43 resultados para firefighting


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This qualitative research was a constructivist grounded theory designed to develop an understanding of how firefighters perceive and cope with stressful situations and the impact this has on their perceptions of health. This study was framed in a social ecological perspective with the community of firefighting providing the environment within which to explore stress and coping. Of particular concern here are the stressors associated with firefighting. Prior research with firefighters has often been epidemiological and statistical in nature, focusing on measures of cardiovascular disease, cancer, and depression (Baker & Williams, 2001 ; Brown et al., 2002; Murphy et al.,1999; Regehr et al., 2002; Regehr et al., 2003). Qualitative research examining the perception of stress among firefighters that includes personal stories allows firefighters the opportunity to describe what it is like to be met with physically and mentally challenging situations on a daily basis. Twelve in-depth, semi-structured, face-to-face interviews with a brief questionnaire were conducted with firefighters from a Southern Ontario Fire Department. Four main themes emerged describing the persona of the firefighter, the stressors of firefighters, coping strategies of firefighters, and firefighters' perceptions of health. Stressors include requirements of the job, traumatic calls, tensions with co-workers, the struggle between the family at home and the family at work, political stressors with the City, and the inner struggle. Avoidance coping, approach coping, and gaining perspective emerged as the three coping styles of firefighters. Health was defined as including physical, mental, social and spiritual aspects. A model of the findings is provided that depicts the cyclical nature of the stress-coping-health relationship among firefighters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Los bomberos aeronáuticos son los encargados de atender todas las emergencias en los aeropuertos y sus cercanías. Estas emergencias incluyen emergencias aéreas, en tierra, eventos con materiales peligros e incendios, entre otros. Su trabajo tiene como características la realización de actividades durante periodos largos de baja intensidad y periodos cortos de alta intensidad. De acuerdo con estas características, es necesario que los bomberos aeronáuticos tengan una buena condición física. El consumo máximo de oxígeno (VO2 máx) como indicador de capacidad aeróbica resulta indispensable para conocer el desempeño de los bomberos en su trabajo. El objetivo de este estudio es determinar la capacidad aeróbica de los bomberos aeronáuticos y sus factores determinantes. Por tanto se desarrolló un estudio transversal de tipo descriptivo en una muestra de 23 hombres bomberos aeronáuticos. Se obtuvo información acerca de sus variables socio-demográficas, se determinó el VO2 máx y umbral ventilatorio mediante análisis de gases espirados durante un protocolo de ejercicio máximo sobre tapiz rodante, se evaluó la composición corporal mediante adipometría y se determinó el nivel de actividad física mediante el cuestionario internacional de actividad física IPAQ. Se encontró que la muestra tenia una edad de 32,6 ± 4,8 años, peso de 78,4 ± 9,8 kg, porcentaje de grasa de 14,8 ± 3,8 %, índice de masa corporal de 25,7 ± 2,7 y VO2máx de 44,6 ± 6. No se encontraron cambios significativos del VO2máx con la edad, pero si con la actividad física, porcentaje de grasa e índice de masa corporal. Se sugiere que el entrenamiento de los bomberos aeronáuticos durante su jornada laboral sea de intervalos de alta intensidad y que se monitorice su nivel de actividad física y composición corporal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since fighting fires can pose a great risk to the lives of firefighters, it is important to understand how they perceive risks in dynamic wildfire situations. The aim of the current study was to determine whether career and volunteer firefighters differ in their perception of the risk of a going vs. contained fire and whether descriptions of a fire as either going or contained affected perceptions of risk. It was expected that career firefighters would rate a contained fire as significantly riskier than would volunteer firefighters. The sample consisted of 55 career and 84 volunteer CFA Victorian firefighters (134 males and 5 females). An ambiguous wildfire scenario was presented and described as either going or contained and risk ratings were recorded. Two-way ANOVA results showed that career firefighters rated a going fire as equally risky as a contained fire. On the other hand, volunteer firefighters perceived a fire described as contained to be significantly less risky than a fire described as going, despite the fact that the same fireground conditions were described in both cases. It was concluded that a framing effect had occurred and that career firefighters demonstrated a higher level of situation awareness than volunteer firefighters due to their heightened levels of risk perception when exposed to contained wildfire scenarios. A practical implication of the current research is that those conducting firefighting briefings need to be aware of possible framing effects in the way information is presented to firefighters and need to ensure that all briefings make risks cognitively salient to firefighters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Firefighting foams (Class A foams) are an effective and widespread firefighting tool which are frequently used in environmentally