997 resultados para experimental errors
Resumo:
The LA-MC-ICP-MS method applied to U-Pb in situ dating is still rapidly evolving due to improvements in both lasers and ICP-MS. To test the validity and reproducibility of the method, 5 different zircon samples, including the standard Temora-2, ranging in age between 2.2 Ga and 246 Ma, were dated using both LA-MC-ICP-MS and SHRIMP. The selected zircons were dated by SHRIMP and, after gentle polishing, the laser spot was driven to the same site or on the same zircon phase with a 213 nm laser microprobe coupled to a multi-collector mixed system. The data were collected with a routine spot size of 25 μm and, in some cases, of 15 and 40 μm. A careful cross-calibration using a diluted U-Th-Pb solution to calculate the Faraday reading to counting rate conversion factors and the highly suitable GJ-1 standard zircon for external calibrations were of paramount importance for obtaining reliable results. All age results were concordant within the experimental errors. The assigned age errors using the LA-MC-ICP-MS technique were, in most cases, higher than those obtained by SHRIMP, but if we are not faced with a high resolution stratigraphy, the laser technique has certain advantages.
Resumo:
Joseph Nicolas Cugnot built the first primitive car in 1769 and approximately one hundred year later the first automotive race took place. Thanks to this, for the first time the aerodynamics principles began to be applied to cars. The aerodynamic study of a car is important to improve the performance on the road, or on the track. It purposely enhances the stability in the turns and increases the maximum velocity. However, it is also useful, decrease the fuel consumption, in order to reduce the pollution. Given that cars are a very complex body, the aerodynamic study cannot be conducted following an analytical method, but it is possible, in general, to choose between two different approaches: the numerical or the experimental one. The results of numerical studies depend on the computers’ potential and on the method use to implement the mathematical model. Today, the best way to perform an aerodynamic study is still experimental, which means that in the first phase of the design process the study is performed in a wind tunnel and in later phases directly on track. The automotive wind tunnels are singular mainly due to the test chamber, which typically contains a ground simulation system. The test chamber can have different types of walls: open walls, closed walls, adaptive walls or slotted walls. The best solution is to use the slotted walls because they minimize the interference between the walls and the streamlines, the interaction between the flow and the environment, and also to contain the overall costs. Furthermore, is necessary minimize the boundary layer at the walls, without accelerating the flow, in order to provide the maximum section of homogeneous flow. This thesis aims at redefining the divergent angle of the Dallara Automobili S.P.A. wind tunnel’s walls, in order to improve the overall homogeneity. To perform this study it was necessary to acquire the pressure data of the boundary layer, than it was created the profile of the boundary layer velocity and, to minimize the experimental errors, it was calculated the displacement thickness. The results obtained shows, even if the instrument used to the experiment was not the best one, that the boundary layer thickness could be minor in case of a low diffusion angle. So it is convenient to perform another experiment with a most sensitive instrument to verified what is the better wall configuration.
Resumo:
Studying liquid fuel combustion is necessary to better design combustion systems. Through more efficient combustors and alternative fuels, it is possible to reduce greenhouse gases and harmful emissions. In particular, coal-derived and Fischer-Tropsch liquid fuels are of interest because, in addition to producing fewer emissions, they have the potential to drastically reduce the United States' dependence on foreign oil. Major academic research institutions like the Pennsylvania State University perform cutting-edge research in many areas of combustion. The Combustion Research Laboratory (CRL) at Bucknell University is striving to develop the necessary equipment to be capable of both independent and collaborative research efforts with Penn State and in the process, advance the CRL to the forefront of combustion studies. The focus of this thesis is to advance the capabilities of the Combustion Research Lab at Bucknell. Specifically, this was accomplished through a revision to a previously designed liquid fuel injector, and through the design and installation of a laser extinction system for the measurement of soot produced during combustion. The previous liquid fuel injector with a 0.005" hole did not behave as expected. Through spray testing the 0.005" injector with water, it was determined that experimental errors were made in the original pressure testing of the injector. Using data from the spray testing experiment, new theoretical hole sizes of the injector were calculated. New injectors with 0.007" and 0.0085" orifices were fabricated and subsequently tested to qualitatively validate their behavior. The injectors were installed in the combustion rig in the CRL and hot-fire tested with liquid heptane. The 0.0085" injector yielded a manageable fuel pressure and produced a broad flame. A laser extinction system was designed and installed in the CRL. This involved the fabrication of a number of custom-designed parts and the specification of laser extinction equipment for purchase. A standard operating procedure for the laser extinction system was developed to provide a consistent, safe method for measuring soot formation during combustion.
