994 resultados para gap size


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The type and thickness of insulation on the topside horizontal of cold pitched roofs has a significant role in controlling air movement, energy conservation and moisture transfer reduction through the ceiling to the loft (roof void) space. To investigate its importance, a numerical model using a HAM software package on a Matlab platform with a Simulink simulation tool has been developed using insitu measurements of airflows from the dwelling space through the ceiling to the loft of three houses of different configurations and loft space. Considering typical UK roof underlay (i.e. bituminous felt and a vapour permeable underlay), insitu measurements of the 3 houses were tested using a calibrated passive sampling technique. Using the measured airflows, the effect of air movement on three types of roof insulation (i.e. fibreglass, cellulose and foam) was modelled to investigate associated energy losses and moisture transport. The thickness of the insulation materials were varied but the ceiling airtightness and eaves gap size were kept constant. These instances were considered in order to visualize the effects of the changing parameters. In addition, two different roof underlays of varying resistances were considered and compared to access the influence of the underlay, if any, on energy conservation. The comparison of these insulation materials in relation to the other parameters showed that the type of insulation material and thickness, contributes significantly to energy conservation and moisture transfer reduction through the roof and hence of the building as a whole.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The consolidation and bond strength of rafted sea ice were investigated through a series of experiments undertaken in the Ice Physics Laboratory at the UCL. To simulate a section of rafted sea ice, blocks of laboratory grown saline ice were stacked in an insulated tank with spacers between adjacent blocks to allow saline water to flood in. The rate of consolidation was then monitored using a combination of temperature readings recorded in the ice and liquid layer, salinity measurements of the liquid layer, and cores taken at specific times of interest. Two states of consolidation were observed: thermodynamic consolidation where the ice blocks were physically bonded but the bond strength was weak, and mechanical consolidation where the bond had reached full strength. Results showed that the rafted ice had physically bonded in less than a day, however it took many more days (6 to 30 depending on the environmental conditions) for the bond to reach maximum strength. Increasing the thickness of the ice, the salinity of the water and the inter-block gap size all increased the consolidation time. Once consolidated, ice cores were taken and sheared using the asymmetric four-point bending method to measure the strength of the bond between the ice blocks. These were then compared to the shear strength of solid ice blocks simulating level sea ice. Our results show that the shear strength of the bond between the rafted ice blocks is about 30% weaker than that of level ice.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

© 2015 Elsevier Ltd. All rights reserved. Factors affecting the effectiveness of cathodic protection under disbonded coatings were studied using a partially covered two dimensional electrode array that simulates a crevice under a disbonded coating and allows for the mapping of electrochemical currents under the influence of cathodic protection (CP). This technique enabled the study of the effects of major factors, including crevice gap size, solution conductivity and applied CP potential on the distribution and evolution of CP currents over the electrode array surface. The effect of each of these factors on the overall current distribution profile has been explained using a new electrochemical model. This model suggests that, despite the detrimental effect of cathodic shielding, the steel under disbonded areas could still be protected, independent of the crevice geometry and solution resistivity, by means of concentration polarization instead of direct electrochemical polarization. A set of conditions for maintaining CP potentials more negative than -850 mVCSE along disbonded coating areas was deduced from the proposed model and validated against potential profiles available in the literature. The possible practical implications of the current mapping technique used in this study for developing in-situ CP monitoring sensors has also been discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nasoendoscopy is an important tool for assessing velopharyngeal function. The purpose of this study was to analyze velar and pharyngeal wall movement and velopharyngeal gap during nasoendoscopic evaluation of the velopharynx before and during