920 resultados para incident angle
Resumo:
In order to power our planet for the next century, clean energy technologies need to be developed and deployed. Photovoltaic solar cells, which convert sunlight into electricity, are a clear option; however, they currently supply 0.1% of the US electricity due to the relatively high cost per Watt of generation. Thus, our goal is to create more power from a photovoltaic device, while simultaneously reducing its price. To accomplish this goal, we are creating new high efficiency anti-reflection coatings that allow more of the incident sunlight to be converted to electricity, using simple and inexpensive coating techniques that enable reduced manufacturing costs. Traditional anti-reflection coatings (consisting of thin layers of non-absorbing materials) rely on the destructive interference of the reflected light, causing more light to enter the device and subsequently get absorbed. While these coatings are used on nearly all commercial cells, they are wavelength dependent and are deposited using expensive processes that require elevated temperatures, which increase production cost and can be detrimental to some temperature sensitive solar cell materials. We are developing two new classes of anti-reflection coatings (ARCs) based on textured dielectric materials: (i) a transparent, flexible paper technology that relies on optical scattering and reduced refractive index contrast between the air and semiconductor and (ii) silicon dioxide (SiO2) nanosphere arrays that rely on collective optical resonances. Both techniques improve solar cell absorption and ultimately yield high efficiency, low cost devices. For the transparent paper-based ARCs, we have recently shown that they improve solar cell efficiencies for all angles of incident illumination reducing the need for costly tracking of the sun’s position. For a GaAs solar cell, we achieved a 24% improvement in the power conversion efficiency using this simple coating. Because the transparent paper is made from an earth abundant material (wood pulp) using an easy, inexpensive and scalable process, this type of ARC is an excellent candidate for future solar technologies. The coatings based on arrays of dielectric nanospheres also show excellent potential for inexpensive, high efficiency solar cells. The fabrication process is based on a Meyer rod rolling technique, which can be performed at room-temperature and applied to mass production, yielding a scalable and inexpensive manufacturing process. The deposited monolayer of SiO2 nanospheres, having a diameter of 500 nm on a bare Si wafer, leads to a significant increase in light absorption and a higher expected current density based on initial simulations, on the order of 15-20%. With application on a Si solar cell containing a traditional anti-reflection coating (Si3N4 thin-film), an additional increase in the spectral current density is observed, 5% beyond what a typical commercial device would achieve. Due to the coupling between the spheres originated from Whispering Gallery Modes (WGMs) inside each nanosphere, the incident light is strongly coupled into the high-index absorbing material, leading to increased light absorption. Furthermore, the SiO2 nanospheres scatter and diffract light in such a way that both the optical and electrical properties of the device have little dependence on incident angle, eliminating the need for solar tracking. Because the layer can be made with an easy, inexpensive, and scalable process, this anti-reflection coating is also an excellent candidate for replacing conventional technologies relying on complicated and expensive processes.
Resumo:
Dissertação (mestrado)—Universidade de Brasília, Faculdade UnB Gama, Programa de Pós-graduação em Integridade de Materiais da Engenharia, 2015.
Resumo:
Evaluation has been made on the monthly and annual average diurnal evolution of the hourly diffuse radiation as well as its radiometric fractions on surfaces inclined at 12.85, 22.85 and 32.85° to face North, in climate conditions of Botucatu, São Paulo, Brazil (22.85° S and 48.43° W). Measurements were made between 04/1998 to 08/2001 for 22.85°; 09/2001 to 02/2003 for 12.85° and 01/2004 to 12/2007 for 32.85°, with concomitant measures in the horizontal. For all surfaces the diffuse radiation was obtained from different method. Assessment has been performed as well on the radiometric fractions obtained from the ratio of diffuse radiation and global radiation (KDH and KDβ) and between radiation and diffuse radiation at the top of the atmosphere (KʹDH and KʹDβ) for the horizontal and tilted surfaces in hourly partition. The diffuse radiation levels were dependent on variations in precipitation and cloudiness. There was an increase in the differences between the diffuse radiation and the radiometric fractions with the increment of the angle, and in horizontally, which affected higher levels of diffuse radiation in spring and summer. The values of KDH and KDβ present in an inverse behavior were compared to diffuse radiation and theydecreased in the southern passage due to the increase of the direct component in the total of incident radiation.
