996 resultados para fast blue


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Malachite Green (MG), Crystal Violet (CV) and Brilliant Green (BC) are antibacterial, antifungal and antiparasitic agents that have been used for treatment and prevention of diseases in fish. These dyes are metabolized into reduced leuco forms (LMG, LCV, LBG) that can be present in fish muscles for a long period. Due to the carcinogenic properties they are banned for use in fish for human consumption in many countries including the European Union and the United States. HPLC and LC-MS techniques are generally used for the detection of these compounds and their metabolites in fish. This study presents the development of a fast enzyme-linked immunosorbent assay (ELISA) method as an alternative for screening purposes. A first monoclonal cell line producing antibodies to MG was generated using a hybridoma technique. The antibody had good cross-reactivates with related chromatic forms of triphenylmethane dyes such as CV, BC, Methyl Green, Methyl Violet and Victoria Blue R. The monoclonal antibody (mAb) was used to develop a fast (20 min) disequilibrium ELISA screening method for the detection of triphenylmethanes in fish. By introducing an oxidation step with 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) during sample extraction the assay was also used to detect the presence of the reduced metabolites of triphenylmethanes. The detection capability of the assay was 1 ng g(-1) for MG, LMG, CV, LCV and BC which was below the minimum required performance limit (MRPL) for the detection method of total MG (sum of MG and LMG) set by the Commission Decision 2004/25/EC (2 ng g(-1)). The mean recoveries for fish samples spiked at 0.5 MRPL and MRPL levels with MG and LMG were between 74.9 and 117.0% and inter- and intra-assay coefficients of variation between 4.7 and 25.7%. The validated method allows the analysis of a batch of 20 samples in two to three hours. Additionally, this procedure is substantially faster than other ELISA methods developed for MG/LMG thus far. The stable and efficient monoclonal cell line obtained is an unlimited source of sensitive and specific antibody to MG and other triphenylmethanes. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new photocatalyst indicator ink based on methylene blue (MB) is described that allows the presence and activity of a thin (15 nm) photocatalytic film to be assessed in seconds. The ink is very stable (shelf life > 6 months) and the color change (blue to colorless) striking. The ink utilizes a sacrificial electron donor, glycerol, to trap the photogenerated holes, leaving the photogenerated electrons to react with MB to produce its. reduced, leuco, form (LMB). The efficacy of the MB ink is due to the presence of acid in its formulation, which curtails significantly. the otherwise usual, rapid reoxidation of LMB by ambient O-2.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the TEC4SEA research infrastructure created in Portugal to support research, development, and validation of marine technologies. It is a multidisciplinary open platform, capable of supporting research, development, and test of marine robotics, telecommunications, and sensing technologies for monitoring and operating in the ocean environment. Due to the installed research facilities and its privileged geographic location, it allows fast access to deep sea, and can support multidisciplinary research, enabling full validation and evaluation of technological solutions designed for the ocean environment. It is a vertically integrated infrastructure, in the sense that it possesses a set of skills and resources which range from pure conceptual research to field deployment missions, with strong industrial and logistic capacities in the middle tier of prototype production. TEC4SEA is open to the entire scientific and enterprise community, with a free access policy for researchers affiliated with the research units that ensure its maintenance and sustainability. The paper describes the infrastructure in detail, and discusses associated research programs, providing a strategic vision for deep sea research initiatives, within the context of both the Portuguese National Ocean Strategy and European Strategy frameworks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polymer materials find application in optical storage technology, namely in the development of high information density and fast access type memories. A new polymer blend of methylene blue sensitized polyvinyl alcohol (PVA) and polyacrylic acid (PAA) in methanol is prepared and characterized and its comparison with methylene blue sensitized PVA in methanol and complexed methylene blue sensitized