821 resultados para knee arthroplasty


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Restoring a correct implant kinematics and providing a good ligament balance and patellar tracking is mandatory to improve clinical and functional outcome after a Total Knee Replacement. Surgical navigation systems are a reliable and accurate tool to help the surgeon in achieving these goals. The aim of the present study was to use navigation system with an intra-operative surgical protocol to evaluate and determine an optimal implant kinematics during a Total Knee Replacement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The goal of this thesis was the study of the cement-bone interface in the tibial component of a cemented total knee prosthesis. One of the things you can see in specimens after in vivo service is that resorption of bone occurs in the interdigitated region between bone and cement. A stress shielding effect was investigated as a cause to explain bone resorption. Stress shielding occurs when bone is loaded less than physiological and therefore it starts remodeling according to the new loading conditions. µCT images were used to obtain 3D models of the bone and cement structure and a Finite Element Analysis was used to simulate different kind of loads. Resorption was also simulated by performing erosion operations in the interdigitated bone region. Finally, 4 models were simulated: bone (trabecular), bone with cement, and two models of bone with cement after progressive erosions of the bone. Compression, tension and shear test were simulated for each model in displacement-control until 2% of strain. The results show how the principal strain and Von Mises stress decrease after adding the cement on the structure and after the erosion operations. These results show that a stress shielding effect does occur and rises after resorption starts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors report on bilateral simultaneous knee arthroplasty in a 40-year-old male patient with haemophilia A, high inhibitor titre and an aneurysma spurium of the right popliteal artery. Both knees showed a fixed flexion deformity of 20 degrees. To build up haemostasis, treatment with activated prothrombin complex concentrate (APCC) and recombinant activated factor seven (rFVIIa) was initiated preoperatively. A tourniquet was used on both sides during the operation and factor VIII (FVIII) was administered to further correct coagulopathy. On the eleventh postoperative day the patient complained of increasing pain and pressure in the right knee. An ultrasound suggested aneurysm, which was confirmed by substraction angiography. Under the protection of rFVIIa the aneurysm could be coiled and further rehabilitation was uneventful. At one year post-op the patient presented a range of motion of 90/5/0 degrees for both knees and had returned to full time office work. This case indicates that haemophiliacs with high antibody titre and destruction of both knees can be operated on in one session in order to diminish the operative risk of two consecutive surgical procedures, thus allowing an effective rehabilitation programme. Because of the significant frequency of popliteal aneurysms, preoperative angiography is recommended.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a series of 16 consecutive total knee arthroplasty (TKA) revision procedures for deep infection, treated with a newly developed intraoperatively moulded PMMA cement-prostheses-like spacer (CPLS). The standard treatment consisted of a two-stage protocol with initial explantation of the infected components combined with radical debridement, followed by implantation of a temporary cement spacer and final reimplantation of a new TKA. A sterilizeable Teflon tapered aluminium mould was developed for production of a custom made CPLS during the intervention. Stable implantation of the CPLS was achieved with a second cementation, allowing for correct alignment and ligament balancing. The spacer remained 3.5 months on average until reimplantation of a TKA occurred. At time of reimplantation, patients had an average KSS score of 84.44 points with an average flexion capacity of 102°. There was no recurrent infection during the study period of minimum 2 years. With this new technique, a low friction articulation with good stability, high comfort and a better range of motion compared to handcrafted spacers was achieved. The use of this spacer is a time sparing, cheap and convenient option in 2-stage TKA revision.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Total knee arthroplasty (TKA) disturbs patellar blood flow, an unintended accompaniment to TKA that may be a cause of postoperative anterior knee pain. We examine whether disrupted patellar blood flow correlates with anterior knee pain following TKA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Computer navigation in total knee arthroplasty is somewhat controversial. We have previously shown that femoral component positioning is more accurate with computed navigation than with conventional implantation techniques, but the clinical impact of this is unknown. We now report the 5-year outcome of our previously reported 2-year outcome study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Joint hemorrhages are very common in patients with severe hemophilia. Inhibitors in patients with hemophilia are allo-antibodies that neutralize the activity of the clotting factor. After total knee replacement, rare intra-articular bleeding complications might occur that do not respond to clotting factor replacement. We report a 40-year-old male with severe hemophilia A and high responding inhibitors presenting with recurrent knee joint hemorrhage after bilateral knee prosthetic surgery despite adequate clotting factor treatment. There were