Resumo:
[EN]When analysing the seismic response of pile groups, a vertically-incident wavefiel is usually employed even though it doesnot necessarily correspond to the worst case scenario. This work aims to study the influence of both type of seismic body wave and its angle of incidence on the dynamic response of pile foundations.
Resumo:
The aim of this thesis is the subjective and objective evaluation of angledependent absorption coefficients. As the assumption of a constant absorption coefficient over the angle of incidence is not always held, a new model acknowledging an angle-dependent reflection must be considered, to get a more accurate prediction in the sound field. The study provides information about the behavior of different materials in several rooms, depending on the reflection modeling of incident sound waves. An objective evaluation was run for an implementation of angle-dependent reflection factors in the image source and ray tracing simulation models. Results obtained were analysed after comparison to diffuse-field averaged data. However, changes in acoustic characteristics of a room do not always mean a variation in the listener’s perception. Thus, additional subjective evaluation allowed a comparison between the different results obtained with the computer simulation and the response from the individuals who participated in the listening test. The listening test was designed following a three-alternative forced-choice (3AFC) paradigm. In each interaction asked to the subjects a sequence of either three pink noise bursts or three natural signals was alternated. These results were supposed to show the influence and perception of the two different ways to implement surface reflection –either with diffuse or angle-dependent absorption properties. Results show slightly audible effects when material properties were exaggerated. El objetivo de este trabajo es la evaluación objetiva y subjetiva del coeficiente de absorción en función del ángulo de incidencia de la onda de sonido. La suposición de un coeficiente de absorción constante con respecto al ángulo de incidencia no siempre se sostiene. Por ello, un nuevo modelo considerando la reflexión dependiente del ángulo se debe tener en cuenta para obtener predicciones más certeras en el campo del sonido. El estudio proporciona información sobre el comportamiento de diferentes materiales en distintos recintos, dependientes del modelo de reflexión de las ondas de sonido incidentes. Debido a las dificultades a la hora de realizar las medidas y, por lo tanto, a la falta de datos, los coeficientes de absorción dependientes del ángulo a menudo no se tienen en cuenta a la hora de realizar las simulaciones. Hoy en día, aún no hay una tendencia de aplicar el coeficiente de absorción dependiente del ángulo para mejorar los modelos de reflexión. Por otra parte, para una medición satisfactoria de la absorción dependiente del ángulo, sólo hay unos pocos métodos. Las técnicas de medición actuales llevan mucho tiempo y hay algunos materiales, condiciones y ángulos que no pueden ser reproducidos y, por lo tanto, no es posible su medición. Sin embargo, en el presente estudio, los ángulos de incidencia de las ondas de sonido son conocidos y almacenados en una de base de datos para cada uno de los materiales, de modo que los coeficientes de absorción para el ángulo dado pueden ser devueltos siempre que sean requeridos por el usuario. Para realizar el estudio se llevó a cabo una evaluación objetiva, por medio de la implementación del factor de reflexión dependiente del ángulo en los modelos de fuentes imagen y trazado de rayos. Los resultados fueron analizados después de ser comparados con el promedio de los datos obtenidos en medidas en el campo difuso. La simulación se hizo una vez se configuraron un número de materiales creados por el autor, a partir de los datos existentes en la literatura y los catálogos de fabricantes. Los modelos de Komatsu y Mechel sirvieron como referencia para los materiales porosos, configurando la resistividad al aire o el grosor, y para los paneles perforados, introduciendo el radio de los orificios y la distancia entre centros, respectivamente. Estos