961 resultados para medullary canal diameter


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The limb amputation is one of the oldest surgical procedures performed and it still represents an event that drastically changes the life of an individual. Despite the technological progress, the difficulties related to the realization and daily use of the socket remain very common. Among the different technologies adopted in the prosthetic field, this project focused on the osseointegration technique. This technique consists in implanting a stem within the medullary canal of the amputated skeletal segment that extends outside the amputation stump with a prosthesis, later connected to the metal extension. The objective of this PhD project is to treat and to evaluate selected patients with osseointegrated prosthetic implants for the treatment of lower limb amputations. Patients are recruited at the Rizzoli Orthopaedic Institute and at the Prosthesis - INAIL center of Vigorso (Budrio) during outpatient visits, while the surgical procedure is performed by the same expert surgeon in the II Orthopaedic and Traumatology Clinic of the Rizzoli Orthopaedic Institute. The project is still ongoing, to date three patients had completed both procedures, but due to various personal problems, just one of them is included in the analysis. This patient increased his percentage of prosthesis use and the level of mobility with an overall improvement of quality of live after the procedure. The osseointegration technique represents a promising alternative method of treatment for amputees who are not satisfied with their socket prosthesis. In the coming years it will continue the collection of clinical, radiographic and kinematic data of subjects undergoing this procedure in order to perform a long-term monitoring of both clinical outcomes and quality of life.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Lower limb amputation is an event that inevitably changes the lifestyle of the person with a significant impact on quality of life. The socket-type prosthesis entails that the residual limb is in direct contact with the socket which often implies numerous disadvantages. Osseointegrated prosthesis is a solution that avoids skin problems because not include the presence of the socket. In this type of prosthesis, a stem is surgically inserted inside the medullary canal and connected with the external prosthetic limb. Therefore, this thesis aims to highlight and explore the main strengths and problems of osseointegrated prostheses and to examine the role of physical activity, with attention to functional capacity and bone quality. The objectives of the thesis will be developed through 5 studies: (I) A gait analysis of a 44 years-old male patient who underwent surgery for the implantation of an osseointegrated prosthesis; (II) A systematic review to investigate the state of stump bone quality in patients with limb amputations; (III) A systematic review of the technologies involved in such devices has been carried out to identify the most fruitful ones in improving bone quality; (IV) A systematic review investigating the topic of physical activity and bone turnover biomarkers; (V) A systematic review to investigate the effects of physical activity interventions combined with drug treatments on bone biomarkers in people with osteopenia and osteoporosis. The integrated prosthesis is a good solution for people with lower limb amputation who cannot use their traditional socket-type prosthesis. Although many objectives have already been achieved, there are still many aspects that we can improve. These include the creation of a multidisciplinary path that support patients along their path, with particular attention to the pre-surgery and the post-rehabilitation phase that is still lacking even if of fundamental impact in determining the quality of life.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated in vitro the antibacterial activity of 4 root canal filling materials for primary teeth - zinc oxide and eugenol cement (ZOE), Calen paste thickened with zinc oxide (Calen/ZO), Sealapex sealer and EndoREZ sealer - against 5 bacterial strains commonly found in endodontic infections (Kocuria rhizophila, Enterococcus faecalis, Streptococcus mutans, Escherichia coli and Staphylococcus aureus) using the agar diffusion test (agar-well technique). Calen paste, 1% chlorhexidine digluconate (CHX) and distilled water served as controls. Seven wells per dish were made at equidistant points and immediately filled with the test and control materials. After incubation of the plates at 37oC for 24 h, the diameter of the zones of bacterial growth inhibition produced around the wells was measured (in mm) with a digital caliper under reflected light. Data were analyzed statistically by analysis of variance and Tukey's post-hoc test (?