diagnostic therapy. Nasoendoscopic recordings of 10 children with operated cleft lip and palate were analyzed according to the International Working Group Guidelines. Ratings of movement of velum and pharyngeal walls, and size, location and shape of gaps were analyzed by 3 speech-language pathologists (SLPs). Imaging was obtained during repetitions of the syllable /pa/ during a single nasoendoscopic evaluation: (a) before diagnostic therapy, and (b) after the children were instructed to impound and increase intraoral air pressure (diagnostic therapy). Once the patients impounded and directed air pressure orally, the displacement of the velum, right, left and posterior pharyngeal walls increased 40, 70, 80, and 10%, respectively. Statistical significance for displacement was found only for right and left lateral pharyngeal walls. Reduction in gap size was observed for 30% of the patients and other 40% of the gaps disappeared. Changes in gap size were found to be statistically significant between the two conditions. In nasoendoscopic assessment, the full potential of velopharyngeal displacement may not be completely elicited when the patient is asked only to repeat a speech stimulus. Optimization of information can be done with the use of diagnostic therapy's strategies to manipulate VP function. Assuring the participation of the SLP to conduct diagnostic therapy is essential for management of velopharyngeal dysfunction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: The aim of this in vitro study was to analyze the effect of glass-ionomer cement as a liner on the dentin/resin adhesive interface of lateral walls of occlusal restorations after thermocycling.Materials and Methods: Occlusal cavities were prepared in 60 human molars, divided into six groups: no liner (1 and 4); glass-ionomer cement (GIC, Ketac Molar Easymix, 3M ESPE) (2 and 5); and resin-modified glass-ionomer cement (RMGIC, Vitrebond, 3M ESPE) (3 and 6). Resin composite (Filtek Z250, 3M ESPE) was placed after application of an adhesive system (Adper Single Bond 2, 3M ESPE) that was mixed with a fluorescent reagent (Rhodamine B) to allow confocal microscopy analysis. Specimens of groups 4, 5 and 6 were thermocycled (5 degrees C-55 degrees C) with a dwell time of 30 seconds for 5000 cycles. After this period, teeth were sectioned in approximately 0.8-mm slices. One slice of each tooth was randomly selected for confocal microscopy analysis. The other slices were sectioned into 0.8 nun x 0.8 mm beams, which were submitted to microtensile testing (MPa). Data were analyzed using two-way ANOVA and Tukey test (p < 0.05).Results: There was no detectedstatistical difference on bond strength among groups (alpha < 0.05). Confocal microscopy analysis showed a higher mean gap size in group 4(12.5 mu m) and a higher percentage of marginal gaps in the thermocycled groups. The RNIGIC liner groups showed the lowest percentage of marginal gaps.Conclusions: Lining with RMGIC resulted in less gap formation at the dentin/resin adhesive interface after artificial aging. RMGIC or GIC liners did not alter the microtensile bond strength of adhesive system/resin composite to dentin on the lateral walls of Class I restorations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The recent advances and promises in nanoscience and nanotechnology have been focused on hexagonal materials, mainly on carbon-based nanostructures. Recently, new candidates have been raised, where the greatest efforts are devoted to a new hexagonal and buckled material made of silicon, named Silicene. This new material presents an energy gap due to spin-orbit interaction of approximately 1.5 meV, where the measurement of quantum spin Hall effect(QSHE) can be made experimentally. Some investigations also show that the QSHE in 2D low-buckled hexagonal structures of germanium is present. Since the similarities, and at the same time the differences, between Si and Ge, over the years, have motivated a lot of investigations in these materials. In this work we performed systematic investigations on the electronic structure and band topology in both ordered and disordered SixGe1-x alloys monolayer with 2D honeycomb geometry by first-principles calculations. We show that an applied electric field can tune the gap size for both alloys. However, as a function of electric field, the disordered alloy presents a W-shaped behavior, similarly to the pure Si or Ge, whereas for the ordered alloy a V-shaped behavior is observed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In der vorliegenden Arbeit wurden die durch Training induzierten motorischen Gedächtnisleistungen der Taufliege Drosophila melanogaster beim Überklettern von acht symmetrisch verteilten Lücken auf einem rotierenden Ring untersucht. Durch den auf sie einwirkenden optischen Fluss der vorbeiziehenden äußeren Umgebung wurden die Fliegen angeregt, diesem optomotorischen Reiz