999 resultados para joint angles


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis is a study on controlling methods for six-legged robots. The study is based on mathematical modeling and simulation. A new joint controller is proposed and tested in simulation that uses joint angles and leg reaction force as inputs to generate a torque, and a method to optimise this controller is formulated and validated. Simulation shows that hexapod can walk on flat ground based on PID controllers with just four target configurations and a set of leg coordination rules, which provided the basis for the design of the new controller.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction Markerless motion capture systems are relatively new devices that can significantly speed up capturing full body motion. A precision of the assessment of the finger’s position with this type of equipment was evaluated at 17.30 ± 9.56 mm when compare to an active marker system [1]. The Microsoft Kinect was proposed to standardized and enhanced clinical evaluation of patients with hemiplegic cerebral palsy [2]. Markerless motion capture systems have the potential to be used in a clinical setting for movement analysis, as well as for large cohort research. However, the precision of such system needs to be characterized. Global objectives • To assess the precision within the recording field of the markerless motion capture system Openstage 2 (Organic Motion, NY). • To compare the markerless motion capture system with an optoelectric motion capture system with active markers. Specific objectives • To assess the noise of a static body at 13 different location within the recording field of the markerless motion capture system. • To assess the smallest oscillation detected by the markerless motion capture system. • To assess the difference between both systems regarding the body joint angle measurement. Methods Equipment • OpenStage® 2 (Organic Motion, NY) o Markerless motion capture system o 16 video cameras (acquisition rate : 60Hz) o Recording zone : 4m * 5m * 2.4m (depth * width * height) o Provide position and angle of 23 different body segments • VisualeyezTM VZ4000 (PhoeniX Technologies Incorporated, BC) o Optoelectric motion capture system with active markers o 4 trackers system (total of 12 cameras) o Accuracy : 0.5~0.7mm Protocol & Analysis • Static noise: o Motion recording of an humanoid mannequin was done in 13 different locations o RMSE was calculated for each segment in each location • Smallest oscillation detected: o Small oscillations were induced to the humanoid mannequin and motion was recorded until it stopped. o Correlation between the displacement of the head recorded by both systems was measured. A corresponding magnitude was also measured. • Body joints angle: o Body motion was recorded simultaneously with both systems (left side only). o 6 participants (3 females; 32.7 ± 9.4 years old) • Tasks: Walk, Squat, Shoulder flexion & abduction, Elbow flexion, Wrist extension, Pronation / supination (not in results), Head flexion & rotation (not in results), Leg rotation (not in results), Trunk rotation (not in results) o Several body joint angles were measured with both systems. o RMSE was calculated between signals of both systems. Results Conclusion Results show that the Organic Motion markerless system has the potential to be used for assessment of clinical motor symptoms or motor performances However, the following points should be considered: • Precision of the Openstage system varied within the recording field. • Precision is not constant between limb segments. • The error seems to be higher close to the range of motion extremities.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

视觉伺服可以应用于机器人初始定位自动导引、自动避障、轨线跟踪和运动目标跟踪等控制系统中。传统的视觉伺服系统在运行时包括工作空间定位和动力学逆运算两个过程,需要实时计算视觉雅可比矩阵和机器人逆雅可比矩阵,计算量大,系统结构复杂。本文分析了基于图像的机器人视觉伺服的基本原理,使用BP神经网络来确定达到指定位姿所需要的关节角度,将视觉信息直接融入伺服过程,在保证伺服精度的情况下大大简化了控制算法。文中针对Puma560工业机器人的模型进行了仿真实验,结果验证了该方法的有效性。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis examines a tactile sensor and a thermal sensor for use with the Utah-MIT dexterous four fingered hand. Sensory feedback is critical or full utilization of its advanced manipulatory capabilities. The hand itself provides tendon tensions and joint angles information. However, planned control algorithms require more information than these sources can provide. The tactile sensor utilizes capacitive transduction with a novel design based entirely on silicone elastomers. It provides an 8 x 8 array of force cells with 1.9 mm center-to-center spacing. A pressure resolution of 8 significant bits is available over a 0 to 200 grams per square mm range. The thermal sensor measures a material's heat conductivity by radiating heat into an object and measuring the resulting temperature variations. This sensor has a 4 x 4 array of temperature cells with 3.5 mm center-to-center spacing. Experiments show that the thermal sensor can discriminate among material by detecting differences in their thermal conduction properties. Both sensors meet