767 resultados para myelin sheath


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Oligodendroglia support axon survival and function through mechanisms independent of myelination, and their dysfunction leads to axon degeneration in several diseases. The cause of this degeneration has not been determined, but lack of energy metabolites such as glucose or lactate has been proposed. Lactate is transported exclusively by monocarboxylate transporters, and changes to these transporters alter lactate production and use. Here we show that the most abundant lactate transporter in the central nervous system, monocarboxylate transporter 1 (MCT1, also known as SLC16A1), is highly enriched within oligodendroglia and that disruption of this transporter produces axon damage and neuron loss in animal and cell culture models. In addition, this same transporter is reduced in patients with, and in mouse models of, amyotrophic lateral sclerosis, suggesting a role for oligodendroglial MCT1 in pathogenesis. The role of oligodendroglia in axon function and neuron survival has been elusive; this study defines a new fundamental mechanism by which oligodendroglia support neurons and axons.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Perspex Machine arose from the unification of computation with geometry. We now report significant redevelopment of both a partial C compiler that generates perspex programs and of a Graphical User Interface (GUI). The compiler is constructed with standard compiler-generator tools and produces both an explicit parse tree for C and an Abstract Syntax Tree (AST) that is better suited to code generation. The GUI uses a hash table and a simpler software architecture to achieve an order of magnitude speed up in processing and, consequently, an order of magnitude increase in the number of perspexes that can be manipulated in real time (now 6,000). Two perspex-machine simulators are provided, one using trans-floating-point arithmetic and the other using transrational arithmetic. All of the software described here is available on the world wide web. The compiler generates code in the neural model of the perspex. At each branch point it uses a jumper to return control to the main fibre. This has the effect of pruning out an exponentially increasing number of branching fibres, thereby greatly increasing the efficiency of perspex programs as measured by the number of neurons required to implement an algorithm. The jumpers are placed at unit distance from the main fibre and form a geometrical structure analogous to a myelin sheath in a biological neuron. Both the perspex jumper-sheath and the biological myelin-sheath share the computational function of preventing cross-over of signals to neurons that lie close to an axon. This is an example of convergence driven by similar geometrical and computational constraints in perspex and biological neurons.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A procura de um método que permita um melhor resultado na anastomose de um nervo completamente seccionado é antiga. Há muitos anos a técnica, dita convencional, para aproximação dos cotos afastados do nervo lesado, é realizada com pontos de fios microcirúrgicos. Mais recentemente, a utilização da cola de fibrina tem permitido a adesão de tecidos, como pele, fáscia e outras estruturas anatômicas. O uso da cola de fibrina, na aproximação das extremidades nervosas, tem sido propagada pela indústria como um fato incontestável. No entanto, somente com a realização de estudos comparativos clínicos e laboratoriais tornou-se possível comparar a eficácia da cola de fibrina como agente de reconstituição em lesões de nervos periféricos. Com o objetivo de comprovar essa afirmação foi realizado um trabalho através de uma mensuração nas bainhas de mielina de cotos regenerados de nervos entre diferentes tipos de anastomose nervosas em nervo isquiático de ratos da raça Wistar. Com esse mesmo escopo, foi mensurado o número de axônios em regeneração após o uso dessa cola. Foi utilizada uma amostra de 35 ratos divididos em 03 grupos (A, B e C). No grupo A, 25 ratos foram submetidos à cirurgia com o uso da cola de fibrina para a anastomose nervosa. No grupo B, 05 ratos foram submetidos ao mesmo procedimento; entretanto, ao reparo nervoso acrescentou-se a utilização de dois pontos opostos de mononylon 9-0, usando-se cola de fibrina no seu interior. No terceiro grupo (C), 05 ratos foram submetidos a neurorrafia com 6 a 8 pontos de mononylon 9-0 sem auxílio da cola de fibrina (anastomose nervosa convencional). Os animais foram submetidos a um novo procedimento após 90 dias, quando o nervo isquiático tratado foi retirado e encaminhado para o estudo. Após esse procedimento, os animais foram sacrificados. Cabe esclarecer que os espécimens foram submetidas a uma preparação histológica, sendo avaliados. Para tanto, foi realizada uma mensuração da espessura média da bainha de mielina das fibras regeneradas. Também foi realizada uma medição do número de axônios regenerados em um milímetro quadrado. Com base nesses achados, foram comparados os resultados.