two episodes of marked postoperative hemarthrosis requiring extensive use of substitution therapy. Eleven days postoperatively, there was further hemorrhage into the right knee. Digital subtraction angiography diagnosed a complicating pseudoaneurysm of the inferior lateral geniculate artery and embolization was successfully performed. Because clotting factor replacement therapy has proved to be excessively expensive and prolonged, especially in patients with inhibitors, we recommend the use of cost-effective early angiographic embolization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A total knee arthroplasty performed with navigation results in more accurate component positioning with fewer outliers. It is not known whether image-based or image-free-systems are preferable and if navigation for only one component leads to equal accuracy in leg alignment than navigation of both components. We evaluated the results of total knee arthroplasties performed with femoral navigation. We studied 90 knees in 88 patients who had conventional total knee arthroplasties, image-based total knee arthroplasties, or total knee arthroplasties with image-free navigation. We compared patients' perioperative times, component alignment accuracy, and short-term outcomes. The total surgical time was longer in the image-based total knee arthroplasty group (109 +/- 7 minutes) compared with the image-free (101 +/- 17 minutes) and conventional total knee arthroplasty groups (87 +/- 20 minutes). The mechanical axis of the leg was within 3 degrees of neutral alignment, although the conventional total knee arthroplasty group showed more (10.6 degrees ) variance than the navigated groups (5.8 degrees and 6.4 degrees , respectively). We found a positive correlation between femoral component malalignment and the total mechanical axis in the conventional group. Our results suggest image-based navigation is not necessary, and image-free femoral navigation may be sufficient for accurate component alignment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Skeletal tuberculosis is now uncommon in developed countries. In immunocompromised patients - particularly in the HIV-infected - who present with subacute or chronic joint pain refractory to conventional treatment, osteoarticular tuberculosis should still be included in the differential diagnosis. We report on a lethal case of disseminated tuberculosis in an HIV-infected subject. Dissemination may have resulted from the implantation of an articular prosthesis in a knee joint with unsuspected osteoarticular tuberculosis. The diagnosis was established months later when the patient presented with far-advanced tuberculous meningitis, miliary tuberculosis of the lungs, femoral osteomyelitis and extended cold abscesses along the femoral shaft. Failure to respond to a conventional four-drug regimen is explained by the resistance pattern of his multi-drug resistant strain of Mycobacterium tuberculosis, which was only reported after the patient's death. This case illustrates the diagnostic challenges of osteoarticular tuberculosis and the consequences of a diagnostic delay in an HIV-infected individual.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Clinical assessments after Total Knee Arthroplasty (TKA) show persisting pain after implantation in over 20% of patients. Impingement of soft tissue around the knee, due to imprecise geometry of the tibial implant, can be one reason for persisting ailment. Two hundred and thirty seven MRI scans were evaluated using an active contour detection algorithm (snake) to obtain a high-resolution mean anatomical shape of the tibial plateau. Differences between female and male, older and younger (40) and left and right averaged shapes were determined. The shapes obtained were asymmetric throughout. Absolute differences between the subgroups fell short of inter-individual variations represented by calculated one-sigma confidence intervals. Our results indicate that a differentiation in TKA tibial plateau design by gender, age, or side is of minor relevance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The main goals of the standard treatment for advanced symptomatic knee osteoarthritis, total knee arthroplasty (TKA), are pain reduction and restoration of knee motion.The aim of this study was to analyse the outcome of the patient-based Knee Injury and Osteoarthritis Outcome Score (KOOS), and the surgeon-based Knee Society Score (KSS) and its Knee Score (KS) and Knee Functional Score (KFS) components after (TKA) using the Journey knee prosthesis, and to assess the correlation of these scores with range of motion (ROM). METHODS In a prospective case series study between August 1st 2008 and May 31st 2011, 99 patients, all operated by a single surgeon, received Journey bicruciate stabilized total knee prostheses. The female/male ratio was 53/34, the mean patient age at surgery was 68 years (range 41-83 years), and the left/right knee ratio was 55/44. The KOOS, range of motion, and KS and KFS were obtained preoperatively and at 1-year follow-up. The pre- and postoperative levels of the outcome measures were compared using the Wilcoxon signed-rank test. Correlation between ROM and patient outcomes was analysed with the Spearman coefficient. RESULTS All KOOS subscores improved significantly. Ninety percent of patients improved by at least the minimum clinically relevant difference of 10 points in stiffness and other symptoms, 94.5% in pain, 94.5% in activities of daily living, 84.9% in sports and recreation, and 90% in knee-related quality of life. The mean passive and active ROM improved from 122.4° (range 90-145°) and 120.4° (range 80-145°) preoperatively to 129.4° (range 90-145°) and 127.1° (range 100-145°) postoperatively. The highest correlation coefficients for ROM and KOOS