the stringent mounting requirements posed by the Utah-MIT hand. Combining them together to form a sensor with both tactile and thermal capabilities will ultimately be possible. The computational requirements for controlling a sensor equipped dexterous hand are severe. Conventional single processor computers do not provide adequate performance. To overcome these difficulties, a computational architecture based on interconnecting high performance microcomputers and a set of software primitives tailored for sensor driven control has been proposed. The system has been implemented and tested on the Utah-MIT hand. The hand, equipped with tactile and thermal sensors and controlled by its computational architecture, is one of the most advanced robotic manipulatory devices available worldwide. Other ongoing projects will exploit these tools and allow the hand to perform tasks that exceed the capabilities of current generation robots.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A system for recovering 3D hand pose from monocular color sequences is proposed. The system employs a non-linear supervised learning framework, the specialized mappings architecture (SMA), to map image features to likely 3D hand poses. The SMA's fundamental components are a set of specialized forward mapping functions, and a single feedback matching function. The forward functions are estimated directly from training data, which in our case are examples of hand joint configurations and their corresponding visual features. The joint angle data in the training set is obtained via a CyberGlove, a glove with 22 sensors that monitor the angular motions of the palm and fingers. In training, the visual features are generated using a computer graphics module that renders the hand from arbitrary viewpoints given the 22 joint angles. We test our system both on synthetic sequences and on sequences taken with a color camera. The system automatically detects and tracks both hands of the user, calculates the appropriate features, and estimates the 3D hand joint angles from those features. Results are encouraging given the complexity of the task.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to examine the effects of cadence and power output on physiological and biomechanical responses to incremental arm-crank ergometry (ACE). Ten male subjects (mean +/- SD age, 30.4 +/-5.4 y; height, 1.78 +/-0.07 m; mass, 86.1 +/-14.2 kg) undertook 3 incremental ACE protocols to determine peak oxygen uptake (VO2 peak; mean of 3 tests: 3.07 +/- 0.17 L.min-1) at randomly assigned cadences of 50, 70, or 90 r.min-1. Heart rate and expired air were continually monitored. Central (RPE-C) and local (RPE-L) ratings of perceived exertion were recorded at volitional exhaustion. Joint angles and trunk rotation were analysed during each exercise stage. During submaximal power outputs of 50, 70, and 90 W, oxygen consumption (VO2) was lowest for 50 r.min-1 and highest for 90 r.min-1 (p < 0.01). VO2 peak was lowest during 50 r.min-1 (2.79 +/-0.45 L.min-1; p < 0.05) when compared with both 70 r.min-1 and 90 r.min-1 (3.16 +/-0.58, 3.24 +/-0.49 L.min-1, respectively; p > 0.05). The difference between RPE-L and RPE-C at volitional exhaustion was greatest during 50 r.min-1 (2.9 +/- 1.6) when compared with 90 r.min-1 (0.9 +/- 1.9, p < 0.05). At VO2 peak, shoulder range of motion (ROM) and trunk rotation were greater for 50 and 70 r.min-1 when compared with 90 r.min-1 (p < 0.05). During submaximal power outputs, shoulder angle and trunk rotation were greatest at 50 r.min-1 when compared with 90 r.min-1 (p < 0.05). VO2 was inversely related to both trunk rotation and shoulder ROM during submaximal power outputs. The results of this study suggest that the greater forces required at lower cadences to produce a given power output resulted in greater joint angles and range of shoulder and trunk movement. Greater isometric contractions for torso stabilization and increased cost of breathing possibly from respiratory-locomotor coupling may have contributed increased oxygen consumption at higher cadences.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente estudo tem como objetivo comparar experimentalmente duas crianças praticantes de Hóquei em Patins, uma normal e uma com a patologia dos joelhos valgos, avaliando qualitativamente as diferenças posturais, estáticas e dinâmicas, decorrentes da utilização dos patins específicos desta modalidade, através do sistema de análise da Força de Reação do Solo (FRS), de Eletromiografia (EMG), de captura de movimento, e de modelação e simulação. Para atingir o objetivo definiu-se um protocolo de ensaios com as seguintes tarefas: repouso com e sem patins, marcha, corrida, deslizar com os dois pés apoiados e deslizar com o pé esquerdo levantado. No repouso avaliou-se a variação do ponto de aplicação da FRS da criança normal e patológica, com e sem patins. Ainda na tarefa de repouso avaliou-se também as componentes médio-lateral, antero-posterior individualmente e a componente vertical da FRS, juntamente com a atividade