Resumo:
Every x-ray attenuation curve inherently contains all the information necessary to extract the complete energy spectrum of a beam. To date, attempts to obtain accurate spectral information from attenuation data have been inadequate.^ This investigation presents a mathematical pair model, grounded in physical reality by the Laplace Transformation, to describe the attenuation of a photon beam and the corresponding bremsstrahlung spectral distribution. In addition the Laplace model has been mathematically extended to include characteristic radiation in a physically meaningful way. A method to determine the fraction of characteristic radiation in any diagnostic x-ray beam was introduced for use with the extended model.^ This work has examined the reconstructive capability of the Laplace pair model for a photon beam range of from 50 kVp to 25 MV, using both theoretical and experimental methods.^ In the diagnostic region, excellent agreement between a wide variety of experimental spectra and those reconstructed with the Laplace model was obtained when the atomic composition of the attenuators was accurately known. The model successfully reproduced a 2 MV spectrum but demonstrated difficulty in accurately reconstructing orthovoltage and 6 MV spectra. The 25 MV spectrum was successfully reconstructed although poor agreement with the spectrum obtained by Levy was found.^ The analysis of errors, performed with diagnostic energy data, demonstrated the relative insensitivity of the model to typical experimental errors and confirmed that the model can be successfully used to theoretically derive accurate spectral information from experimental attenuation data. ^
Resumo:
An analysis of variations in 137Cs and 90Sr concentrations in Baltic Sea surface waters after the accident at the Chernobyl nuclear power plant was performed. Instability of 137Cs concentrations during the short-term observations was found, when they differed 2- to 3-fold. Concentrations of 90Sr appeared to be more stable; meanwhile, their deviations sometimes exceeded ranges of experimental errors. By variations in the monthly average values of radionuclide concentrations in surface waters of the Baltic Sea in 1989-1995, no trend of water self-purification was observed. Theoretical results obtained confirmed a potential of formation and propagation of patches with increased concentrations of 137Cs in the southeastern Baltic Sea. The most reliable factor that controlled the process of self-purification of Baltic Sea water appeared to be the mean annual value of radionuclide concentration. Pronounced divergences were obtained between the measured and calculated mean annual concentrations of 137Cs and 90Sr in surface waters of the Baltic Sea in 1989-2001. These divergences are explained by potential influence of waters from the Gulf of Bothnia and by other additional supplies of radionuclides to marine environment, which were not included into mathematical models.