sensitive areas. Firefighting foams are known to be ecologically damaging in aquatic environments, however their impacts at the plant species or ecosystem level are relatively unknown. Reports of shoot damage to plants, suppressed flowering, and changes in plant community composition suggested that the ecological damage caused by their use may be unacceptable. However, applications of foam to seedlings of some Australian plant species from representative and widespread families, showed no detectable impacts on a range of vegetative growth characteristics. Application of 1.0% foam to heathland soils showed no detectable impacts on soil invertebrate Orders sampled over several months. The results are encouraging for the continued use of Class A foam as a fire suppression technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aching muscles and joints, lethargy, and sleepiness are all signs of firefighter fatigue during bushfire suppression. If not managed, fatigue may lead to injury or illness for the individual, which may also compromise the safety and productivity of their crew. Understanding the many sources of firefighter fatigue is, therefore, fundamental for all Australian fire agencies. This article will briefly address  several factors thought to contribute to firefighter fatigue including; sleep loss, firefighter’s work activity, their hydration, and nutrition, the hot and smoky  working environment, firefighter’s physical fitness and their experience. This brief overview draws on findings from firefighting research and the broader scientific literature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fighting wildland fire is a physically demanding occupation. Wildland firefighters need to be physically fit to work safely and productively. To determine whether personnel are fit for duty, many firefighting agencies employ physical competency tests, such as the pack hike test (PHT). The PHT involves a 4.83-km hike over level terrain carrying a 20.4-kg pack within a 45-min period. The PHT was devised to test the job readiness of US wildland firefighters but is also currently used by some fire agencies in Australia and Canada. This review discusses the history and development of the PHT with emphasis on the process of test validation. Research-based training advice for the PHT is given, as well as discussion of the risks associated with completing the PHT. Different versions and modifications to the PHT have emerged in recent years and these are discussed with regard to their validity. Finally, this review addresses the relevance and validity of the PHT for Australian and Canadian wildland firefighters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monitoring an individual's thermic state in the workplace requires reliable feedback of their core temperature. However, core temperature measurement technology is expensive, invasive and often impractical in operational environments, warranting investigation of surrogate measures which could be used to predict core temperature. This study examines an alternative measure of an individual's thermic state, thermal sensation, which presents a more manageable and practical solution for Australian firefighters operating on the fireground. Across three environmental conditions (cold, warm, hot & humid), 49 Australian volunteer firefighters performed a 20-min fire suppression activity, immediately followed by 20min of active cooling using hand and forearm immersion techniques. Core temperature (Tc) and thermal sensation (TS) were measured across the rehabilitation period at five minute intervals. Despite the decline in Tc and TS throughout the rehabilitation period, there was little similarity in the magnitude or rate of decline between each measure in any of the ambient conditions. Moderate to strong correlations existed between Tc and TS in the cool (0.41, p<0.05) and hot & humid (0.57, p<0.05) conditions, however this was resultant in strong correlation during the earlier stages of rehabilitation (first five minutes), which were not evident in the latter stages. Linear regression revealed TS to be a poor predictor of Tc in all conditions (SEE=0.45-0.54°C) with a strong trend for TS to over-predict Tc (77-80% of the time). There is minimal evidence to suggest that ratings of thermal sensation, which represent a psychophysical assessment of an individual's thermal comfort, are an accurate reflection of the response of an individual's core temperature. Ratings of thermal sensation can be highly variable amongst individuals, likely moderated by local skin temperature. In account of these findings, fire managers require a more reliable source of information to guide decisions of heat stress management.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To examine the effects of sleep restriction on firefighters' physical task performance during simulated wildfire suppression. METHODS: Thirty-five firefighters were matched and randomly allocated to either a control condition (8-hour sleep opportunity, n = 18) or a sleep restricted condition (4-hour sleep opportunity, n = 17). Performance on physical work tasks was evaluated across three days. In addition, heart rate, core temperature, and worker activity were measured continuously. Rate of perceived and exertion and effort sensation were evaluated during the physical work periods. RESULTS: There were no differences between the sleep-restricted and control groups in firefighters' task performance, heart rate, core temperature, or perceptual responses during self-paced simulated firefighting work tasks. However, the sleep-restricted