muscular dos músculos Gastrocnémio Medial (GM), Recto Femoral (RF), Vasto Medial (VM), Vasto Lateral (VL), Bicípete Femoral (BF), Semitendinoso (ST), Tensor da Fascia Lata (TFL), Gastrocnémio Lateral (GL), de forma a comparar os valores de intensidade de FRS e da atividade muscular dos diferentes instantes de tempo desta tarefa. Para as restantes tarefas apenas se avaliou individualmente as componentes médio-lateral e antero-posterior da FRS e a componente vertical da FRS juntamente com a atividade muscular dos referidos músculos, salientando as diferenças evidentes entre as curvas da criança normal e as curvas da criança patológica durante os diferentes instantes do movimento. Todas as tarefas referidas, exceto a tarefa de repouso com patins, foram ainda simuladas recorrendo a modelos músculo-esqueléticos. A partir destas simulações do movimento obtiveram-se os ângulos articulares e efetuou-se a respetiva análise. No final dos resultados obtidos apresentou-se uma tabela de resumo com o cálculo dos coeficientes de variação de cada grandeza, exceto nos gráficos da posição no espaço da FRS, onde se constatou que existe uma grande variabilidade inter-individuo em cada tarefa. A análise dos resultados de cada tarefa permite concluir que a utilização de patins pode trazer uma maior ativação muscular para a criança patológica, embora se verifique instabilidade articular. Apesar dessa instabilidade pode-se inferir que, uma maior ativação muscular decorrente da utilização de patins, tal como acontece na prática do hóquei em patins, pode trazer uma melhoria, a longo prazo, na estabilidade da articulação do joelho e na sustentação corporal, proporcionada pelo fortalecimento muscular.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Coordination is a strategy chosen by the central nervous system to control the movements and maintain stability during gait. Coordinated multi-joint movements require a complex interaction between nervous outputs, biomechanical constraints, and pro-prioception. Quantitatively understanding and modeling gait coordination still remain a challenge. Surgeons lack a way to model and appreciate the coordination of patients before and after surgery of the lower limbs. Patients alter their gait patterns and their kinematic synergies when they walk faster or slower than normal speed to maintain their stability and minimize the energy cost of locomotion. The goal of this study was to provide a dynamical system approach to quantitatively describe human gait coordination and apply it to patients before and after total knee arthroplasty. Methods: A new method of quantitative analysis of interjoint coordination during gait was designed, providing a general model to capture the whole dynamics and showing the kinematic synergies at various walking speeds. The proposed model imposed a relationship among lower limb joint angles (hips and knees) to parameterize the dynamics of locomotion of each individual. An integration of different analysis tools such as Harmonic analysis, Principal Component Analysis, and Artificial Neural Network helped overcome high-dimensionality, temporal dependence, and non-linear relationships of the gait patterns. Ten patients were studied using an ambulatory gait device (Physilog®). Each participant was asked to perform two walking trials of 30m long at 3 different speeds and to complete an EQ-5D questionnaire, a WOMAC and Knee Society Score. Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. The outcomes of the eight patients undergoing total knee arthroplasty, recorded pre-operatively and post-operatively at 6 weeks, 3 months, 6 months and 1 year were compared to 2 age-matched healthy subjects. Results: The new method provided coordination scores at various walking speeds, ranged between 0 and 10. It determined the overall coordination of the lower limbs as well as the contribution of each joint to the total coordination. The difference between the pre-operative and post-operative coordination values were correlated with the improvements of the subjective outcome scores. Although the study group was small, the results showed a new way to objectively quantify gait coordination of patients undergoing total knee arthroplasty, using only portable body-fixed sensors. Conclusion: A new method for objective gait coordination analysis has been developed with very encouraging results regarding the objective outcome of lower limb surgery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: Overuse injuries in violinists are a problem that has been primarily analyzed through the use of questionnaires. Simultaneous 3D motion analysis and EMG to measure muscle activity has been suggested as a quantitative technique to explore this problem by identifying movement patterns and muscular demands which may predispose violinists to overuse injuries. This multi-disciplinary analysis technique has, so far, had limited use in the music world. The purpose of this study was to use it to characterize the demands of a violin bowing task. Subjects: Twelve injury-free violinists