entgegenzuwirken und die Lücken laufend zu überqueren. Durch Training verbessert und langfristig gelernt wird die kompensatorische Lückenüberquerung X+ gegen die Rotation. In der aus diesem Training erhaltenen Lernkurve war eine überdurchschnittlich hohe Leistungsverbesserung nach einem einzigen Trainingslauf mit einem zeitlichen Bestand von ca. 40 Minuten abzulesen, um danach vom motorischen Gedächtnisspeicher trainierter Fliegen nicht mehr abgerufen werden zu können. Nach einer Ruhephase von einem bis mehreren Tagen wurden die Fliegen auf mögliche Langzeitlernleistungen untersucht und diese für verschiedene Intervalle nachgewiesen. Sowohl die Leistungsverbesserung während des Trainings, als auch der Lerneffekt nach 24h bleiben in mutanten rutabaga2080 sowie rut1 Fliegen aus. Betroffen ist das Gen der Adenylylzyklase I, ein Schlüsselprotein der cAMP-Signalkaskade, die u.a. im olfaktorischen und visuellen Lernen gebraucht wird. Damit ergab sich die Möglichkeit die motorischen Gedächtnisformen durch partielle Rettung zu kartieren. Die motorische Gedächtniskonsolidierung ist schlafabhängig. Wie sich herausstellte, benötigen WTB Fliegen nur eine Dunkelphase von 10h zwischen einem ersten Trainingslauf und einem Testlauf um signifikante Leistungssteigerungen zu erzielen. In weiterführenden Versuchen wurden die Fliegen nachts sowie tagsüber mit einer LED-Lampe oder in einer Dunkelkammer, mit einem Kreisschüttler oder einer Laborwippe depriviert, mit dem Ergebnis, dass nur jene Fliegen ihre Leistung signifikant gegenüber einem ersten Trainingslauf verbessern konnten, welche entweder ausschließlich der Dunkelheit ausgesetzt waren oder welchen die Möglichkeit gegeben wurde, ein Gedächtnis zunächst in einer natürlichen Schlafphase zu konsolidieren (21Uhr bis 7Uhr MEZ). In weiteren Experimenten wurden die experimentellen Bedingungen entweder während des Trainings oder des Tests auf eine Fliege und damit verbunden auf eine erst durch das Training mögliche motorische Gedächtniskonsolidierung einwirken zu können, untersucht. Dazu wurden die Experimentparameter Lückenweite, Rotationsrichtung des Lückenringes, Geschwindigkeit des Lückenringes sowie die Verteilung der acht Lücken auf dem Ring (symmetrisch, asymmetrisch) im Training oder beim Gedächtnisabruf im Testlauf verändert. Aus den Ergebnissen kann geschlussfolgert werden, dass die Lückenweite langzeitkonsolidiert wird, die Rotationsrichtung kurzzeitig abgespeichert wird und die Drehgeschwindigkeit motivierend auf die Fliegen wirkt. Die symmetrische Verteilung der Lücken auf dem Ring dient der Langzeitkonsolidierung und ist als Trainingseingang von hoher Wichtigkeit. Mit Hilfe verschiedener Paradigmen konnten die Leistungsverbesserungen der Fliegen bei Abruf eines Kurz- bzw. Langzeitgedächtnisses hochauflösend betrachtet werden (Transfer). Die Konzentration, mit der eine WTB Fliege eine motorische Aufgabe - die Überquerung von Lücken entgegengesetzt der Rotationsrichtung - durchführt, konnte mit Hilfe von Distraktoreizen bestimmt werden. Wie sich herausstellte, haben Distraktoren einen Einfluss auf die Erfolgsquote einer Überquerung, d.h. mit zunehmender Distraktionsstärke nahm die Wahrscheinlichkeit einer Lückenüberquerung ab. Die Ablenkungsreize wirkten sich weiterhin auf die Vermessung einer Lücke aus, in dem entweder "peering"-artigen Bewegungen im Training durchgeführt wurden oder je nach Reizstärke ausschließlich nur jene Lücken vermessen wurden, welche auch überquert werden sollten.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Am Mainzer Mikrotron MAMI wurde ein neuartiges Interferometer entwickelt und getestet, mit dem magneto-optische Effekte an dünnen, freitragenden Folien von 3d-Übergangsmetallen wie Eisen, Kobalt oder Nickel an den L_{2,3}-Absorptionskanten (im Spektralbereich der weichen Röntgenstrahlung) gemessen werden können. Es handelt sich um eine Weiterentwicklung eines an MAMI erprobten Interferometers, das im wesentlichen aus einer kollinearen Anordnung zweier identischer Undulatoren, zwischen die die dünne Probefolie eingebracht wird, und einem Gitterspektrometer besteht. Aus den als Funktion des Abstands der Undulatoren beobachtbaren Intensitätsoszillation lassen sich das Dekrement des Realteils δ und der Absorptionskoeffizient β des komplexen Brechungsindex bestimmen.rnIm Rahmen der vorliegenden Arbeit wurde die Apparatur derart weiterentwickelt, dass auch die magnetisch zirkulare Doppelbrechung Δδ und der magnetisch zirkulare Dichroismus Δβ an den L_{2,3}-Absorptionskanten von Übergangsmetallen gemessen werden können. Der zweite Undulator wurde um die Elektronenstrahlachse um den Winkel Ψ = ±107° drehbar gemacht. Damit dient er auch als Analysator der aus der Folie austretenden elliptisch polarisierten weichen Röntgenstrahlung, für die - wie bei der Faraday-Rotation - die Polarisationsebene gedreht ist. Weiterhin kann die Spaltbreite der 10-poligen Hybrid-Undulatoren mit einer