950 resultados para performance characteristics


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We sought to evaluate the performance of diagnostic tools to establish an affordable setting for early detection of cervical cancer in developing countries. We compared the performance of different screening tests and their feasibility in a cohort of over 12,000 women: conventional Pap smear, liquid-based cytology, visual inspection with acetic acid (VIA), visual inspection with Iodine solution (VILI), cervicography, screening colposcopy, and high-risk human papillomavirus (HPV) testing (HR-HPV) collected by physician and by self-sampling. HR-HPV assay collected by the physician has the highest sensitivity (80 %), but high unnecessary referrals to colposcopy (15.1 %). HR-HPV test in self-sampling had a markedly lower (57.1 %) sensitivity. VIA, VILI, and cervicography had a poor sensitivity (47.4, 55, and 28.6 %, respectively). Colposcopy presented with sensitivity of 100 % in detecting CIN2+, but the lowest specificity (66.9 %). Co-testing with VIA and VILI Pap test increased the sensitivity of stand-alone Pap test from 71.6 to 87.1 % and 71.6 to 95 %, respectively, but with high number of unnecessary colposcopies. Co-testing with HR-HPV importantly increased the sensitivity of Pap test (to 86 %), but with high number of unnecessary colposcopies (17.5 %). Molecular tests adjunct to Pap test seems a realistic option to improve the detection of high-grade lesions in population-based screening programs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of the swirl component of air injection on the performance of an airlift pump was examined experimentally. An airlift pump is a device that pumps a liquid or slurry using only gas injection. In this study, the liquid used was water and the injected gas was air. The effect of the air swirl was determined by measuring the water discharge from an airlift pump with an air injection nozzle in which the air flow had both axial and tangential components and then repeating the tests with a nozzle with only axial injection. The induced water flow was measured using an orifice meter in the supply pipeline. Tests were run for air pressures ranging from 10 to 30 pounds per square inch, gauge (psig), at flow rates from 5 standard cubic feet per minute (scfm) up the maximum values attainable at the given pressure (usually in the range from 20 to 35 scfm). The nozzle with only axial injection produced a water flow rate that wasequivalent to or better than that induced by the nozzle with swirl. The swirl component of air injection was found to be detrimental to pump performance for all but the smallest air injection flow rate. Optimum efficiency was found for air injection pressures of 10 psig to 15 psig. In addition, the effect of using auxiliary tangential injection of water to create a swirl component in the riser before air injection on the overall capacity (i.e., flow rate) and efficiencyof the pump was examined. Auxiliary tangential water injection was found to have no beneficial effect on the pump capacity or performance in the present system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three comprehensive one-dimensional simulators were used on the same PC to simulate the dynamics of different electrophoretic configurations, including two migrating hybrid boundaries, an isotachophoretic boundary and the zone electrophoretic separation of ten monovalent anions. Two simulators, SIMUL5 and GENTRANS, use a uniform grid, while SPRESSO uses a dynamic adaptive grid. The simulators differ in the way components are handled. SIMUL5 and SPRESSO feature one equation for all components, whereas GENTRANS is based on the use of separate modules for the different types of monovalent components, a module for multivalent components and a module for proteins. The code for multivalent components is executed more slowly compared to those for monovalent components. Furthermore, with SIMUL5, the computational time interval becomes smaller when it is operated with a reduced calculation space that features moving borders, whereas GENTRANS offers the possibility of using data smoothing (removal of negative concentrations), which can avoid numerical oscillations and speed up a simulation. SPRESSO with its adaptive grid could be employed to simulate the same configurations with smaller numbers of grid points and thus is faster in certain but not all cases. The data reveal that simulations featuring a large number of monovalent components distributed such that a high mesh is required throughout a large proportion of the column are fastest executed with GENTRANS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Over the last 4 years ADAMTS-13 measurement underwent dramatic progress with newer and simpler methods. AIMS: Blind evaluation of newer methods for their performance characteristics. DESIGN: The literature was searched for new methods and the authors invited to join the evaluation. Participants were provided with a set of 60 coded frozen plasmas that were prepared centrally by dilutions of one ADAMTS-13-deficient plasma (arbitrarily set at 0%) into one normal-pooled plasma (set at 100%). There were six different test plasmas ranging from 100% to 0%. Each plasma was tested 'blind' 10 times by each method and results expressed as percentage vs. the local and the common standard provided by the organizer. RESULTS: There were eight functional and three antigen assays. Linearity of observed-vs.