84 resultados para preload


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Significant hemodynamic changes, including preload and afterload modifications, occur during the transition from the fetal to the neonatal environment. The ductus arteriosus closes, pulmonary vascular resistance decreases, and pulmonary blood flow increases. Strain rate (SR) and strain (e) have been proposed as ultrasound indices for quantifying regional wall deformation. This study was designed to determine if these indices can detect variations in regional deformation between early and late neonatal periods. Methods: Data were obtained from 30 healthy neonates (15 male). The initial study was performed at a mean age of 20.1614 hours (exam 1) and the second at 31.962.9 days (exam 2). Apical and parasternal views were used to quantify regional left ventricular (LV) and right ventricular (RV) longitudinal and radial SR and e, and systolic, early, and late diastolic values were calculated from these curves. A paired-samples t test was performed comparing the two groups. Results: Compared with exam 1, LV radial deformation showed significant reductions in peak systolic e in the basal and mid segments (51615% vs 4669%, P < .01). LV longitudinal deformation behaved similarly, showing significant peak systolic e reductions in all measured segments. Systolic SR showed reductions only in the basal and apical segments of the lateral wall and in the mid portion of the inferior wall (-1.9 +/- 0.5 vs -1.7 +/- 0.3 s(-1) and -1.9 +/- 0.4 vs -1.7 +/- 0.2 s(-1), respectively, P = .03). RV longitudinal free and inferior wall systolic SR and e values were significantly higher in exam 2. Conclusions: LV peak systolic e decreases in exam 2 were possibly due to afterload increase and preload decrease. The lower RV initial deformation indices could be attributed to increased afterload caused by physiologic pulmonary hypertension or immature RV contractile properties. SR seemed to be a more robust index than e and less influenced by preload and afterload hemodynamic alteration. (J Am Soc Echocardiogr 2010;23:294-300.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. The functional haemodynamic variables pulse pressure variation (PPV), stroke volume variation (SVV), and systolic pressure variation (SPV) are widely used to assess haemodynamic status. However, it is not known how these perform during acute lung injury (ALI). This study evaluated the effects of different ventilatory strategies on haemodynamic parameters in pigs with ALI during normovolaemia and hypovolaemia. Methods. Eight anaesthetized Agroceres pigs [40 (1.9) kg] were instrumented with pulmonary artery, PiCCO, and arterial catheters and ventilated. Three ventilatory settings were randomly assigned for 10 min each: tidal volume (VT) 15 ml kg(-1) and PEEP 5 cm H(2)O, VT 8 ml kg(-1) and PEEP 13 cm H(2)O, or VT 6 ml kg(-1) and PEEP 13 cm H(2)O. Data were collected at each setting at baseline, after ALI (lung lavage+Tween 1.5%), and ALI with hypovolaemia (haemorrhage to 30% of estimated blood volume). Results. At baseline, high VT increased PPV, SVV, and SPV (P < 0.05 for all). During ALI, high VT significantly increased PPV and SVV [(P = 0.002 and P = 0.008) respectively.]. After ALI with hypovolaemia, ventilation at VT 6 ml kg(-1) and PEEP 13 cm H(2)O decreased the accuracy of functional haemodynamic variables to predict hypovolaemia, with the exception of PPV (area under the curve 0.875). The parameters obtained by PiCCO were less influenced by ventilatory changes. Conclusions. VT is the ventilatory parameter which influences functional haemodynamics the most. During ventilation with low VT and high PEEP, most functional variables are less able to accurately predict hypovolaemia secondary to haemorrhage, with the exception of PPV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and objective: Dynamic indices represented by systolic pressure variation and pulse pressure variation have been demonstrated to be more accurate than filling pressures in predicting fluid responsiveness. However, the literature is scarce concerning the impact of different ventilatory modes on these indices. We hypothesized that systolic pressure variation or pulse pressure variation could be affected differently by volume-controlled ventilation and pressure-controlled ventilation in an experimental model, during normovolaemia and hypovolaemia. Method: Thirty-two anaesthetized rabbits were randomly allocated into four groups according to ventilatory modality and volaemic status where G1-ConPCV was the pressure-controlled ventilation control group, G2-HemPCV was associated with haemorrhage, G3-ConVCV was the volume-controlled ventilation control group and G4-HemVCV was associated with haemorrhage. In the haemorrhage groups, blood was removed in two stages: 15% of the estimated blood volume withdrawal at M1, and, 30 min later, an additional 15% at M2. Data were submitted to analysis of variance for repeated measures; a value of P < 0.05 was considered to be statistically significant. Results: At MO (baseline), no significant differences were observed among groups. At