Periodenlänge von 12 mm und damit der Undulatorparameter über eine Antriebsmechanik kontinuierlich variiert werden, wodurch eine optimale Anpassung der Amplituden der Undulatorstrahlung aus den beiden Undulatoren möglich wird. Der maximale Undulatorparameter beträgt K = 1.1. Auch das Spektrometer, das auf einem selbstfokussierenden Gitter mit variierter Liniendichte (im Mittel 1400 Linien / mm) basiert, wurde weiterentwickelt. Als Detektor kommt jetzt eine fensterlose CCD mit 1024 x 1024 Pixeln und einer Pixelgröße von 13 μm x 13 μm zum Einsatz, die im Bildmodus betrieben wird, was die gleichzeitige Messung eines Energieintervalls von ca. 50 eV ermöglicht. Die totale Linienbreite wurde bei einer vertikalen Strahlfleckausdehnung von σ_y = 70 μm (rms) am Neon 1s-3p Übergang bei (867.18 ±0.02) eV zu Δħω = (0.218 ±0.002) eV (FWHM) gemessen. Das hohe Auflösungsvermögen von 4000 und die Möglichkeit der Eichung gegen den 1s-3p Übergang von Neon wurden ausgenutzt, um die Energie der Maxima an den Absorptionskanten von Nickel (weiße Linien) neu zu bestimmen. Die Ergebnisse E_{L_2}=(869.65_{-0.16}^{+0.27}) eV und E_{L_3}=(852.37_{-0.11}^{+0.16}) eV stellen eine Verbesserung früherer Messungen dar, die große Streuungen aufwiesen.rnAus systematischen Messungen als Funktion des Abstandes der Undulatoren und des Drehwinkels Ψ wurden die magnetisch zirkulare Doppelbrechung Δδ im Energiebereich 834 eV ≤ ħω ≤ 885 eV an einer freitragenden, bis zur Sättigung magnetisierten Nickelfolie der Dicke von (96.4 ±2.7) nm gemessen. Sowohl das Auflösungsvermögen als auch die Genauigkeit der Messungen für Δδ übersteigen bekannte Literaturangaben signifikant, so dass eine bisher nicht bekannte Feinstruktur gefunden werden konnte. Außerdem wurde der Betrag des magnetisch zirkularen Dichroismus |Δβ| im Bereich des Maximums an der L_3-Absorptionskante mit hoher Genauigkeit gemessen.rn

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Our research explored the influence of deer and gap size on nitrogen cycling, soil compaction, and vegetation trajectories in twelve canopy gaps of varying sizes in a hemlock-northern hardwood forest. Each gap contained two fenced and two unfenced plots. Gap size, soil compaction, winter deer use, and available nitrogen were measured in 2011. Vegetation was assessed in 2007 and 2011, and non-metric multi-dimensional scaling was used to determine vegetative change. Results show that winter deer use was greater in smaller gaps. Deer accessibility did not influence compaction but did significantly increase total available nitrogen in April. April ammonium, April nitrate, and May nitrate were positively related to gap size. The relationship between gap size and vegetative community change was positive for fenced plots but unrelated for unfenced plots. In conclusion, deer are positively contributing to nitrogen dynamics and altering the relationship between canopy gap size and vegetative community change.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Las fuentes de alimentación de modo conmutado (SMPS en sus siglas en inglés) se utilizan ampliamente en una gran variedad de aplicaciones. La tarea más difícil para los diseñadores de SMPS consiste en lograr simultáneamente la operación del convertidor con alto rendimiento y alta densidad de energía. El tamaño y el peso de un convertidor de potencia está dominado por los componentes pasivos, ya que estos elementos son normalmente más grandes y más pesados que otros elementos en el circuito. Para una potencia de salida dada, la cantidad de energía almacenada en el convertidor que ha de ser entregada a la carga en cada ciclo de conmutación, es inversamente proporcional a la frecuencia de conmutación del convertidor. Por lo tanto, el aumento de la frecuencia de conmutación se considera un medio para lograr soluciones más compactas con los niveles de densidad de potencia más altos. La importancia de investigar en el rango de alta frecuencia de conmutación radica en todos los beneficios que se pueden lograr: además de la reducción en el tamaño de los componentes pasivos, el aumento de la frecuencia de conmutación puede mejorar significativamente prestaciones dinámicas de convertidores de potencia. Almacenamiento de energía pequeña y el período de conmutación corto conducen a una respuesta transitoria del convertidor más rápida en presencia de las variaciones de la tensión de entrada o de la carga. Las limitaciones más importantes del incremento de la frecuencia de conmutación se relacionan con mayores pérdidas del núcleo magnético convencional, así como las pérdidas de los devanados debido a los efectos pelicular y proximidad. También, un problema potencial es el aumento de los efectos de los elementos parásitos de los componentes magnéticos - inductancia de dispersión y la capacidad entre los devanados - que causan pérdidas adicionales debido a las corrientes no deseadas. Otro factor limitante supone el