materiales se situaban en la pared opuesta a la que se consideraba que debía alojar a la fuente sonora. El resto de superficies se modelaban con el mismo material, variando su coeficiente de absorción y/o de dispersión. Al mismo tiempo, una serie de recintos fueron modelados para poder reproducir distintos escenarios de los que obtener los resultados. Sin embargo, los cambios en las características acústicas de un recinto no significan variaciones en la percepción por parte del oyente. Por ello, una evaluación subjetiva adicional permitió una comparación entre los diferentes resultados obtenidos mediante la simulación informática y la respuesta de los individuos que participaron en la prueba de escucha. Ésta fue diseñada bajo las pautas del modelo de test three-alternative forced-choice (3AFC), con treinta y dos preguntas diferentes. En cada iteración los sujetos fueron preguntados por una secuencia alterna entre tres señales, siendo dos de ellas iguales. Éstas podían ser tanto ráfagas de ruido rosa como señales naturales, en este test se utilizó un fragmento de una obra clásica interpretada por un piano. Antes de contestar al cuestionario, los bloques de preguntas eran ordenados al azar. Para cada ensayo, la mezcla era diferente, así los sujetos no repetían la misma prueba, evitando un sesgo por efectos de aprendizaje. Los bloques se barajaban recordando siempre el orden inicial, para después almacenar los resultados reordenados. La prueba de escucha fue realizada por veintitrés personas, toda ellas con conocimientos dentro del campo de la acústica. Antes de llevar a cabo la prueba de escucha en un entorno adecuado, una hoja con las instrucciones fue facilitada a cada persona. Los resultados muestran la influencia y percepción de las dos maneras distintas de implementar las reflexiones de una superficie –ya sea con respecto a la propiedad de difusión o de absorción dependiente del ángulo de los materiales. Los resultados objetivos, después de ejecutar las simulaciones, muestran los datos medios obtenidos para comprender el comportamiento de distintos materiales de acuerdo con el modelo de reflexión utilizado en el caso de estudio. En las tablas proporcionadas en la memoria se muestran los valores del tiempo de reverberación, la claridad y el tiempo de caída temprana. Los datos de las características del recinto obtenidos en este análisis tienen una fuerte dependencia respecto al coeficiente de absorción de los diferentes materiales que recubren las superficies del cuarto. En los resultados subjetivos, la media de percepción, a la hora de distinguir las distintas señales, por parte de los sujetos, se situó significativamente por debajo del umbral marcado por el punto de inflexión de la función psicométrica. Sin embargo, es posible concluir que la mayoría de los individuos tienden a ser capaces de detectar alguna diferencia entre los estímulos presentados en el 3AFC test. En conclusión, la hipótesis de que los valores del coeficiente de absorción dependiente del ángulo difieren es contrastada. Pero la respuesta subjetiva de los individuos muestra que únicamente hay ligeras variaciones en la percepción si el coeficiente varía en intervalos pequeños entre los valores manejados en la simulación. Además, si los parámetros de los materiales acústicos no son exagerados, los sujetos no perciben ninguna variación. Los primeros resultados obtenidos, proporcionando información respecto a la dependencia del ángulo, llevan a una nueva consideración en el campo de la acústica, y en la realización de nuevos proyectos en el futuro. Para futuras líneas de investigación, las simulaciones se deberían realizar con distintos tipos de recintos, buscando escenarios con geometrías irregulares. También, la implementación de distintos materiales para obtener resultados más certeros. Otra de las fases de los futuros proyectos puede realizarse teniendo en cuenta el coeficiente de dispersión dependiente del ángulo de incidencia de la onda de sonido. En la parte de la evaluación subjetiva, realizar una serie de pruebas de escucha con distintos individuos, incluyendo personas sin una formación relacionada con la ingeniería acústica.
