929 resultados para post-steaming treatment


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The effect of an edible film obtained from a commercial Aloe vera extract, on the quality maintenance of minimally processed grapes belonging to three different cultivars (Sugar One, Victoria and Black Magic) was evaluated by enzymatic (PPO, PME, β-GAL), physicochemical (pH, acidity, °Brix), and sensorial methods. All the analyzed parameters were measured in extracts obtained from minimally processed grapes packaged in ordinary atmosphere and stored at 4 °C for 15 days. Samples dipped into Aloe vera showed significant differences (p≤0.05) compared to untreated ones. The determination of such parameters and the evaluation of consumer acceptability were helpful to determine the effectiveness of the post-harvest treatment with Aloe vera for a storage period of 15 days.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objectives. This study compared the residual monomer (RM) in four hard chair-side reline resins (Duraliner II-D, Kooliner-K, Tokuso Rebase Fast-TRF and Ufi Gel hard-UGH) and one heat-polymerized denture base resin (Lucitone 550-L), which was processed using two polymerization cycles (short-LS and long-LL). It was also investigated the effect of two after polymerization treatments on this RM content.Methods. Specimens (n = 18) of each material were produced following the manufacturers' instructions and then divided into three groups. Group I specimens were left untreated (GI-control). Specimens of group II (GII) were given post-polymerization treatment by microwave irradiation. In group III (GIII), specimens were submitted to immersion in water at 55 degrees C (reline resins-10 min; denture base resin L-60min). The RM was analyzed using high performance liquid chromatography (HPLC) and expressed as a percentage of RM. Data were analyzed by two-way ANOVA followed by Tukey's test (alpha = 0.05).Results. Comparing control specimens, statistical differences were found among all materials (p < 0.05), and the results can be arranged as K (1.52%) > D (0.85%) > UGH (0.45%) > LL (0.24%) > TRF (0.14%) > LS (0.08%). Immersion in hot water (GIII) promoted a significant (p < 0.05) reduction in the RM for all materials evaluated compared to control (GI), with the exception of LL specimens. Materials K, UGH and TRF exhibited significantly (p < 0.05) lower values of RM after microwave irradiation (GII) than in the control specimens.Significance. The reduction in RM promoted by water-bath and microwave post-polymerization treatments could improve the mechanical properties and biocompatibility of the relining and denture base materials. (c) 2006 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To test the bond strength between a quartz-fiber-reinforced composite post (FRC) and a resin cement. The null hypothesis was that the bond strength can be increased by using a chairside tribochemical silica-coating system. Materials and Methods: Thirty quartz-FRCs (Light-Post) were divided into 3 groups according to the post surface treatment: G1) Conditioning with 32% phosphoric acid (1 min), applying a silane coupling agent; G2) etching with 10% hydrofluoric acid (1 min), silane application; G3) chairside tribochemical silica coating method (CoJet System): air abrasion with 30-μ SiO x-modified Al2O3 particles, silane application. Thereafter, the posts were cemented into a cylinder (5 mm diameter, 15 mm height) with a resin cement (Duo-Link). After cementation, the specimens were stored in distilled water (37°C/24 h) and sectioned along the x and y axes with a diamond wheel under cooling (Lab-cut 1010) to create nontrimmed bar specimens. Each specimen was attached with cyanoacrylate to an apparatus adapted for the microtensile test. Microtensile testing was conducted on a universal testing machine (1 mm/min). The data obtained were submitted to the one-way ANOVA and Tukey test (α = 0.05). Results: A significant influence of the conditioning methods was observed (p < 0.0001). The bond strength of G3 (15.14 ± 3.3) was significantly higher than the bond strengths of G1 (6.9 ± 2.3) and G2 (12.60 ± 2.8) (p = 0.000106 and p = 0.002631, respectively). Notwithstanding the groups, all the tested specimens showed adhesive failure between the resin cement and FRC. Conclusion: The chairside tribochemical system yielded the highest bond strength between resin cement and quartz-fiber post. The null hypothesis was accepted (p < 0.0001).