Resumo:
En esta tesis se recoge el trabajo experimental realizado para la caracterización de las propiedades ópticas en diodos láser construidos con estructuras basadas en pozos cuánticos (QW) y puntos cuánticos (QD). Las propiedades que se han estudiado en estos dispositivos son los espectros de ganancia, ganancia diferencial, índice diferencial y factor de ensanchamiento de línea (LEF). La comprensión de estas propiedades es de especial importancia para el diseño de nuevos diodos láser destinados a ser utilizados en aplicaciones exigentes como son las comunicaciones ópticas o aplicaciones médicas. El estudio se ha llevado a cabo en muestras de diodos láser suministrados por diferentes fabricantes: Ferdinand Braun Institut für Hóchstfrequenztechnik, Thales Research and Technology y la Universidad de Würzburg. Debido a esto las muestras de los láseres se han suministrado en diferentes configuraciones, utilizándose tanto dispositivos con cavidades de área ancha como de tipo caballete (“ridge”). En los trabajos se ha realizado el diseño y la construcción de los montajes experimentales y la implementación de los métodos analíticos necesarios para el estudio de las diferentes muestras. En los montajes experimentales se han implementado procesos para el filtrado espacial de los modos laterales de la cavidad presentes en los láseres de área ancha. Los métodos analíticos implementados se han utilizado para reducir los errores existentes en los sistemas de medida, mejorar su precisión y para separar la variación de índice en debida al calentamiento y la variación de corriente cuando los láseres operan en continua. El estudio sistemático de las propiedades de ópticas de los diodos láser basados en QW y QD ha permitido concluir que propiedades como el factor de ensanchamiento de línea no tienen por qué ser necesariamente inferiores en estos últimos, ya que dependen de las condiciones de inyección. En los láseres de QW se ha observado experimentalmente una reducción del factor de ensanchamiento de línea al alcanzarse la segunda transición, debido al aumento de la ganancia diferencial. ABSTRACT This thesis includes the experimental work for the characterization of optical properties of quantum well (QW) and quantum dot (QD) laser diodes. The properties that have been studied in these devices are the gain, differential gain, differential index and the linewith enhancement factor (LEF). The understating of these properties is of special importance for the design of new laser diodes to be used in exigent applications such as optical communications or medical applications. The study has been carried out using laser samples supplied by different manufacturers: Ferdinand Braun Institut fu¨r H¨ochstfrequenztechnik, Thales Research and Technology and the University of Wu¨rzburg. Because of this the laser samples were supplied in various configurations, using both broad area and ridge devices. In the work it has been done the design and construction of the experimental setups and implementation of analytical methods required for the study of the different devices. In the experimental set-ups it has been implemented a spatial filtering process to remove the lateral modes present in broad area lasers. The implemented analytical methods has been used to reduce the experimental errors in the measurement systems, improve the accuracy and separate the index variation caused by heating and current variation when the lasers operated on continuous wave. The systematic study of the optical properties of the QW and QD laser diodes has allowed concluding that properties such the linewith enhancement factor does not have to be necessary to be lower in the QD devices, since it is dependent on the injections conditions. In this work it has been experimentally observed a reduction of the linewith enhancement factor where the second transition has been reached mainly due to in the increased of the differential gain which is observed in this situation.
Resumo:
Ophthalmophakometric measurements of ocular surface radius of curvature and alignment were evaluated on physical model eyes encompassing a wide range of human ocular dimensions. The results indicated that defocus errors arising from imperfections in the ophthalmophakometer camera telecentricity and light source collimation were smaller than experimental errors. Reasonable estimates emerged for anterior lens surface radius of curvature (accuracy: 0.02–0.10 mm; precision 0.05–0.09 mm), posterior lens surface radius of curvature (accuracy: 0.10–0.55 mm; precision 0.06–0.20 mm), eye rotation (accuracy: 0.00–0.32°; precision 0.06–0.25°), lens tilt (accuracy: 0.00–0.33°; precision 0.05–0.98°) and lens decentration (accuracy: 0.00–0.07 mm; precision 0.00–0.07 mm).
