998 resultados para elements determination


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Various types of proton-irradiated lead–bismuth eutectic (LBE) samples from the MEGAPIE prototype spallation target were analyzed concerning their content of 148Gd, 173Lu, and 146Pm by use of α- and γ-spectrometry. A radiochemical separation procedure was developed to isolate the lanthanide fraction and to prepare thin samples for α-ray measurement. The results prove a substantial depletion of these three elements in bulk samples, whereas accumulation on the LBE/steel-interfaces was observed. The amount of material accumulated on surfaces was roughly estimated by relating the values measured on the sample surfaces to the total surface of the inner target walls. The amount of 148Gd, 173Lu, and 146Pm was then quantified by summing up the contributions from every sample type. The results show a reasonable agreement with theoretical predictions. The obtained results are of utmost importance for the evaluation of the performance of high-power spallation targets, especially concerning the residual nuclide production, the physicochemical behavior of the produced radionuclides during operation, and in terms of an intermediate or final disposal.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To determine the heavy metal and trace element composition of the powdered aerial parts of Origanum sipyleum L. and its water extract. Methods: The heavy metal and trace elements content of the powdered plant material and 2 % aqueous extract were evaluated by x-ray fluorescence spectroscopy with silicon drift detector SDD at a resolution of 145 eV and 10,000 pulses. The process conditions were 0.1 g sample weight, process time of 300 s at a voltage of 25 kV and 50 kV, and at a current of 0.5 and 1.0 mA under helium atmosphere. Results: The major elements, K, Ca and Na, known as macronutrients, constituted 11990, 10490 and 970 ppm of the powdered drug and 8910, 2991 and 810 ppm of the water extract, respectively. Among other constituents, arsenic, lead and uranium levels were < 1, 2.1 and < 3 ppm, respectively, in the powdered material while in the aqueous extract, the levels were < 1, < 2 and 200 ppm, respectively. Conclusion: O. sipyleum is a potential source of macro- and micronutrients from which useful food additives and health supplements can be derived.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Flavanones (hesperidin, naringenin, naringin, and poncirin) in industrial, hand-squeezed orange juices and from fresh-in-squeeze machines orange juices were determined by HPLC/DAD analysis using a previously described liquid-liquid extraction method. Method validation including the accuracy was performed by using recovery tests. Samples (36) collected from different Brazilian locations and brands were analyzed. Concentrations were determined using an external standard curve. The limits of detection (LOD) and the limits of quantification (LOQ) calculated were 0.0037, 1.87, 0.0147, and 0.0066 mg 100 g(-1) and 0.0089, 7.84, 0.0302, and 0.0200 mg 100 g(-1) for naringin, hesperidin, poncirin, and naringenin, respectively. The results demonstrated that hesperidin was present at the highest concentration levels, especially in the industrial orange juices. Its average content and concentration range were 69.85 and 18.80-139.00 mg 100 g(-1). The other flavanones showed the lowest concentration levels. The average contents and concentration ranges found were 0.019, 0.01-0.30, and 0.12 and 0.1-0.17, 0.13, and 0.01-0.36 mg 100 g(-1), respectively. The results were also evaluated using the principal component analysis (PCA) multivariate analysis technique which showed that poncirin, naringenin, and naringin were the principal elements that contributed to the variability in the sample concentrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

X-ray fluorescence (XRF) is a fast, low-cost, nondestructive, and truly multielement analytical technique. The objectives of this study are to quantify the amount of Na(+) and K(+) in samples of table salt (refined, marine, and light) and to compare three different methodologies of quantification using XRF. A fundamental parameter method revealed difficulties in quantifying accurately lighter elements (Z < 22). A univariate methodology based on peak area calibration is an attractive alternative, even though additional steps of data manipulation might consume some time. Quantifications were performed with good correlations for both Na (r = 0.974) and K (r = 0.992). A partial least-squares (PLS) regression method with five latent variables was very fast. Na(+) quantifications provided calibration errors lower than 16% and a correlation of 0.995. Of great concern was the observation of high Na(+) levels in low-sodium salts. The presented application may be performed in a fast and multielement fashion, in accordance with Green Chemistry specifications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Context. Star activity makes the mass determination of CoRoT-7b and CoRoT 7c uncertain. Investigators of the CoRoT team proposed several solutions, but all but one of them are larger than the initial determinations of 4.8 +/- 0.8 M(Earth) for CoRoT-7b and 8.4 +/- 0.9 M(Earth) for CoRoT 7c. Aims. This investigation uses the excellent HARPS radial velocity measurements of CoRoT-7 to redetermine the planet masses and to explore techniques for determining mass and orbital elements of planets discovered around active stars when the relative variation in the radial velocity due to the star activity cannot be considered as just noise and can exceed the variation due to the planets. Methods. The main technique used here is a self-consistent version of the high-pass filter used by Queloz et al. (2009, A&A, 506, 303) in the first mass determination of CoRoT-7b and CoRoT-7c. The results are compared to those given by two alternative techniques: (1) the approach proposed by Hatzes et al. (2010, A&A, 520, A93) using only those nights in which two or three observations were