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The effect of post-polymerization treatments (MW-microwave irradiatron and WB-water-bath) on the degree of conversion (DC) of three reline resins (Ufi Gel hard-U, Kooliner-K, and Tokuso Rebase Fast-T) and one denture base resin (Lucitone 550-L), submitted to two polymerization cycles (LS-short and LL-long), was evaluated by using FT-Raman spectroscopy (n = 5). The molecular weight (Mw) of the powder of all materials and of K polymerized specimens (control; MW; and WB; n = 3) was analyzed using GPC. DC data were analyzed using Kruskal-Wallis test (α = .05). For control specimens, there were no significant differences between U (68%) and LL (77%) and among LL, K (81%), and T (84%). LS (92%) had the highest DC (P<0.05). Only material K exhibited an increased DC after WB (P<0.05). All powders had Mw from 4.0 × 105 to 6.5 × 105 and narrow Mw distributions (2.1 to 3.6). Polymerization and post-polymerization produced K specimens with Mw similar to that of K powder.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this paper was to evaluate two surface conditioning methods associated with the application of adhesive on the post surface for improving the bond to resin cement. Sixty single-rooted bovine teeth were sectioned at 16 mm in length, prepared (9 mm depth), embedded in a PVC cylinder using acrylic resin, and allocated into 3 groups (N.=20) according to post surface treatment: cleaning with ethanol (control group); etching with hydrogen peroxide; etching with hydrofluoric acid. Ten posts for each group were silanized and other 10 posts were silanized and received an adhesive agent. The posts were cemented with self-adhesive resin cement (RelyX U100 resin cement). All teeth were sectioned perpendicularly to the long axis (2 mm thickness per slice), submitted to push out bond strength testing and the type of failure was recorded. The obtained data were submitted to two-way ANOVA and Turkey's test, with the level of significance set at 5%. Neither the hydrofluoric acid or hydrogen peroxide post surface treatment, nor the adhesive application, had an influence on bond strength values. The main type of failure was adhesive between cement and dentin. Etching and the application of an adhesive on the post surface did not presented a significant influence on the bond strength results for the fiber post resin cement-root dentin assembly. The cement appears to adhere very well to the fiber post surface rather than the dentin surface.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

ABSTRACTThis study aimed to evaluate the influence of foliar fertilizer doses containing Mn of phenological stages of suggested application in RR soybeans, to recover management damages with glyphosate at postemergence application on seed vigor in post-harvest and post six months storage. The seeds originated from a field experiment conducted , which included two applications of glyphosate, concomitant with foliar fertilizer in growth stages V4 and V6, with 0.00, 113.50 and 227.00 mg ha-1doses of Mn2+. Germination, GSI (Germination Speed Index), electrical conductivity tests and the first count of seeds were conducted. The application of Mn did not affect the physiological quality of RR soy in postharvest. However, in post-storage, higher doses of Mn had a negative effect on tests of abnormal seedlings, GSI and electrical conductivity. The applications of Mn, regardless of the developmental stage, did not interfere in the germination and first count tests, with and without storage. The electrical conductivity test showed a higher correlation with the seed germination test in the post-harvest treatment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study reports preliminary results of virus neutralizing antibody (VNA) titers obtained on different days in the course of human anti-rabies immunization with the 2-1-1 schedule (one dose is given in the right arm and one dose in the left arm at day 0, and one dose is apllied on days 7 and 21), recommended by WHO for post-exposure treatment with cell culture vaccines. A variant schedule (double dose on day zero and another on day 14) was also tested, both employing suckling mouse brain vaccine. A complete seroconversion rate was obtained after only 3 vaccine doses, and almost all patients (11 of 12) presented titers higher than 1.0 IU/ml. Both neutralizing response and seroconversion rates were lower in the group receiving only 3 doses, regardless of the sample collecting day. Although our results are lower than those found with cell culture vaccines, the geometry mean of VNA is fully satisfactory, overcoming the lower limit recommended by WHO of 0.5 IU/ml. The 2-1-1 schedule could be an alternative one for pre exposure immunization, shorter than the classical 3+1 regimen (one dose on days 0, 2, 4 and 30) with only three visits to the doctor, instead of four.