446 resultados para nodule


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the study was to quantify and compare the effect of CT dose and of size and density of nodules on the detectability of lung nodules and to quantify the influence of CT dose on the size of the nodules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of our study was to compare the effect of dual-energy subtraction and bone suppression software alone and in combination with computer-aided detection (CAD) on the performance of human observers in lung nodule detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To find the best pairing of first and second reader at highest sensitivity for detecting lung nodules with CT at various dose levels. MATERIALS AND METHODS An anthropomorphic lung phantom and artificial lung nodules were used to simulate screening CT-examination at standard dose (100 mAs, 120 kVp) and 8 different low dose levels, using 120, 100 and 80 kVp combined with 100, 50 and 25 mAs. At each dose level 40 phantoms were randomly filled with 75 solid and 25 ground glass nodules (5-12 mm). Two radiologists and 3 different computer aided detection softwares (CAD) were paired to find the highest sensitivity. RESULTS Sensitivities at standard dose were 92%, 90%, 84%, 79% and 73% for reader 1, 2, CAD1, CAD2, CAD3, respectively. Combined sensitivity for human readers 1 and 2 improved to 97%, (p1=0.063, p2=0.016). Highest sensitivities--between 97% and 99.0%--were achieved by combining any radiologist with any CAD at any dose level. Combining any two CADs, sensitivities between 85% and 88% were significantly lower than for radiologists combined with CAD (p<0.03). CONCLUSIONS Combination of a human observer with any of the tested CAD systems provide optimal sensitivity for lung nodule detection even at reduced dose at 25 mAs/80 kVp.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The purpose of this study was to investigate the feasibility of microdose CT using a comparable dose as for conventional chest radiographs in two planes including dual-energy subtraction for lung nodule assessment. MATERIALS AND METHODS We investigated 65 chest phantoms with 141 lung nodules, using an anthropomorphic chest phantom with artificial lung nodules. Microdose CT parameters were 80 kV and 6 mAs, with pitch of 2.2. Iterative reconstruction algorithms and an integrated circuit detector system (Stellar, Siemens Healthcare) were applied for maximum dose reduction. Maximum intensity projections (MIPs) were reconstructed. Chest radiographs were acquired in two projections with bone suppression. Four blinded radiologists interpreted the images in random order. RESULTS A soft-tissue CT kernel (I30f) delivered better sensitivities in a pilot study than a hard kernel (I70f), with respective mean (SD) sensitivities of 91.1% ± 2.2% versus 85.6% ± 5.6% (p = 0.041). Nodule size was measured accurately for all kernels. Mean clustered nodule sensitivity with chest radiography was 45.7% ± 8.1% (with bone suppression, 46.1% ± 8%; p = 0.94); for microdose CT, nodule sensitivity was 83.6% ± 9% without MIP (with additional MIP, 92.5% ± 6%; p < 10(-3)). Individual sensitivities of microdose CT for readers 1, 2, 3, and 4 were 84.3%, 90.7%, 68.6%, and 45.0%, respectively. Sensitivities with chest radiography for readers 1, 2, 3, and 4 were 42.9%, 58.6%, 36.4%, and 90.7%, respectively. In the per-phantom analysis, respective sensitivities of microdose CT versus chest radiography were 96.2% and 75% (p < 10(-6)). The effective dose for chest radiography including dual-energy subtraction was 0.242 mSv; for microdose CT, the applied dose was 0.1323 mSv. CONCLUSION Microdose CT is better than the combination of chest radiography and dual-energy subtraction for the detection of solid nodules between 5 and 12 mm at a lower dose level of 0.13 mSv. Soft-tissue kernels allow better sensitivities. These preliminary results indicate that microdose CT has the potential to replace conventional chest radiography for lung nodule detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiolaria were studied in 19 manganese nodules raised from the bottom. The nodules occurred mainly on the surface of thin Quaternary sediments covering Tertiary deposits of various ages (Middle Eocene to Early Miocene). Radiolaria in nodule cores and in inner and surface layers were studied. We found 85 radiolaria species and groups of species. Usually 1-4 to 6-19 radiolaria species were detected in each of the samples. Species belonging to Middle Eocene, Late Miocene to Early Oligocene, and Oligocene to Early Miocene were found. Rare Neogene species were revealed only in fractured surface layers. Age of the nodules is mainly Oligocene. Seismic waves cause sediment vibration, loosening disintegration, and removal of suspension by bottom currents. The vibration effect causes ancient nodules to float up to the surface of Quaternary sediment. This hypothesis suggests the reason for characteristics of the Clarion-Clipperton zone: regional stratigraphic hiatus, accumulation of residual fields of nodules, and the ''floating up'' of nodules to the surface of the Quaternary sediments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Legacy product - no abstract available

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thanks to the courtesy of the British Museum of Natural History the author obtained from their Challenger collections two small nodules, and through a similar courtesy of the Mineralogical Department of the Riksmuseum in Stockholm one half of a much larger nodule, also from the Challenger Expedition. Results from his initial measurements of the radium contents of these samples convinced the author that the radium in the nodules is accumulated from the surrounding sediment. In the present paper the author conducted a much more thorough investigation on nodules obtained during the U.S. Albatross cruises of Dr. Agassiz. Detailed measurements of radium were conducted on individual layers and spots inside each nodule.