976 resultados para heat load index


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Environmental heat can reduce conception rates (the proportion of services that result in pregnancy) in lactating dairy cows. The study objectives were to identify periods of exposure relative to the service date in which environmental heat is most closely associated with conception rates, and to assess whether the total time cows are exposed to high environmental heat within each 24-h period is more closely associated with conception rates than is the maximum environmental heat for each 24-h period. A retrospective observational study was conducted in 25 predominantly Holstein-Friesian commercial dairy herds located in Australia. Associations between weather and conception rates were assessed using 16,878 services performed over a 21-mo period. Services were classified as successful based on rectal palpation. Two measures of heat load were defined for each 24-h period: the maximum temperature-humidity index (THI) for the period, and the number of hours in the 24-h period when the THI was >72. Conception rates were reduced when cows were exposed to a high heat load from the day of service to 6 d after service, and in wk -1. Heat loads in wk -3 to -5 were also associated with reduced conception rates. Thus, management interventions to ameliorate the effects of heat load on conception rates should be implemented at least 5 wk before anticipated service and should continue until at least 1 wk after service. High autocorrelations existed between successive daily values in both measures, and associations between day of heat load relative to service day and conception rates differed substantially when ridge regression was used to account for this autocorrelation. This indicates that when assessing the effects of heat load on conception rates, the autocorrelation in heat load between days should be accounted for in analyses. The results suggest that either weekly averages or totals summarizing the daily heat load are adequate to describe heat load when assessing effects on conception rates in lactating dairy cows.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To investigate the extent of heat load problems, caused by the combination of excessive temperature and humidity, in Holstein-Friesian cows in Australia. Also, to outline how milk production losses and consequent costs from this can be estimated and minimised. Procedures Long-term meteorological data for Australia were analysed to determine the distribution of hot conditions over space and time. Fifteen dairy production regions were identified for higher-resolution data analysis. Both the raw meteorological data and their integration into a temperature-humidity thermal index were compiled onto a computer program. This mapping software displays the distribution of climatic patterns, both Australia-wide and within the selected dairying regions. Graphical displays of the variation in historical records for 200 locations in the 15 dairying regions are also available. As a separate study, production data from research stations, on-farm trials and milk factory records were statistically analysed and correlated with the climatic indices, to estimate production losses due to hot conditions. Results Both milk yields and milk constituents declined with increases in the temperature-humidity index. The onset and rate of this decline are dependent on a number of factors, including location, level of production, adaptation, and management regime. These results have been integrated into a farm-level economic analysis for managers of dairy properties. Conclusion By considering the historical patterns of hot conditions over time and space, along with expected production losses, managers of dairy farms can now conduct an economic evaluation of investment strategies to alleviate heat loads. These strategies include the provision of sprinklers, shade structures, or combinations of these.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Loop heat pipe is a passive two-phase heat transport device that is gaining importance as a part of spacecraft thermal control systems and also in applications (such as in avionic cooling and submarines). Hard fill of a loop heat pipe occurs when the compensation chamber is full of liquid. A theoretical study is undertaken to investigate the issues underlying the loop beat pipe hard-fill phenomenon. The results of the study suggest that the mass of charge and the presence of a bayonet have significant impact on the loop heat pipe operation. With a largern mass of charge, a loop heat pipe hard fills at a lower heat load. As the heat load increases, there is a steep rise in the loop heat pipe operating temperature. In a loop heat pipe with a saturated compensation chamber, and also in a hard-filled loop heat pipe without a bayonet, the temperature of the compensation chamber and that of the liquid core are nearly equal. When a loop heat pipe with a bayonet hard fills, the compensation chamber and the evaporator core temperatures are different.