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A indústria metalomecânica nacional possui uma larga tradição no fabrico de equipamentos de elevada qualidade nas mais diversas vertentes. Seja em moldes, colunas de geradores de energia eólica, torres de telecomunicações, equipamento para a agropecuária, básculas de camiões ou simplesmente em silos, a indústria metalomecânica portuguesa é reconhecida internacionalmente pela sua competitividade e qualidade. Sectores como o da maquinagem, estampagem e soldadura mantêm viva a economia nacional, exportando produtos e serviços de engenharia que são largamente reconhecidos pelas empresas estrangeiras, tanto na Europa como em África e na América. O sector da construção soldada teve sempre uma forte tradição no nosso país, conhecendo um novo impulso com o fabrico de estruturas metálicas para geradores de energia eólica e torres de telecomunicações. Atualmente esta indústria mantém viva a sua atividade devido a um forte ’know-how’ nesta matéria e a uma qualidade invejável. Apesar do forte ‘know-how’ já existente, esta indústria está constantemente a ser solicitada para novos desafios, passando pela necessidade da aplicação de novos materiais os quais trazem sempre requisitos específicos aos processos, necessitando ser estudados com pormenor. Este estudo baseia-se na necessidade de uma empresa industrial portuguesa precisar de realizar equipamentos em construção soldada com base em aço do tipo Cr-Mo, grau 91, cuja soldadura é tradicionalmente bastante complicada. A realização dos adequados tratamentos ao material, quer antes, quer depois da soldadura, são a garantia de que a qualidade final do produto atinge os níveis exigidos pelos clientes. Assim, o presente estudo, com uma forte componente experimental, permitiu determinar com sucesso quais as melhores condições para o ciclo térmico na soldadura que podem ser aplicadas a esta liga, para que os resultados obtidos possam exibir a qualidade desejada.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciências da Saúde

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Polyclonal intravenous immunoglobulin (IVIg) treatment reduces crossmatch positivity and increases rates of transplantation in highly sensitised patients (HS). We quantified the panel reactive antibody (PRA) by microlymphocytotoxicity (MLCC), and we analysed anti-HLA class I and class II IgG specific antibody repertoire by Luminex before and after IVIg infusion alone in HS patients awaiting kidney transplantation. Five patients received three monthly infusions of 1 g/kg of IVIg. Serum samples collected pre and post IVIg treatment were submitted for PRA analysis by MLCC. Anti-class I and anti-class II antibody specificities were then tested by Luminex. We focused on the anti-HLA class I and class II antibodies directed against HLA expressed by a previous graft. We also analysed the anti-HLA antibody repertoire in three patients who had not received IVIg infusion. The PRA level determined by MLCC decreased significantly in one of the five patients, dropping from 40% to 17%. The Luminex assay showed fluctuations of the anti-HLA antibody levels over time, but no significant longterm modifications of the anti-HLA antibody repertoire were observed, even in the patient with a strong and prolonged reduction of the PRA determined by MLCC. Our results show that IVIg at 1 g/kg is not sufficient to reduce PRA and does not modify the repertoire of specific anti-HLA antibody determined by Luminex.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

It is commonly observed that complex fabricated structures subject tofatigue loading fail at the welded joints. Some problems can be corrected by proper detail design but fatigue performance can also be improved using post-weld improvement methods. In general, improvement methods can be divided into two main groups: weld geometry modification methods and residual stress modification methods. The former remove weld toe defects and/or reduce the stress concentrationwhile the latter introduce compressive stress fields in the area where fatigue cracks are likely to initiate. Ultrasonic impact treatment (UIT) is a novel post-weld treatment method that influences both the residual stress distribution andimproves the local geometry of the weld. The structural fatigue strength of non-load carrying attachments in the as-welded condition has been experimentally compared to the structural fatigue strength of ultrasonic impact