1000 resultados para ozone


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to study the tropospheric ozone concentrations and daily peak cycles in the Lisbon MetropolitanArea (LMA) during the summer season (June, July and August, JJA) covering the 4-yr study period 2002-2005. Theresults show that all the stations have the same pattern: a minimum in the early morning followed by an increase at 1000UTC reaching to a peak at 1300-1400 UTC, dropped again to minimum values 1800 UTC but with different concentrationsdue to regional and local wind circulations and complex dynamic interactions. We identified in Lisbon city the ozone “weekendeffect”. Finally, we studied an episode of very high levels of tropospheric ozone and related daily ozone concentrationswith some meteorological variables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The strong influence of the winter North Atlantic Oscillation (NAO) on the total ozone column (TOC) in the Northern Hemisphere has been reported in a number of previous studies. In this study we show that this influence is not restricted to the winter season but is also significant in summer. Especially interesting effects of the summer NAO (SNAO) on the TOC are observed over the eastern Mediterranean region, where a strongly positive SNAO index is related to the creation of a geopotential height-negative anomaly over Greece with maximum amplitude at 200 hPa. Another anomaly was observed west of the Iberian Peninsula with similar effects on the TOC. Analyzing 26 years of Total Ozone Mapping Spectrometer (TOMS) and Ozone Monitoring Instrument (OMI) data from the equator to midlatitudes (60°) in the Northern Hemisphere, we demonstrate that the SNAO accounts for up to 30% of the TOC variability with a strong latitudinal and longitudinal dependence. Additionally, we obtain significant correlations between the NAO index and the thermal tropopause pressure and also with the geopotential heights at 200 and 500 hPa. Finally, some indirect connections between NAO and the TOC through teleconnections are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO O morango é uma fruta de alto valor comercial e tem uma rápida deterioração, como a demanda por produtos saudáveis, seguros sob o ponto de vista microbiológico e livre de produtos químicos aumenta cada vez mais, o método de aplicação do gás ozônio em uma atmosfera controlada foi proposto. O objetivo deste trabalho foi verificar a eficiência do gás ozônio produzido por um reator, a fim de que os pequenos produtores de morangos possam usá-lo, contribuindo, assim, para as economias regionais. Morangos (Fragaria ananassa) variedade Oso Grande, colhidasna região de Minas Gerais foram divididas dois grupos: o primeiro recebeu tratamento com ozônio e o segundo não. No primeiro grupo, o ozônio foi aplicado durante 20 minutos a partir de um reator de Corona. Os frutos foram armazenados a 4 ° C, por períodos de 5, 10 e 15 dias. A qualidade dos frutos foi relata a partir dos níveis de sólidos solúveis totais (SS), acidez titulável (AT ), pH, compostos fenólicos (CF), ácido ascórbico (AA), perda de massa fresca (PM%) e análise microbiológica (AM), em diferentes tempos de armazenamento de frutos ozonizados e não ozonizados. O uso de gás ozônio foi eficiente para a pós-colheita de morango. Os níveis de microrganismos estão dentro dos limites aceitáveis e as propriedades físicas e químicas foram mantidas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a detailed evaluation of the seasonal performance of the Community Multiscale Air Quality (CMAQ) modelling system and the PSU/NCAR meteorological model coupled to a new Numerical Emission Model for Air Quality (MNEQA). The combined system simulates air quality at a fine resolution (3 km as horizontal resolution and 1 h as temporal resolution) in north-eastern Spain, where problems of ozone pollution are frequent. An extensive database compiled over two periods, from May to September 2009 and 2010, is used to evaluate meteorological simulations and chemical outputs. Our results indicate that the model accurately reproduces hourly and 1-h and 8-h maximum ozone surface concentrations measured at the air quality stations, as statistical values fall within the EPA and EU recommendations. However, to further improve forecast accuracy, three simple bias-adjustment techniques mean subtraction (MS), ratio adjustment (RA), and hybrid forecast (HF) based on 10 days of available comparisons are applied. The results show that the MS technique performed better than RA or HF, although all the bias-adjustment techniques significantly reduce the systematic errors in ozone forecasts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After an introductory discussion emphasising the importance of electrochemistry for the so-called Green Chemical Processes, the article presents a short discussion of the classical ozone generation technologies. Next a revision of the electrochemical ozone production technology focusing on such aspects as: fundamentals, latest advances, advantages and limitations of this technology is presented. Recent results about fundamentals of electrochemical ozone production obtained in our laboratory, using different electrode materials (e.g. boron doped diamond electrodes, lead dioxide and DSAÒ-based electrodes) also are presented. Different chemical processes of interest to the solution of environmental problems involving ozone are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Efforts presented by the scientific community in recent years towards the development of numerous green chemical processes and wastewater treatment technologies are presented and discussed. In the light of these