done; (2) a pure Fourier analysis. In all cases, the eccentricities are taken equal to zero as indicated by the study of the tidal evolution of the system. The periods are also kept fixed at the values given by Queloz et al. Only the observations done in the time interval BJD 2 454 847-873 are used because they include many nights with multiple observations; otherwise, it is not possible to separate the effects of the rotation fourth harmonic (5.91 d = P(rot)/4) from the alias of the orbital period of CoRoT-7b (0.853585 d). Results. The results of the various approaches are combined to give planet mass values 8.0 +/- 1.2 M(Earth) for CoRoT-7b and 13.6 +/- 1.4 M(Earth) for CoRoT 7c. An estimation of the variation of the radial velocity of the star due to its activity is also given. Conclusions. The results obtained with three different approaches agree to give higher masses than those in previous determinations. From the existing internal structure models they indicate that CoRoT-7b is a much denser super-Earth. The bulk density is 11 +/- 3.5 g cm(-3), so CoRoT-7b may be rocky with a large iron core.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes methods for the direct determination of Cd and Pb in hair segments (c.a. 5 mm similar to 80 mu g) by solid sampling graphite furnace atomic absorption spectrometry, becoming possible longitudinal profiles in a single strand of hair. To distinguish endogenous and exogenous content. strands of hair were washed by using two different procedures: IAEA protocol (acetone + water + acetone) and the combination of IAEA protocol with HCl washing (acetone + water + acetone + 0.1 mol l(-1) HCl). The concentration of Cd and Pb increased from the root Until the tip of hair washed according to IAEA protocol. However, when the strand of hair was washed using the combination of IAEA protocol and 0.1 mol l(-1) HCl, Cd concentrations decreased in all segments, and Pb concentrations decreased drastically near to the root (5 to 12 mm) and was systematically higher ill the end. The proposed method showed to be useful to assess the temporal variation to Cd and Pb exposure and call be Used for toxicological and environmental investigations. The limits of detection were 2.8 ng g(-1) for Cd and 40 ng g(-1) for Pb. The characteristic masses based oil integrated absorbance were 2.4 pg for Cd and 22 pg for Pb.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work a simple and reliable method for the simultaneous determination of Cr, Fe, Ni and V in crude oil, using emulsion sampling graphite furnace atomic absorption spectrometry is proposed. Under the best conditions, sample masses around 50 mg were weighed in polypropylene tubes and emulsified in a mixture of 0.5% (v v(-1)) hexane + 6% (m v(-1)) Triton X-100 (R). Considering the compromised conditions, the pyrolysis an atomization temperatures for the simultaneous determination of Cr, Fe, Ni and V were 1400 degrees C and 2500 degrees C, respectively. Aliquots of 20 mu L of reference solution and sample emulsion were co-injected into the graphite tube with 10 mu L of 1.0 g L(-1) Mg(NO(3))(2) as chemical modifier. The detection limits (n = 10, 3 sigma) and characteristic masses were, respectively: 0.07 mu g g(-1) and 19 pg for Cr; 2.15 mu g g(-1) and 31 pg for Fe; 1.25 mu g g(-1) and 44 pg for Ni; and 1.15 mu g g(-1) and 149 pg for V. The reliability of the proposed method was checked by fuel oil Standard Reference Material (SRMTriton X-100 (R) 1634c - NIST) analysis. The concentrations found presented no statistical differences compared to the certified values at 95% confidence level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The performance of laser-induced breakdown spectrometry (LIBS) for the determination of Ba, Cd, Cr and Pb in toys has been evaluated by using a Nd:YAG laser operating at 1064 nm and an Echelle spectrometer with intensified charge-coupled device detector. Samples were purchased in different cities of Sao Paulo State market and analyzed directly without sample preparation. Laser-induced breakdown spectrometry experimental conditions (number of pulses, delay time. integration time gate and pulse energy) were optimized by using a Doehlert design. Laser-induced breakdown spectrometry signals correlated reasonably well with inductively coupled plasma optical emission spectrometry (ICP OES) concentrations after microwave-assisted acid digestion of selected samples. Thermal analysis was used for polymer identification and scanning electron microscopy to Visualize differences in crater geometry of different polymers employed for toy fabrication. Results indicate that laser-induced breakdown spectrometry can be proposed as a rapid screening method for investigation of potentially toxic elements in toys. The unique application of laser-induced breakdown spectrometry for identification of contaminants in successive layers of ink and polymer is also demonstrated. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Laser induced breakdown spectroscopy (LIBS) has been evaluated for the determination of micronutrients (B, Cu, Fe, Mn and Zn) in pellets of plant materials, using NIST, BCR and GBW biological certified reference materials for analytical calibration. Pellets of approximately 2 mm thick and 15 mm diameter were prepared by transferring 0.5 g of powdered material to a 15 mm die set and applying 8.0 tons cm(-2). An experimental setup was designed by using a Nd:YAG laser operating at 1064 nm (200 mJ per pulse, 10 Hz) and an Echelle spectrometer with ICCD detector. Repeatability precision varied from 4 to 30% from measurements obtained in 10 different positions (8 laser shots per test portion) in the same sample pellet. Limits of detection were appropriate for routine analysis of plant materials and were 2.2 mg kg(-1) B, 3.0 mg kg(-1) Cu, 3.6 mg kg(-1) Fe, 1.8 mg kg(-1) Mn and 1.2 mg kg(-1) Zn. Analysis of different plant samples were carried out by LIBS and results were compared with those obtained by ICP OES after wet acid decomposition. (C) 2009 Elsevier B.V. All rights reserved.