980 resultados para motor nerve conduction velocity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Our objective was to develop an experimental model for the noninvasive and objective evaluation of facial nerve regeneration in rats using a motor nerve conduction test (electromyography). Methods: Twenty-two rats were submitted to neurophysiological evaluation using motor nerve conduction of the mandibular branch of the facial nerve to obtain the compound muscle action potentials (CMAPs). To record the CM APs, we used two needle electrodes that were inserted into the lower lip muscle of the rat. A supramaximal electrical stimulus was applied, and the values of CMAP latency, amplitude, length, area, and stimulus intensity obtained from each side were compared by use of the Wilcoxon test. Results: There was no significant difference (all p > 0.05) in latency, amplitude, duration, area, or intensity of stimuli between the two sides. The amplitudes ranged between 1.61 and 8.30 mV, the latencies between 1.03 and 1.97 ms, and the stimulus intensities between 1.50 and 2.90 mA. Conclusions: This is a noninvasive, easy, and highly reproducible method that contributes to an improvement of the techniques previously described and may contribute to future studies of the degeneration and regeneration of the facial nerve.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[EN] OBJECTIVES: To assess the usefulness of clinical findings, nerve conduction studies and ultrasonography performed by a rheumatologist to predict success in patients with idiopathic carpal tunnel syndrome (CTS) undergoing median nerve release. METHODS: Ninety consecutive patients with CTS (112 wrists) completed a specific CTS questionnaire and underwent physical examination and nerve conduction studies. Ultrasound examination was performed by a rheumatologist who was blind to any patient's data. Outcome variables were improvement >25% in symptoms of the CTS questionnaire and patient's overall satisfaction (5-point Likert scale) at 3 months postoperatively. Success was defined as improvement in both outcome variables. Receiver operating characteristics (ROC) curves and logistic regression analyses were used to assess the best predictive combination of preoperative findings. RESULTS: Success was achieved in 63% of the operated wrists. Utility parameters and area under the ROC curve (AUC) for individual findings was poor, ranging from 0.481 of the nerve conduction study to 0.634 of the cross-sectional area at tunnel outlet. Logistic regression identified the preoperative US parameters as the best predictive variables for success after 3 months. The best predictive combination (AUC=0.708) included a negative Phalen maneuver, plus absence of thenar atrophy, plus less than moderately abnormalities on nerve conduction studies plus a large maximal cross-sectional area along the tunnel by ultrasonography. CONCLUSION: Although cross-sectional area of the median nerve was the only predictor of success after three months of surgical release, isolated preoperative findings are not reliable predictors of success in patients with idiopathic CTS. A combination of findings that include ultrasound improves prediction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study we sought to evaluate the reproducibility of sensory nerve conduction studies (NCS) using ultrasound-guided needle positioning (USNP).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the usefulness of ultrasound imaging to improve the positioning of the recording needle for nerve conduction studies (NCS) of the sural nerve. METHODS: Orthodromic NCS of the sural nerve was performed in 44 consecutive patients evaluated for polyneuropathy. Ultrasound-guided needle positioning (USNP) was compared to conventional "blind" needle positioning (BNP), electrically guided needle positioning (EGNP), and to recordings with surface electrodes (SFN). RESULTS: The mean distance between the needle tip and the nerve was 1.1 mm with USNP compared to 5.1 mm with BNP (p<0.0001). The mean amplitude of the sensory nerve action potential (SNAP) was 21 microV with USNP and 11 microV with BNP (p<0.0001). Compared to BNP, nerve-needle distances and SNAP amplitudes did not improve with EGNP. SNAP amplitudes recorded with SFN were significantly smaller than with BNP, EGNP and USNP. CONCLUSION: Ultrasound increases the precision of needle positioning markedly, compared to conventional methods. The amplitude of the recorded SNAP is usually clearly greater using USNP. In addition, USNP is faster, less painful and less dependent on the patient. SIGNIFICANCE: USNP is superior to BNP, EGNP, and SFN in accurate measurement of SNAP amplitude. It has a potential use in the routine near-nerve needle sensory NCS of pure sensory nerves.