974 resultados para power losses


Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper presents an analysis and comparison between two circuit topologies of the 3-phase, 3-level unity power factor (Vienna) rectifier on the basis of packaging issues and semiconductor power losses. The analysis indicates the suitability of one particular circuit variant due to restrictions on switching frequency at higher power levels. A comparison is also done between hysteresis and carrier based PWM strategies for current control of the rectifier, along with experimental evaluation of the control strategies on a hardware prototype of the rectifier. The comparison indicates that the carrier based modulation strategy is better suited for use with higher order filters that are utilized in high power applications.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper presents the results of an investigation into the impact of pulse width modulation (PWM) switching schemes on power losses in induction motors and their inverter drives. The PWM schemes considered include sinusoidal PWM, spacevector PWM and discontinuous PWM. Both experimental results and simulated predictions are presented for fractional horsepower and small integral horsepower motors. Direct loss measurements have been carried out using a calorimetric test rig; detailed simulations of the skewed motors have been carried out using multi-slice time-stepped 2D FEA. The simulated and measured losses under the different modulation schemes are compared and discussed. © 2006 IEEE.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper describes a methodology that enables fast and reasonably accurate prediction of the reliability of power electronic modules featuring IGBTs and p-i-n diodes, by taking into account thermo-mechanical failure mechanisms of the devices and their associated packaging. In brief, the proposed simulation framework performs two main tasks which are tightly linked together: (i) the generation of the power devices' transient thermal response for realistic long load cycles and (ii) the prediction of the power modules' lifetime based on the obtained temperature profiles. In doing so the first task employs compact, physics-based device models, power losses lookup tables and polynomials and combined material-failure and thermal modelling, while the second task uses advanced reliability tests for failure mode and time-to-failure estimation. The proposed technique is intended to be utilised as a design/optimisation tool for reliable power electronic converters, since it allows easy and fast investigation of the effects that changes in circuit topology or devices' characteristics and packaging have on the reliability of the employed power electronic modules. © 2012 IEEE.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The work presented in this thesis covers four major topics of research related to the grid integration of wave energy. More specifically, the grid impact of a wave farm on the power quality of its local network is investigated. Two estimation methods were developed regarding the flicker level Pst generated by a wave farm in relation to its rated power as well as in relation to the impedance angle ψk of the node in the grid to which it is connected. The electrical design of a typical wave farm design is also studied in terms of minimum rating for three types of costly pieces of equipment, namely the VAr compensator, the submarine cables and the overhead line. The power losses dissipated within the farm's electrical network are also evaluated. The feasibility of transforming a test site into a commercial site of greater rated power is investigated from the perspective of power quality and of cables and overhead line thermal loading. Finally, the generic modelling of ocean devices, referring here to both wave and tidal current devices, is investigated.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this paper, analysis and synthesis approach for two new variants within the Class-EF power amplifier (PA) family is elaborated. These amplifiers are classified here as Class-E3 F2 and transmission-line (TL) Class-E3 F 2. The proposed circuits offer means to alleviate some of the major issues faced by existing topologies such as substantial power losses due to the parasitic resistance of the large inductor in the Class-EF load network and deviation from ideal Class-EF operation due to the effect of device output inductance at high frequencies. Both lumped-element and transmission-line load networks for the Class-E 3 F PA are described. The load networks of the Class-E3 F and TL Class-E 3 F2amplifier topologies developed in this paper simultaneously satisfy the Class-EF optimum impedance requirements at fundamental frequency, second, and third harmonics as well as simultaneously providing matching to the circuit optimum load resistance for any prescribed system load resistance. Optimum circuit component values are analytically derived and validated by harmonic balance simulations. Trade-offs between circuit figures of merit and component values with some practical limitations being considered are discussed. © 2010 IEEE.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Analysis and synthesis of the new Class-EF power amplifier (PA) are presented in this paper. The proposed circuit offers means to alleviate some of the major issues faced by existing Class-EF and Class-EF PAs, such as (1) substantial power losses due to parasitic resistance of the large inductor in the Class-EF load network, (2) unpredictable behaviour of practical lumped inductors and capacitors at harmonic frequencies, and (3) deviation from ideal Class-EF operation mode due to detrimental effects of device output inductance at high frequencies. The transmission-line load network of the Class-EF PA topology elaborated in this paper simultaneously satisfies the Class-EF optimum impedance requirements at fundamental frequency, second, and third harmonics as well as simultaneously providing matching to the circuit optimum load resistance for any prescribed system load resistance. Furthermore, an elegant solution using an open and short-circuit stub arrangement is suggested to overcome the problem encountered in the mm-wave IC realizations of the Class-EF PA load network due to lossy quarter-wave line. © 2010 IEICE Institute of Electronics Informati.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper presents a methodology to address reactive power compensation using Evolutionary Particle Swarm Optimization (EPSO) technique programmed in the MATLAB environment. The main objective is to find the best operation point minimizing power losses with reactive power compensation, subjected to all operational constraints, namely full AC power flow equations, active and reactive power generation constraints. The methodology has been tested with the IEEE 14 bus test system demonstrating the ability and effectiveness of the proposed approach to handle the reactive power compensation problem.