950 resultados para median arterial pressure


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of intravenous infusion of hypertonic saline (HS, 7.5% NaCl) on the recovery of mean arteria pressure (MAP) after hemorrhage was studied in sham-operated rats and in rats with electrolytic lesion of the anteroventral third ventricle (AV3V) region (4 h, 4 and 20 days). Rats anesthetized with thiopental sodium were bled (about 2.8 ml/100 g) until the MAP was stabilized at the level of 60 mmHg for 30 min. In sham-lesioned rats, MAP increased to 90 mmHg and became stable near this level after intravenous infusion of 7.5% NaCl (4 ml/kg b.wt.). In AV3V-lesioned rats, the same infusion induced a smaller increase in MAP (80 mmHg) and the MAP returned to pre-infusion levels within 30 min. These results show that the AV3V region plays an important role in the recovery of arterial pressure induced by hypertonic saline in rats submitted to hemorrhagic shock.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cardiovascular responses to central losartan (LOS), a non-peptide angiotensin II (ANG II) receptor antagonist, were investigated by comparing the effects of LOS injection into the 3rd and 4th cerebral ventricles (3rdV, 4thV) on mean arterial pressure (MAP) and heart rate (HR). Adult male Holtzman rats were used (N = 6 animals per group). Average basal MAP and HR were 114 +/- 3 mmHg and 343 +/- 9 bpm (N = 23), respectively. LOS (50, 100 or 200 nmol/2 mu l) injected into the 3rdV induced presser (peak of 25 +/- 3 mmHg) and tachycardic (peak of 60 +/- 25 bpm) responses. LOS injected into the 4thV had no effect on MAP, but it induced bradycardia (peak of -35 +/- 15 bpm). KCl (200 nmol/2 mu l) injected into the 3rdV or into the 4thV had no effect on either MAP or HR compared to 0.9% saline injection. The results indicate that LOS injected into the third ventricle acts on forebrain structures to induce its presser and tachycardic effects and that bradycardia, likely dependent on hindbrain structures, is obtained when LOS is injected into the fourth ventricle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

1. Water intake induced by injection of 0.2 M-NaCl into the lateral preoptic area was increased by the injection of angiotensin II into the subfornical organ of rats. The injection of hypertonic saline solution into the subfornical organ increased water intake. However, the increase was lower than when the solution was injected into the lateral preoptic area. The injection of 4 μg angiotensin II into the lateral preoptic area further augmented this effect. 2. Injection of angiotensin II into the subfornical organ caused a rise in blood pressure which preceded the thirst-inducing effect. The injection of 0.2 M NaCl into the subfornical organ caused no changes in blood pressure, whereas the injection of angiotensin II into the lateral preoptic area caused some increase. 3. Dehydration of the lateral preoptic area by means of 0.2 M NaCl in combination with intravenous infusion of angiotensin II caused a summation of effects in terms of the water intake, without changing cardiovascular alterations induced by the infusion of angiotensin II. A summation of effects in the water intake, but not in blood pressure, was also observed when 0.5 M NaCl was infused intravenously in combination with the injection of angiotensin II into the subfornical organ and into the lateral preoptic area. 4. The results indicate that there are interactions between the subfornical organ and lateral preoptic area in the regulation of cardiovascular and thirst mechanisms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cardiovascular responses to central losartan (LOS), a non-peptide angiotensin II (ANG II) receptor antagonist, were investigated by comparing the effects of LOS injection into the 3rd and 4th cerebral ventricles (3rdV, 4thV) on mean arterial pressure (MAP) and heart rate (HR). Adult male Holtzman rats were used (N=6 animals per group). Average basal MAP and HR were 114±3 mmHg and 343±9 bpm (N=23), respectively. LOS (50, 100 or 200 nmol/2 μl) injected into the 3rdV induced pressor (peak of 25±3 mmHg) and tachycardic (peak of 60±25 bpm) responses. LOS injected into the 4thV had no effect on MAP, but it induced bradycardia (peak of -35±15 bpm). KCl (200 nmol/2 μl) injected into the 3rdV or into the 4thV had no effect on either MAP or HR compared to 0.9% saline injection. The results indicate that LOS injected into the third ventricle acts on forebrain structures to induce its pressor and tachycardic effects and that bradycardia, likely dependent on hindbrain structures, is obtained when LOS is injected into the fourth ventricle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Angiotensin II (Ang II) non-peptide antagonists were injected i.c.v. (6.25-200 nmol, n = 5-8 rats/group): In sodium replete rats, losartan (AT1 receptor antagonist) induced an increase in mean arterial pressure (MAP) and in heart rate (HR) by 3rd ventricular (3rdV) injection, and a weaker pressor response and bradycardia by 4th ventricular (4thV) injection. PD123319 (AT2 receptor antagonist) induced an increase in MAP and in HR by 3rdV injection, and an increase in MAP and no alteration in HR by 4thV injection. In sodium deplete (furosemide plus removal of ambient sodium for 24 h) rats, losartan induced an increase in MAP and no alteration in HR by 3rdV injection, and no alteration in MAP and bradycardia by 4thV injection. PD123319 induced an increase in MAP and in HR by 3rdV injection, and an increase in MAP and bradycardia by 4thV injection. Thus, there was no fall in MAP by central injections of Ang II antagonists. Intravenous injection of losartan, but not of PD123319, induced a fall in MAP in both sodium replete and sodium deplete animals. Therefore, losartan and PD123319 can have similar effects on MAP and HR when injected intracerebroventricularly, although some differences are also present. The bradycardia is consistent with an withdrawal of Ang II inhibitory action on baroreflex.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several studies have demonstrated that one exercise session (ES) on a cycloergometer or ergometric treadmill causes a reduction in blood pressure (BP). However, there are few similar studies on walking, which is the exercise modality most available to the elderly. We investigated the immediate and 24-h effects of walking on BP in independent, community-living elderly individuals. Volunteers participated in a single ES and resting control session (CS). Before and after each session, BP was measured by auscultatory and oscillometric methods. After each session, 24-h ambulatory blood pressure monitoring was conducted. An accelerometer was installed 48 h before the sessions and left in place for 5 days. The mean volunteer age was 67.7 +/- 3.5 years; 11 were hypertensive patients under treatment, and 12 were normotensive. In the total sample, there were immediate 14mm Hg and 12 mm Hg reductions in systolic BP (SBP) after the ES according to the auscultatory and oscillometric methods, respectively. Diastolic BP (DBP) was reduced by 4 mm Hg after the ES according to both methods. SBP during wakefulness and sleep and DBP during wakefulness were lower after the ES than after the CS (P<0.01), when wakefulness and sleep were determined individually (variable-time pattern) using data from the activity monitors and provided by the volunteers. The variable-time pattern was more effective in detecting reductions in BP than the fixed-time pattern. Hypertension Research (2012) 35, 457-462; doi: 10.1038/hr.2011.227; published online 9 February 2012