=0.05). There were statistically significant differences (p<0.0001) among the zones of bacterial growth inhibition produced by the different materials against all target microorganisms. K. rhizophila was inhibited more effectively (p<0.05) by ZOE, while Calen/ZO had its highest antibacterial activity against E. faecalis (p<0.05). S. mutans was inhibited by Calen/ZO, Sealapex and ZOE in the same intensity (p>0.05). E. coli was inhibited more effectively (p<0.05) by ZOE, followed by Calen/ZO and Sealapex. Calen/ZO and ZOE were equally effective (p>0.05) against S. aureus, while Sealapex had the lowest antibacterial efficacy (p<0.05) against this microorganism. EndoREZ presented antibacterial activity only against K. rhizophila and S. aureus. The Calen paste and Calen/ZO produced larger zones of inhibition than 1% CHX when the marker microorganism was E faecalis. In conclusion, the in vitro antibacterial activity of the 4 root canal filling materials for primary teeth against bacterial strains commonly found in endodontic infections can be presented in a decreasing order of efficacy as follows: ZOE>Calen/ZO>Sealapex>EndoREZ.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a case report of a left mandibular second premolar with three canals and three different apical foramina. A 39-year-old male patient presented to our clinic with pain in the mandibular left second premolar. Initially, pain was caused by cold stimulus and later was spontaneously. The intraoral clinical examination revealed a fractured amalgam restoration with occlusal caries. Percussion and cold (Endo-Frost) tests were positive. The radiographic examination showed the presence of two roots. The probable diagnosis was an acute pulpitis. After access cavity, it was observed remaining roof of the pulp chamber and mild bleeding in the tooth lingual area, indicating the possible presence of a third canal. The endodontic treatment was completed in a single session using Root ZX apex locator and K3 NiTi rotary system with surgical diameter corresponding to a .02/45 file in the three canals and irrigation with 1% sodium hypochlorite. The canals were obtured with gutta-percha cones and Sealer 26 using the lateral condensation technique. After 1 year of follow-up, the tooth was asymptomatic and periapical repair was observed radiographically. Internal alterations should be considered during the endodontic treatment of mandibular second premolars. The correct diagnosis of these alterations by the analysis of preoperative radiographs can help the location of two or more canals, thereby avoiding root therapy failure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. Total thyroidectomy (TT) with level VI and VII central neck dissection is the initial treatment for medullary thyroid carcinoma (MTC) without identifiable neck metastasis. Level II to V lateral neck dissection is performed if neck metastasis is present or suspected. We conducted this study to identify the frequency and clinical determinants of skip neck metastasis in MTC. Methods. We reviewed the medical records of 32 patients who underwent TT and bilateral neck dissection for MTC. The clinical features were correlated with pN status in the central versus lateral compartments of the neck. Results. Neck lymph node metastasis (pN+) was found in 20 patients (62.5%) and skip metastases were found in 7 (35%) patients. The sensitivity of the pN status of the central compartment of the neck to predict the pN status of the lateral compartment of the neck was 53.8% and specificity was 63.2%. We found pN+ in 90% of the patients with lymph nodes > 15mm in diameter versus 50% in those with lymph nodes < 1.5mm in diameter. Conclusions. There is skip metastasis in MTC. It is unsafe to use the lymph node status of the central compartment of the neck to define the pN status of the lateral neck. A lymph node greater than 15 mm in diameter is related to pN status.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: A study was made to determine the temperature increment at the dental root surface following Er,Cr:YSGG laser irradiation of the root canal. Design. Human canines and incisors previously instrumented to K file number ISO 30 were used. Irradiation was carried out with glass fiber endodontic tips measuring 200 μm in diameter and especially designed for insertion in the root canal. The teeth were irradiated at 1 and 2 W for 30 seconds, without water spraying or air, and applying a continuous circular movement (approximately 2 mm/sec.) in the apico-coronal direction. Results: At the 1 W power setting, the mean temperature increment was 3.84ºC versus 5.01ºC at 2 W. In all cases the difference in mean value obtained after irradiation versus the mean baseline temperature proved statistically significant (p< 0.05). Conclusions: Application of the Er,Cr:YSGG laser gives rise to a statistically significant temperature increment at the external root surface, though this increment is probably clinically irrelevant, since it would appear to damage the tissues (periodontal ligament and alveolar bone) in proximity to the treated tooth