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Phase-change cooling technique is a suitable method for thermal management of electronic equipment subjected to transient or cyclic heat loads. The thermal performance of a phase-change based heat sink under cyclic heat load depends on several design parameters, namely, applied heat flux, cooling heat transfer coefficient, thermophysical properties of phase-change materials (PCMs), and physical dimensions of phase-change storage system during melting and freezing processes. A one-dimensional conduction heat transfer model is formulated to evaluate the effectiveness of preliminary design of practical PCM-based energy storage units. In this model, the phase-change process of the PCM is divided into melting and solidification subprocesses, for which separate equations are written. The equations are solved sequentially and an explicit closed-form solution is obtained. The efficacy of analytical model is estimated by comparing with a finite-volume-based numerical solution for both transient and cyclic heat loads.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We investigate the steady state natural ventilation of a room heated at the base and consisting of two vents at different levels. We explore how the air flow rate and internal temperature relative to the exterior vary as a function of the vent areas, position of the vents and heat load in order to establish appropriate ventilation strategies for a room. When the room is heated by a distributed source, the room becomes well mixed and the steady state ventilation rate depends on the heating rate, the area of the vents and the distance between the lower and upper level vents. However, when the room is heated by a localised source the room becomes stratified. If the effective ventilation area is sufficiently large, then the interface separating the two layers lies above the inlet vent and the lower layer is comprised of ambient fluid. In this case the upper layer is warmer than in the well mixed case and the ventilation rate is smaller. However, if the effective area for ventilation is sufficiently small, then the interface separating the two layers lies below the inlet vent and the lower layer is comprised of warm fluid which originates as the cold incoming fluid mixes during descent from the vent through the upper layer. In this case both the ventilation rate and the upper layer temperature are the same as in the case of a distributed heat load. As the vertical separation between lower and upper level vents decreases, then the temperature difference between the layers falls to zero and the room becomes approximately well mixed. These findings suggest how the appropriate ventilation strategy for a room can be varied depending on the exterior temperature, with mixing ventilation more suitable for winter conditions and displacement ventilation for warmer external temperatures.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper considers the effect of the rotor tip on the casing heat load of a transonic axial flow turbine. The aim of the research is to understand the dominant causes of casing heat-transfer. Experimental measurements were conducted at engine-representative Mach number, Reynolds number and stage inlet to casing wall temperature ratio. Time-resolved heat-transfer coefficient and gas recovery temperature on the casing were measured using an array of heat-transfer gauges. Time-resolved static pressure on the casing wall was measured using Kulite pressure transducers. Time-resolved numerical simulations were undertaken to aid understanding of the mechanism responsible for casing heat load. The results show that between 35% and 60% axial chord the rotor tip-leakage flow is responsible for more than 50% of casing heat transfer. The effects of both gas recovery temperature and heat transfer coefficient were investigated separately and it is shown that an increased stagnation temperature in the rotor tip gap dominates casing heat-transfer. In the tip gap the stagnation temperature is shown to rise above that found at stage inlet (combustor exit) by as much as 35% of stage total temperature drop. The rise in stagnation temperature is caused by an isentropic work input to the tip-leakage fluid by the rotor. The size of this mechanism is investigated by computationally tracking fluid path-lines through the rotor tip gap to understand the unsteady work processes that occur. Copyright © 2005 by ASME.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Multiple regression analysis is a statistical technique which allows to predict a dependent variable from m ore than one independent variable and also to determine influential independent variables. Using experimental data, in this study the multiple regression analysis is applied to predict the room mean velocity and determine the most influencing parameters on the velocity. More than 120 experiments for four different heat source locations were carried out in a test chamber with a high level wall mounted air supply terminal at air change rates 3-6 ach. The influence of the environmental parameters such as supply air momentum, room heat load, Archimedes number and local temperature ratio, were examined by two methods: a simple regression analysis incorporated into scatter matrix plots and multiple stepwise regression analysis. It is concluded that, when a heat source is located along the jet centre line, the supply momentum mainly influences the room mean velocity regardless of the plume strength. However, when the heat source is located outside the jet region, the local temperature ratio (the inverse of the local heat removal effectiveness) is a major influencing parameter.