M1, dynamic parameters differed significantly among the control and hypovolaemic groups (P < 0.05) but not between ventilation modes. However, when 30% of the estimated blood volume was removed (M2), dynamic parameters became significantly higher in animals under volume-controlled ventilation when compared with those under pressure-controlled ventilation. Conclusions: Under normovolaemia and moderate haemorrhage, dynamic parameters were not influenced by either ventilatory modalities. However, in the second stage of haemorrhage (30%), animals in volume-controlled ventilation presented higher values of systolic pressure variation and pulse pressure variation when compared with those submitted to pressure-controlled ventilation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to establish normal ranges of blood flow velocities and indices in the fetal ductus venosus (DV) during the second half of normal pregnancy. A Doppler study of 60 healthy pregnant women without fetal pathologies was performed during the second half of pregnancy. The peak systolic velocity (PSV), peak diastolic velocity (PDV), maximum velocity during atrial contraction (VAC), peak systolic velocity/maximum velocity during atrial contraction (S/A ratio), pulsatility index for the vein (PIV), preload index (PLI) and velocity index for the vein (VIV) were calculated from the DV at 4-week intervals. A significant increase in PSV, PDV and VAC was observed from the 20-23(6/7) to the 28-31(6/7) weeks, with stabilization of values until the end of the pregnancy. On the other hand, the study showed a significant decrease for the S/A ratio, PIV, PLI and VIV from the 20-23(6/7) to the 28-31(6/7) weeks and remaining stable from then until term. (E-mail:dralemar@uol.com.br) (C) 2010 World Federation for Ultrasound in Medicine & Biology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Diastolic dysfunction induced by ischemia may alter transmitral blood flow, but this reflects global ventricular function, and pseudonormalization may occur with increased preload. Tissue Doppler may assess regional diastolic function and is relatively load-independent, but limited data exist regarding its application to stress testing. We sought to examine the stress response of regional diastolic parameters to dobutomine echocardiography (DbE). Methods Sixty-three patients underwent study with DbE: 20 with low probability of coronary artery disease (CAD) and 43 with CAD who underwent angiography. A standard DbE protocol was used, and segments were categorized as ischemic, scar, or normal. Color tissue Doppler was acquired at baseline and peak stress, and waveforms in the basal and mid segments were used to measure early filling (Em), late filling (Am), and E deceleration time. Significant CAD was defined by stenoses >50% vessel diameter. Results Diastolic parameters had limited feasibility because of merging of Em and Am waves at high heart rates and limited reproducibility. Nonetheless, compared with normal segments, segments subtended with significant stenoses showed a lower Em velocity at rest (6.2 +/- 2.6 cm/s vs 4.8 +/- 2.2 cm/s, P < .0001) and peak (7.5 +/- 4.2 cm/s vs 5.1 +/- 3.6 cm/s, P < .0001), Abnormal segments also showed a shorter E deceleration time (51 +/- 27 ms vs 41 +/- 27 ms, P = .0001) at base and peak. No changes were documented in Am. The same pattern was seen with segments identified as ischemic with wall motion score. However, in the absence of ischemia, segments of patients with left ventricular hypertrophy showed a lower Em velocity, with blunted Em responses to stress. Conclusion Regional diastolic function is sensitive to ischemia. However, a number of practical limitations limit the applicability of diastolic parameters for the quantification of stress echocardiography.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Ultrassonografia Cardiovascular

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Anatomical and functional assessment of the heart through Doppler and echocardiography in patients with cell anemia (SCA). METHODS: Twenty-five patients with SCA and ages ranging from 14 to 45 years were prospectively studied in a comparison with 25 healthy volunteers. All of them underwent clinical and laboratory evaluation and Doppler echocardiography as well.The measurements were converted into body surface indices. RESULTS: There were increases in all chamber diameters and left ventricle (LV) mass of the SCA patients. It was characterised an eccentric hypertrophy of the left ventricle. The preload was increased (left ventricle end-diastolic volume) and the afterload was decreased (diastolic blood pressure, peripheral vascular resistance and end-systolic parietal stress ESPS). The cardiac index was increased due to the stroke volume. The ejection fraction and the percentage of the systolic shortening , as well as the systolic time intervals of the LV were equivalent. The isovolumetric contraction period of the LV was increased. The mitral E-septum distance and the end-systolic volume index (ESVi) were increased. The ESPS/ESVi ratio,a loading independent parameter, was decreased in