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effectiveness of different light-curing units on the bond strength (push-out) of glass fiber posts in the different thirds of the root (cervical, middle and apical) with different adhesive luting resin systems (dual-cure total-etch; dual-cured and self-etch bonding system; and dual-cure self-adhesive cements), Disks of the samples (n = 144) were used, with approximately 1 mm of thickness of 48 bovine roots restored with glass fiber posts, that were luted with resin cements photo-activated by halogen LCU (QTH, Optilux 501) and blue LED (Ultraled), with power densities of 600 and 550 mW/cm(2), respectively. A universal testing machine (MTS 810 Material Test System) was used with a 1 mm diameter steel rod at cross-head speed of 0.5 mm/min until post extrusion, with load cell of 50 kg, for evaluation of the push-out strength in the different thirds of each sample. The push-out strength values in kgf were converted to MPa and analyzed through Analysis of Variance and Tukey`s test, at significance level of 5%. The results showed that there were no statistical differences between the QTH and LED LCUs. The self-adhesive resin cement had lower values of retention. The total-etch and self-adhesive system resin cements seem to be a possible alternative for glass fiber posts cementation into the radicular canal and the LED LCU can be applied as an alternative to halogen light on photo-activation of dual-cured resin cements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Este estudo avaliou o escoamento do Acroseal, AH Plus, Endomethasone N, Sealapex e ActiV GP de acordo com a especificação ISO 6876/2001. METODOLOGIA: Um volume de 0,05 mL do cimento manipulado de acordo com as recomendações do fabricante foi colocado numa placa de vidro. Aos 180±5 s após o início da espatulação, uma segunda placa de vidro foi colocada sobre o cimento, seguida por um peso de massa de 100 g para fazer um total de 120±2 g. Dez minutos após o começo da manipulação o peso foi removido e o valor do diâmetro do disco de cimento foi mensurado. A média de 3 mensurações para cada cimento foi tomada como o escoamento do material. Os dados foram comparados estatisticamente pelos testes ANOVA e Tukey. RESULTADOS: Os escoamentos obtidos foram: Acroseal 21.,4 mm, AH Plus 22,72 mm, ActiV GP 24,90 mm, Endomethasone N 18,76 mm e Sealapex 25,15 mm. CONCLUSÃO: Apenas o Endomethasone N não se enquadrou na especificação ISO a qual requer que o cimento tenha um diâmetro não inferior a 20 mm. O Sealapex alcançou o melhor escoamento, mas não foi estatisticamente diferente do Activ GP e AH Plus (P>0,05).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The calcium hydroxide ionization of four root canal sealers (Sealapex, CRCS, Sealer 26, and Apexit) was studied by measuring conductivity and pH and by conducting atomic absorption spectrophotometry. Samples 6 mm in diameter and 15 mm long were prepared from these sealers. After setting and 48 h storage in a desiccator, five samples of each material were placed in 50 mL distilled water and analysed after 0,1,2,4, 6 and 24 h and 5, 15 and 30 days. The results showed that Sealapex was the root canal sealer showing the highest pH, ionic calcium and total calcium values (P<0.05) throughout the experimental period, followed by CRCS, Apexit and Sealer 26.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effectiveness of different light-curing units on the bond strength (push-out) of glass fiber posts in the different thirds of the root (cervical, middle and apical) with different adhesive luting resin systems (dual-cure total-etch; dual-cured and self-etch bonding system; and dual-cure self-adhesive cements), Disks of the samples (n = 144) were used, with approximately 1 mm of thickness of 48 bovine roots restored with glass fiber posts, that were luted with resin cements photo-activated by halogen LCU (QTH, Optilux 501) and blue LED (Ultraled), with power densities of 600 and 550 mW/cm 2, respectively. A universal testing machine (MTS 810 Material Test System) was used with a 1 mm diameter steel rod at cross-head speed of 0.5 mm/min until post extrusion, with load cell of 50 kg, for evaluation of the push-out strength in the different thirds of each sample. The push-out strength values in kgf were converted to MPa and analyzed through Analysis of Variance and Tukey's test, at significance level of 5%. The results showed that there were no statistical differences between the QTH and LED LCUs. The self-adhesive resin cement had lower values of retention. The total-etch and self-adhesive system resin cements seem to be a possible alternative for glass fiber posts cementation into the radicular canal and the LED LCU can be applied as an alternative to halogen light on photo-activation of dual-cured resin cements. © 2009 Pleiades Publishing, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FMVZ