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION The aim of this study was to compare orthodromic sural nerve conduction study (NCS) results using ultrasound-guided needle positioning (USNP) to surface electrode recordings. METHODS 51 healthy subjects aged 24 - 80 years, divided into 5 age groups, were examined. Electrical stimuli were applied behind the lateral malleolus. Sensory nerve action potentials (SNAPs) were recorded 8 and 15 cm proximally with surface and needle electrodes. RESULTS Mean SNAP amplitudes in µV (surface/needle electrodes) averaged 12.7 (SD 7.6)/40.6 (SD 20.8), P<0.001, for subjects aged 20-29 years, and 5.0 (SD 2.4)/19.8 (SD 9.8), P<0.01, for subjects aged > 60 years. SNAP amplitudes were smaller at the proximal recording location. DISCUSSION NCS using USNP yield higher amplitude responses than surface electrodes in all age groups at all recording sites. SNAP amplitudes are smaller at proximal recording locations due to sural nerve branching. This article is protected by copyright. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Previous work has shown that the fluorescent styryl dye FM1-43 stains nerve terminals in an activity-dependent fashion. This dye appears to label the membranes of recycled synaptic vesicles by being trapped during endocytosis. Stained terminals can subsequently be destained by repeating nerve stimulation in the absence of dye; the destaining evidently reflects escape of dye into the bathing medium from membranes of exocytosing synaptic vesicles. In the present study we tested two key aspects of this interpretation of FM1-43 behavior, namely: (i) that the dye is localized in synaptic vesicles, and (ii) that it is actually released into the bathing medium during destaining. To accomplish this, we first photolyzed the internalized dye in the presence of diaminobenzidine. This created an electron-dense reaction product that could be visualized in the electron microscope. Reaction product was confined to synaptic vesicles, as predicted. Second, using spectrofluorometry, we quantified the release of dye liberated into the medium from tubocurarine-treated nerve-muscle preparations. Nerve stimulation increased the amount of FM1-43 released, and we estimate that normally a stained synaptic vesicle contains a few hundred molecules of the dye. The key to the successful detection of released FM1-43 was to add the micelle-forming detergent 3-[(3-cholamidopropyl)dimethylammonio]-1-propanesulfonate (CHAPS), which increased FM1-43 quantum yield by more than two orders of magnitude.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nerve sprouts emerge from motor nerve terminals following blockade of exo-endocytosis for more than 3 days by botulinum neurotoxin (BoNT), and form functional synapses, albeit temporary. Upon restoration of synaptic activity to the parent terminal 7 and 90 days after exposure to BoNT/F or A respectively, a concomitant retraction of the outgrowths was observed. BoNT/E caused short-term neuroparalysis, and dramatically accelerated the recovery of BoNT/A-paralyzed muscle by further truncation of SNAP-25 and its replenishment with functional full-length SNARE. The removal of 9 C-terminal residues from SNAP-25 by BoNT/A leads to persistence of the inhibitory product due to the formation of a nonproductive SNARE complex(es) at release sites, whereas deletion of a further 17 amino acids permits replenishment and a speedy recovery. (C) 2003 Elsevier Science (USA). All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study examined the effect of prolonged inactivity, associated with aestivation, on neuromuscular transmission in the green-striped burrowing frog, Cyclorana alboguttata. We compared the structure and function of the neuromuscular junctions on the iliofibularis muscle from active C. alboguttata and from C. alboguttata that had been aestivating for 6 months. Despite the prolonged period of immobility, there was no significant difference in the shape of the terminals (primary, secondary or tertiary branches) or the length of primary terminal branches between aestivators and non-aestivators. Furthermore, there was no significant difference in the membrane potentials of muscle fibres