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study aimed at evaluating the thermal performance of a modular ceiling system for poultry houses. The reduced- and distorted-scale prototypes used ceiling modules made of reforested wood and were covered with recycled long-life package tiles. The following parameters were measured for 21 days: the internal surface temperature (ST), globe temperature and humidity index (WBGT), and radiant heat load (RHL). Measurements were made at times of highest heat load (11:00 am, 13:00 pm, and 03:00 pm). Collected data were analyzed by ""R"" statistics software. Means were compared by multiple comparison test (Tukey) and linear regression was performed, both at 5% significance level. The results showed that the prototype with the ceiling was more efficient to reduce internal tile surface temperature; however, this was not sufficient to provide a comfortable environment for broilers during the growout. Therefore, other techniques to provide proper cooling are required in addition to the ceiling

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The production of alumina involves the use of a process known as the Bayer process. This method involves the digestion of raw bauxite in sodium hydroxide at temperatures around 250°C. The resultant pregnant liquor then goes through a number of filtering and precipitation processes to obtain the aluminium oxide crystals which are then calcined to obtain the final product. The plant is situated in a sub tropical climate in Northern Australia and this combined with the hot nature of the process results in a potential for heat related illnesses to develop. When assessing a work environment for heat stress a heat stress index is often employed as a guideline and to date the Wet Bulb Globe Temperature (WBGT) has been the recommended index. There have been concerns over the past that the WBGT is not suited to the Northern Australian climate and in fact studies in other countries have suggested this is the case. This study was undertaken in the alumina plant situated in Gladstone Queensland to assess if WBGT was in fact the most suitable index for use or if another was more applicable. To this end three indices, Wet Bulb Globe Temperature (WBGT), Heat Stress Index (HSI) and Required Sweat Rate (SWreq) were compared and assessed using physiological monitoring of heart rate and surrogate core temperature. A number of different jobs and locations around the plant were investigated utilising personal and environmental monitoring equipment. These results were then collated and analysed using a computer program written as part of the study for the manipulation of the environmental data . Physiological assessment was carried out using methods approved by international bodies such as National Institute for Occupational Safety & Health (NIOSH) and International Standards Organisation (ISO) and incorporated the use of a ‘Physiological Factor’ developed to enable the comparison of predicted allowable exposure times and strain on the individual. Results indicated that of the three indices tested, Required Sweat Rate was found to be the most suitable for the climate and in the environment of interest. The WBGT system was suitable in areas in the moderate temperature range (ie 28 to 32°C) but had some deficiencies above this temperature or where the relative humidity exceeded approximately 80%. It was however suitable as a first estimate or first line indicator. HSI over-estimated the physiological strain in situations of high temperatures, low air flows and exaggerated the benefit of artificial air flows on the worker in certain environments ie. fans.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Over recent years the structural ceramics industry in Brazil has found a very favorable market for growth. However, difficulties related to productivity and product quality are partially inhibiting this possible growth. An alternative for trying to solve these problems and, thus, provide the pottery industry the feasibility of full development, is the substitution of firewood used in the burning process by natural gas. In order to contribute to this process of technological innovation, this paper studies the effect of co-use of ceramic phyllite and kaolin waste on the properties of a clay matrix, verifying the possible benefits that these raw materials can give to the final product, as well as the possibility of such materials to reduce the heat load necessary to obtain products with equal or superior quality. The study was divided into two steps: characterization of materials and study of formulations. Two clays, a phyllite and a residue of kaolin were characterized by the following techniques: laser granulometry, plasticity index by Atterberg limits, X-ray fluorescence, X-ray diffraction, mineralogical composition by Rietveld, thermogravimetric and differential thermal analysis. To study the formulations, specifically for evaluation of technological properties of the parts, was performed an experimental model that combined planning involving a mixture of three components (standard mass x phyllite x kaolin waste) and a 23 factorial design with central point associated with thermal processing parameters. The experiment was performed with restricted strip-plot randomization. In total, 13 compositional points were investigated within the following constraints: phyllite ≤ 20% by weight, kaolin waste ≤ 40% by weight, and standard mass ≥ 60% by weight. The