976 resultados para elbow radiography
Resumo:
Objectives. The objectives of this study were to assess the accuracy of working length determination using 3 electronic apex locators and direct digital radiography and to compare the results with those obtained using the visual method (control measurement). Study design. Twenty extracted human maxillary premolars were selected: 17 two-rooted and 3 single-rooted (total of 37 canals). Working length was measured using electronic apex locators Elements Diagnostic, Root ZX, and Just II. Subsequently, teeth were positioned in the alveolar bone of a dry skull and submitted to direct digital radiography. A variation of +/- 1 mm was considered as acceptable. Results were analyzed using the Wilcoxon and the chi(2) tests. Results. Results presented an accuracy of 94.6% for Elements Diagnostic, 91.9% for Root ZX, 73.0% for Just II, and 64.9% for direct digital radiography when considering the margin of +/- 1 mm in relation to the control measurement. Comparisons with the actual control measurements resulted in accuracy results of 13.51%, 13.51%, 10.10%, and 2.70%, respectively. Conclusions. Root ZX and Elements Diagnostic are more accurate in determining working length when compared with Just II and Schick direct digital radiography. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:e44-e49)
Resumo:
Introduction: The aim of this study was to assess the occurrence of apical root transportation after the use of Pro Taper Universal rotary files sizes 3 (F3) and 4 (F4). Methods: Instruments were worked to the apex of the original canal, always by the same operator. Digital subtraction radiography images were produced in buccolingual and mesiodistal projections. A total of 25 radiographs were taken from root canals of human maxillary first molars with curvatures varying from 23-31 degrees. Quantitative data were analyzed by intraclass correlation coefficient and Wilcoxon nonparametric test (P = .05). Results: Buccolingual images revealed a significantly higher degree of apical transportation associated with F4 instruments when compared with F3 instruments in relation to the original canal (Wilcoxon test, P = .007). No significant difference was observed in mesiodistal images (P = .492). Conclusions: F3 instruments should be used with care in curved canals, and F4 instruments should be avoided in apical third preparation of curved canals. (J Endod 2010;36:1052-1055)
Resumo:
Objectives: The diagnosis of caries lesions is still a matter of concern in dentistry. The diagnosis of dental caries by digital radiography has a number of advantages over conventional radiography; however, this method has not been explored fully in the field of paediatric dentistry. This in vitro research evaluated the accuracy of direct digital radiography compared with visual inspection and conventional radiography in the diagnosis of occlusal caries lesions in primary molars. Methods: 50 molars were selected and evaluated under standardized conditions by 2 previously calibrated examiners according to 3 diagnostic methods (visual inspection, conventional radiography and direct digital radiography). Direct digital radiographs were obtained with the Dixi3 system (Planmeca, Helsinki, Finland) and the conventional radiographs with InSight film (Kodak Eastman Co., Rochester, NY). The images were scored and a reference standard was obtained histologically. The interexaminer reliability was calculated using Cohen`s kappa test and the specificity, sensitivity and accuracy of the methods were calculated. Results: Examiner reliability was good. For lesions limited to the enamel, visual inspection showed significantly higher sensitivity and accuracy than both radiographic methods, but no significant difference was found in specificity. For teeth with dentinal caries, no significant differences were found for any parameter when comparing visual and radiographic evaluation. Conclusions: Although less accurate than the visual method for detecting caries lesions confined to the enamel, the direct digital radiographic method is as effective as conventional radiographic examination and visual inspection of primary teeth with occlusal caries when the dentine is involved. Dentomaxillofacial Radiology (2010) 39, 362-367. doi: 10.1259/dmfr/22865872
Resumo:
For the purposes of this report, ""systemic disease"" will be interpreted as conditions that are spread out within the body rather than localized strictly to the tissues of the oral cavity. Since it would take many volumes to review all such conditions, the intent of the authors is to review a few examples of conditions where initial panoramic radiographic findings suggested widespread disease of significance enough to affect the quality of life and longevity of the patient.
Resumo:
A retrospective review of ultrasound guided breast excisional biopsies performed in a Surgical Unit of Princess Alexandra Hospital in 1998-99 was undertaken to assess the use of ultrasound specimen radiography. In this series a total of 55 localization biopsies were performed for impalpable lesions in 53 women. In 21 patients (38%), specimen ultrasound was used to confirm that the lesion in question had been excised, whereas for 34 lesions (62%), specimen X-ray was undertaken. In a total of six cases (10.9% overall) the radiographic abnormality was seen on ultrasound only. Real-time specimen sonography is a technique which is very appropriately utilized in conjunction with ultrasound guided excisions and can be easily performed either in the radiology department or the operative suite With minimal time delay. It could have particular application for lesions that are detected in younger women with dense breast parenchyma. The results of this review confirm specimen sonography to be a reliable technique. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Study design: Single-blind, placebo control, randomized, crossover, experimental Study with repeated measures, Objective: To determine the initial effects of a taping technique on grip strength and pain in individuals with lateral epicondylalgia. Background: Taping techniques are advocated for chronic musculoskeletal conditions such as lateral epicondylalgia, a prevalent disorder with significant impact on the individual and community. Little evidence exists supporting the effects of taping techniques on musculoskeletal pain. Methods and Measures: Sixteen participants (mean age +/- SD, 45.8 +/- 10.2 years) with chronic lateral epicondylalgia (rnean duration +/- SD, 13.1 +/- 9.9 months) participated in a placebo control study of an elbow taping technique. Outcome measures were pain-free grip strength and pressure pain threshold taken before, immediately after, and 30 minutes after application of tape. Results: The taping technique significantly improved pain-free grip strength by 24% from baseline (P = .028). The treatment effect was greater than that for placebo and control conditions. Changes in pressure pain threshold (19%), although positive, were not statistically significant. Conclusion: This preliminary study demonstrated an initial ameliorative effect of a taping technique for lateral epicondylalgia and suggests that it should be considered as an adjunct in the management of this condition.