Resumo:
The efficacy of the human papillomavirus type 16 (HPV-16)/HPV-18 AS04-adjuvanted vaccine against cervical infections with HPV in the Papilloma Trial against Cancer in Young Adults (PATRICIA) was evaluated using a combination of the broad-spectrum L1-based SPF10 PCR-DNA enzyme immunoassay (DEIA)/line probe assay (LiPA25) system with type-specific PCRs for HPV-16 and -18. Broad-spectrum PCR assays may underestimate the presence of HPV genotypes present at relatively low concentrations in multiple infections, due to competition between genotypes. Therefore, samples were retrospectively reanalyzed using a testing algorithm incorporating the SPF10 PCR-DEIA/LiPA25 plus a novel E6-based multiplex type-specific PCR and reverse hybridization assay (MPTS12 RHA), which permits detection of a panel of nine oncogenic HPV genotypes (types 16, 18, 31, 33, 35, 45, 52, 58, and 59). For the vaccine against HPV types 16 and 18, there was no major impact on estimates of vaccine efficacy (VE) for incident or 6-month or 12-month persistent infections when the MPTS12 RHA was included in the testing algorithm versus estimates with the protocol-specified algorithm. However, the alternative testing algorithm showed greater sensitivity than the protocol-specified algorithm for detection of some nonvaccine oncogenic HPV types. More cases were gained in the control group than in the vaccine group, leading to higher point estimates of VE for 6-month and 12-month persistent infections for the nonvaccine oncogenic types included in the MPTS12 RHA assay (types 31, 33, 35, 45, 52, 58, and 59). This post hoc analysis indicates that the per-protocol testing algorithm used in PATRICIA underestimated the VE against some nonvaccine oncogenic HPV types and that the choice of the HPV DNA testing methodology is important for the evaluation of VE in clinical trials. (This study has been registered at ClinicalTrials.gov under registration no. NCT00122681.).
Resumo:
PURPOSE: To compare intraocular pressure (IOP) rise in normal individuals and primary open-angle glaucoma patients and the safety and efficacy of ibopamine eye drops in different concentrations as a provocative test for glaucoma. METHODS: Glaucoma patients underwent (same eye) the ibopamine provocative test with two concentrations, 1% and 2%, in a random sequence at least 3 weeks apart, but not more than 3 months. The normal individuals were randomly submitted to one of the concentrations of ibopamine (1% and 2%). The test was considered positive if there was an IOP rise greater than 3 or 4 mmHg at 30 or 45 minutes to test which subset of the test has the best sensitivity (Se)/specificity (Sp). RESULTS: There was no statistically significant difference in any of the IOP measurements, comparing 1% with 2% ibopamine. The IOP was significantly higher at 30 and 45 minutes with both concentrations (p<0.001). The best sensitivity/specificity ratio was achieved with the cutoff point set as greater than 3 mmHg at 45 minutes with 2% ibopamine (area under the ROC curve: 0.864, Se: 84.6%; Sp:73.3%). All patients described a slight burning after ibopamine's instillation. CONCLUSION: 2% ibopamine is recommended as a provocative test for glaucoma. Because both concentrations have similar ability to rise IOP, 1% ibopamine may be used to treat ocular hypotony.
Resumo:
This paper describes a topiramate induced acute bilateral angle-closure glaucoma. This rare adverse effect is an idiosyncratic reaction characterized by uveal effusion and lens forward displacement, leading to increased intraocular pressure and vision loss. We describe a 55 year-old white woman with migraine, spasmodic torticollis and essential tremor, who developed bilateral acute angle-closure glaucoma, one week after starting topiramate 25 mg/day. She was seen at the Ophthalmology Emergency Department of the Fundação João Penido Burnier (Campinas, SP, Brazil) with a 4 hours history of blurry vision, ocular pain and bright flashes vision. Slit lamp examination revealed moderate conjunctival injection and corneal edema, and shallow anterior chambers. Intraocular pressure was 48 mmHg in both eyes. Fundoscopic examination findings were normal. She was treated with timolol, brimonidine, dorzolamide, pilocarpine, prednisone acetate eye drops and acetazolamide. One hour after those measures, as the intraocular pressure was 30 mmHg, she received a manitol intravenous injection and the intraocular pressure normalized. After 24 hours an iridotomy with Yag laser was performed. Topiramate was discontinued and she was totally recovered after one week.
