983 resultados para fatigue control
Resumo:
This paper describes the development of an analytical model used to simulate the fatigue behaviour of roof cladding during the passage of a tropical cyclone. The model incorporated into a computer program uses wind pressure data from wind tunnel tests in combination with time history information on wind speed and direction during a tropical cyclone, and experimental fatigue characteristics data of roof claddings. The wind pressure data is analysed using a rainflow form of analysis, and a fatigue damage index calculated using a modified form of Miner's rule. Some of the results obtained to date and their significance in relation to the review of current fatigue tests are presented. The model appears to be reasonable for comparative estimation of fatigue life, but an improvement of Miner's rule is required for the prediction of actual fatigue life.
Resumo:
Purpose Patient-reported symptoms and health-related quality of life (QoL) benefits were investigated in a randomized, phase III trial of afatinib or cisplatin/pemetrexed. Patients and Methods Three hundred forty-five patients with advanced epidermal growth factor receptor (EGFR) mutation-positive lung adenocarcinoma were randomly assigned 2:1 to afatinib 40 mg per day or up to six cycles of cisplatin/pemetrexed. Lung cancer symptoms and health-related QoL were assessed every 21 days until progression using the European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire C30 and Lung Cancer-13 questionnaires. Analyses of cough, dyspnea, and pain were preplanned, including percentage of patients who improved on therapy, time to deterioration of symptoms, and change in symptoms over time. Results Questionnaire compliance was high. Compared with chemotherapy, afatinib significantly delayed the time to deterioration for cough (hazard ratio [HR], 0.60; 95% CI, 0.41 to 0.87; P = .007) and dyspnea (HR, 0.68; 95% CI, 0.50 to 0.93; P = .015), but not pain (HR, 0.83; 95% CI, 0.62 to 1.10; P = .19). More patients on afatinib (64%) versus chemotherapy (50%) experienced improvements in dyspnea scores (P lt; .010). Differences in mean scores over time significantly favored afatinib over chemotherapy for cough (P lt; .001) and dyspnea (P = .001). Afatinib showed significantly better mean scores over time in global health status/QoL (P = .015) and physical (P = .001), role (P = .004), and cognitive (P lt; .007) functioning compared with chemotherapy. Fatigue and nausea were worse with chemotherapy, whereas diarrhea, dysphagia, and sore mouth were worse with afatinib (all P = .01). Conclusion In patients with lung adenocarcinoma with EGFR mutations, first-line afatinib was associated with better control of cough and dyspnea compared with chemotherapy, although diarrhea, dysphagia, and sore mouth were worse. Global health status/QoL was also improved over time with afatinib compared with chemotherapy.
Resumo:
Objective: Individuals with chronic whiplash-associated disorders (WADs) often note driving as a difficult task. This study’s aims were to (1) compare, while driving, neck motor performance, mental effort, and fatigue in individuals with chronic WAD against healthy controls and (2) investigate the relationships of these variables and neck pain to self-reported driving difficulty in the WAD group. Design: This study involved 14 participants in each group (WAD and control). Measures included self-reported driving difficulty and measures of neck pain intensity, overall fatigue, mental effort, and neck motor performance (head rotation and upper trapezius activity) while driving a simulator. Results: The WAD group had greater absolute path of head rotation in a simulated city area and used greater mental effort (P = 0.04), but there were no differences in other measures while driving compared with the controls (all P Q 0.05). Self-reported driving difficulty correlated moderately with neck pain intensity, fatigue level, and maximum velocity of head rotation while driving in the WAD group (all P G 0.05). Conclusions: Individuals with chronic WAD do not seem to have impaired neck motor performance while driving yet use greater mental effort. Neck pain, fatigue, and maximum head rotation velocity could be potential contributors to self-reported driving difficulty in this group.