Resumo:
Previous studies have demonstrated that the initial hypoalgesic effect of spinal manipulative therapy was not antagonized by naloxone and did not exhibit tolerance with repeated applications. The implication is that endogenous opioid mechanisms of pain relief are probably not at play in spinal manipulative therapy. The role of endogenous opioid peptides in manipulation of the peripheral joints has not been investigated. The aim of this study was to evaluate whether the initial hypoalgesic effect of a peripheral manipulative technique (mobilization-with-movement treatment for the elbow) demonstrated a tolerance to repeated applications (ie, reduction in magnitude of effect over repeated applications). Twenty-four participants with unilateral chronic lateral epicondylalgia participated in the study. A repeated measures study was conducted to examine the effect of repeated applications of the mobilization-with-movement treatment for the elbow on 6 separate treatment occasions at least 2 days apart. Pain-free grip strength and pressure pain threshold were chosen as the pain-related outcome measures. Changes in the percent maximum possible effect scores of measures of hypoalgesia were evaluated across the 6 treatment sessions by using linear trend analysis. The results showed no significant difference for the hypoalgesic effect of the treatment technique between sessions (P >.05). This peripheral manipulative therapy treatment technique appeared to have a similar effect profile to previously studied spinal manipulative therapy techniques, thereby contributing to the body of knowledge that indicates that manipulative therapy most likely induces a predominant non-opioid form of analgesia.
Resumo:
During the last two decades screen-film (SF) systems have been replaced by digital X-ray systems. The advent of digital technologies brought a number of digital solutions based on different detector and readout technologies. Improvements in technology allowed the development of new digital technologies for projection radiography such as computed radiography (CR) and digital radiography (DR). The large number of scientific papers concerning digital X-ray systems that have been published over the last 25 years indicates the relevance of these technologies in healthcare. There are important differences among different detector technologies that may affect system performance and image quality for diagnostic purposes. Radiographers are expected to have an effective understanding of digital X-ray technologies and a high level of knowledge and awareness concerning the capabilities of these systems. Patient safety and reliable diagnostic information are intrinsically linked to these factors. In this review article - which is the first of two parts - a global overview of the digital radiography systems (both CR and DR) currently available for clinical practice is provided.
Resumo:
Digital X-ray detector technologies provide several advantages when compared with screen-film (SF) systems: better diagnostic quality of the radiographic image, increased dose efficiency, better dynamic range and possible reduction of radiation exposure to the patient. The transition from traditional SF systems to digital technology-based systems highlights the importance of the discussion around technical factors such as image acquisition, themanagement of patient dose and diagnostic image quality. Radiographers should be aware of these aspects concerning their clinical practice regarding the advantages and limitations of digital detectors. Newdigital technologies require an up-to-date of scientific knowledge concerning their use in projection radiography. This is the second of a two-part review article focused on a technical overview of digital radiography detectors. This article provides a discussion about the issues related to the image acquisition requirements and advantages of digital technologies, the management of patient dose and the diagnostic image quality.
Resumo:
The exposure index (lgM) obtained from a radiographic image may be a useful feedback indicator to the radiographer about the appropriate exposure level in routine clinical practice. This study aims to evaluate lgM in orthopaedic radiography performed in the standard clinical environment. We analysed the lgM of 267 exposures performed with an AGFA CR system. The mean value of lgM in our sample is 2.14. A significant difference (P=0.000<0.05) from 1.96 lgM reference is shown. Data show that 72% of exposures are above the 1.96 lgM and 42% are above the limit of 2.26. Median values of lgM are above 1.96 and below 2.26 for Speed class (SC) 200 (2.16) and SC400 (2.13). The interquartile range is lower in SC400 than in SC200. Data seem to indicate that lgM values are above the manufacturer’s reference of 1.96. Departmental exposure charts should be optimised to reduce the dose given to patients.
Evaluation of exposure parameters in plain radiography: a comparative study with european guidelines
Resumo:
Typical distribution of exposure parameters in plain radiography is unknown in Portugal. This study aims to identify exposure parameters that are being used in plain radiography in the Lisbon area and to compare the collected data with European references [Commission of European Communities (CEC) guidelines]. The results show that in four examinations (skull, chest, lumbar spine and pelvis), there is a strong tendency of using exposure times above the European recommendation. The X-ray tube potential values (in kV) are below the recommended values from CEC guidelines. This study shows that at a local level (Lisbon region), radiographic practice does not comply with CEC guidelines concerning exposure techniques. Further national/local studies are recommended with the objective to improve exposure optimisation and technical procedures in plain radiography. This study also suggests the need to establish national/local diagnostic reference levels and to proceed to effective measurements for exposure optimisation.