incremento de las pérdidas de conmutación y el aumento de la influencia de los elementos parásitos (pistas de circuitos impresos, interconexiones y empaquetado) en el comportamiento del circuito. El uso de topologías resonantes puede abordar estos problemas mediante el uso de las técnicas de conmutaciones suaves para reducir las pérdidas de conmutación incorporando los parásitos en los elementos del circuito. Sin embargo, las mejoras de rendimiento se reducen significativamente debido a las corrientes circulantes cuando el convertidor opera fuera de las condiciones de funcionamiento nominales. A medida que la tensión de entrada o la carga cambian las corrientes circulantes incrementan en comparación con aquellos en condiciones de funcionamiento nominales. Se pueden obtener muchos beneficios potenciales de la operación de convertidores resonantes a más alta frecuencia si se emplean en aplicaciones con condiciones de tensión de entrada favorables como las que se encuentran en las arquitecturas de potencia distribuidas. La regulación de la carga y en particular la regulación de la tensión de entrada reducen tanto la densidad de potencia del convertidor como el rendimiento. Debido a la relativamente constante tensión de bus que se encuentra en arquitecturas de potencia distribuidas los convertidores resonantes son adecuados para el uso en convertidores de tipo bus (transformadores cc/cc de estado sólido). En el mercado ya están disponibles productos comerciales de transformadores cc/cc de dos puertos que tienen muy alta densidad de potencia y alto rendimiento se basan en convertidor resonante serie que opera justo en la frecuencia de resonancia y en el orden de los megahercios. Sin embargo, las mejoras futuras en el rendimiento de las arquitecturas de potencia se esperan que vengan del uso de dos o más buses de distribución de baja tensión en vez de una sola. Teniendo eso en cuenta, el objetivo principal de esta tesis es aplicar el concepto del convertidor resonante serie que funciona en su punto óptimo en un nuevo transformador cc/cc bidireccional de puertos múltiples para atender las necesidades futuras de las arquitecturas de potencia. El nuevo transformador cc/cc bidireccional de puertos múltiples se basa en la topología de convertidor resonante serie y reduce a sólo uno el número de componentes magnéticos. Conmutaciones suaves de los interruptores hacen que sea posible la operación en las altas frecuencias de conmutación para alcanzar altas densidades de potencia. Los problemas posibles con respecto a inductancias parásitas se eliminan, ya que se absorben en los Resumen elementos del circuito. El convertidor se caracteriza con una muy buena regulación de la carga propia y cruzada debido a sus pequeñas impedancias de salida intrínsecas. El transformador cc/cc de puertos múltiples opera a una frecuencia de conmutación fija y sin regulación de la tensión de entrada. En esta tesis se analiza de forma teórica y en profundidad el funcionamiento y el diseño de la topología y del transformador, modelándolos en detalle para poder optimizar su diseño. Los resultados experimentales obtenidos se corresponden con gran exactitud a aquellos proporcionados por los modelos. El efecto de los elementos parásitos son críticos y afectan a diferentes aspectos del convertidor, regulación de la tensión de salida, pérdidas de conducción, regulación cruzada, etc. También se obtienen los criterios de diseño para seleccionar los valores de los condensadores de resonancia para lograr diferentes objetivos de diseño, tales como pérdidas de conducción mínimas, la eliminación de la regulación cruzada o conmutación en apagado con corriente cero en plena carga de todos los puentes secundarios. Las conmutaciones en encendido con tensión cero en todos los interruptores se consiguen ajustando el entrehierro para obtener una inductancia magnetizante finita en el transformador. Se propone, además, un cambio en los señales de disparo para conseguir que la operación con conmutaciones en apagado con corriente cero de todos los puentes secundarios sea independiente de la variación de la carga y de las tolerancias de los condensadores resonantes. La viabilidad de la topología propuesta se verifica a través una extensa tarea de simulación y el trabajo experimental. La optimización del diseño del transformador de alta frecuencia también se aborda en este trabajo, ya que es el componente más voluminoso en el convertidor. El impacto de de la duración del tiempo muerto y el tamaño del entrehierro en el rendimiento del convertidor se analizan en un ejemplo de diseño de transformador cc/cc de tres puertos y cientos de vatios de potencia. En la parte final de esta investigación se considera la implementación y el análisis de las prestaciones de un transformador cc/cc de cuatro puertos para una aplicación de muy baja tensión y de decenas de vatios de potencia, y sin requisitos de aislamiento. Abstract