group were less active during periods of non-physical work compared to the control group. CONCLUSIONS: Under self-paced work conditions, 4 h of sleep restriction did not adversely affect firefighters' performance on physical work tasks. However, the sleep-restricted group were less physically active throughout the simulation. This may indicate that sleep-restricted participants adapted their behaviour to conserve effort during rest periods, to subsequently ensure they were able to maintain performance during the firefighter work tasks. This work contributes new knowledge to inform fire agencies of firefighters' operational capabilities when their sleep is restricted during multi-day wildfire events. The work also highlights the need for further research to explore how sleep restriction affects physical performance during tasks of varying duration, intensity, and complexity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wildland firefighters often perform their duties under both hot and mild ambient temperatures. However, the direct impact of different ambient temperatures on firefighters' work performance has not been quantified. This study compared firefighters' work performance and physiology during simulated wildland firefighting work in hot (HOT; 32°C, 43% RH) and temperate (CON; 19°C, 56% RH) conditions. Firefighters (n=38), matched and allocated to either the CON (n=18) or HOT (n=20) condition, performed simulated self-paced wildland fire suppression tasks (e.g., hose rolling/dragging, raking) in firefighting clothing for six hours, separated by dedicated rest breaks. Task repetitions were counted (and converted to distance or area). Core temperature (Tc), skin temperature (Tsk), and heart rate were recorded continuously throughout the protocol. Urine output was measured before and during the protocol, and urine specific gravity (USG) analysed, to estimate hydration. Ad libitum fluid intake was also recorded. There were no differences in overall work output between conditions for any physical task. Heart rate was higher in the HOT (55±2% HRmax) compared to the CON condition (51±2% HRmax) for the rest periods between bouts, and for the static hose hold task (69±3% HRmax versus 65±3% HRmax). Tc and Tsk were 0.3±0.1°C and 3.1±0.2°C higher in the HOT compared to the CON trial. Both pre- and within- shift fluid intake were increased two-fold in the heat, and participants in the heat recorded lower USG results than their CON counterparts. There was no difference between the CON and HOT conditions in terms of their work performance, and firefighters in both experimental groups increased their work output over the course of the simulated shift. Though significantly hotter, participants in the heat also managed to avoid excessive cardiovascular and thermal strain, likely aided by the frequent rest breaks in the protocol, and through doubling their fluid intake. Therefore, it can be concluded that wildland firefighters are able to safely and efficiently perform their duties under hot conditions, at least over six hours.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Emergency work can expose personnel to sleep restriction. Inadequate amounts of sleep can negatively affect physiological and psychological stress responses. This review critiqued the emergency service literature (e.g., firefighting, police/law enforcement, defense forces, ambulance/paramedic personnel) that has investigated the effect of sleep restriction on hormonal, inflammatory and psychological responses. Furthermore, it investigated if a psycho-physiological approach can help contextualize the significance of such responses to assist emergency service agencies monitor the health of their personnel. The available literature suggests that sleep restriction across multiple work days can disrupt cytokine and cortisol levels, deteriorate mood and elicit simultaneous physiological and psychological responses. However, research concerning the interaction between such responses is limited and inconclusive. Therefore, it is unknown if a psycho-physiological relationship exists and as a result, it is currently not feasible for agencies to monitor sleep restriction related stress based on psycho- physiological interactions. Sleep restriction does however, appear to be a major stressor contributing to physiological and psychological responses and thus, warrants further investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study assessed the accumulated effect of ambient heat on the performance of, and physiological and perceptual responses to, intermittent, simulated wildfire fighting tasks over three consecutive days. Firefighters (n = 36) were matched and allocated to either the CON (19°C) or HOT (33°C) condition. They performed three days of intermittent, self-paced simulated firefighting work, interspersed with physiological testing. Task repetitions were counted (and converted to distance or area) to determine work performance. Participants were asked to rate their perceived exertion and thermal sensation after each task. Heart rate, core temperature (Tc), and skin temperature (Tsk) were recorded continuously throughout the simulation. Fluids were consumed ad libitum. Urine volume was measured throughout, and urine specific gravity (USG) analysed, to estimate hydration. All food and fluid consumption was recorded. There was no difference in work output between experimental conditions. However, significant variation in performance responses between individuals was observed. All measures of thermal stress were elevated in the HOT, with core and skin temperature