or in miniature end plate potential (EPP) frequency and amplitude. However, there was a significant decrease in evoked transmitter release characterised by a 56% decrease in mean EPP amplitude, and a 29% increase in the failure rate of nerve terminal action potentials to evoke transmitter release. The impact of this suite of neuromuscular characteristics on the locomotor performance of emergent frogs is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE This study determined if deficits in corneal nerve fiber length (CNFL) assessed using corneal confocal microscopy (CCM) can predict future onset of diabetic peripheral neuropathy (DPN). RESEARCH DESIGN AND METHODS CNFL and a range of other baseline measures were compared between 90 nonneuropathic patients with type 1 diabetes who did or did not develop DPN after 4 years. The receiver operator characteristic (ROC) curve was used to determine the capability of single and combined measures of neuropathy to predict DPN. RESULTS DPN developed in 16 participants (18%) after 4 years. Factors predictive of 4-year incident DPN were lower CNFL (P = 0.041); longer duration of diabetes (P = 0.002); higher triglycerides (P = 0.023); retinopathy (higher on the Early Treatment of Diabetic Retinopathy Study scale) (P = 0.008); nephropathy (higher albumin-to-creatinine ratio) (P = 0.001); higher neuropathy disability score (P = 0.037); lower cold sensation (P = 0.001) and cold pain (P = 0.027) thresholds; higher warm sensation (P = 0.008), warm pain (P = 0.024), and vibration (P = 0.003) thresholds; impaired monofilament response (P = 0.003); and slower peroneal (P = 0.013) and sural (P = 0.002) nerve conduction velocity. CCM could predict the 4-year incident DPN with 63% sensitivity and 74% specificity for a CNFL threshold cutoff of 14.1 mm/mm2 (area under ROC curve = 0.66, P = 0.041). Combining neuropathy measures did not improve predictive capability. CONCLUSIONS DPN can be predicted by various demographic, metabolic, and conventional neuropathy measures. The ability of CCM to predict DPN broadens the already impressive diagnostic capabilities of this novel ophthalmic marker.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: In vivo corneal confocal microscopy (CCM) is increasingly used as a surrogate endpoint in studies of diabetic polyneuropathy (DPN). However, it is not clear whether imaging the central cornea provides optimal diagnostic utility for DPN. Therefore, we compared nerve morphology in the central cornea and the inferior whorl, a more distal and densely innervated area located inferior and nasal to the central cornea. METHODS: A total of 53 subjects with type 1/type 2 diabetes and 15 age-matched control subjects underwent detailed assessment of neuropathic symptoms (NPS), deficits (neuropathy disability score [NDS]), quantitative sensory testing (vibration perception threshold [VPT], cold and warm threshold [CT/WT], and cold- and heat-induced pain [CIP/HIP]), and electrophysiology (sural and peroneal nerve conduction velocity [SSNCV/PMNCV], and sural and peroneal nerve amplitude [SSNA/PMNA]) to diagnose patients with (DPN+) and without (DPN-) neuropathy. Corneal nerve fiber density (CNFD) and length (CNFL) in the central cornea, and inferior whorl length (IWL) were quantified. RESULTS: Comparing control subjects to DPN- and DPN+ patients, there was a significant increase in NDS (0 vs. 2.6 ± 2.3 vs. 3.3 ± 2.7, P < 0.01), VPT (V; 5.4 ± 3.0 vs. 10.6 ± 10.3 vs. 17.7 ± 11.8, P < 0.01), WT (°C; 37.7 ± 3.5 vs. 39.1 ± 5.1 vs. 41.7 ± 4.7, P < 0.05), and a significant decrease in SSNCV (m/s; 50.2 ± 5.4 vs. 48.4 ± 5.0 vs. 39.5 ± 10.6, P < 0.05), CNFD (fibers/mm2; 37.8 ± 4.9 vs. 29.7 ± 7.7 vs. 27.1 ± 9.9, P < 0.01), CNFL (mm/mm2; 27.5 ± 3.6 vs. 24.4 ± 7.8 vs. 20.7 ± 7.1, P < 0.01), and IWL (mm/mm2; 35.1 ± 6.5 vs. 26.2 ± 10.5 vs. 23.6 ± 11.4, P < 0.05). For the diagnosis of DPN, CNFD, CNFL, and IWL achieved an area under the curve (AUC) of 0.75, 0.74, and 0.70, respectively, and a combination of IWL-CNFD achieved an AUC of 0.76. CONCLUSIONS: The parameters of CNFD, CNFL, and IWL have a comparable ability to diagnose patients with DPN. However, IWL detects an abnormality even in patients without DPN. Combining IWL with CNFD may improve the diagnostic performance of CCM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A physiological experiment was carried out in a naturally ventilated, non-HVAC indoor environment of a spacious experimental room. More than 300 healthy university students