Recently, switch mode power supplies (SMPS) have been used in a great variety of applications. The most challenging issue for designers of SMPS is to achieve simultaneously high efficiency operation at high power density. The size and weight of a power converter is dominated by the passive components since these elements are normally larger and heavier than other elements in the circuit. If the output power is constant, the stored amount of energy in the converter which is to be delivered to the load in each switching cycle is inversely proportional to the converter’s switching frequency. Therefore, increasing the switching frequency is considered a mean to achieve more compact solutions at higher power density levels. The importance of investigation in high switching frequency range comes from all the benefits that can be achieved. Besides the reduction in size of passive components, increasing switching frequency can significantly improve dynamic performances of power converters. Small energy storage and short switching period lead to faster transient response of the converter against the input voltage and load variations. The most important limitations for pushing up the switching frequency are related to increased conventional magnetic core loss as well as the winding loss due to the skin and proximity effect. A potential problem is also increased magnetic parasitics – leakage inductance and capacitance between the windings – that cause additional loss due to unwanted currents. Higher switching loss and the increased influence of printed circuit boards, interconnections and packaging on circuit behavior is another limiting factor. Resonant power conversion can address these problems by using soft switching techniques to reduce switching loss incorporating the parasitics into the circuit elements. However the performance gains are significantly reduced due to the circulating currents when the converter operates out of the nominal operating conditions. As the input voltage or the load change the circulating currents become higher comparing to those ones at nominal operating conditions. Multiple Input-Output Many potential gains from operating resonant converters at higher switching frequency can be obtained if they are employed in applications with favorable input voltage conditions such as those found in distributed power architectures. Load and particularly input voltage regulation reduce a converter’s power density and efficiency. Due to a relatively constant bus voltage in distributed power architectures the resonant converters are suitable for bus voltage conversion (dc/dc or solid state transformation). Unregulated two port dc/dc transformer products achieving very high power density and efficiency figures are based on series resonant converter operating just at the resonant frequency and operating in the megahertz range are already available in the market. However, further efficiency improvements of power architectures are expected to come from using two or more separate low voltage distribution buses instead of a single one. The principal objective of this dissertation is to implement the concept of the series resonant converter operating at its optimum point into a novel bidirectional multiple port dc/dc transformer to address the future needs of power architectures. The new multiple port dc/dc transformer is based on a series resonant converter topology and reduces to only one the number of magnetic components. Soft switching commutations make possible high switching frequencies to be adopted and high power densities to be achieved. Possible problems regarding stray inductances are eliminated since they are absorbed into the circuit elements. The converter features very good inherent load and cross regulation due to the small output impedances. The proposed multiple port dc/dc transformer operates at fixed switching frequency without line regulation. Extensive theoretical analysis of the topology and modeling in details are provided in order to compare with the experimental results. The relationships that show how the output voltage regulation and conduction losses are affected by the circuit parasitics are derived. The methods to select the resonant capacitor values to achieve different design goals such as minimum conduction losses, elimination of cross regulation or ZCS operation at full load of all the secondary side bridges are discussed. ZVS turn-on of all the switches is achieved by relying on the finite magnetizing inductance of the Abstract transformer. A change of the driving pattern is proposed to achieve ZCS operation of all the secondary side bridges independent on load variations or resonant capacitor tolerances. The feasibility of the proposed topology is verified through extensive simulation and experimental work. The optimization of the high frequency transformer design is also addressed in this work since it is the most bulky component in the converter. The impact of dead time interval and the gap size on the overall converter efficiency is analyzed on the design example of the three port dc/dc transformer of several hundreds of watts of the output power for high voltage applications. The final part of this research considers the implementation and performance analysis of the four port dc/dc transformer in a low voltage application of tens of watts of the output power and without isolation requirements.