937 resultados para distribution transformer life extension


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Watercress (Nasturtium officinale R. Br.) is a semi-aquatic plant of the Brassicaceae family highly appreciated in the Mediterranean cuisine. It features sharp, peppery and slightly tangy taste and contains health-promoting phytochemicals. Its consumption as a fresh-cut product has increased in recent years, as well as the global market of minimally processed vegetables. This demand is driven by the growing interest in the role of food in promoting the human health and wellbeing and to meet consumer needs for fresh-like and more convenient foods. Due to the reduced shelf-life of this plant, the suitability of inert gas-enriched atmospheres and ionizing irradiation for preserving visual, nutritional and functional quality attributes during cold storage was studied. Watercress samples were gathered in the Northeast region of Portugal, rinsed in tap water and a portion was immediately analyzed (non-stored control). The remaining fresh material was packaged in polyethylene bags under N2- and Ar-enriched atmospheres, conventional atmosphere (air) and vacuum (no atmosphere). Samples under conventional atmosphere were irradiated at 1, 2 and 5 kGy of gamma-rays (predicted doses) in a 60Co experimental chamber. A non-irradiated control followed all the experiment. Then, all packaged samples were stored at 4 ºC for 7 days. The studied quality parameters included the colour that was measured with a Konica Minolta colorimeter, and total soluble solids and pH determined in squeezed juice. The proximate composition (moisture, proteins, fat, ash, carbohydrates and energy) was evaluated using the AOA C procedures. Organic acids, free sugars, fatty acids and tocopherols were analyzed by chromatographic techniques. Samples were also evaluated for its DPPH• scavenging activity, reducing power, and lipid peroxidation inhibition capacity trough the inhibition of the β-carotene bleaching and thiobarbituric acid reactive substances (TBAR S) formation. Differences among treatments were analyzed using the one-way analysis of variance (ANO VA) and a linear discriminant analysis (LDA ) was used to evaluate the effects on the overall postharvest quality. After evaluating the effect on the individual quality parameters, the LDA revealed that the Ar-enriched atmosphere and the irradiation at 2 kGy were suitable processing choices for preserving the integrity of the non-stored control samples during cold storage. Thus, these non-thermal treatments were highlighted for shelf-life extension of fresh-cut watercress.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Buckler sorrel (Rumex induratus Boiss. & Reut.) is an underutilized leafy vegetable with peculiar sensory properties and potential as a gourmet food. In the food industry, different packaging methods have been used for shelf-life extension, but it is important to know how the quality of minimally processed vegetable is affected by these treatments. Recently, nitrogen and argon have been used for food packaging. Nitrogen is low soluble in water and other food constituents and does not support the growth of aerobic microbes. In turn, argon is biochemically active and appears to interfere with enzymatic oxygen receptor sites. In this study, modified atmospheres enriched with nitrogen and argon were evaluated for shelf-life extension of buckler sorrel leaves. Wild samples were gathered in Bragança, Portugal, considering local consumers’ sites and criteria. Healthy and undamaged leaves were selected, rinsed in tap water, and a portion was immediately analyzed (non-stored control). The remaining fresh material was packaged in polyethylene bags under nitrogen- and argon-enriched atmospheres and a conventional control atmosphere (air). All packaged samples were stored at 4 ºC for 12 days and then analyzed. The headspace gas composition was monitored during storage. Different quality attributes were evaluated, including visual (colour), nutritional (macronutrients, individual sugars and fatty acids) and bioactive (hydrophilic and lipophilic molecules and antioxidant properties) parameters. Different statistical tools were used; the one-way analysis of variance (ANO VA) was applied for analyse the differences among treatments and a linear discriminant analysis (LDA ) was used to evaluate the effects on the overall postharvest quality. The argon-enriched atmosphere better prevent the samples yellowing. The proximate composition did not change significantly during storage. Samples in control atmosphere revealed higher protein and ash contents and lower levels of lipids. The non-stored control samples presented the higher amounts of fructose, glucose and trehalose. The storage time increased the palmitic acid levels and decreased the content in α-linolenic and linoleic acids. The γ- e δ-tocopherols were higher after the 12 days of cold storage. Probably, the synthesis of these lipophilic compounds was a plant strategy to fight against the abiotic stress induced by storage. Higher levels of total phenolics and flavonoids and increased reducing power and β-carotene bleaching inhibition capacity were also found in the stored control samples. Once again, this result may be attributed to the intrinsic plant-protection mechanisms. Overall, the argon atmosphere was more suitable for quality preservation and shelf-life extension of buckler sorrel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Birnbaum and Saunders (1969a) introduced a probability distribution which is commonly used in reliability studies For the first time based on this distribution the so-called beta-Birnbaum-Saunders distribution is proposed for fatigue life modeling Various properties of the new model including expansions for the moments moment generating function mean deviations density function of the order statistics and their moments are derived We discuss maximum likelihood estimation of the model s parameters The superiority of the new model is illustrated by means of three failure real data sets (C) 2010 Elsevier B V All rights reserved

