982 resultados para penetration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The integration of large amount of wind power into a power system imposes a new challenge for the secure and economic operation of the system. It is necessary to investigate the impacts of wind power generation on the dynamic behavior of the power system concerned. This paper investigates the impacts of large amount of wind power on small signal stability and the corresponding control strategies to mitigate the negative effects. The concepts of different types of wind turbine generators (WTGs) and the principles of the grid-connected structures of wind power generation systems are first briefly introduced. Then, the state-of-the-art of the studies on the impacts of WTGs on small signal stability as well as potential problems to be studied are clarified. Finally, the control strategies on WTGs to enhance power system damping characteristics are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We read with great interest the article entitled “Enhancing drugs absorption through third-degree burn wound eschar” by Manafi et al. [1]. The authors addressed the concern of poor penetration of topically applied anti-microbials through burn eschar and detailed the improvement of this penetration by penetration enhancers. Here, we would like to report the poor penetration of a topical agent into the viable deep dermal layer under burn eschar on a porcine burn model [2]. In burn treatment, a common practice is the topical application of either anti-microbial products or wound enhancing agents. While the activity of anti-microbial products is designed to fight against microbes on the wound surface but with the least toxicity to viable tissue, wound enhancing agents need to reach the viable tissue layer under the burn eschar. Many studies have reported the accelerated healing of superficial burn wounds and skin graft donor sites by the topical application of exogeneous growth factors [3]. It is well known that the efficacy of the penetration of a topical agent on intact skin mostly depends on the molecular size of the product [4] and [5]. While burn injury destroys this epidermal physiological barrier, the coagulated burn tissue layer on the burn wound surface makes it difficult for topical agents to reach viable tissue....

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes the use of a common DC link in residential buildings to allow customers to inject their surplus power that otherwise would be limited due to AC power quality violation. The surplus power can easily be transferred to other phases and feeders through common DC link in order to maintain the balance between generated power and load. PSCAD-EMTDC platform is used to simulate and study the proposed approach. This paper suggests that this structure can be a pathway to the future DC power systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the voltage rise constraints that are initiated from increased renewable generation resources in low voltage distribution networks. In this paper, an approach which is able to mitigate these voltage rise constraints and allow for increased distributed generator penetration is presented. The proposed approach involves utilizing the distribution transformers static tap changer to reduce the distribution feeder voltage setpoint. The proposed approach is modeled on a generic low voltage distribution network using the PSS SINCAL© simulation software package and is also implemented in a real low voltage distribution network to verify its practicality. Results indicate that this approach can be implemented to mitigate the voltage rise constraint and increase small-scale embedded generator penetration in a high proportion of low voltage feeders while avoiding any substantial network costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Installation of domestic rooftop photovoltaic cells (PVs) is increasing due to feed–in tariff and motivation driven by environmental concerns. Even though the increase in the PV installation is gradual, their locations and ratings are often random. Therefore, such single–phase bi–directional power flow caused by the residential customers can have adverse effect on the voltage imbalance of a three–phase distribution network. In this chapter, a voltage imbalance sensitivity analysis and stochastic evaluation are carried out based on the ratings and locations of single–phase grid–connected rooftop PVs in a residential low voltage distribution network. The stochastic evaluation, based on Monte Carlo method, predicts a failure index of non–standard voltage imbalance in the network in presence of PVs. Later, the application of series and parallel custom power devices are investigated to improve voltage imbalance problem in these feeders. In this regard, first, the effectiveness of these two custom power devices is demonstrated vis–à–vis the voltage imbalance reduction in feeders containing rooftop PVs. Their effectiveness is investigated from the installation location and rating points of view. Later, a Monte Carlo based stochastic analysis is utilized to investigate their efficacy for different uncertainties of load and PV rating and location in the network. This is followed by demonstrating the dynamic feasibility and stability issues of applying these devices in the network.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integration of rooftop photovoltaics (PVs) in residential networks at moderate penetration levels is becoming a reality in many countries including Australia. Despite the technical challenges in properly accommodating PV units, one of the major benefits is the ability of PV units to extend useful life time of distribution transformers. This effect is not quantified in the existing literature. This paper carries out an analysis into the impacts of rooftop PVs at different penetration levels on the performance of distribution transformers and residential networks. This paper presents a methodology to quantify the benefit of the distribution transformer life extension brought about by customer-owned rooftop PV units. The proposed methodology is applied to a real distribution system with various scenarios, including different penetration levels. The results show the distribution transformer loss-of-life function, as a function of the rooftop PV penetration level, is monotonically decreasing function which saturates after a certain penetration level. The best life improvements occur with transformers that are highly loaded and the presence of a significant PV installation may support the deferral of transformer upgrades.