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The irrigation of root canals aims to their cleaning and disinfection, improving endodontic treatment success. Objective: To investigate the influence of the diameter and type of irrigation needle and the root canal enlargement on the mechanical efficacy of endodontic irrigation. Material and methods: Twelve human single-rooted mandibular incisors were used. During some instrumentation stages (enlargement by #20, #30, and #40 K file), root canals were filled with radiographic contrast solution mixed to propyleneglycol and zinc oxide. Needles with different diameters and designs were employed: G1 – 23G and lateral opening; G2 – 22G and apical opening; G3 – 30G and lateral opening; G4 – 30G and apical opening. The needles were inserted up to resistance, with 1 mm step-back to avoid root canal obliteration. The irrigation was performed with 2 mL of distilled water. Before and after irrigation/aspiration, teeth were radiographed at bucco-lingual and mesiodistal direction, using a digital radiographic system. Then, root canal areas, before (filled by contrast solution) and after irrigation (remnant of contrast solution), were submitted to image subtraction with Adobe Photoshop CS4 software. Subsequently, the areas were measured by Image Tool 3.0 software, allowing the obtaining of the cleaning percentage for each modality. Data were analysed by using Anova and Tukey’s test. The level of significance was set at P < 0.05. Results: For all root canal enlargements, 30G needles (G3 e G4) presented a better cleaning efficacy. In all groups, higher cleaning efficacy percentage was observed at #30 and #40 K file enlargement. Conclusion: Regardless their design, thinner needles were more effective; a better cleaning efficacy occurred in more enlarged root canals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The aim of the present study was to evaluate the physicochemical properties of a bioceramic root canal sealer, Endosequence BC Sealer. Radiopacity, pH, release of calcium ions (Ca2+), and flow were analyzed, and the results were compared with AH Plus cement. Methods: Radiopacity and flow were evaluated according to ISO 6876/2001 standards. For the radiopacity analysis, metallic rings with 10-mm diameter and 1-mm thickness were filled with cements. The radiopacity value was determined according to radiographic density (mm Al). The flow test was performed with 0.05 mL of cement placed on a glass plate. A 120-g weight was carefully placed over the cement. The largest and smallest diameters of the disks formed were measured by using a digital caliper. The release of Ca2+ and pH were measured at periods of 3, 24, 72, 168, and 240 hours with spectrophotometer and pH meter, respectively. Data were analyzed by analysis of variance and Tukey test (P < .05). Results: The bioceramic endodontic cement showed radiopacity (3.84 mm Al) significantly lower than that of AH Plus (6.90 mm Al). The pH analysis showed that Endosequence BC Sealer showed pH and release of Ca2+ greater than those of AH Plus (P < .05) during the experimental periods. The flow test revealed that BC Sealer and AH Plus presented flow of 26.96 mm and 21.17 mm, respectively (P < .05). Conclusions: Endosequence BC Sealer showed radiopacity and flow according to ISO 6876/2001 recommendations. The other physicochemical properties analyzed demonstrated favorable values for a root canal sealer. (J Endod 2012;38:842-845)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The neurovascular bundle may be vulnerable during surgical procedures involving the mandible, especially when anatomical variations are present. Increased demand of implant surgeries, wider availability of three-dimensional exams, and lack of clear definitions in the literature indicate that features of anatomical variations should be revisited. The objective of the study was to evaluate features of anatomical variations related to mandibular canal (MC), such as bifid canals, anterior loop of mental nerve, and corticalization of MC. Additionally, bone trabeculation at the submandibular gland fossa region (SGF) was assessed and related to visibility of MC. Cone beam computed tomography exams from 100 patients (200 hemimandibles) were analyzed and the following parameters were registered: diameter and corticalization of MC; trabeculation in SGF region; presence of bifid MC, position of bifurcations, diameter, and direction of bifid canals; and measurement of anterior loops by two methods. Corticalization of the MC was observed in 59% of hemimandibles. In 23%, MC could be identified despite absence of corticalization. Diameter of MC was between 2.1 and 4 mm for nearly three quarters of the sample. In 80% of the sample trabeculation at the SGF was either decreased or not visible, and such cases showed correlation with absence of MC corticalization. Bifid MC affected 19% of the patients, mostly associated with additional mental foramina. Clinically significant anterior loop (> 2 mm of anterior extension) was observed in 22-28%, depending on the method. Our findings, together with previously reported limitations of conventional exams, draw attention to the unpredictability related to anatomical variations in neurovascularization, showing the contribution of individual assessment through different views of three-dimensional imaging prior to surgical procedures in the mandible.