Resumo:
Surface compositional changes in GaAs due to RF plasmas of different gases have been investigated by XPS and etch rates were measured using AFM. Angular Resolved XPS (ARXPS) was also employed for depth analysis of the composition of the surface layers. An important role in this study was determination of oxide thickness using XPS data. The study of surface - plasma interaction was undertaken by correlating results of surface analysis with plasma diagnosis. Different experiments were designed to accurately measure the BEs associated with the Ga 3d, Ga 2P3/2 and LMM peaks using XPS analysis and propose identification in terms of the oxides of GaAs. Along with GaAs wafers, some reference compounds such as metallic Ga and Ga2O3 powder were used. A separate study aiming the identification of the GaAs surface oxides formed on the GaAs surface during and after plasma processing was undertaken. Surface compositional changes after plasma treatment, prior to surface analysis are considered, with particular reference to the oxides formed in the air on the activated surface. Samples exposed to ambient air for different periods of time and also to pure oxygen were analysed. Models of surface processes were proposed for explanation of the stoichiometry changes observed with the inert and reactive plasmas used. In order to help with the understanding of the mechanisms responsible for surface effects during plasma treatment, computer simulation using SRIM code was also undertaken. Based on simulation and experimental results, models of surface phenomena are proposed. Discussion of the experimental and simulated results is made in accordance with current theories and published results of different authors. The experimental errors introduced by impurities and also by data acquisition and processing are also evaluated.
Resumo:
The design and synthesis of biomaterials covers a growing number of biomedical applications. The use of biomaterials in biological environment is associated with a number of problems, the most important of which is biocompatabUity. If the implanted biomaterial is not compatible with the environment, it will be rejected by the biological site. This may be manifested in many ways depending on the environment in which it is used. Adsorption of proteins takes place almost instantaneously when a biomaterial comes into contact with most biological fluids. The eye is a unique body site for the study of protein interactions with biomaterials, because of its ease of access and deceptive complexity of the tears. The use of contact lenses for either vision correction and cosmetic reasons or as a route for the controlled drug delivery, has significantly increased in recent years. It is relatively easy to introduce a contact lens Into the tear fluid and remove after a few minutes without surgery or trauma to the patient. A range of analytical techniques were used and developed to measure the proteins absorbed to some existing commercial contact lens materials and also to novel hydrogels synthesised within the research group. Analysis of the identity and quantity of proteins absorbed to biomaterials revealed the importance of many factors on the absorption process. The effect of biomaterial structure, protein nature in terms of size. shape and charge and pH of the environment on the absorption process were examined in order to determine the relative up-take of tear proteins. This study showed that both lysozyme and lactoferrin penetrate the lens matrix of ionic materials. Measurement of the mobility and activity of the protein deposited into the surface and within the matrix of ionic lens materials demonstrated that the mobility is pH dependent and, within the experimental errors, the biological activity of lysozyme remained unchanged after adsorption and desorption. The study on the effect of different monomers copolymerised with hydroxyethyl methacrylate (HEMA) on the protein up-take showed that monomers producing a positive charge on the copolymer can reduce the spoilation with lysozyme. The studies were extended to real cases in order to compare the patient dependent factors. The in-vivo studies showed that the spoilation is patient dependent as well as other factors. Studies on the extrinsic factors such as dye used in colour lenses showed that the addition of colourant affects protein absorption and, in one case, its effect is beneficial to the wearer as it reduces the quantity of the protein absorbed.
Resumo:
Distributed Brillouin sensing of strain and temperature works by making spatially resolved measurements of the position of the measurand-dependent extremum of the resonance curve associated with the scattering process in the weakly nonlinear regime. Typically, measurements of backscattered Stokes intensity (the dependent variable) are made at a number of predetermined fixed frequencies covering the design measurand range of the apparatus and combined to yield an estimate of the position of the extremum. The measurand can then be found because its relationship to the position of the extremum is assumed known. We present analytical expressions relating the relative error in the extremum position to experimental errors in the dependent variable. This is done for two cases: (i) a simple non-parametric estimate of the mean based on moments and (ii) the case in which a least squares technique is used to fit a Lorentzian to the data. The question of statistical bias in the estimates is discussed and in the second case we go further and present for the first time a general method by which the probability density function (PDF) of errors in the fitted parameters can be obtained in closed form in terms of the PDFs of the errors in the noisy data.