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Novel anti-neoplastic agents such as gene targeting vectors and encapsulated carriers are quite large (approximately 100–300 nm in diameter). An understanding of the functional size and physiological regulation of transvascular pathways is necessary to optimize delivery of these agents. Here we analyze the functional limits of transvascular transport and its modulation by the microenvironment. One human and five murine tumors including mammary and colorectal carcinomas, hepatoma, glioma, and sarcoma were implanted in the dorsal skin-fold chamber or cranial window, and the pore cutoff size, a functional measure of transvascular gap size, was determined. The microenvironment was modulated: (i) spatially, by growing tumors in subcutaneous or cranial locations and (ii) temporally, by inducing vascular regression in hormone-dependent tumors. Tumors grown subcutaneously exhibited a characteristic pore cutoff size ranging from 200 nm to 1.2 μm. This pore cutoff size was reduced in tumors grown in the cranium or in regressing tumors after hormone withdrawal. Vessels induced in basic fibroblast growth factor-containing gels had a pore cutoff size of 200 nm. Albumin permeability was independent of pore cutoff size. These results have three major implications for the delivery of therapeutic agents: (i) delivery may be less efficient in cranial tumors than in subcutaneous tumors, (ii) delivery may be reduced during tumor regression induced by hormonal ablation, and (iii) permeability to a molecule is independent of pore cutoff size as long as the diameter of the molecule is much less than the pore diameter.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Replication protein A (RPA), the nuclear single-stranded DNA binding protein is involved in DNA replication, nucleotide excision repair (NER) and homologous recombination. It is a stable heterotrimer consisting of subunits with molecular masses of 70, 32 and 14 kDa (p70, p32 and p14, respectively). Gapped DNA structures are common intermediates during DNA replication and NER. To analyze the interaction of RPA and its subunits with gapped DNA we designed structures containing 9 and 30 nucleotide gaps with a photoreactive arylazido group at the 3′-end of the upstream oligonucleotide or at the 5′-end of the downstream oligonucleotide. UV crosslinking and subsequent analysis showed that the p70 subunit mainly interacts with the 5′-end of DNA irrespective of DNA structure, while the subunit orientation towards the 3′-end of DNA in the gap structures strongly depends on the gap size. The results are compared with the data obtained previously with the primer–template systems containing 5′- or 3′-protruding DNA strands. Our results suggest a model of polar RPA binding to the gapped DNA.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recombinational repair of double-stranded DNA gaps was investigated in Ustilago maydis. The experimental system was designed for analysis of repair of an autonomously replicating plasmid containing a cloned gene disabled by an internal deletion. It was discovered that crossing over rarely accompanied gap repair. The strong bias against crossing over was observed in three different genes regardless of gap size. These results indicate that gap repair in U. maydis is unlikely to proceed by the mechanism envisioned in the double-stranded break repair model of recombination, which was developed to account for recombination in Saccharomyces cerevisiae. Experiments aimed at exploring processing of DNA ends were performed to gain understanding of the mechanism responsible for the observed bias. A heterologous insert placed within a gap in the coding sequence of two different marker genes strongly inhibited repair if the DNA was cleaved at the promoter-proximal junction joining the insert and coding sequence but had little effect on repair if the DNA was cleaved at the promoter-distal junction. Gene conversion of plasmid restriction fragment length polymorphism markers engineered in sequences flanking both sides of a gap accompanied repair but was directionally biased. These results are interpreted to mean that the DNA ends flanking a gap are subject to different types of processing. A model featuring a single migrating D-loop is proposed to explain the bias in gap repair outcome based on the observed asymmetry in processing the DNA ends.