SCA, suggesting systolic dysfunction. No significant differences in the diastolic function or in the pulmonary pressure occurred. CONCLUSION: Chamber dilations, eccentric hypertrophy and systolic dysfunction confirm the evidence of the literature in characterizing a sickle cell anemia cardiomyopathy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess the effect of transient and sustained variations in cardiac load on the values of the end-systolic pressure-diameter relation (ESPDR) of the left ventricle. METHODS: We studied 13 dogs under general anesthesia and autonomic blockade. Variations of cardiac loads were done by elevation of blood pressure by mechanical constriction of the aorta. Two protocols were used in each animal: gradual peaking and decreasing pressure variation, the "transient arterial hypertension protocol" (TAH), and a quick and 10 min sustained elevation, the "sustained arterial hypertension protocol"(SAH). Then, we compared the ESDR in these two situations. RESULTS: Acute elevation of arterial pressure, being it "transitory" or "sustained", did not alter the heart frequency and increased similarly the preload and after load. However, they acted differently in end systolic pressure-diameter relation. It was greater in the SAH than TAH protocol, 21.0±7.3mmHg/mm vs. 9.2±1.2mmHg/mm (p<0.05). CONCLUSION: The left ventricular ESPDR values determined during sustained pressure elevations were higher than those found during transient pressure elevations. The time-dependent activation of myocardial contractility associated with the Frank-Starling mechanism is the major factor in inotropic stimulation during sustained elevations of blood pressure, determining an increase in the ESPDR values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis is a continuation of the Enterprise-Ireland Research Innovation Fund (RIF) Project entitled’ "Design and Manufacturing of Customised Maxillo-Facial Prostheses" The primary objective of this Internal Research Development Program (IRDP) project was to investigate two fundamental design changes 1 To incorporate the over-denture abutments directly into the implant. 2 To remove the restraining wings by the addition of screws, which affix the. implant to the dense material of the jawbone. The prosthetic was redesigned using the ANSYS Finite Element Analysis software program and analysed to* • Reduce the internal von Mises stress distribution The new prosthetic had a -63.63 % lower von Mises stress distribution when compared with the original prosthetic. • Examine the screw preload effects. A maximum relative displacement of 22 6 * lO^mm between the bone and screw was determined, which is well below the critical threshold of micromotion which prevents osseointegration • Investigate the prosthetic-bone contact interface. Three models of the screw, prosthesis, and bone, were studied. (Axisymmetnc, quarter volume, and full volume), a recommended preload torque of 0 32 Nm was applied to the prosthetic and a maximum von Mises stress of 1.988 MPa was predicted • Study the overdenture removal forces. This analysis could not be completed because the correct plastic multilinear properties of the denture material could not be established The redesigned prosthetic was successfully manufactured on a 3-axis milling machine with an indexing system The prosthetic was examined for dimensional quality and strength The research established the feasibility of the new design and associated manufacturing method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Over-resuscitation is deleterious in many critically ill conditions, including major burns. For more than 15 years, several strategies to reduce fluid administration in burns during the initial resuscitation phase have been proposed, but no single or simple parameter has shown superiority. Fluid administration guided by invasive hemodynamic parameters usually resulted in over-resuscitation. As reported in the previous issue of Critical Care, Sánchez-Sánchez and colleagues analyzed the performance of a 'permissive hypovolemia' protocol guided by invasive hemodynamic parameters (PiCCO, Pulsion Medical Systems, Munich, Germany) and vital signs in a prospective cohort over a 3-year period. The authors' results confirm that resuscitation can be achieved with below-normal levels of preload but at the price of a fluid administration greater than predicted by the Parkland formula (2 to 4 mL/kg per% burn). The classic approach based on an adapted Parkland equation may still be the simplest until further studies identify the optimal bundle of resuscitation goals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ventricular assist devices (VADs) are used in treatment for terminal heart failure or as a bridge to transplantation. We created biVAD using the artificial muscles (AMs) that supports both ventricles at the same time. We developed the test bench (TB) as the in vitro evaluating system to enable the measurement of performance. The biVAD exerts different pressure between left and right ventricle like the heart physiologically does. The heart model based on child's heart was constructed