-expected ADAMTS-13 levels assessed as r2 ranged from 0.931 to 0.998. Between-run reproducibility expressed as the (mean) CV for repeated measurements was below 10% for three methods, 10-15% for five methods and up to 20% for the remaining three. F-values (analysis of variance) calculated to assess the capacity to distinguish between ADAMTS-13 levels (the higher the F-value, the better the capacity) ranged from 3965 to 137. Between-method variability (CV) amounted to 24.8% when calculated vs. the local and to 20.5% when calculated vs. the common standard. Comparative analysis showed that functional assays employing modified von Willebrand factor peptides as substrate for ADAMTS-13 offer the best performance characteristics. CONCLUSIONS: New assays for ADAMTS-13 have the potential to make the investigation/management of patients with thrombotic microangiopathies much easier than in the past.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This report provides an analysis of the thermal performance and emissions characteristics of improved biomass stoves constructed using earthen materials. Commonly referred to as mud stoves, this type of improved stove incorporates high clay content soil with an organic binder in the construction of its combustion chamber and body. When large quantities of the mud material are used to construct the stove body, the stove does not offer significant improvements in fuel economy or air quality relative to traditional open fire cooking. This is partly because a significant amount of heat is absorbed by the mass of the stove reducing combustion efficiency and heat transfer to the cook pot. An analysis of the thermal and mechanical properties of stove materials was also performed. A material mixture containing a one‐to‐one ratio by volume of high content clay soil and straw was found to have thermal properties comparable to fired ceramics used in more advanced improved stove designs. Feedback from mud stove users in Mauritania and Mali, West Africa was also collected during implementation. Suggestions for stove design improvements were developed based on this information and the data collected in the performance, emissions, and material properties analysis. Design suggestions include reducing stove height to accommodate user cooking preferences and limiting overall stove mass to reduce heat loss to the stove body.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of recycled materials in asphalt mixtures such as reclaimed asphalt pavements (RAP) have become widely accepted as a replacement for virgin asphalt binder or virgin aggregates. In this study, the RAP content was 30%, and CR additives were blended with the soft unmodified binder by using dry processes. The objective of this study was to investigate and evaluate the engineering properties of dry method application of crumb rubber influences on reclaimed asphalt pavement (RAP) mixtures. To evaluate the effect of rubber-bitumen interaction on the mixture’s mechanical properties, a laboratory investigation has been conducted on a range of dense graded and 30% RAP by dry process crumb rubber modified (CRM) asphalt mixtures containing 0% (control), 1% crumb rubber by the total aggregate mass. The experimental program in this research include the binder extraction for estimating the amount of aged binder in the both fine and coarse RAP material. Before extracting the binder the RAP sieve analysis, have been done to provide the Black grading curve. In continue after the binder extraction the material sieved again to providing the white curve. The comparison of Black and White curve indicated that there is a remarkable difference between the aggregate grading even for the fine RAP. The experimental program was continued by fabricating 12 specimens in different 4 types of mixtures. For the first group no RAP, no rejuvenator and no crumb rubber were used. For the second group 30% of virgin aggregates substituted by RAP material and the third group was similar to the second group just with 0.01% rejuvenator. the forth group was the group, which in that the specimens contain RAP, rejuvenator and crumb rubber. Finally the specimens were tested for Indirect tensile strength. The results indicated that the addition of crumb rubber increased the optimum amount of binder in the mixture with 30% RAP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transportation Systems Center, Cambridge, Mass.National Highway Traffic Safety Administration, Office of Research and Development, Washington, D.C.