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper presents a Unit Commitment model with reactive power compensation that has been solved by Genetic Algorithm (GA) optimization techniques. The GA has been developed a computational tools programmed/coded in MATLAB. The main objective is to find the best generations scheduling whose active power losses are minimal and the reactive power to be compensated, subjected to the power system technical constraints. Those are: full AC power flow equations, active and reactive power generation constraints. All constraints that have been represented in the objective function are weighted with a penalty factors. The IEEE 14-bus system has been used as test case to demonstrate the effectiveness of the proposed algorithm. Results and conclusions are dully drawn.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Smart micro-grids can produce 'renewable' energy and store them in power storage devices. Power loss, however, is a significant problem in power exchange among the micro-grids and between the macro-station and individual micro-grids. To optimally reduce the total power losses in such a power grid system, in this paper, a greedy coalition formation algorithm is proposed, which allows the macro-station to coordinate mutual power exchange among the micro-grids and between each micro-grid and the macro-station. Our algorithm optimizes the total power losses across the entire power grid, including the cost of charging and discharging power storage devices and power losses due to power transfers. The algorithm creates exchange pairs among the micro-grids, giving priority to pairs with higher power loss reduction per exchanged power unit. Through computer-based simulations, we demonstrate that the proposed approach significantly reduces the average power loss compared with the conventional noncooperative method. The simulations also demonstrate that the communications overhead of our proposal (due to negotiations aimed at forming coalitions) does not significantly affect the available communication resource. © 2014 IEEE.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Because power generation of renewable resources are unstable and demands of the customers are time-varying, the supply power and demands of the customers are always unequal. To meet the demands of the customers, power is transmitted from primary power generation to secondary power generation. It will cause high power loss. To solve this problem, a distributed algorithm is proposed in this paper. By using the algorithm, the micro-grids are able to exchange power with their neighbors so as to minimize the total power losses of the smart grid. Moreover, communication overhead (bandwidth) is reduced, comparing with centralized algorithm. Through computer simulations, we demonstrate that the proposed algorithm can lead to near-optimal result for alleviating the average power loss per micro-grid and reduce the communication overhead significantly in contrast with the centralized approach.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The conventional Newton's method has been considered inadequate to obtain the maximum loading point (MLP) of power systems. It is due to the Jacobian matrix singularity at this point. However, the MLP can be efficiently computed through parameterization techniques of continuation methods. This paper presents and tests new parameterization schemes, namely the total power losses (real and reactive), the power at the slack bus (real or reactive), the reactive power at generation buses, the reactive power at shunts (capacitor or reactor), the transmission lines power losses (real and reactive), and transmission lines power (real and reactive). Besides their clear physical meaning, which makes easier the development and application of continuation methods for power systems analysis, the main advantage of some of the proposed parameters is that its not necessary to change the parameter in the vicinity of the MLP. Studies on the new parameterization schemes performed on the IEEE 118 buses system show that the ill-conditioning problems at and near the MLP are eliminated. So, the characteristics of the conventional Newton's method are not only preserved but also improved. (C) 2003 Elsevier B.V. B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The conventional Newton's method is considered to be inadequate for the computation of the maximum loading point (MLP) of power systems since: (i) it encounters difficulties in the vicinity of the MLP: and (ii) the load flow Jacobian matrix becomes singular at the MLP. It is well known that continuation methods are powerful and useful tools that are able to trace the solution PV curve without experiencing such diffculties. However, continuation methods require a parameterisation so that a modified, well conditioned set of load flow equations is obtained. In particular, the Jacobian matrix associated with this modified set of equations should not be singular at the MLP. The authors propose that the actual power losses in transmission branches (lines and transformers) are used to parameterise the approach. Specific procedures for the automatic determination of the most appropriate parameter (branch) are proposed. Such procedures include the utilisation of fast voltage-stability indices. Simulation results are presented to show that the proposed method is able to trace the whole solution PV curve very efficiently.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The conventional power flow method is considered to be inadequate to obtain the maximum loading point because of the singularity of Jacobian matrix. Continuation methods are efficient tools for solving this kind of problem since different parameterization schemes can be used to avoid such ill-conditioning problems. This paper presents the details of new schemes for the parameterization step of the continuation power flow method. The new parameterization options are based on physical parameters, namely, the total power losses (real and reactive), the power at the slack bus (real or reactive), the reactive power at generation buses, and transmission line power losses (real and reactive). The simulation results obtained with the new approach for the IEEE test systems (14, 30, 57, and 118 buses) are presented and discussed in the companion paper. The results show that the characteristics of the conventional method are not only preserved but also improved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

New parameterization schemes have been proposed by the authors in Part I of this paper. In this part these new options for the parameterization of power flow equations are tested, namely, the total power losses (real and reactive), the power at the slack bus (real or reactive), the reactive power at generation buses, and the transmission line power losses (real and reactive). These different parameterization schemes can be used to obtain the maximum loading point without ill-conditioning problems, once the singularity of Jacobian matrix is avoided. The results obtained with the new approach for the IEEE test systems (14, 30, 57, and 118 buses) show that the characteristics of the conventional method are not only preserved but also improved. In addition, it is shown that the proposed method and the conventional one can be switched during the tracing of PV curves to determine, with few iterations, all points of the PV curve. Several tests were also carried out to compare the performance of the proposed parameterization schemes for the continuation power flow method with the use of both the secant and tangent predictors.