were observed for the activity and pain subscores. Very low or no correlation was seen for the sport subscore.There was a significant and clinically relevant improvement of KSS (preop/postop 112.2/174.5 points), and its KS (preop/postop 45.6/86.8 points) and KFS (preop/postop 66.6/87.8 points) components. CONCLUSIONS The Journey bicruciate stabilized knee prosthesis showed good 1-year postoperative results in terms of both functional and patient-based outcome. However, higher knee ROM correlates only moderately with patient-based outcome, implying that functionality afforded by the Journey bicruciate TKA is not equivalent to patient satisfaction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Knee osteoarthritis (OA) is the most prevalent form of arthritis in the US, affecting approximately 37% of adults. Approximately 300,000 total knee arthroplasty (TKA) procedures take place in the United States each year. Total knee arthroplasty is an elective procedure available to patients as an irreversible treatment after failure of previous medical treatments. Some patients sacrifice quality of life and endure many years of pain before making the decision to undergo total knee replacement. In making their decision, it is therefore imperative for patients to understand the procedure, risks and surgical outcomes to create realistic expectations and increase outcome satisfaction. ^ From 2004-2007, 236 OA patients who underwent TKA participated in the PEAKS (Patient Expectations About Knee Surgery) study, an observational longitudinal cohort study, completed baseline and 6 month follow-up questionnaires after the surgery. We performed a secondary data analysis of the PEAKS study to: (1) determine the specific presurgical patient characteristics associated with patients’ presurgical expectations of time to functional recovery; and (2) determine the association between presurgical expectations of time to functional recovery and postsurgical patient capabilities (6 months after TKA). We utilized the WOMAC to measure knee pain and function, the SF-36 to measure health-related quality of life, and the DASS and MOS-SSS to measure psychosocial quality of life variables. Expectation and capability measures were generated from panel of experts. A list of 10 activities was used for this analysis to measure functional expectations and postoperative functional capabilities. ^ The final cohort consisted of 236 individuals, was predominately White with 154 women and 82 men. The mean age was 65 years. Patients were optimistic about their time to functional recovery. Expectation time of being able to perform the list activities per patient had a median of less than 3 months. Patients who expected to be able to perform the functional activities by 3 months had better knee function, less pain and better overall health-related quality of life. Despite expectation differences, all patients showed significant improvement 6 months after surgery. Participant expectation of time to functional recovery was not an independent predictor of capability to perform functional activities at 6 months. Better presurgical patient characteristics were, however, associated with a higher likelihood of being able to perform all activities at 6 months. ^ This study gave us initial insight on the relationship between presurgical patient characteristics and their expectations of functional recovery after total knee replacement. Future studies clarifying the relationship between patient presurgical characteristics and postsurgical functional capabilities are needed.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Anticoagulation used for thromboembolic prophylaxis following total knee arthroplasty (TKA) could interfere with movement. This study compares the effect of 2 anticoagulants, enoxaparin and aspirin, on restoration of range of motion (ROM) after TKA. Two groups of 75 consecutive patients, matched for age, arthritic severity, and preoperative ROM, underwent TKA. Flexion and extension milestone measures were recorded daily. Results show a highly statistically significant difference (P

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Medial UKA performed in England and Wales represents 7 to 11% of all knee arthroplasty procedures, and is most commonly performed using mobile-bearing designs. Fixed bearing eliminates the risk of bearing dislocation, however some studies have shown higher revision rates for all-polyethylene tibial components compared to those that utilize metal-backed implants. The aim of the study is to analyse survivorship and maximum 8-year clinical outcome of medial fixed bearing, Uniglide unicompartmental knee arthroplasty performed using an all-polyethylene tibial component with a minimal invasive approach. Methods: Between 2002 and 2009, 270 medial fixed UKAs were performed in our unit. Patients were reviewed pre-operatively, 5 and 8 years post-operatively. Clinical and radiographic reviews were carried out. Patients’ outcome scores (Oxford, WOMAC and American Knee Score) were documented in our database and analysed. Results: Survival and clinical outcome data of 236 knees with a mean 7.3 years follow-up are reported. Every patient with less than 4.93 years follow-up underwent a revision. The patients’ average age at the time of surgery was 69.5 years. The American Knee Society Pain and Function scores, the Oxford Knee Score and the WOMAC score all improved significantly. The 5 years survival rate was 94.1% with implant revision surgery as an end point. The estimated 10 years survival rate is 91.3%. 14 patients were revised before the 5 year follow-up. Conclusion: Fixed bearing Uniglide UKA with an all-polyethylene tibial component is a valuable tool in the management of a medial compartment osteoarthritis, affording good short term survivorship.