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cem ratos norvégicus, machos, com aproximadamente 3 meses de idade foram distribuídos por sorteio em 2 grupos experimentais: Grupo Controle (GC): com 50 ratos sadios, não diabéticos e Grupo Diabético (GD): com 50 ratos diabéticos, induzidos pela aloxana, sem qualquer tratamento. Cada grupo foi dividido em 5 subgrupos com 10 ratos cada e sacrificados com 1, 3, 6, 9 e 12 meses de seguimento, respectivamente. Parâmetros clínicos (peso, ingestão hídrica e alimentar, e diurese) e laboratoriais (glicemia, glicose urinária e insulina) foram documentados em todos os momentos de avaliação. Um segmento do nervo ciático foi obtido de cada animal, em ambos os grupos, para estudo à MO. e ME. Alterações clínicas e laboratoriais significativas (P<0,01), compatíveis com diabetes grave, foram observadas em todos os animais do GD a partir do 4o dia após a indução. Ratos de ambos os grupos apresentaram alterações no número de fibras mielínicas e nos depósitos intraaxonais de glicogênio que não diferiram, estatisticamente, aos 1, 3 e 6 meses de seguimento. Entretanto, aos 9 e 12 meses, ratos do GD apresentaram diminuição significativa no número de fibras mielínicas, com aumento do número de fibras mielínicas de menor calibre, quando comparados com ratos do GC (P<0,05). Grânulos de glicogênio intraaxonais também foram mais acentuados em ratos do GD no 9o e 12o mês de seguimento. Não foram observadas diferenças na densidade de fibras amielínicas ou alterações ultraestruturais significativas entre os dois grupos, em relação aos espaços intraaxonais e endoneurais, bainhas de mielina e células de Schwann durante todo o estudo.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The authors studied the possible inductive effect of exogenous gangliosides administrated intra-peritoneal and intra-muscular, in 33 rats, after compression and sutures of sciatic nerve. In the animals suffering compression of the sciatic nerve only, the myelin sheath was preserved with good regeneration of the nerve. There was no statistics difference between the two groups with or without the administration of gangliosides. In the group of rats where section of the sciatic nerve and suture were performed, neuroma of amputation as well as dense cicatricial tissue with inflammatory reaction of foreign body type was noted around the sutures. In conclusion, the formation of neuroma of amputation associated with severe inflammatory reaction had an important role in determining the regeneration of the nerve.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nerve regeneration in a sensory nerve was obtained by the application of different techniques: inside-out vein graft (IOVG group) and standard vein graft (SVG group). These techniques provide a good microenvironment for axon regeneration in motor nerves, but their efficiency for regeneration of sensory nerves is controversial. The saphenous nerve was sectioned and repaired by the inside-out and standard vein graft techniques in rats. After 4, 12, and 20 weeks the graft and the distal stump were observed under electron microscopy. In each studied period, the pattern, diameters, and thickness of the myelin sheaths of the regenerated axons were measured in the graft and distal stump. A comparative study about the regenerated nerve fibers by these two different techniques was performed. Regenerated nerve fibers were prominent in both vein grafts 4 weeks after the surgical procedures. On the other hand, in the distal stump, regenerated nerve fibers were observed only from 12 weeks. In both inside-out vein graft and standard vein graft statistical difference was not observed about the diameters and thickness of the myelinated fibers after 20 weeks. On the other hand, the inside-out group had greater regenerated axon number when compared to the standard group. There is a capillary invasion in both graft and distal stump, especially in the IOVG group. The regenerated axons follow these capillaries all the time like satellite microfascicles. After 20 weeks, the diameters of regenerated fibers repaired by the standard vein graft technique were closer to the normal fibers compared to the inside-out vein graft. On the other hand, the pattern of these regenerated axons was better in the IOVG group.