approaches, environmentally friendly technologies, as well as the key role played by the well-known advanced oxidation processes, are discussed, giving special attention to the ones comprising ozone applications. Fundamentals and applied aspects dealing with ozone technology and its application are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to study the influence of effluent organic matter (EfOM) on micropollutants removal by ozone and UV/H2O2. To perform the experiments, deionized water and municipal secondary effluents (SE) were artificially contaminated with atrazine (ATZ) and treated by the two proposed methods. ATZ concentration, COD and TOC were recorded along the reaction time and used to evaluate EfOM effect on the system efficiency. Results demonstrate that the presence of EfOM can significantly reduce the micropollutant removal rate due to competition of EfOM components to react with radicals and/or molecular ozone. The hydroxyl radical scavenging caused by EfOM was quantified as well as the contribution of molecular ozone and �OH radicals during the ozonation of SE. EfOM components promoted higher inhibition of ATZ oxidation by hydroxyl radicals than by molecular ozone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was conducted to evaluate the decomposition kinetics of gaseous ozone in peanut grains. This evaluation was made with 1-kg peanut samples, moisture contents being 7.1 and 10.5% wet basis (w.b.), placed in 3-liter glass containers. The peanut grains were ozonated at the concentration of 450 µg L-1, at 25 and 35 ºC, with gas flow rates of 1.0 and 3.0 L min-1. Time of saturation was determined by quantifying the residual concentration of ozone after the gas passed through the grains to constant mass. The decomposition kinetics of ozone was evaluated after the grain mass was ozone-saturated. For the peanut grains whose moisture content was 7.1% (w.b.), at 25 and 35ºC and with flow rates of 1.0 and 3.0 L min-1, the values obtained for time of saturation of gaseous ozone ranged between 173 and 192 min; the concentration of saturation was approximately 260 µg L-1. For the grains whose moisture content was 10.5% (w.b.), a higher residual concentration of gaseous ozone was obtained at 25 ºC, that of 190 µg L-1. As regards the half-life of ozone, the highest value obtained was equivalent to 7.7 min for grains ozonated at 25 ºC, while for those with moisture content of 10.5% at 35 ºC, half-life was 3.2 min. In the process of ozone decomposition in peanut grains, temperature was concluded to be the key factor. An increase of 10 ºC in the temperature of the grains results in a decrease of at least 43% in the half-life of ozone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ionizing radiation causes its biological effects mainly through oxidative damage induced by reactive oxygen species. Previous studies showed that ozone oxidative preconditioning attenuated pathophysiological events mediated by reactive oxygen species. As inhalation of ozone induces lung injury, the aim of this study was to examine whether ozone oxidative preconditioning potentiates or attenuates the effects of irradiation on the lung. Rats were subjected to total body irradiation, with or without treatment with ozone oxidative preconditioning (0.72 mg/kg). Serum proinflammatory cytokine levels, oxidative damage markers, and histopathological analysis were compared at 6 and 72 h after total body irradiation. Irradiation significantly increased lung malondialdehyde levels as an end-product of lipoperoxidation. Irradiation also significantly decreased lung superoxide dismutase activity, which is an indicator of the generation of oxidative stress and an early protective response to oxidative damage. Ozone oxidative preconditioning plus irradiation significantly decreased malondialdehyde levels and increased the activity of superoxide dismutase, which might indicate protection of the lung from radiation-induced lung injury. Serum tumor necrosis factor alpha and interleukin-1 beta levels, which increased significantly following total body irradiation, were decreased with ozone oxidative preconditioning. Moreover, ozone oxidative preconditioning was able to ameliorate radiation-induced lung injury assessed by histopathological evaluation. In conclusion, ozone oxidative preconditioning, repeated low-dose intraperitoneal administration of ozone, did not exacerbate radiation-induced lung injury, and, on the contrary, it provided protection against radiation-induced lung damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ambient (03) ozone concentrations were compared to ozone damage on milkweed plants to determine if there was a correlation. Eight survey sites of at least 100 plants each were located within 5 kilometers of Air Quality Index (AQI) stations in southern Ontario. Sites were visited nine times from June-September (2007) and milkweed leaves from 75 plants were assessed using methods pioneered in the United States. Ambient 0 3 results were calculated into SUM65, seasonal cumulative 0 3, and total 03. The 0 3 exposure indices SUM65 and cumulative 0 3 were tested statistically to determine which index is biologically relevant to milkweed as an 0 3 damage indicator species. The milkweed damage indices were incidence of leaves damaged per plant, incidence of plants damaged per site, and total 0 3• The incidence of plants injured per site was the best damage parameter with an F(1,28)=17.37, p=0.0003 for SUM65 and F(1,28)=7.5, p=O.0106 for cumulative 03 .. Milkweed plants showed quantifiable ozone damage with minimal spatial differences in damage and thus have potential use as a biomonitor species in southern Ontario.