136 resultados para electrokinetic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method was developed for injecting a sample on a cross-form microfluidic chip by means of hydrostatic pressure combined with electrokinetic forces. The hydrostatic pressure was generated simply by adjusting the liquid level in different reservoirs without any additional driven equipment such as a pump. Two dispensing strategies using a floating injection and a gated injection, coupled with hydrostatic pressure loading, were tested. The fluorescence observation verified the feasibility of hydrostatic pressure loading in the separation of a mixture of fluorescein sodium salt and fluorescein isothiocyanate. This method was proved to be effective in leading cells to a separation channel for single cell analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the method for the derivatization of carbohydrates with 1-phenyl-3-methyl-5-pyrazolone (PMP) was simplified. One-third of the derivatization time was saved. Five monosaccharide derivatives have been well separated by MEKC and HPLC under optimized conditions. Good reproducibility could be obtained with relative standard deviation (RSD) values of the migration times within 5.0 and 2.3%, respectively. Furthermore, the developed methods have been successfully applied to the analysis of carbohydrates in Aloe powder and food. These methods are quite useful for routine analysis of monosaccharides and oligosaccharides in real samples. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optimization of the organic modifier concentration in micellar electrokinetic capillary chromatography (MECC) has been achieved by a uniform design and iterative optimization method, which has been developed for the optimization of composition of the mobile phase in high performance liquid chromatography. According to the proposed method, the uniform design technique has been applied to design the starting experiments, which can reduce the number of experiments compared with traditional simultaneous methods, such as the orthano design. The hierarchical chromatographic response function has been modified to evaluate the separation quality of a chromatogram in MECC. An iterative procedure has been adopted to search the optimal concentration of organic modifiers for improving the accuracy of retention predicted and the quality of the chromatogram. Validity of the optimization method has been proved by the separation of 31 aromatic compounds in MECC. (C) 2000 John Wiley & Sons, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herein, one water-soluble functionalized ionic liquid (IL), 1-butyl-3-methylimidazolium dodecanesulfonate (BAS), was designed, investigated and successfully applied to microchip micellar electrokinetic chromatography (MEKC) construction. It possessed the properties of both IL and surfactant. A fairly stable pH value similar to 7.4, which was fit to pH values of general biological buffers, was nicely placed at the optimum concentration of 20 mM BAS solution. While applying BAS solution as running buffer in poly(dimethylsiloxane) (PDMS) microfluidic systems, significantly enhanced electroosmotic flow (8-fold) and resolutions between analytes were obtained than that using other supporting electrolytes or surfactants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new approach for fast and sensitive electrochemiluminescence (ECL) detection of narcotic drugs on a microchip after separation by micellar electrokinetic chromatography (MEKC) is presented, taking the cocaine and its hydrolysate ecgonine as the test analytes. The mixture of hydrophilic BMIMBF4 ionic liquid (IL) and sodium dodecyl sulfate (SDS) was used directly as the buffer of MEKC with less noisy baselines, lower electrophoretic current and satisfactory separation performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high performance capillary electrophoresis method with diode array detector detection for the determination of five bioactive ingredients in Tibetan medicine Elsholtzia, namely quercetin, rutin, saussurenoside, kaempferol, and oleanolic acid, has been developed. The effects of several factors, such as the acidity, concentration of running buffer, separation voltage, temperature, and SDS concentration were investigated. The optimal conditions were 44 mmol/L boric acid running buffer (pH 8.5), 45 mmol/L SDS, 16 KV voltage, 20 degrees C, and 10.0% (V/V) of acetonitrile. Under the optimum conditions, five components could be separated with a good baseline resolution within 17 min. The calibration curves showed good linear relationship over the concentration range of 5 x 10(-4)similar to 0.1 mg/mL for quercetin, rutin, saussurenoside, kaempferol, and 1 x 10(-3) similar to 0.1 mg/mL for oleanolic acid. The average recoveries of the method and RSD were ( 99.2%, 3.2%) for quercetin, (102.1%, 2.1%) for rutin, (99.4%, 1.5%) for saussurenoside, (98.9%, 1.8%) for kaempferol, and (99.0%, 2.9%) for oleanolic acid, respectively. The detection limits (S/N = 3) were 1.1 x 10(-4) mg/mL for quercetin, 2.6 x 10(-4) mg/mL for rutin, 1.8 x 10(-4) mg/mL for saussurenoside, 2.9 x 10(-4) mg/mL for kaempferol, and 6.3 x 10(-4) mg/mL for oleanolic acid, respectively. The method was simple, rapid, and reproducible and could be applied for the determination of quercetin, rutin, saussurenoside, kaempferol, and oleanolic acid in Tibetan medicine Elsholtzia, and the assay results were satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Influences of seven organic modifiers, including urea, methanol (MeOH), dioxane (DIO), tetrahydrofuran (THF), acetonitrile (ACN), 1-propanol (1-PrOH) and 2-propanol (2-PrOH), on the solute retention and the electrokinetic migrations in micellar electrokinetic capillary chromatography (MEKC) are investigated with sodium dodecyl sulfate (SDS) micelle as pseudostationary phase. It is observed that in the limited concentration ranges used in the MEKC systems the effect of organic modifier concentration on the retention can be described by the equation logk'=logk'(w)-SC for most binary aqueous-organic buffer, but deviations from this retention equation are observed at ACN and particularly THF as organic modifiers. With parameter S as a measure of the elutropic strength, the elutropic strength of the organic modifiers is found to follow a general order urea