Resumo:
The nature and kinetics of electrode reactions and processes occurring for four lightweight anode systems which have been utilised in reinforced concrete cathodic protection systems have been studied. The anodes investigated were flame sprayed zinc, conductive paint and two activated titanium meshes. The electrochemical properties of each material were investigated in rapidly stirred de-oxygenated electrolytes using anodic potentiodynamic polarisation. Conductive coating electrodes were formed on glass microscope slides, whilst mesh strands were immersed directly. Oxygen evolution occurred preferentially for both mesh anodes in saturated Ca (OH)2/CaC12 solutions but was severely inhibited in less alkaline solutions and significant current only passed in chloride solutions. The main reactions for conductive paint was based on oxygen evolution in all electrolytes, although chlorides increased the electrical activity. Self-corrosion of zinc was controlled by electrolyte composition and the experimental set-up, chlorides increasing the electrical activity. Impressed current cathodic protection was applied to 25 externally exposed concrete slabs over a period of 18 months to investigate anode degradation mechanisms at normal and high current densities. Specimen chloride content, curing and reinforcement depth were also variables. Several destructive and non-destructive methods for assessing the performance of anodes were evaluated including a site instrument for quantitative "instant-off- potential measurements. The impact of cathodic protection on the concrete substrate was determined for a number of specimens using appropriate methods. Anodic degradation rates were primarily influenced by current density, followed by cemendtious alkalinity, chloride levels and by current distribution. Degradation of cementitious overlays and conductive paint substrates proceeded by sequential neutralisation of cement phases, with some evidence of paint binder oxidation. Sprayed zinc progressively formed an insulating layer of hydroxide complexes, which underwent pitting_ attack in the presence of sufficient chlorides, whilst substrate degradation was minimal. Adhesion of all anode systems decreased with increasing current density. The influence of anode material on the ionic gradients which can develop during cathodic protection was investigated. A constant current was passed through saturated cement paste prisms containing calcium chloride to central cathodes via anodes applied or embedded at each end. Pore solution was obtained from successive cut paste slices for anion and cation analyses. Various experimental errors reduced the value of the results. Characteristic S-shaped profiles were not observed and chloride ion profiles were ambiguous. Mesh anode specimens were significantly more durable than the conductive coatings in the high humidity environment. Limited results suggested zinc ion migration to the cathode region. Electrical data from each investigation clearly indicated a decreasing order of anode efficiency by specific anode material.
Resumo:
The aim of this study was to determine whether an ophthalmophakometric technique could offer a feasible means of investigating ocular component contributions to residual astigmatism in human eyes. Current opinion was gathered on the prevalence, magnitude and source of residual astigmatism. It emerged that a comprehensive evaluation of the astigmatic contributions of the eye's internal ocular surfaces and their respective axial separations (effectivity) had not been carried out to date. An ophthalmophakometric technique was developed to measure astigmatism arising from the internal ocular components. Procedures included the measurement of refractive error (infra-red autorefractometry), anterior corneal surface power (computerised video keratography), axial distances (A-scan ultrasonography) and the powers of the posterior corneal surface in addition to both surfaces of the crystalline lens (multi-meridional still flash ophthalmophakometry). Computing schemes were developed to yield the required biometric data. These included (1) calculation of crystalline lens surface powers in the absence of Purkinje images arising from its anterior surface, (2) application of meridional analysis to derive spherocylindrical surface powers from notional powers calculated along four pre-selected meridians, (3) application of astigmatic decomposition and vergence analysis to calculate contributions to residual astigmatism of ocular components with obliquely related cylinder axes, (4) calculation of the effect of random experimental errors on the calculated ocular component data. A complete set of biometric measurements were taken from both eyes of 66 undergraduate students. Effectivity due to corneal thickness made the smallest cylinder power contribution (up to 0.25DC) to residual astigmatism followed by contributions of the anterior chamber depth (up to 0.50DC) and crystalline lens thickness (up to 1.00DC). In each case astigmatic contributions were predominantly direct. More astigmatism arose from the posterior corneal surface (up to 1.00DC) and both crystalline lens surfaces (up to 2.50DC). The astigmatic contributions of the posterior corneal and lens surfaces were found to be predominantly inverse whilst direct astigmatism arose from the anterior lens surface. Very similar results were found for right versus left eyes and males versus females. Repeatability was assessed on 20 individuals. The ophthalmophakometric method was found to be prone to considerable accumulated experimental errors. However, these errors are random in nature so that group averaged data were found to be reasonably repeatable. A further confirmatory study was carried out on 10 individuals which demonstrated that biometric measurements made with and without cycloplegia did not differ significantly.