volunteered for the study. The subjects were assigned to a novice or expert group based on playing experience, as determined by questionnaire. Design and Settings: Muscle activity and movement patterns were assessed while violinists played five bowing cycles (one bowing cycle = one down-bow + one up-bow) on each string (G, D, A, E), at a pulse of 4 beats per bow and 100 beats per minute. Measurements: An upper extremity model created using coordinate data from markers placed on the right acromion process, lateral epicondyle of the humerus and ulnar styloid was used to determine minimum and maximum joint angles, ranges of motion (ROM) and angular velocities at the shoulder and elbow of the bowing arm. Muscle activity in right anterior deltoid, biceps brachii and triceps brachii was assessed during maximal voluntary contractions (MVC) and during the playing task. Data were analysed for significant differences across the strings and between experience groups. Results: Elbow flexion/extension ROM was similar across strings for both groups. Shoulder flexion/extension ROM increaslarger for the experts. Angular velocity changes mirrored changes in ROM. Deltoid was the most active of the muscles assessed (20% MVC) and displayed a pattern of constant activation to maintain shoulder abduction. Biceps and triceps were less active (4 - 12% MVC) and showed a more periodic 'on and off pattern. Novices' muscle activity was higher in all cases. Experts' muscle activity showed a consistent pattern across strings, whereas the novices were more irregular. The agonist-antagonist roles of biceps and triceps during the bowing motion were clearly defined in the expert group, but not as apparent in the novice group. Conclusions: Bowing movement appears to be controlled by the shoulder rather than the elbow as shoulder ROM changed across strings while elbow ROM remained the same. Shoulder injuries are probably due to repetition as the muscle activity required for the movement is small. Experts require a smaller amount of muscle activity to perform the movement, possibly due to more efficient muscle activation patterns as a result of practice. This quantitative multidisciplinary approach to analysing violinists' movements can contribute to fuller understanding of both playing demands and injury mechanisms .

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Imitation is an important form of social behavior, and research has aimed to discover and explain the neural and kinematic aspects of imitation. However, much of this research has featured single participants imitating in response to pre-recorded video stimuli. This is in spite of findings that show reduced neural activation to video vs. real life movement stimuli, particularly in the motor cortex. We investigated the degree to which video stimuli may affect the imitation process using a novel motion tracking paradigm with high spatial and temporal resolution. We recorded 14 positions on the hands, arms, and heads of two individuals in an imitation experiment. One individual freely moved within given parameters (moving balls across a series of pegs) and a second participant imitated. This task was performed with either simple (one ball) or complex (three balls) movement difficulty, and either face-to-face or via a live video projection. After an exploratory analysis, three dependent variables were chosen for examination: 3D grip position, joint angles in the arm, and grip aperture. A cross-correlation and multivariate analysis revealed that object-directed imitation task accuracy (as represented by grip position) was reduced in video compared to face-to-face feedback, and in complex compared to simple difficulty. This was most prevalent in the left-right and forward-back motions, relevant to the imitator sitting face-to-face with the actor or with a live projected video of the same actor. The results suggest that for tasks which require object-directed imitation, video stimuli may not be an ecologically valid way to present task materials. However, no similar effects were found in the joint angle and grip aperture variables, suggesting that there are limits to the influence of video stimuli on imitation. The implications of these results are discussed with regards to previous findings, and with suggestions for future experimentation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, an active stereo vision-based learning approach is proposed for a robot to track, fixate and grasp an object in unknown environments. First, the functional mapping relationships between the joint angles of the active stereo vision system and the spatial representations of the object are derived and expressed in a three-dimensional workspace frame. Next, the self-adaptive resonance theory-based neural networks and the feedforward neural networks are used to learn the mapping relationships in a self-organized way. Then, the approach is verified by simulation using the models of an active stereo vision system which is installed in the end-effector of a robot. Finally, the simulation results confirm the effectiveness of the present approach.