polyvinyl chloride (CMBPVC) is presented. The optical absorption spectra of the thin films of these polymers showed a strong and broad absorption region at 670-650 nm, matching the wavelength of the laser used. A very slow recovery of the dye on irradiation was observed when a 7:3 blend of polyvinyl alcohol/polyacrylic acid at a pHof 3.8 and a sensitizer concentration of 4.67 10 5 g/ml were used. A diffraction efficiency of up to 20% was observed for the MBPVA/alcohol system and an energetic sensitivity of 2000 mJ/cm2 was obtained in the photosensitive films with a spatial frequency of 588 lines/mm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polymer materials find application in optical storage technology, namely in the development of high information density and fast access type memories. A new polymer blend of methylene blue sensitized polyvinyl alcohol (PVA) and polyacrylic acid (PAA) in methanol is prepared and characterized and its comparison with methylene blue sensitized PVA in methanol and complexed methylene blue sensitized polyvinyl chloride (CMBPVC) is presented. The optical absorption spectra of the thin films of these polymers showed a strong and broad absorption region at 670-650 nm, matching the wavelength of the laser used. A very slow recovery of the dye on irradiation was observed when a 7:3 blend of polyvinyl alcohol/polyacrylic acid at a pHof 3.8 and a sensitizer concentration of 4.67 10 5 g/ml were used. A diffraction efficiency of up to 20% was observed for the MBPVA/alcohol system and an energetic sensitivity of 2000 mJ/cm2 was obtained in the photosensitive films with a spatial frequency of 588 lines/mm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, we studied the photocatalytic and the structural aspects of silicon wafers doped with Au and Cu submitted to thermal treatment. The materials were obtained by deposition of metals on Si using the sputtering method followed by fast heating method. The photocatalyst materials were characterized by synchrotron-grazing incidence X-ray fluorescence, ultraviolet-visible spectroscopy, X-ray diffraction, and assays of H(2)O(2) degradation. The doping process decreases the optical band gap of materials and the doping with Au causes structural changes. The best photocatalytic activity was found for thermally treated material doped with Au. Theoretical calculations at density functional theory level are in agreement with the experimental data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, we studied the photocatalytic and the structural aspects of silicon wafers doped with Au and Cu submitted to thermal treatment. The materials were obtained by deposition of metals on Si using the sputtering method followed by fast heating method. The photocatalyst materials were characterized by synchrotron-grazing incidence X-ray fluorescence, ultraviolet-visible spectroscopy, X-ray diffraction, and assays of H(2)O(2) degradation. The doping process decreases the optical band gap of materials and the doping with Au causes structural changes. The best photocatalytic activity was found for thermally treated material doped with Au. Theoretical calculations at density functional theory level are in agreement with the experimental data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple and sensitive method based on a liquid droplet is described for the measurement of atmospheric ozone. A 30 μL drop of indigo blue solution is suspended in a flowing-air sampling stream. The ozone collected reacts with the indigo solution resulting in its decolorization. The colorimetric sensor is composed of two optical fibers and the source of monochromatic light was a red LED (625 nm). The calibration curve was constructed with ozone standard concentrations ranging from 37 - 123 ppbv. The detection limit achieved was 7.3 ppbv. The method considered here showed itself to be easy to apply with a fast response and a total analysis time of only 5 minutes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Blue straggler stars (BSSs) are brighter and bluer (hotter) than the main-sequence (MS) turnoff and they are known to be more massive than MS stars.Two main scenarios for their formation have been proposed:collision-induced stellar mergers (COL-BSSs),or mass-transfer in binary systems (MT-BSSs).Depleted surface abundances of C and O are expected for MT-BSSs,whereas no chemical anomalies are predicted for COL-BSSs.Both MT- and COL-BSSs should rotate fast, but braking mechanisms may intervene with efficiencies and time-scales not well known yet,thus preventing a clear prediction of the expected rotational velocities.Within this context,an extensive survey is ongoing by using the multi-object spectrograph