Resumo:
The aim of the study was to assess the feasibility and effectiveness of aquatic‐based exercise in the form of deep water running ( DWR ) as part of a multimodal physiotherapy programme ( MMPP ) for breast cancer survivors. A controlled clinical trial was conducted in 42 primary breast cancer survivors recruited from community‐based P rimary C are C entres. Patients in the experimental group received a MMPP incorporating DWR , 3 times a week, for an 8‐week period. The control group received a leaflet containing instructions to continue with normal activities. Statistically significant improvements and intergroup effect size were found for the experimental group for P iper F atigue S cale‐ R evised total score ( d = 0.7, P = 0.001), as well as behavioural/severity ( d = 0.6, P = 0.05), affective/meaning ( d = 1.0, P = 0.001) and sensory ( d = 0.3, P = 0.03) domains. Statistically significant differences between the experimental and control groups were also found for general health ( d = 0.5, P < 0.05) and quality of life ( d = 1.3, P < 0.05). All participants attended over 80% of sessions, with no major adverse events reported. The results of this study suggest MMPP incorporating DWR decreases cancer‐related fatigue and improves general health and quality of life in breast cancer survivors. Further, the high level of adherence and lack of adverse events indicate such a programme is safe and feasible.
Resumo:
Purpose: It is relatively common for many mine workers in Australia to drive an average of 250 kilometers to and from work following long shifts and shift blocks. Despite the long distances travelled following long shifts of 12- to 14-hours, there is evidence to suggest that these workers are not engaging in a break following their shift prior to driving home. This naturally raises issues of fatigue and sleepiness when driving. There is limited research in respect to commuting behaviours of mine workers and little is known about the factors that influence these workers to leave site immediately following their shift. Using the theory of planned behaviour, this paper examines individual control beliefs that encourage or prevent workers from leaving the site immediately following their shift block. Method: Data was collected using a cross-sectional survey. The survey instrument was developed following a series of in-depth interviews with workers from a Queensland coal mine (n=37). The quantitative written survey sample (n=461) was drawn from the same coal mine and consisted of workers from all levels of the organisation. Results: The results examine workers intentions to leave the work site and drive home immediately following a shift block. The results show differences in control beliefs between workers finishing night shifts compared with those finishing day shifts. Implications: An understanding of these control beliefs may potentially inform more targeted intervention strategies in the attempt to encourage a safer approach to driving home following shift blocks.
Resumo:
A technique to quantify in real time the microstructural changes occurring during mechanical nanoscale fatigue of ultrathin surface coatings has been developed. Cyclic nanoscale loading, with amplitudes less than 100 nm, is achieved with a mechanical probe miniaturized to fit inside a transmission electron microscope (TEM). The TEM tribological probe can be used for nanofriction and nanofatigue testing, with 3D control of the loading direction and simultaneous TEM imaging of the nano-objects. It is demonstrated that fracture of 10-20 nm thick amorphous carbon films on sharp gold asperities, by a single nanoscale shear impact, results in the formation of < 10 nm diameter amorphous carbon filaments. Failure of the same carbon films after cyclic nanofatigue, however, results in the formation of carbon nanostructures with a significant degree of graphitic ordering, including a carbon onion.
Resumo:
Purpose: To explore the fatigue self-management behaviors and factors associated with effectiveness of these behaviors in patients with advanced cancer. Design: Prospective longitudinal interviewer-administered survey. Setting: A tertiary cancer center in Queensland Australia. Sample: One hundred fifty two outpatients with metastatic breast, lung, colorectal and prostate cancer experiencing fatigue (>3/10) were recruited. Main Research Variables: Fatigue self-management behaviors outcomes (perceived effectiveness, self-efficacy and frequency), medical/demographic characteristics (including sites of primary cancer and metastasis, comorbidity, performance status), social support, depressive, anxiety, and other symptoms were assessed. Findings: The participants reported moderate levels of fatigue at baseline (M=5.85, SD 1.44), and maintained moderate levels at 4 weeks and 8 weeks. On average, participants consistently used approximately nine behaviors at each time point. Factors significantly associated with higher levels of perceived effectiveness of fatigue self-management behaviors were higher self-efficacy (p<.001), higher education level (p=.02), and lower levels of depressive symptoms (p=.04). Conclusions: The findings of this study demonstrate that patients with cancer, even with advanced disease, still want and are able to use a number of behaviors to control their fatigue. Self-management interventions that aim to enhance self-efficacy and address any concurrent depressive symptoms have the potential to reduce fatigue severity. Implications for Nursing: Nurses are well positioned to play a key role in supporting patients in their fatigue self-management. Knowledge Translation: This study particularly focused on the perspectives of patients about fatigue self-management, highlighting a number of issues requiring further attention in clinical practice and the potential for future research.