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Adding to a previous work of the authors for task completion for partially failed manipulator, other aspects of the effort are discussed. The paper aims to investigate on the strategies of maximum effort for maintaining the availability of partially failed manipulators. The failures are assumed as the joint lock failures of the manipulators. The main objective is to facilitate the existing manipulators to continue their tasks even if a non catastrophic fault occurs into their joints. The tasks includes motion tasks and force tasks. For each group of tasks a constrained optimality problem is introduced. Then in a case study a required force profile on a desired trajectory using a 3DOF planar manipulator is indicated. Through this study the joint angles and joint torques for a healthy manipulator and a faulty manipulator are shown. It is illustrated that a failure in the second joint is tolerated on the trajectory of end-effector.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Running is the most important discipline for Olympic triathlon success. However, cycling impairs running muscle recruitment and performance in some highly trained triathletes; though it is not known if this occurs in elite international triathletes. The purpose of this study was to investigate the effect of cycling in two different protocols on running economy and neuromuscular control in elite international triathletes. Muscle recruitment and sagittal plane joint angles of the left lower extremity and running economy were compared between control (no preceding cycle) and transition (preceded by cycling) runs for two different cycle protocols (20-minute low-intensity and 50-minute high-intensity cycles) in seven elite international triathletes. Muscle recruitment and joint angles were not different between control and transition runs for either cycle protocols. Running economy was also not different between control and transition runs for the ow-intensity (62.4 ^ 4.5 vs. 62.1 ^ 4.0 ml/min/kg, p . 0.05) and high-intensity (63.4 ^ 3.5 vs. 63.3 ^ 4.3 ml/min/kg, p . 0.05) cycle protocols. The results of this study demonstrate that both low- and high-intensity cycles do not adversely influence neuromuscular control and running economy in elite international triathletes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Bio-kinematic characterisations of human exercises constitute dealing with parameters such as velocity, acceleration, joint angles, etc. A majority of these are measured directly from various sensors ranging from RGB cameras to inertial sensors. However, due to certain limitations associated with these sensors, such as inherent noise, filters are required to be implemented to subjugate the effect from the noise. When the two-component (trajectory shape and dynamics) bio-kinematic encoding model is being established to represent an exercise, reducing the effect from noise embedded in raw data will be important since the underlying model can be quite sensitive to noise. In this paper, we examine and compare some commonly used filters, namely least-square Gaussian filter, Savitzky-Golay filter and optimal Kalman filter, with four groups of real data collected from Microsoft Kinectc , and assert that Savitzky- Golay filter is the best one when establishing an underlying model for human exercise representation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An accurate and standardised tool to measure the active range of motion (ROM) of the hand is essential to any progressive assessment scenario in hand therapy practice. Goniometers are widely used in clinical settings for measuring the ROM of the hand. However, such measurements have limitations with regard to inter-rater and intra-rater reliability and involve direct physical contact with the hand, possibly increasing the risk of transmitting infections. The system proposed in this paper is the first non-contact measurement system utilising Intel Perceptual Technology and a Senz3D Camera for measuring phalangeal joint angles. To enhance the accuracy of the system, we developed a new approach to achieve the total active movement without measuring three joint angles individually. An equation between the actual spacial position and measurement value of the proximal inter-phalangeal joint was established through the measurement values of the total active movement, so that its actual position can be inferred. Verified by computer simulations, experimental results demonstrated a significant improvement in the calculation of the total active movement and successfully recovered the actual position of the proximal inter-phalangeal joint angles. A trial that was conducted to examine the clinical applicability of the system involving 40 healthy subjects confirmed the practicability and consistency in the proposed system. The time efficiency conveyed a stronger argument for this system to replace the current practice of using goniometers.