Resumo:
Distributed Brillouin sensing of strain and temperature works by making spatially resolved measurements of the position of the measurand-dependent extremum of the resonance curve associated with the scattering process in the weakly nonlinear regime. Typically, measurements of backscattered Stokes intensity (the dependent variable) are made at a number of predetermined fixed frequencies covering the design measurand range of the apparatus and combined to yield an estimate of the position of the extremum. The measurand can then be found because its relationship to the position of the extremum is assumed known. We present analytical expressions relating the relative error in the extremum position to experimental errors in the dependent variable. This is done for two cases: (i) a simple non-parametric estimate of the mean based on moments and (ii) the case in which a least squares technique is used to fit a Lorentzian to the data. The question of statistical bias in the estimates is discussed and in the second case we go further and present for the first time a general method by which the probability density function (PDF) of errors in the fitted parameters can be obtained in closed form in terms of the PDFs of the errors in the noisy data.
Resumo:
Ce mémoire s’intéresse à l’étude du critère de validation croisée pour le choix des modèles relatifs aux petits domaines. L’étude est limitée aux modèles de petits domaines au niveau des unités. Le modèle de base des petits domaines est introduit par Battese, Harter et Fuller en 1988. C’est un modèle de régression linéaire mixte avec une ordonnée à l’origine aléatoire. Il se compose d’un certain nombre de paramètres : le paramètre β de la partie fixe, la composante aléatoire et les variances relatives à l’erreur résiduelle. Le modèle de Battese et al. est utilisé pour prédire, lors d’une enquête, la moyenne d’une variable d’intérêt y dans chaque petit domaine en utilisant une variable auxiliaire administrative x connue sur toute la population. La méthode d’estimation consiste à utiliser une distribution normale, pour modéliser la composante résiduelle du modèle. La considération d’une dépendance résiduelle générale, c’est-à-dire autre que la loi normale donne une méthodologie plus flexible. Cette généralisation conduit à une nouvelle classe de modèles échangeables. En effet, la généralisation se situe au niveau de la modélisation de la dépendance résiduelle qui peut être soit normale (c’est le cas du modèle de Battese et al.) ou non-normale. L’objectif est de déterminer les paramètres propres aux petits domaines avec le plus de précision possible. Cet enjeu est lié au choix de la bonne dépendance résiduelle à utiliser dans le modèle. Le critère de validation croisée sera étudié à cet effet.
Resumo:
The main objective of this study was to obtain an effective catalyst for removal of diazo dye - Sudan IV by Catalytic Wet Peroxide Oxidation (CWPO). For this purpose liquid phase treatment was used to increase the basicity of activated carbon surface favoring the adsorption of organic pollutants. Modified activated carbon catalysts were used in different types of experiments: 1) decomposition of H2O2 in aquatic media, 2) decomposition of H2O2 in organic media, 3) adsorption of Sudan IV, 4) Sudan IV removal by CWPO. As the result of all of these experiments the most effective catalyst was obtained and discussed. It was not observed removal of Sudan IV from biphasic system by CWPO. The obtained results in some cases show a slight increase in concentration of Sudan IV, which may be ascribed to experimental errors. Different factors could be the reason of those errors. For example, the high volatility properties of organic media used in experiments should be taken into account during experiments. Under settled reaction temperature the decrease of cyclohexane volume during experiment could give rise in Sudan IV concentration. The initial concentration of model diazo dye also should be reviewed more detailed for CWPO experiments. Despite of these experimental errors the behavior of our catalysts in different media was observed.