FLAMES@VLT,with the aim to obtain abundance patterns and rotational velocities for representative samples of BSSs in several Galactic GCs.A sub-population of CO-depleted BSSs has been identified in 47 Tuc,with only one fast rotating star detected.For this PhD Thesis work I analyzed FLAMES spectra of more than 130 BSSs in four GCs:M4,NGC 6397,M30 and ω Centauri.This is the largest sample of BSSs spectroscopically investigated so far.Hints of CO depletion have been observed in only 4-5 cases (in M30 and ω Centauri),suggesting either that the majority of BSSs have a collisional origin,or that the CO-depletion is a transient phenomenon.Unfortunately,no conclusions in terms of formation mechanism could be drawn in a large number of cases,because of the effects of radiative levitation. Remarkably,however,this is the first time that evidence of radiative levitation is found in BSSs hotter than 8200 K.Finally, we also discovered the largest fractions of fast rotating BSSs ever observed in any GCs:40% in M4 and 30% in ω Centauri.While not solving the problem of BSS formation,these results provide invaluable information about the BSS physical properties,which is crucial to build realistic models of their evolution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Missense mutations in ATP2A1 gene, encoding SERCA1 protein, cause a muscle disorder designed as congenital pseudomyotonia (PMT) in Chianina and Romagnola cattle or congenital muscular dystonia1 (CMD1) in Belgian Blue cattle. Although PMT is not life-threatening, CMD1 affected calves usually die within a few weeks of age as a result of respiratory complication. We have recently described a muscular disorder in a double muscle Dutch Improved Red and White cross-breed calf. Mutation analysis revealed an ATP2A1 mutation identical to that described in CMD1, even though clinical phenotype was quite similar to that of PMT. Here, we provide evidence for a deficiency of mutated SERCA1 in PMT affected muscles of Dutch Improved Red and White calf, but not of its mRNA. The reduced expression of SERCA1 is selective and not compensated by the SERCA2 isoform. By contrast, pathological muscles are characterized by a broad distribution of mitochondrial markers in all fiber types, not related to intrinsic features of double muscle phenotype and by an increased expression of sarcolemmal calcium extrusion pump. Calcium removal mechanisms, operating in muscle fibers as compensatory response aimed at lowering excessive cytoplasmic calcium concentration caused by SERCA1 deficiency, could explain the difference in severity of clinical signs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

1897 issue contains colonial annual report.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The initial rate of the photocatalysed oxidation of methylene blue, MB, by dissolved oxygen in solution, ri(MB), is measured for a series of titania on glass samples exhibiting a wide range of activities.  The samples used include two different types of commercial self-cleaning glass and a lab-made sol-geltitania film.  The activities of these samples are also assessed using a resazurin-based photocatalyst activity indicator ink, i.e. Rz paii, for which the initial rates of the photocatalysed reduction of Rz were measured, ri(Rz).  A plot of ri(MB)vs. ri(Rz) reveals a goodstraight line, thereby demonstrating a linear correlation (for TiO2films on glass at least) between the slow (usually hours) photocatalysed oxidation of organic materials, such as MB, and the fast (typically minutes) photocatalysed irreversible reduction of a dye, like Rz, in a paii.  The possible use of paii technology for assessing, in a simple, quick and inexpensive manner, photocatalytic films both in the laboratory and in situ is discussed briefly.  

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Blue Streak, named for the Sandusky, Ohio athletic teams, opened in 1964. It was the first new wooden roller coaster at the park since the Cyclone in 1929. A classic out-and-back coaster with a fast and hilly ride, the 78-foot-high Blue Streak is a long time guest favorite. It celebrated its 50th anniversary in 2014.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rapid-screening methods to confirm the presence of resistance mechanisms in multidrug-resistant bacteria are currently recommended. Carba NP and Blue-Carba tests were evaluated in carbapenemase-producing Enterobacteriaceae from hospital (n = 102) and environmental (n = 57) origins for detecting the different molecular classes among them. Both methods showed to be fast and cost-effective, with high sensitivity (98% to 100%) and specificity (100%), and may be easily introduced in the routine laboratory.