treated welds. Longitudinal attachment specimens made of two thicknesses of steel S355 J0 have been tested for determining the efficiency of ultrasonic impacttreatment. Treated welds were found to have about 50% greater structural fatigue strength, when the slope of the S-N-curve is three. High mean stress fatigue testing based on the Ohta-method decreased the degree of weld improvement only 19%. This indicated that the method could be also applied for large fabricated structures operating under high reactive residual stresses equilibrated within the volume of the structure. The thickness of specimens has no significant effect tothe structural fatigue strength. The fatigue class difference between 5 mm and 8 mm specimen was only 8%. It was hypothesized that the UIT method added a significant crack initiation period to the total fatigue life of the welded joints. Crack initiation life was estimated by a local strain approach. Material parameters were defined using a modified Uniform Material Law developed in Germany. Finite element analysis and X-ray diffraction were used to define, respectively, the stress concentration and mean stress. The theoretical fatigue life was found to have good accuracy comparing to experimental fatigue tests.The predictive behaviour of the local strain approach combined with the uniformmaterial law was excellent for the joint types and conditions studied in this work.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Successful lung transplantation for patients with pulmonary fibrosis from telomerase mutations may be limited by systemic complications of telomerase dysfunction, including myelosuppression, cirrhosis, and malignancy. We describe clinical outcomes in 14 lung transplant recipients with telomerase mutations. METHODS: Subjects underwent lung transplantation between February 2005 and April 2014 at 5 transplant centers. Data were abstracted from medical records, focusing on outcomes reflecting post-transplant treatment effects likely to be complicated by telomerase mutations. RESULTS: The median age of subjects was 60.5 years (interquartile range = 52.0-62.0), 64.3% were male, and the mean post-transplant observation time was 3.2 years (SD ± 2.9). A mutation in telomerase reverse transcriptase was present in 11 subjects, a telomerase RNA component mutation was present in 2 subjects, and an uncharacterized mutation was present in 1 subject. After lung transplantation, 10 subjects were leukopenic and 5 did not tolerate lymphocyte anti-proliferative agents. Six subjects developed recurrent lower respiratory tract infections, 7 developed acute cellular rejection (A1), and 4 developed chronic lung allograft dysfunction. Eight subjects developed at least 1 episode of acute renal failure and 10 developed chronic renal insufficiency. In addition, 3 subjects developed cancer. No subjects had cirrhosis. At data censorship, 13 subjects were alive. CONCLUSIONS: The clinical course for lung transplant recipients with telomerase mutations is complicated by renal disease, leukopenia with intolerance of lymphocyte anti-proliferative agents, and recurrent lower respiratory tract infections. In contrast, cirrhosis was absent, acute cellular rejection was mild, and development of chronic lung allograft dysfunction was comparable to other lung transplant recipients. Although it poses challenges, lung transplantation may be feasible for patients with pulmonary fibrosis from telomerase mutations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Due to functional requirement of a structural detail brackets with and without scallop are frequently used in bridges, decks, ships and offshore structure. Scallops are designed to serve as passage way for fluids, to reduce weld length and plate distortions. Moreover, scallops are used to avoid intersection of two or more welds for the fact that there is the presence of inventible inherent initial crack except for full penetrated weld and the formation of multi-axial stress state at the weld intersection. Welding all around the scallop corner increase the possibility of brittle fracture even for the case the bracket is not loaded by primary load. Avoiding of scallop will establish an initial crack in the corner if bracket is welded by fillet welds. If the two weld run pass had crossed, this would have given a 3D residual stress situation. Therefore the presences and absence of scallop necessitates the 3D FEA fatigue resistance of both types of brackets using effective notch stress approach ( ). FEMAP 10.1 with NX NASTRAN was used for the 3D FEA. The first and main objective of this research