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A busca no aumento da vida útil dos transformadores de distribuição, redução dos custos de manutenção e mitigação de falhas, leva ao desenvolvimento de novos materiais e critérios de exploração diferenciados desses ativos. Esta pesquisa apresenta o desenvolvimento de um novo transformador de distribuição compacto e mais eficiente utilizando óleo vegetal isolante totalmente biodegradável. Além de biodegradável, o óleo vegetal utilizado possui menor agressividade ambiental e maior capacidade térmica aumentando, a capacidade de carregamento do transformador sem comprometer a sua vida útil. A fim de atestar essa menor agressividade em relação ao óleo mineral, ensaios foram efetuados em um equipamento que permaneceu 12 anos em operação. O equipamento foi totalmente desmontado para análise e coleta de amostras de papel e óleo vegetal isolante. As análises visam comprovar a menor agressividade em relação ao óleo mineral, apresentadas na revisão bibliográfica. A menor agressividade torna possível a proposição de uma nova filosofia de planejamento de redes de distribuição utilizando uma quantidade menor dos novos transformadores para uma mesma carga, tornando-a mais compacta e eficiente.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A breaker restrike is an abnormal arcing phenomenon, leading to a possible breaker failure. Eventually, this failure leads to interruption of the transmission and distribution of the electricity supply system until the breaker is replaced. Before 2008, there was little evidence in the literature of monitoring techniques based on restrike measurement and interpretation produced during switching of capacitor banks and shunt reactor banks in power systems. In 2008 a non-intrusive radiometric restrike measurement method and a restrike hardware detection algorithm were developed by M.S. Ramli and B. Kasztenny. However, the limitations of the radiometric measurement method are a band limited frequency response as well as limitations in amplitude determination. Current restrike detection methods and algorithms require the use of wide bandwidth current transformers and high voltage dividers. A restrike switch model using Alternative Transient Program (ATP) and Wavelet Transforms which support diagnostics are proposed. Restrike phenomena become a new diagnostic process using measurements, ATP and Wavelet Transforms for online interrupter monitoring. This research project investigates the restrike switch model Parameter „A. dielectric voltage gradient related to a normal and slowed case of the contact opening velocity and the escalation voltages, which can be used as a diagnostic tool for a vacuum circuit-breaker (CB) at service voltages between 11 kV and 63 kV. During current interruption of an inductive load at current quenching or chopping, a transient voltage is developed across the contact gap. The dielectric strength of the gap should rise to a point to withstand this transient voltage. If it does not, the gap will flash over, resulting in a restrike. A straight line is fitted through the voltage points at flashover of the contact gap. This is the point at which the gap voltage has reached a value that exceeds the dielectric strength of the gap. This research shows that a change in opening contact velocity of the vacuum CB produces a corresponding change in the slope of the gap escalation voltage envelope. To investigate the diagnostic process, an ATP restrike switch model was modified with contact opening velocity computation for restrike waveform signature analyses along with experimental investigations. This also enhanced a mathematical CB model with the empirical dielectric model for SF6 (sulphur hexa-fluoride) CBs at service voltages above 63 kV and a generalised dielectric curve model for 12 kV CBs. A CB restrike can be predicted if there is a similar type of restrike waveform signatures for measured and simulated waveforms. The restrike switch model applications are used for: computer simulations as virtual experiments, including predicting breaker restrikes; estimating the interrupter remaining life of SF6 puffer CBs; checking system stresses; assessing point-on-wave (POW) operations; and for a restrike detection algorithm development using Wavelet Transforms. A simulated high frequency nozzle current magnitude was applied to an Equation (derived from the literature) which can calculate the life extension of the interrupter of a SF6 high voltage CB. The restrike waveform signatures for a medium and high voltage CB identify its possible failure mechanism such as delayed opening, degraded dielectric strength and improper contact travel. The simulated and measured restrike waveform signatures are analysed using Matlab software for automatic detection. Experimental investigation of a 12 kV vacuum CB diagnostic was carried out for the parameter determination and a passive antenna calibration was also successfully developed with applications for field implementation. The degradation features were also evaluated with a predictive interpretation technique from the experiments, and the subsequent simulation indicates that the drop in voltage related to the slow opening velocity mechanism measurement to give a degree of contact degradation. A predictive interpretation technique is a computer modeling for assessing switching device performance, which allows one to vary a single parameter at a time; this is often difficult to do experimentally because of the variable contact opening velocity. The significance of this thesis outcome is that it is a non-intrusive method developed using measurements, ATP and Wavelet Transforms to predict and interpret a breaker restrike risk. The measurements on high voltage circuit-breakers can identify degradation that can interrupt the distribution and transmission of an electricity supply system. It is hoped that the techniques for the monitoring of restrike phenomena developed by this research will form part of a diagnostic process that will be valuable for detecting breaker stresses relating to the interrupter lifetime. Suggestions for future research, including a field implementation proposal to validate the restrike switch model for ATP system studies and the hot dielectric strength curve model for SF6 CBs, are given in Appendix A.