reaching, on average, 0.24 ± 0.08°C and 2.81 ± 0.20°C higher than the CON group. Participants' doubled their fluid intake in the HOT condition, and this was reflected in the USG scores, where the HOT participants reported significantly lower values. Heart rate was comparable between conditions at nearly all time points, however the peak heart rate reached each circuit was 7 ± 3% higher in the CON trial. Likewise, RPE was slightly elevated in the CON trial for the majority of tasks. Participants' work output was comparable between the CON and HOT conditions, however the performance change over time varied significantly between individuals. It is likely that the increased fluid replacement in the heat, in concert with frequent rest breaks and task rotation, assisted with the regulation of physiological responses (e.g., heart rate, core temperature).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to examine the associations between firefighters' physical activity levels across consecutive shifts during a multi-day emergency wildfire and to determine whether sleep duration moderated these associations. Forty volunteer firefighters (31 males, 9 females) wore an activity monitor to concurrently measure physical activity and sleep duration. Sedentary time and time spent in light- (LPA), moderate- (MPA), and vigorous-intensity physical activity (VPA) during each shift were determined using monitor-specific cut points. During any given shift, every additional 60 min spent in LPA was associated with 7.2 min more LPA and 27.6 min MPA the following shift. There were no other significant positive or negative associations. No significant moderating effect of total sleep time was observed. Firefighters are able to maintain and/or increase their physical activity intensity between consecutive shifts. Further research is needed to understand firefighters pacing and energy conservation strategies during emergency wildfire deployments. Practitioner Summary To examine associations between firefighters' physical activity levels across consecutive shifts during a multi-day emergency wildfire and determine whether sleep duration moderated these associations. Firefighters are able to maintain and/or increase their physical activity intensity between consecutive shifts. No significant moderating effect of total sleep time was observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The interplay between inflammatory and cortisol responses modulates an appropriate response to a stressor. Exposure to severe stressors, however, may alter the actions and relationships of these responses and contribute to negative health outcomes. Physical work and sleep restriction are two stressors faced by wildland firefighters, yet their influence on the relationship between inflammatory and cortisol responses is unknown. The aim of the present study was to quantify the relationship between the cytokine and cortisol responses to sleep restriction while performing simulated physical wildfire suppression work. Firefighters completed 3 days of simulated physical firefighting work separated by either an 8-h (Control condition; n = 18) or 4-h sleep (Sleep restriction condition; n = 17) opportunity on each of the two nights. Salivary cortisol and inflammatory cytokines (IL-6, IL-8, IL-1β, TNF-α, IL-4, and IL-10) were measured throughout each day. An increase in morning IL-6 was related to a rise (6.2%, P = 0.043) in evening cortisol among firefighters in the sleep restriction condition. Higher morning IL-6 levels were related to increased (5.3%, P = 0.048) daily cortisol levels, but this relationship was not different between conditions. Less pronounced relationships were demonstrated between TNF-α, IL-10, IL-4, and cortisol independent of the sleep opportunity, but relationships did not persist after adjusting for demographic factors and other cytokines. These findings quantify the relationship between cytokine and cortisol responses among wildland firefighters exposed to simulated occupational stressors. Potential disturbances to the IL-6 and cortisol relationship among sleep-restricted firefighters' supports further investigations into the negative health effects related to possible imbalances between these systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study examined firefighters' sleep quantity and quality throughout multi-day wildfire suppression, and assessed the impact of sleep location, shift length, shift start time and incident severity on these variables. For 4 weeks, 40 volunteer firefighters' sleep was assessed using wrist actigraphy. Analyses revealed that the quantity of sleep obtained on fire days was restricted, and pre- and post-sleep fatigue ratings were higher, compared to non-fire days. On fire days, total sleep time was less when: (i) sleep location was in a tent or vehicle, (ii) shifts were greater than 14 h and (iii) shifts started between 05:00 and 06:00 h. This is the first empirical investigation providing objective evidence that firefighters' sleep is restricted during wildfire suppression. Furthermore, sleep location, shift length and shift start time should be targeted when designing appropriate controls to manage fatigue-related risk and preserve firefighters' health and safety during wildfire events. Practitioner Summary: During multi-day wildfire suppression, firefighters' sleep quantity was restricted, and pre- and post-sleep fatigue ratings were higher, compared to non-fire days. Furthermore, total sleep time was less when: (i) sleep occurred in a tent/vehicle, (ii) shifts were >14 h and (iii) shifts started between 05:00 and 06:00 h.