Resumo:
In-situ transmission electron microscopy (TEM) has developed rapidly over the last decade. In particular, with the inclusion of scanning probes in TEM holders, allows both mechanical and electrical testing to be performed whilst simultaneously imaging the microstructure at high resolution. In-situ TEM nanoindentation and tensile experiments require only an axial displacement perpendicular to the test surface. However, here, through the development of a novel in-situ TEM triboprobe, other surface characterisation experiments are now possible, with the introduction of a fully programmable 3D positioning system. Programmable lateral displacement control allows scratch tests to be performed at high resolution with simultaneous imaging of the changing microstructure. With the addition of repeated cyclic movements, both nanoscale fatigue and friction experiments can also now be performed. We demonstrate a range of movement profiles for a variety of applications, in particular, lateral sliding wear. The developed NanoLAB TEM triboprobe also includes a new closed loop vision control system for intuitive control during positioning and alignment. It includes an automated online calibration to ensure that the fine piezotube is controlled accurately throughout any type of test. Both the 3D programmability and the closed loop vision feedback system are demonstrated here.
Resumo:
Los agrietamientos poligonales representan una forma común de modelado granítico cuyo origen y evolución continúa en fase de estudio, no existiendo una sistematización de estas estructuras diversas. Algunos autores explican su origen por procesos geodinámicos internos, relacionándolo con movimientos de planos de fractura en estados tardíos de consolidación magmática. Otros autores atribuyen su formación y desarrollo a factores externos relacionados con el régimen climático. La gran variedad de agrietamientos poligonales requiere la utilización de un número mayor de variables para definir los distintos orígenes, y las posibles interrelaciones entre los factores externos e internos, así como para explicar la evolución de dichas estructuras y avanzar en la clasificación de los patrones concretos. Este trabajo pretende contribuir a sistematizar los mecanismos que intervienen en el desarrollo de agrietamientos poligonales. Para ello se estudian únicamente agrietamientos poligonales formados sobre planos de fractura verticales o subverticales. En particular se establecen relaciones entre la presencia de agrietamientos poligonales y la red de fracturación, la altura de aparición, la orientación e inclinación de la pared, la morfología de las placas y la profundidad de incisión de las grietas perimetrales. Por otra parte, establece relaciones entre procesos geodinámicos internos y procesos de meteorización externos.
Resumo:
The small-satellite thermal subsystem main function is to control temperature ranges on equipments, and payload for the orbit specified. Structure subsystem has to ensure the satellite structure integrity. Structure integrity should meet two constraints; first constraint is accepted fatigue damage due to cyclic temperature, and second one is tolerable mounting accuracy at payload and Attitude Determination and Control Subsystem (ADCS) equipments’ seats. First, thermal analysis is executed by applying finitedifference method (IDEAS) and temperature profile for satellite components case is evaluated. Then, thermal fatigue analysis is performed applying finite-element analysis (ANSYS) to calculate the resultant damage due to on-orbit cyclic stresses, and structure deformations at the payload and ADCS equipments seats.
Resumo:
The low cycle fatigue (LCF) properties and the fracture behavior of China Low Activation Martensitic (CLAM) steel have been studied over a range of total strain amplitudes from 0.2 to 2.0%. The specimens were cycled using tension-compression loading under total strain amplitude control. The CLAM steel displayed initial hardening followed by continuous softening to failure at room temperature in air. The relationship between strain and fatigue life was predicted using the parameters obtained from fatigue test. The factors effecting on low cycle fatigue of CLAM steel consisted of initial state of matrix dislocation arrangement, magnitude of cyclic stress, magnitude of total strain amplitude and microstructure. The potential mechanisms controlling the stress response, cyclic strain resistance and low cycle fatigue life have been evaluated.
