964 resultados para localised corrosion


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose – To provide a summary of research work carried out mainly in the authors' group for evaluating various protective coatings including rustproofing oils, and also for studying corrosion inhibitors using the wire beam electrode (WBE) method.

Design/methodology/approach – A range of published papers published during the past 15 years was summarised and reviewed. Recent research work in the authors' group was also included, which involved the combined use of the WBE with electrochemical noise analysis and the scanning reference electrode technique.

Findings – The WBE method has been developed into a very useful tool of evaluating the performance of coatings and inhibitors. In particular, The WBE is uniquely applicable for determining the performance of coatings and inhibitors to control localised corrosion.

Research limitations/implications – Focusing mainly on recent research.

Practical implications – A useful source of information for researchers and graduate students working in the areas of organic coating and inhibitor research.

Originality/value – The first summary or review on this research topic.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper reports on the corrosion of Mg alloy AZ31 in simulated body fluid (SBF) using static immersion tests and electrochemical impedance spectroscopy. A preliminary study on the effect of flowing SBF on the corrosion behaviour of AZ31 has also been carried out. Low toxicity ionic liquids (ILs) trimethyl(butyl)phosphonium diphenyl phosphate P1444DPP and trihexyl(tetradecyl)-phosphonium bis-2,4,4trimethylpentyl-phosphinate [P66614][ i(C8) 2PO2] have been used to provide corrosion protection for AZ31 in SBF. Time dependent immersion tests indicate that under static conditions, AZ31 suffers severe localised corrosion in SBF, with pits developing predominantly beside the Al-Mn intermetallic phase in the α matrix. At longer immersion times, the corrosion product eventually precipitates and covers the entire specimen surface. When exposed to SBF under flowing conditions with a shear stress of 0·88 Pa, more uniform corrosion was observed. The optical profilometry results and electrochemical impedance spectroscopy analysis suggest that both P
1444DPP and [P66614][i(C8)2PO2] pretreatments can increase the corrosion resistance of AZ31 in SBF, in particular by decreasing the number of deeper pits found on the alloy surface. Cytotoxic test shows that the presence of the ILs P
1444DPP and [P66614][i(C8)2PO2] in cell culture media slightly inhibits the growth of human coronary artery endothelial cells in comparison with the good cell viability around the treated specimen. A pretreatment with IL is used in order to improve the corrosion resistance of this alloy in SBF. © 2012 Institute of Materials, Minerals and Mining.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Electrochemical methods can be used more effectively if innovative experiments are designed and employed. This is especially true if a corrosion system to be tested involves inhibitors that could change the mechanism and pattern of corrosion in complex ways. This paper discusses corrosion inhibitor test design using several practical cases as examples. Particular attention is on difficult issues such as the simulation of localized corrosion phenomena and the influence of corrosion mechanism on inhibitor test results. ©2012 by NACE International.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Since the introduction of inhibitors to the oil and gas industry in the 1940’s, corrosion inhibition has played a key role in carbon dioxide (CO2) corrosion control. Major inhibitor discoveries occurred from the late 1940's to the late 1960's, followed by the refinement of formulations and the development of improved application methods. Over the past two to three decades, although some new derivatives of existing inhibitors such as amide, amine and imidazoline have been reported, there have been few if any discoveries of new CO2 corrosion inhibitors. In recent years, the development of environmentally friendly inhibitors and the inhibition of localised corrosion have become driving forces behind new advances in corrosion inhibitor technology. Recently a rare earth metal organic compound, lanthanum 4-hydroxy cinnamate has been found to be an efficient corrosion inhibitor for mild steel in CO2 containing aqueous media. A resorcinarene acid has been found to provide effective localised corrosion inhibition by promoting a random distribution of insignificant anodic currents. The advent of advanced scanning probe techniques and an electrochemical integrated multi-electrode array have facilitated the discovery of corrosion inhibitors. This paper provides a brief overview of recent progress in this field.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The use of the aluminium alloy AA2024-T3 has long been associated with a strong vulnerability to localised corrosion. Dealloying and pitting corrosion can occur on and around intermetallic particles when exposed to aggressive environments such as sodium chloride electrolytes. Specific combinations of rare earths and organic compounds have demonstrated strong synergistic inhibition on the AA2024-T3 alloy. This work has focused on rare earths and organic compounds containing thiol functional groups. It is believed that the sulphur in the thiol group can form protective films over the surface of copper-rich intermetallic particles due to the affinity between copper and sulphur. Previous studies with the multiwell tests have identified that solutions containing sodium mercaptoacetate provided strong inhibition at pH 3 and 6. This work presents the initial findings from the polarisation tests and constant immersion corrosion experiments in the presence of sodium mercaptoacetate.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Localized corrosion can occur under disbonded coatings threatening the safe operation of industry infrastructures such as underground oil and gas pipelines. Currently the assessment of localised corrosion under coating defects is a major technical challenge. The application of corrosion probes to monitor corrosion under disbonded coating also remains a difficulty. This paper presents a new corrosion sensor concept capable of electrochemically measuring corrosion rates under disbonded coatings on cathodically protected structures such as energy pipelines. Examples of its capabilities are illustrated with experimental data obtained in low conductivity aqueous solutions.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Localised corrosion is typical on AA2024-T3 due to intermetallic particles embedded in the alloy. The effect of intermetallic compositions on corrosion are not yet fully understood. EPMA data on AA2024-T3 surfaces before and after a 16. min immersion, analyses the influence of intermetallic clustering on the severity attack at local sites. While sites with a high number of domains and a large S-phase surface area typically lead to severe attack, maximising these features did not always lead to severe corrosion attack. Cerium or praseodymium mercaptoacetate inhibited corrosion ring formation. The common trends observed from such attack sites was also discussed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

An approach to achieving the ambitious goal of cost effectively extending the safe operation life of energy pipeline to 100 years is the application of health monitoring and life prediction tools that are able to provide both long-term remnant pipeline life prediction and in-situ pipeline condition monitoring. A critical step is the enhancement of technological capabilities that are required for understanding and quantifying the effects of key factors influencing buried steel pipeline corrosion and environmentally assisted materials degradation, and the development of condition monitoring technologies that are able to provide in-situ monitoring and site-specific warning of pipeline damage. This paper provides an overview of our current research aimed at developing new sensors and electrochemical cells for monitoring, categorising and quantifying the level and nature of external pipeline and coating damages under the combined effects of various inter-related variables and processes such as localised corrosion, coating cracking and disbondment, cathodic shielding, transit loss of cathodic protection.