Resumo:
A mordida aberta é uma anomalia com características distintas que, além da complexidade dos múltiplos fatores etiológicos, traz consequências estéticas e funcionais. Muitas alternativas têm sido utilizadas em seu tratamento, entre elas a grade palatina, forças ortopédicas, ajuste oclusal, camuflagem com ou sem exodontias, mini-implantes ou miniplacas e cirurgia ortognática. O diagnóstico preciso e a determinação da etiologia permitem estabelecer os objetivos e o plano de tratamento ideal para essa má oclusão. O presente relato descreve o tratamento de uma má oclusão Classe I de Angle, com padrão esquelético de Classe II e mordida aberta anterior, realizado em duas fases e que foi apresentado à diretoria do Board Brasileiro de Ortodontia e Ortopedia Facial (BBO), representando a categoria 2, como parte dos requisitos para a obtenção do título de Diplomado pelo BBO.
Resumo:
Small angle X-ray scattering (SAXS) images of normal breast tissue and benign and malignant breast tumour tissues, fixed in formalin, were measured at the momentum transfer range of 0.063 nm(-1) <= q (=4 pi sin(theta/2)/lambda) <= 2.720 nm(-1). Four intrinsic parameters were extracted from the scattering profiles (1D SAXS image reduced) and, from the combination of these parameters, another three parameters were also created. All parameters, intrinsic and derived, were subject to discriminant analysis, and it was verified that parameters such as the area of diffuse scatter at the momentum transfer range 0.50 <= q <= 0.56 nm(-1), the ratio between areas of fifth-order axial and third-order lateral peaks and third-order axial spacing provide the most significant information for diagnosis (p < 0.001). Thus, in this work it was verified that by combining these three parameters it was possible to classify human breast tissues as normal, benign lesion or malignant lesion with a sensitivity of 83% and a specificity of 100%.
Resumo:
Objective: To determine whether information from genetic risk variants for diabetes is associated with cardiovascular events incidence. Methods: From the about 30 known genes associated with diabetes, we genotyped single-nucleotide polymorphisms at the 10 loci most associated with type-2 diabetes in 425 subjects from the MASS-II Study, a randomized study in patients with multi-vessel coronary artery disease. The combined genetic information was evaluated by number of risk alleles for diabetes. Performance of genetic models relative to major cardiovascular events incidence was analyzed through Kaplan-Meier curve comparison and Cox Hazard Models and the discriminatory ability of models was assessed for cardiovascular events by calculating the area under the ROC curve. Results: Genetic information was able to predict 5-year incidence of major cardiovascular events and overall-mortality in non-diabetic individuals, even after adjustment for potential confounders including fasting glycemia. Non-diabetic individuals with high genetic risk had a similar incidence of events then diabetic individuals (cumulative hazard of 33.0 versus 35.1% of diabetic subjects). The addition of combined genetic information to clinical predictors significantly improved the AUC for cardiovascular events incidence (AUC = 0.641 versus 0.610). Conclusions: Combined information of genetic variants for diabetes risk is associated to major cardiovascular events incidence, including overall mortality, in non-diabetic individuals with coronary artery disease.