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Arterial pressure-based cardiac output monitors (APCOs) are increasingly used as alternatives to thermodilution. Validation of these evolving technologies in high-risk surgery is still ongoing. In liver transplantation, FloTrac-Vigileo (Edwards Lifesciences) has limited correlation with thermodilution, whereas LiDCO Plus (LiDCO Ltd.) has not been tested intraoperatively. Our goal was to directly compare the 2 proprietary APCO algorithms as alternatives to pulmonary artery catheter thermodilution in orthotopic liver transplantation (OLT). The cardiac index (CI) was measured simultaneously in 20 OLT patients at prospectively defined surgical landmarks with the LiDCO Plus monitor (CI(L)) and the FloTrac-Vigileo monitor (CI(V)). LiDCO Plus was calibrated according to the manufacturer's instructions. FloTrac-Vigileo did not require calibration. The reference CI was derived from pulmonary artery catheter intermittent thermodilution (CI(TD)). CI(V)-CI(TD) bias ranged from -1.38 (95% confidence interval = -2.02 to -0.75 L/minute/m(2), P = 0.02) to -2.51 L/minute/m(2) (95% confidence interval = -3.36 to -1.65 L/minute/m(2), P < 0.001), and CI(L)-CI(TD) bias ranged from -0.65 (95% confidence interval = -1.29 to -0.01 L/minute/m(2), P = 0.047) to -1.48 L/minute/m(2) (95% confidence interval = -2.37 to -0.60 L/minute/m(2), P < 0.01). For both APCOs, bias to CI(TD) was correlated with the systemic vascular resistance index, with a stronger dependence for FloTrac-Vigileo. The capability of the APCOs for tracking changes in CI(TD) was assessed with a 4-quadrant plot for directional changes and with receiver operating characteristic curves for specificity and sensitivity. The performance of both APCOs was poor in detecting increases and fair in detecting decreases in CI(TD). In conclusion, the calibrated and uncalibrated APCOs perform differently during OLT. Although the calibrated APCO is less influenced by changes in the systemic vascular resistance, neither device can be used interchangeably with thermodilution to monitor cardiac output during liver transplantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fluid optimization is a major contributor to improved outcome in patients. Unfortunately, anesthesiologists are often in doubt whether an additional fluid bolus will improve the hemodynamics of the patient or not as excess fluid may even jeopardize the condition. This article discusses physiological concepts of liberal versus restrictive fluid management followed by a discussion on the respective capabilities of various monitors to predict fluid responsiveness. The parameter difference in pulse pressure (dPP), derived from heart-lung interaction in mechanically ventilated patients is discussed in detail. The dPP cutoff value of 13% to predict fluid responsiveness is presented together with several assessment techniques of dPP. Finally, confounding variables on dPP measurements, such as ventilation parameters, pneumoperitoneum and use of norepinephrine are also mentioned.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Most medical implants run on batteries, which require costly and tedious replacement or recharging. It is believed that micro-generators utilizing intracorporeal energy could solve these problems. However, such generators do not, at this time, meet the energy requirements of medical implants.This paper highlights some essential aspects of designing and implementing a power source that scavenges energy from arterial expansion and contraction to operate an implanted medical device. After evaluating various potentially viable transduction mechanisms, the fabricated prototype employs an electromagnetic transduction mechanism. The artery is inserted into a laboratory-fabricated flexible coil which is permitted to freely deform in a magnetic field. This work also investigates the effects of the arterial wall's material properties on energy harvesting potential. For that purpose, two types of arteries (Penrose X-ray tube, which behave elastically, and an artery of a Göttinger minipig, which behaves viscoelastically) were tested. No noticeable difference could be observed between these two cases. For the pig artery, average harvestable power was 42 nW. Moreover, peak power was 2.38 μW. Both values are higher than those of the current state of the art (6 nW/16 nW). A theoretical modelling of the prototype was developed and compared to the experimental results.