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reviews the use of multi-agent systems to model the impacts of high levels of photovoltaic (PV) system penetration in distribution networks and presents some preliminary data obtained from the Perth Solar City high penetration PV trial. The Perth Solar City trial consists of a low voltage distribution feeder supplying 75 customers where 29 consumers have roof top photovoltaic systems. Data is collected from smart meters at each consumer premises, from data loggers at the transformer low voltage (LV) side and from a nearby distribution network SCADA measurement point on the high voltage side (HV) side of the transformer. The data will be used to progressively develop MAS models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis addresses voltage violation problem, the most critical issue associated with high level penetration of photovoltaic (PV) in electricity distribution network. A coordinated control algorithm using the reactive power from PV inverter and integrated battery energy storage has been developed and investigated in different network scenarios in the thesis. Probable variations associated with solar generation, end-user participation and network parameters are also considered. Furthermore, a unified data model and well-defined communication protocol to ensure the smooth coordination between all the components during the operation of the algorithm is described. Finally this thesis incorporated the uncertainties of solar generation using probabilistic load flow analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large-scale integration of non-inertial generators such as wind farms will create frequency stability issues due to reduced system inertia. Inertia based frequency stability study is important to predict the performance of power system with increased level of renewables. This paper focuses on the impact large-scale wind penetration on frequency stability of the Australian Power Network. MATLAB simulink is used to develop a frequency based dynamic model utilizing the network data from a simplified 14-generator Australian power system. The loss of generation is modeled as the active power disturbance and minimum inertia required to maintain the frequency stability is determined for five-area power system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cone penetrometer tests were carried out in a 140 mm diameter triaxial chamber by using a miniature cone of diameter 19.5 mm. The rate of cone penetration was varied from 0.01 mm/s to 0.1 mm/s. Tests were performed in (i) clean sand, (ii) silty sand, and (iii) sand added with fly ash. Two different effective vertical pressures (sigma(nu)), 100 kPa and 300 kPa, were employed. It was noted that for clean and silty sand, the effect of penetration rate on the ultimate tip resistance (q(cu)) of the cone was found to remain only marginal. On the other hand, for sand added with 30% fly ash, the variation in q(cu) values with penetration rate was found to become quite significant. The effect of penetratio rate on q(cu) in all the cases was found to increase with a decrease in the rate of cone penetration. It was noted that with an increase in sigma(nu), the effect of penetration rate on q(cu) was found to become smaller. The effect of the cone penetration rate on q(cu) generally reduces with an increase in the relative density of the material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The behaviour of laterally loaded piles is considerably influenced by the uncertainties in soil properties. Hence probabilistic models for assessment of allowable lateral load are necessary. Cone penetration test (CPT) data are often used to determine soil strength parameters, whereby the allowable lateral load of the pile is computed. In the present study, the maximum lateral displacement and moment of the pile are obtained based on the coefficient of subgrade reaction approach, considering the nonlinear soil behaviour in undrained clay. The coefficient of subgrade reaction is related to the undrained shear strength of soil, which can be obtained from CPT data. The soil medium is modelled as a one-dimensional random field along the depth, and it is described by the standard deviation and scale of fluctuation of the undrained shear strength of soil. Inherent soil variability, measurement uncertainty and transformation uncertainty are taken into consideration. The statistics of maximum lateral deflection and moment are obtained using the first-order, second-moment technique. Hasofer-Lind reliability indices for component and system failure criteria, based on the allowable lateral displacement and moment capacity of the pile section, are evaluated. The geotechnical database from the Konaseema site in India is used as a case example. It is shown that the reliability-based design approach for pile foundations, considering the spatial variability of soil, permits a rational choice of allowable lateral loads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A low strain shear modulus plays a fundamental role in the estimation of site response parameters In this study an attempt has been made to develop the relationships between standard penetration test (SPT) N values with the low strain shear modulus (G(max)) For this purpose, field experiments SPT and multichannel analysis of surface wave data from 38 locations in Bangalore, India, have been used, which were also used for seismic microzonation project The in situ density of soil layer was evaluated using undisturbed soil samples from the boreholes Shear wave velocity (V-s) profiles with depth were obtained for the same locations or close to the boreholes The values for low strain shear modulus have been calculated using measured V-s and soil density About 215 pairs of SPT N and G(max) values are used for regression analysis The differences between fitted regression relations using measured and corrected values were analyzed It is found that an uncorrected value of N and modulus gives the best fit with a high regression coefficient when compared to corrected N and corrected modulus values This study shows better correlation between measured values of N and G(max) when compared to overburden stress corrected values of N and G(max)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetometer data, acquired on spacecraft and simultaneously at high and low latitudes on the ground, are compared in order to study the propagation characteristics of hydromagnetic energy deep into the magnetosphere. Single events provide evidence that wave energy at L ∼ 3 can at times be only one order of magnitude lower than at L ∼ 13. In addition, statistical analyses of the H-component groundbased data obtained during local daytime hours of 17 July-3 August 1985 show that wave amplitudes at L ∼ 3 are generally 10-30 times lower than at L ∼ 13. The L-dependence of near-equator magnetic field fluctuations measured on ISEE-2 show a sharp drop in energy near the magnetopause and a more gradual fall-off of energy deeper inside the magnetosphere. Such high levels of wave power deep in the magnetosphere have not been quantitatively understood previously. Our initial attempt is to calculate the decay length of an evanescent wave generated at a thick magnetopause boundary. Numerical calculations show that fast magnetosonic modes (called magnetopause and inner mode) can be generated under very restrictive conditions for the field and plasma parameters. These fast compressional modes may have their energy reduced by only one order of magnitude over a penetration depth of about 8RE. More realistic numerical simulations need to be carried out to see whether better agreement with the data can be attained.