Resumo:
We have investigated the structure of disordered gold-polymer thin films using small angle x-ray scattering and compared the results with the predictions of a theoretical model based on two approaches-a structure form factor approach and the generalized Porod law. The films are formed of polymer-embedded gold nanoclusters and were fabricated by very low energy gold ion implantation into polymethylmethacrylate (PMMA). The composite films span (with dose variation) the transition from electrically insulating to electrically conducting regimes, a range of interest fundamentally and technologically. We find excellent agreement with theory and show that the PMMA-Au films have monodispersive or polydispersive characteristics depending on the implanted ion dose. (C) 2010 American Institute of Physics. [doi:10.1063/1.3493241]
Resumo:
The combined effects of concentration and pH on the conformational states of bovine serum albumin (BSA) are investigated by small-angle x-ray scattering. Serum albumins, at physiological conditions, are found at concentrations of similar to 35-45 mg/mL (42 mg/mL in the case of humans). In this work, BSA at three different concentrations (10, 25, and 50 mg/mL) and pH values (2.0-9.0) have been studied. Data were analyzed by means of the Global Fitting procedure, with the protein form factor calculated from human serum albumin (HSA) crystallographic structure and the interference function described, considering repulsive and attractive interaction potentials within a random phase approximation. Small-angle x-ray scattering data show that BSA maintains its native state from pH 4.0 up to 9.0 at all investigated concentrations. A pH-dependence of the absolute net protein charge is shown and the charge number per BSA is quantified to 10(2), 8(l), 13(2), 20(2), and 26(2) for pH values 4.0, 5.4, 7.0, 8.0, and 9.0, respectively. The attractive potential diminishes as BSA concentration increases. The coexistence of monomers and dimers is observed at 50 mg/mL and pH 5.4, near the BSA isoelectric point. Samples at pH 2.0 show a different behavior, because BSA overall shape changes as a function of concentration. At 10 mg/mL, BSA is partially unfolded and a strong repulsive protein-protein interaction occurs due to the high amount of exposed charge. At 25 and 50 mg/mL, BSA undergoes some refolding, which likely results in a molten-globule state. This work concludes by confirming that the protein concentration plays an important role on the pH-unfolded BSA state, due to a delicate compromise between interaction forces and crowding effects.
Resumo:
This paper describes a new and simple method to determine the molecular weight of proteins in dilute solution, with an error smaller than similar to 10%, by using the experimental data of a single small-angle X-ray scattering (SAXS) curve measured on a relative scale. This procedure does not require the measurement of SAXS intensity on an absolute scale and does not involve a comparison with another SAXS curve determined from a known standard protein. The proposed procedure can be applied to monodisperse systems of proteins in dilute solution, either in monomeric or multimeric state, and it has been successfully tested on SAXS data experimentally determined for proteins with known molecular weights. It is shown here that the molecular weights determined by this procedure deviate from the known values by less than 10% in each case and the average error for the test set of 21 proteins was 5.3%. Importantly, this method allows for an unambiguous determination of the multimeric state of proteins with known molecular weights.
Resumo:
In this work, quaternary conformational studies of peanut agglutinin (PNA) have been carried out using small-angle X-ray scattering (SAXS). PNA was submitted to three different conditions: pH variation (2.5, 4.0, 7.4 and 9.0), guanidine hydrochloride presence (0.5-2 M) at each pH value, and temperature ranging from 25 to 60 degrees C. All experiments were performed in the absence and presence of T-antigen to evaluate its influence on the lectin stability. At room temperature and pH 4.0,7.4 and 9.0, the SAXS curves are consistent with the PNA scattering in its crystallographic native homotetrameric structure, with monomers in a jelly roll fold, associated by non-covalent bonds resulting in an open structure. At pH 2.5, the results indicate that PNA tends to dissociate into smaller sub-units, as dimers and monomers, followed by a self-assembling into larger aggregates. Furthermore, the conformational stability under thermal denaturation follows the pH sequence 7.4 > 9.0 > 4.0 > 2.5. Such results are consistent with the conformational behavior found upon GndHCl influence. The presence of T-antigen does not affect the protein quaternary structure in all studied systems within the SAXS resolution. (C) 2010 Elsevier B.V. All rights reserved.