Resumo:
Background - Allotments in the UK are popular and waiting lists long. There is, however, little evidence on the health benefits of allotment gardening. The aims of this study were to determine the impacts of a session of allotment gardening on self-esteem and mood and to compare the mental well-being of allotment gardeners with non-gardeners. Methods - Self-esteem, mood and general health were measured in 136 allotment gardeners pre- and post- an allotment session, and 133 non-gardener controls. Allotment gardeners also detailed the time spent on their allotment in the current session and previous 7 days, and their length of tenure. Results - Paired t-tests revealed a significant improvement in self-esteem (P < 0.05) and mood (P < 0.001) as a result of one allotment session. Linear regression revealed that neither the time spent on the allotment in the current session, the previous 7 days or the length of tenure affected the impacts on self-esteem and mood (P > 0.05). One-way ANCOVA revealed that allotment gardeners had a significantly better self-esteem, total mood disturbance and general health (P < 0.001), experiencing less depression and fatigue and more vigour (P < 0.0083). Conclusions - Allotment gardening can play a key role in promoting mental well-being and could be used as a preventive health measure
Resumo:
This present study aimed to investigate the fatigue life of unused (new) endodontic instruments made of NiTi with control memory by Coltene™ and subjected to the multi curvature of a mandibular first molar root canal. Additionally, the instrument‟s structural behaviour was analysed through non-linear finite element analysis (FEA). The fatigue life of twelve Hyflex™ CM files was assessed while were forced to adopt a stance with multiple radius of curvature, similar to the ones usually found in a mandibular first molar root canal; nine of them were subjected to Pecking motion, a relative movement of axial type. To achieve this, it was designed an experimental setup with the aim of timing the instruments until fracture while worked inside a stainless steel mandibular first molar model with relative axial motion to simulate the pecking motion. Additionally, the model‟s root canal multi-curvature was confirmed by radiography. The non-linear finite element analysis was conducted using the computer aided design software package SolidWorks™ Simulation, in order to define the imposed displacement required by the FEA, it was necessary to model an endodontic instrument with simplified geometry using SolidWorks™ and subsequently analyse the geometry of the root canal CAD model. The experimental results shown that the instruments subjected to pecking motion displayed higher fatigue life values and higher lengths of fractured tips than those with only rotational relative movement. The finite element non-linear analyses shown, for identical conditions, maximum values for the first principal stress lower than the yield strength of the material and those were located in similar positions to the instrument‟s fracture location determined by the experimental testing results.
Resumo:
BACKGROUND: Chronic fatigue syndrome (CFS) is an increasing medical phenomenon of unknown aetiology leading to high levels of chronic morbidity. Of the many hypotheses that purport to explain this disease, immune system activation, as a central feature, has remained prominent but unsubstantiated. Supporting this, a number of important cytokines have previously been shown to be over-expressed in disease subjects. The diagnosis of CFS is highly problematic since no biological markers specific to this disease have been identified. The discovery of genes relating to this condition is an important goal in seeking to correctly categorize and understand this complex syndrome. OBJECTIVE: The aim of this study was to screen for changes in gene expression in the lymphocytes of CFS patients. METHODS: 'Differential Display' is a method for comparing mRNA populations for the induction or suppression of genes. In this technique, mRNA populations from control and test subjects can be 'displayed' by gel electrophoresis and screened for differing banding patterns. These differences are indicative of altered gene expression between samples, and the genes that correspond to these bands can be cloned and identified. Differential display has been used to compare expression levels between four control subjects and seven CFS patients. RESULTS: Twelve short expressed sequence tags have been identified that were over-expressed in lymphocytes from CFS patients. Two of these correspond to cathepsin C and MAIL1 - genes known to be upregulated in activated lymphocytes. The expression level of seven of the differentially displayed sequences have been verified by quantifying relative level of these transcripts using TAQman quantitative PCR. CONCLUSION: Taken as a whole, the identification of novel gene tags up-regulated in CFS patients adds weight to the idea that CFS is a disease characterized by subtle changes in the immune system.