volunteered for this study. The purpose of the study was to investigate the human physiological indicators which could be used to characterise the indoor operative temperature changes in a building and their impact on human thermal comfort based on the different climatic characteristics people would experience in Chongqing, China. The study found that sensory nerve conduction velocity (SCV) could objectively provide a good indicator for assessment of the human response to changes in indoor operative temperatures in a naturally ventilated situation. The results showed that with the changes in the indoor operative temperatures, the changing trend in the nerve conduction velocity was basically the same as that of the skin temperature at the sensory nerve measuring segment (Tskin(scv)). There was good coherent consistency among the factors: indoor operative temperature, SCV and Tskin(scv) in a certain indoor operative temperature range. Through self-adaptation and self-feedback regulation, the human physiological indicators would produce certain adaptive changes to deal with the changes in indoor operative temperature. The findings of this study should provide the baseline data to inform guidelines for the development of thermal environment-related standards that could contribute to efficient use of energy in buildings in China.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate modifications occurring in semitendinous muscle after transposition as a ventral perineal muscle flap using electromyography, ultrasonography, and morphological studies. Ten male crossbreed dogs of 3-4 year old were used. The left semitendinous muscle was cut close to the popliteus lymph node, rotated and sutured at the perineal region. The contralateral muscle was considered as control. Motor nerve conduction studies of both sciatic-tibial nerves, and electromyographic and ultrasonographic examinations of both semitendinous muscles were performed before surgery and 15, 30, 60, and 90 days postoperatively. Semitendinous muscle samples were collected for morphological analysis 90 days after surgery. No alterations were observed in clinical gait examinations, or in goniometrical and electroneuromyographical studies in pelvic limbs after surgery. Electromyography demonstrated that the transposed muscle was able to contract, but atrophy was detected by ultrasonography and morphological analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente trabalho teve como objetivo a padronização dos valores de referência de velocidade de condução nervosa sensitiva dos nervos tibial e peroneal em cães clinicamente sadios, pela utilização de eletrodos de superfície. em todos os sítios de estimulação, captação, referência e terra foram utilizados eletrodos do tipo jacaré, exceto na captação do estímulo no nervo peroneal, próximo à articulação fêmur-tibial, onde o registro só foi possível com a utilização de eletrodo de agulha. Foram utilizados 30 cães, 11 machos e 19 fêmeas, sem raça definida, com idade entre dois e seis anos. Os valores médios das medidas dos potenciais evocados pela estimulação sensitiva dos nervos tibial e peroneal foram: latência inicial, 1,82±0,30ms (1,30 a 2,55ms) e 1,57±0,29ms (1,01 a 2,16ms), amplitude de pico a pico, 96,48±45,78miV (41,6 a 214miV) e 121,25±57,49miV (54,8 a 299miV) e duração, 1,97±0,69ms (1,01 a 3,56ms) e 2,37±0,85ms (1,11 a 3,94ms), respectivamente. Os valores médios das medidas de velocidade de condução nervosa sensitiva dos nervos tibial e peroneal foram, respectivamente, 62,14+7,71ms (50,0 a 77,2ms) e 65,18+6,42ms (53,8 a 79,2ms), respectivamente.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

São revisados os trabalhos que, a partir de 1975,estudaram a ocorrência de manifestações neurológicas centrais e periféricas em trabalhadores ocupacionalmente expostos ao chumbo, que apresentavam níveis de exposição supostamente insuficientes para causarem Saturnismo. A partir da revisão realizada é sugerido que os limites de tolerância biológica utilizados em nosso meio para firmar o diagnóstico de intoxicação profissional pelo chumbo devam ser revistos. Tal sugestão baseia-se na existência de evidências bem estabelecidas que apontam disfunções da condução nervosa periférica e central, além de alterações de várias funções nervosas superiores, em trabalhadores profissionalmente expostos ao chumbo que apresentam indicadores de efeito biológico e indicadores de exposição inferiores aos limites estabelecidos pela legislação brasileira.