was to investigate and compare the fatigue resistance of brackets with and without scallop. The secondary goal was the fatigue design of scallops in case they cannot be avoided for some reason. The fatigue resistance for both types of brackets was determined based on approach using 1 mm fictitiously rounded radius based on IIW recommendation. Identical geometrical, boundary and loading conditions were used for the determination and comparison of fatigue resistance of both types of brackets using linear 3D FEA. Moreover the size effect of bracket length was also studied using 2D SHELL element FEA. In the case of brackets with scallop the flange plate weld toe at the corner of the scallop was found to exhibit the highest and made the flange plate weld toe critical for fatigue failure. Whereas weld root and weld toe at the weld intersections were the highly stressed location for brackets without scallop. Thus weld toe for brackets with scallop, and weld root and weld toe for brackets without scallop were found to be the critical area for fatigue failure. Employing identical parameters on both types of brackets, brackets without scallop had the highest except for full penetrated weld. Furthermore the fatigue resistance of brackets without scallop was highly affected by the lack of weld penetration length and it was found out that decreased as the weld penetration was increased. Despite the fact that the very presence of scallop reduces the stiffness and also same time induce stress concentration, based on the 3D FEA it is worth concluding that using scallop provided better fatigue resistance when both types of brackets were fillet welded. However brackets without scallop had the highest fatigue resistance when full penetration weld was used. This thesis also showed that weld toe for brackets with scallop was the only highly stressed area unlike brackets without scallop in which both weld toe and weld root were the critical locations for fatigue failure when different types of boundary conditions were used. Weld throat thickness, plate thickness, scallop radius, lack of weld penetration length, boundary condition and weld quality affected the fatigue resistance of both types of brackets. And as a result, bracket design procedure, especially welding quality and post weld treatment techniques significantly affect the fatigue resistance of both type of brackets.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mutant viral strains deleted in non-essential genes represent useful tools to study the function of specific gene products in the biology of the virus. We herein describe an investigation on the phenotype of a bovine herpesvirus 5 (BoHV-5) recombinant deleted in the gene encoding the enzyme thymidine kinase (TK) in rabbits, with special emphasis to neuroinvasiveness and the ability to establish and reactivate latent infection. Rabbits inoculated with the parental virus (SV-507/99) (n=18) at a low titer (10(5.5)TCID50) shed virus in nasal secretions in titers up to 10(4.5)TCID50 for up to 12 days (average: 9.8 days [5-12]) and 5/ 16 developed neurological disease and were euthanized in extremis. Rabbits inoculated with the recombinant BoHV-5TKΔ at a high dose (10(7.1)TCID50) also shed virus in nasal secretions, yet to lower titers (maximum: 10(2.3)TCID50) and for a shorter period (average: 6.6 days [2-11]) and remained healthy. PCR examination of brain sections of inoculated rabbits at day 6 post-infection (pi) revealed a widespread distribution of the parental virus, whereas DNA of the recombinant BoHV-5TKΔ-was detected only in the trigeminal ganglia [TG] and olfactory bulbs [OB]. Nevertheless, during latent infection (52pi), DNA of the recombinant virus was detected in the TGs, OBs and also in other areas of the brain, demonstrating the ability of the virus to invade the brain. Dexamethasone (Dx) administration at day 65 pi was followed by virus reactivation and shedding by 5/8 rabbits inoculated with the parental strain (mean duration of 4.2 days [1 - 9]) and by none of seven rabbits inoculated with the recombinant virus. Again, PCR examination at day 30 post-Dx treatment revealed the presence of latent DNA in the TGs, OBs and in other areas of the brain of both groups. Taken together, these results confirm that the recombinant BoHV-5TKΔ is highly attenuated for rabbits. It shows a reduced ability to replicate in the nose but retains the ability to invade the brain and to establish latent infection. Additional studies are underway to determine the biological and molecular mechanisms underlying the inability of BoHV-5TKΔ to reactivate from latency.