thermal parameters were used at the following levels: 750 and 950 °C to the firing temperature, 5 and 15 °C/min at the heating rate, 15 and 45min to the baseline. The results showed that the introduction of phyllite and/or kaolin waste in ceramic body produced a number of benefits in properties of the final product, such as: decreased absorption of water, apparent porosity and linear retraction at burn; besides the increase in apparent specific mass and mechanical properties of parts. The best results were obtained in the compositional points where the sum of the levels of kaolin waste and phyllite was maximal (40% by weight), as well as conditions which were used in firing temperatures of 950 °C. Regarding the prospect of savings in heat energy required to form the desired microstructure, the phyllite and the residue of kaolin, for having small particle sizes and constitutions mineralogical phases with the presence of fluxes, contributed to the optimization of the firing cycle.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of the present study was to evaluate the effects of different dietary energy levels and stocking densities on the thermoregulating parameters, live performance, and carcass traits of broilers reared under tropical winter conditions at different times of the day. In total, 1,312 one-d-old male broilers were used. Birds were allotted to three different stocking densities (10, 14 or 18 birds/m²) and two dietary energy levels (2900 or 3200 kcal ME/kg). The following parameters were evaluated:radiant heat load (RHL), rectal temperature (RT), feed intake (FI), weight gain (WG), feed conversion ratio (FCR), livability (L), production of live weight per area (WA), and carcass yield. Stocking density did not affect sensible heat loss (SRL) or rectal temperature (RT); however, as expected, sensible heat loss (SRL) and RT were influenced by time of the day, with higher values in the morning and in the afternoon, respectively. There was no effect of treatment (p>0.05) on carcass or parts yield. Feed intake was reduced in 3%, whereas weight gain and feed conversion ratio improved in 8 and 10%, respectively, as dietary energy level increased. on the other hand, stocking density did not influence live performance or carcass traits. Based on the present results, it is concluded that sensible heat loss depends on dietary energy levels and particularly on time of the day. Therefore, environmental house management is suggested during tropical winters in order to reduce differences between broiler skin and environmental temperatures in the morning and in the afternoon.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Utilizaram-se 45 fêmeas ovinas adultas (15 Hampshire Down [HD], 15 Texel [TE] e 15 Ile de France [IF]), para propor um zoneamento bioclimático da ovinocultura no Estado do Paraná. Mediram-se a temperatura retal (Tr), da epiderme (Te), do interior do velo (Tiv) e da superfície do velo (Tsv); a frequência respiratória (Fr); a temperatura do ar (Ta), pressão de vapor (e), velocidade do vento (v) e carga térmica radiante (CTR). O Índice de Conforto Térmico utilizado foi ICT= 0,6678Ta + 0,4969e + 0,5444Tg + 0,1038v. A regressão do ICT sobre Tr mostrou efeito quadrático para as três raças. Para ICT=24,3, 27,3 e 20,6, os valores de Tr foram respectivamente: 39,10ºC para a raça HD, 39,05ºC para TE e 39,09ºC para IF, atingindo 40,40; 40,50; e 40,28ºC, respectivamente, para ICT=58. As três raças aumentaram sua Tr a partir de ICT=26, com a TE apresentando menor Tr até o valor ICT=46; neste ponto, as três raças foram semelhantes, tendo a TE apresentado maiores valores. Para ICT igual a 27,6; 29,7; e 27,0, os valores de Fr foram, respectivamente, 89,63; 77,08; e 78,77 resp./min., para as raças HD, TE e IF. A raça TE apresentou menor Fr (77,08 resp./min.), para ICT=29,7 e para ICT=48, valores semelhantes aos da IF (181,96 resp./min.); a partir deste índice, passou a ser maior que as demais raças, atingindo valores de 288,66 resp./min. no ICT=56, porém inferior à HD (289,01 resp./min.). Neste índice, a raça IF foi a que apresentou a menor Fr (275,72 resp./min.). Uma extensa faixa ao longo do litoral do Estado, entrando cerca de 200 km para o interior até os limites das cidades de Castro, Telêmaco Borba, Laranjeiras do Sul e Pato Branco, permite a criação das três raças, sem exigir grandes esforços de termorregulação.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study aimed at evaluating the thermal performance of a modular ceiling system for poultry houses. The reduced- and distorted-scale prototypes used ceiling modules made of reforested wood and were covered with recycled long-life package tiles. The following parameters were measured for 21 days: tile internal surface temperature (ST), globe temperature and humidity index (WBGT), and radiant heat load (RHL). Measurements were made at times of highest heat load (11:00 am, 13:00 pm, and 03:00 pm). Collected data were analyzed by R statistics software. Means were compared by multiple comparison test (Tukey) and linear regression was performed, both at 5% significance level. The results showed that the prototype with the ceiling was more efficient to reduce internal tile surface temperature; however, this was not sufficient to provide a comfortable environment for broilers during the growout. Therefore, other techniques to provide proper cooling are required in addition to the ceiling.