in silicone. This model was fitted with the biVAD. Two pipettes containing water with an ultrasonic sensor placed on top of each and attached to ventricles reproduced the preload and the after load of each ventricle by the real-time measurement of the fluid height variation proportionally to the exerted pressure. The LabVIEW software extrapolated the displaced volume and the pressure generated by each side of our biVAD. The development of a standardized protocol permitted the validation of the TB for in vitro evaluation, measurement of the performances of the AM biVAD herein, and reproducibility of data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cannula design is of prime importance for venous drainage during cardiopulmonary bypass (CPB). To evaluate cannulas intended for CPB, an in vitro circuit was set up with silicone tubing between the test cannula encased in a movable preload reservoir and another static reservoir. The pressure-drop (DeltaP) value (P-drainage - P-preload) was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasound flowmeter. Data display and data recording were controlled using a LabView application, custom made particularly for our experiments. Our results demonstrated that DeltaP, Q, and cannula resistance (DeltaP/Q) values were significantly decreased when the cannula diameter was increased for Smart and Medtronic cannulas. Smartcanula showed 36% and 43% less resistance compared to Medtronic venous and Medtronic femoral cannulas, respectively. The cannula shape (straight- or curved-tips) did not affect the DLP cannula resistance. Out of five cannulas tested, the Smartcanula outperforms the other commercially available cannulas. The mean (DeltaP/Q) values were 3.3 +/- 0.08, 4.07 +/- 0.08, 5.58 +/- 0.10, 5.74 +/- 0.15, and 6.45 +/- 0.15 for Smart, Medtronic, Edwards, Sarns, and Gambro cannulas, respectively (two-way ANOVA, p < 0.0001). In conclusion, the present assay allows discrimination between different forms of cannula with high or low lumen resistance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Catopril, an inhibitor of angiotensin converting enzyme, was given orally during cardiac catheterisation to 6 normotensive patients with refractory congestive heart-failure. 60--180 minutes after administration of 25 mg captopril, arterial pressure fell by 25%, cardiac index rose by 38%, and left-ventricular pressure and right-atrial pressure fell by 25% and 40% respectively. Plasma-renin activity rose while plasma noradrenaline and aldosterone fell. These data suggest that, in the short term, captopril can reduce both preload and afterload, and improve cardiac function, in refractory congestive heart-failure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The last twenty years has witnessed important changes in the field of obstetric analgesia and anesthesia. In 2007, we conducted a survey to obtain information regarding the clinical practice of obstetric anesthesia in our country. The main objective was to ascertain whether recent developments in obstetric anesthesia had been adequately implemented into current clinical practice. Methodology: A confidential questionnaire was sent to 391 identified wiss obstetric anesthetists. The questionnaire included 58 questions on 5 main topics: activity and organization of the obstetric unit, practice of labor analgesia, practice of anesthesia for caesarean section, prevention of aspiration syndrome, and pain treatment after cesarean section. Results: The response rate was 80% (311/391). 66% of the surveyed anesthetists worked in intermediate size obstetric units (500-1500 deliveries per year). An anesthetist was on site 24/24 hours in only 53% of the obstetric units. Epidural labor analgesia with low dose local anesthetics combined with opioids was used by 87% but only 30% used patient controlled epidural analgesia (PCEA). Spinal anesthesia was the first choice for elective and urgent cesarean section for 95% of the responders. Adequate prevention of aspiration syndrome was prescribed by 78%. After cesarean section, a multimodal analgesic regimen was prescribed by 74%. Conclusion: When comparing these results with those of the two previous Swiss surveys [1, 2], it clearly appears that Swiss obstetric anesthetists have progressively adapted their practice to current clinical recommendations. But this survey also revealed some insufficiencies: 1. Of the public health system: a. Insufficient number of obstetric anesthetists on site 24 hours/24. b. Lack of budget in some hospitals to purchase PCEA pumps. 2. Of individual medical practice: a. Frequent excessive dosage of hyperbaric bupivacaine during spinal anesthesia for cesarean section. b. Frequent use of cristalloid preload before spinal anesthesia for cesarean section. c. Frequent systematic use of opioids when inducing general anesthesia for cesarean section. d. Fentanyl as the first choice opioid during induction of general anesthesia for severe preeclampsia. In the future, wider and more systematic information campaigns by the mean of the Swiss Association of Obstetric Anesthesia (SAOA) should be able to correct these points.