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The potential sequelae of intestinal infection with Yersinia enterocolitica include reactive arthritis, erythema nodosum, Reiter's syndrome and other autoimmune diseases. The role of the immune response in the pathogenesis of these diseases has not been fully defined, but autoimmune manifestations may be a consequence of the increase in autoantibodies as a result of polyclonal B-cell activation induced by Yersinia. We investigated the effects of Y enterocolitica 0:3 derivatives on B lymphocyte activation in vivo. Groups of five specific pathogen free (SPF) Swiss mice were inoculated with bacterial cell extract, Yersinia outermembrane proteins (Yops) or lipopolysaccharide (LPS) obtained from Y enterocolitica 0:3 and their immunoglobulin-secreting spleen cells were detected by isotype-specific protein A plaque assay. The presence of specific anti-Yersinia antibodies and autoantibodies was determined in mouse sera by ELISA. In all experiments a marked increase in the number of secretory cells of different isotypes was observed as early as the third day after inoculation. IgG and IgM anti-Yersinia antibodies were detected in the sera of all inoculated mice, and autoantibodies against myosin in the sera of those inoculated with bacterial cell extract. The sera from animals stimulated with LPS reacted with myelin, actin and laminin, while the sera from mice inoculated with Yops reacted with myelin, thyroglobulin and cardiolipin. These results suggest that SPF Swiss mice inoculated with any one of the Y enterocolitica derivatives tested exhibited polyclonal activation of B lymphocytes as a result of stimulation by various bacterial components and not only LPS stimulation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study was designed to present the feasibility of an in vivo image-guided percutaneous cryoablation of the porcine vertebral body. Methods The institutional animal care committee approved this study. Cone-beam computed tomography (CBCT)-guided vertebral cryoablations (n = 22) were performed in eight pigs with short, 2-min, single or double-freezing protocols. Protective measures to nerves included dioxide carbon (CO2) epidural injections and spinal canal temperature monitoring. Clinical, radiological, and pathological data with light (n = 20) or transmission electron (n = 2) microscopic analyses were evaluated after 6 days of clinical follow-up and euthanasia. Results CBCT/fluoroscopic-guided transpedicular vertebral body cryoprobe positioning and CO2 epidural injection were successful in all procedures. No major complications were observed in seven animals (87.5 %, n = 8). A minor complication was observed in one pig (12.5 %, n = 1). Logistic regression model analysis showed the cryoprobe-spinal canal (Cp-Sc) distance as the most efficient parameter to categorize spinal canal temperatures lower than 19 °C (p<0.004), with a significant Pearson’s correlation test (p < 0.041) between the Cp-Sc distance and the lowest spinal canal temperatures. Ablation zones encompassed pedicles and the posterior wall of the vertebral bodies with an inflammatory rim, although no inflammatory infiltrate was depicted in the surrounding neural structures at light microscopy. Ultrastructural analyses evidenced myelin sheath disruption in some large nerve fibers, although neurological deficits were not observed. Conclusions CBCT-guided vertebral cryoablation of the porcine spine is feasible under a combination of a short freezing protocol and protective measures to the surrounding nerves. Ultrastructural analyses may be helpful assess the early modifications of the nerve fibers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study evaluated the functional and quantitative differences between the early and delayed use of phototherapy in crushed median nerves. After a crush injury, low-level laser therapy (GaAs) was applied transcutaneously at the injury site, 3 min daily, with a frequency of five treatments per week for 2 weeks. In the early group, the first laser treatment started immediately after surgery, and in the delayed group, after 7 days. The grasping test was used for functional evaluation of the median nerve, before, 10, and 21 days after surgery, when the rats were killed. Three segments of the median nerve were analyzed histomorphometrically by light microscopy and computer analysis. The following features were observed: myelinated fiber and axon diameters, myelin sheath area, g-ratio, density and number of myelinated fibers, and area and number of capillaries. In the proximal segment (site of crush), the nerves of animals submitted to early and delayed treatment showed myelinated fiber diameter and myelin sheath area significantly larger compared to the untreated group. In the distal segment, the myelin sheath area was significantly smaller in the untreated animals compared to the delayed group. The untreated, early, and delayed groups presented a 50, 57, and 81% degree of functional recovery, respectively, at 21 days after injury, with a significant difference between the untreated and delayed groups. The results suggest that the nerves irradiated with low-power laser exhibit myelinated fibers of greater diameter and a better recovery of function.