lower subjective muscle score, the longissimus muscle colour was lighter for BS kids than other genotypes. Cooked meat from the BF kids had lower shear force values and better sensory scores compared to other genotypes. A significant (P < 0.05) decrease in muscle tenderness was observed from Capretto to Chevon carcasses, whereas cooked meat from these two slaughter weight groups was equally accepted (P > 0.05) by the panellists. (C) 2003 Elsevier Science B.V. All rights reserved.
Resumo:
Aim - A quantative primary study to determine whether increasing source to image distance (SID), with and without the use of automatic exposure control (AEC) for antero-posterior (AP) pelvis imaging, reduces dose whilst still producing an image of diagnostic quality. Methods - Using a computed radiography (CR) system, an anthropomorphic pelvic phantom was positioned for an AP examination using the table bucky. SID was initially set at 110 cm, with tube potential set at a constant 75 kVp, with two outer chambers selected and a fine focal spot of 0.6 mm. SID was then varied from 90 cm to 140 cm with two exposures made at each 5 cm interval, one using the AEC and another with a constant 16 mAs derived from the initial exposure. Effective dose (E) and entrance surface dose (ESD) were calculated for each acquisition. Seven experienced observers blindly graded image quality using a 5-point Likert scale and 2 Alternative Forced Choice software. Signal-to-Noise Ratio (SNR) was calculated for comparison. For each acquisition, femoral head diameter was also measured for magnification indication. Results - Results demonstrated that when increasing SID from 110 cm to 140 cm, both E and ESD reduced by 3.7% and 17.3% respectively when using AEC and 50.13% and 41.79% respectively, when the constant mAs was used. No significant statistical (T-test) difference (p = 0.967) between image quality was detected when increasing SID, with an intra-observer correlation of 0.77 (95% confidence level). SNR reduced slightly for both AEC (38%) and no AEC (36%) with increasing SID. Conclusion - For CR, increasing SID significantly reduces both E and ESD for AP pelvis imaging without adversely affecting image quality.
Resumo:
X-ray fluoroscopy is essential in both diagnosis and medical intervention, although it may contribute to significant radiation doses to patients that have to be optimised and justified. Therefore, it is crucial to the patient to be exposed to the lowest achievable dose without compromising the image quality. The purpose of this study was to perform an analysis of the quality control measurements, particularly dose rates, contrast and spatial resolution of Portuguese fluoroscopy equipment and also to provide a contribution to the establishment of reference levels for the equipment performance parameters. Measurements carried out between 2007 and 2013 on 143 fluoroscopy equipment distributed by 34 nationwide health units were analysed. The measurements suggest that image quality and dose rates of Portuguese equipment are congruent with other studies, and in general, they are as per the Portuguese law. However, there is still a possibility of improvements intending optimisation at a national level.
Resumo:
Medical imaging is a powerful diagnostic tool. Consequently, the number of medical images taken has increased vastly over the past few decades. The most common medical imaging techniques use X-radiation as the primary investigative tool. The main limitation of using X-radiation is associated with the risk of developing cancers. Alongside this, technology has advanced and more centres now use CT scanners; these can incur significant radiation burdens compared with traditional X-ray imaging systems. The net effect is that the population radiation burden is rising steadily. Risk arising from X-radiation for diagnostic medical purposes needs minimising and one way to achieve this is through reducing radiation dose whilst optimising image quality. All ages are affected by risk from X-radiation however the increasing population age highlights the elderly as a new group that may require consideration. Of greatest concern are paediatric patients: firstly they are more sensitive to radiation; secondly their younger age means that the potential detriment to this group is greater. Containment of radiation exposure falls to a number of professionals within medical fields, from those who request imaging to those who produce the image. These staff are supported in their radiation protection role by engineers, physicists and technicians. It is important to realise that radiation protection is currently a major European focus of interest and minimum competence levels in radiation protection for radiographers have been defined through the integrated activities of the EU consortium called MEDRAPET. The outcomes of this project have been used by the European Federation of Radiographer Societies to describe the European Qualifications Framework levels for radiographers in radiation protection. Though variations exist between European countries radiographers and nuclear medicine technologists are normally the professional groups who are responsible for exposing screening populations and patients to X-radiation. As part of their training they learn fundamental principles of radiation protection and theoretical and practical approaches to dose minimisation. However dose minimisation is complex – it is not simply about reducing X-radiation without taking into account major contextual factors. These factors relate to the real world of clinical imaging and include the need to measure clinical image quality and lesion visibility when applying X-radiation dose reduction strategies. This requires the use of validated psychological and physics techniques to measure clinical image quality and lesion perceptibility.
Resumo:
The discovery of X-rays was undoubtedly one of the greatest stimulus for improving the efficiency in the provision of healthcare services. The ability to view, non-invasively, inside the human body has greatly facilitated the work of professionals in diagnosis of diseases. The exclusive focus on image quality (IQ), without understanding how they are obtained, affect negatively the efficiency in diagnostic radiology. The equilibrium between the benefits and the risks are often forgotten. It is necessary to adopt optimization strategies to maximize the benefits (image quality) and minimize risk (dose to the patient) in radiological facilities. In radiology, the implementation of optimization strategies involves an understanding of images acquisition process. When a radiographer adopts a certain value of a parameter (tube potential [kVp], tube current-exposure time product [mAs] or additional filtration), it is essential to know its meaning and impact of their variation in dose and image quality. Without this, any optimization strategy will be a failure. Worldwide, data show that use of x-rays has been increasingly frequent. In Cabo Verde, we note an effort by healthcare institutions (e.g. Ministry of Health) in equipping radiological facilities and the recent installation of a telemedicine system requires purchase of new radiological equipment. In addition, the transition from screen-films to digital systems is characterized by a raise in patient exposure. Given that this transition is slower in less developed countries, as is the case of Cabo Verde, the need to adopt optimization strategies becomes increasingly necessary. This study was conducted as an attempt to answer that need. Although this work is about objective evaluation of image quality, and in medical practice the evaluation is usually subjective (visual evaluation of images by radiographer / radiologist), studies reported a correlation between these two types of evaluation (objective and subjective) [5-7] which accredits for conducting such studies. The purpose of this study is to evaluate the effect of exposure parameters (kVp and mAs) when using additional Cooper (Cu) filtration in dose and image quality in a Computed Radiography system.