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper addresses the voltage rise constraints that are initiated from increased renewable generation resources in low voltage distribution networks. In this paper, an approach which is able to mitigate these voltage rise constraints and allow for increased distributed generator penetration is presented. The proposed approach involves utilizing the distribution transformers static tap changer to reduce the distribution feeder voltage setpoint. The proposed approach is modeled on a generic low voltage distribution network using the PSS SINCAL© simulation software package and is also implemented in a real low voltage distribution network to verify its practicality. Results indicate that this approach can be implemented to mitigate the voltage rise constraint and increase small-scale embedded generator penetration in a high proportion of low voltage feeders while avoiding any substantial network costs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Low voltage distribution networks feature a high degree of load unbalance and the addition of rooftop photovoltaic is driving further unbalances in the network. Single phase consumers are distributed across the phases but even if the consumer distribution was well balanced when the network was constructed changes will occur over time. Distribution transformer losses are increased by unbalanced loadings. The estimation of transformer losses is a necessary part of the routine upgrading and replacement of transformers and the identification of the phase connections of households allows a precise estimation of the phase loadings and total transformer loss. This paper presents a new technique and preliminary test results for a method of automatically identifying the phase of each customer by correlating voltage information from the utility's transformer system with voltage information from customer smart meters. The techniques are novel as they are purely based upon a time series of electrical voltage measurements taken at the household and at the distribution transformer. Experimental results using a combination of electrical power and current of the real smart meter datasets demonstrate the performance of our techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents simulation results for future electricity grids using an agent-based model developed with MODAM (MODular Agent-based Model). MODAM is introduced and its use demonstrated through four simulations based on a scenario that expects a rise of on-site renewable generators and electric vehicles (EV) usage. The simulations were run over many years, for two areas in Townsville, Australia, capturing variability in space of the technology uptake, and for two charging methods for EV, capturing people's behaviours and their impact on the time of the peak load. Impact analyses of these technologies were performed over the areas, down to the distribution transformer level, where greater variability of their contribution to the assets peak load was observed. The MODAM models can be used for different purposes such as impact of renewables on grid sizing, or on greenhouse gas emissions. The insights gained from using MODAM for technology assessment are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A study undertaken in Hervey Bay, Queensland, investigated the potential of creating an indigenous agribusiness opportunity based on the cultivation of indigenous Australian vegetables and herbs. Included were warrigal greens (WG) (Tetragonia tetragonioides), a green leafy vegetable and the herb sea celery (SC) (Apium prostratum); both traditional foods of the indigenous population and highly desirable to chefs wishing to add a unique, indigenous flavour to modern dishes. Packaging is important for shelf life extension and minimisation of postharvest losses in horticultural products. The ability of two packaging films to extend WG and SC shelf life was investigated. These were Antimisted Biaxial Oriented Polypropylene packaging film (BOPP) without perforations and Antifog BOPP Film with microperforations. Weight loss, packaging headspace composition, colour changes, sensory differences and microbial loads of packed WG and SC leaves were monitored to determine the impact of film oxygen transmission rate (OTR) and film water vapour transmission (WVT) on stored product quality. WG and SC were harvested, sanitised, packed and stored at 4°C for 16 days. Results indicated that the OTR and WVT rates of the package film significantly (PKLEINERDAN0.05) influenced the package headspace and weight loss, but did not affect product colour, total bacteria, yeast and mould populations during storage. There was no significant difference (PGROTERDAN0.05) in aroma, appearance, texture and flavour for WG and SC during storage. It was therefore concluded that a shelf life of 16 days at 4°C, where acceptable sensory properties were retained, was achievable for WG and SC in both packaging films.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tese de doutoramento, Farmácia (Biotecnologia Farmacêutica), Universidade de Lisboa, Faculdade de Farmácia, 2014

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Large-scale renewable energy (RE) integration into the distribution network (DN) causes uncertainties due to its intermittent nature and is a challenging task today. In general RE sources are mostly connected near the end user level, i.e., in the low voltage distribution network. RE integration introduces bi-directional power flows across distribution transformer (DT) and hence DN experiences with several potential problems that includes voltage fluctuations, reactive power compensation and poor power factor in the DN. This study identifies the potential effects causes due to large-scale integration of RE into the Berserker Street Feeder, Frenchville Substation under Rockhampton DN. From the model analyses, it has clearly evident that voltage of the Berserker Street Feeder fluctuates with the increased integration of RE and causes uncertainties in the feeder as well as the DN.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wind energy is one of the most promising renewable energy sources due to its availability and climate-friendly attributes. Large-scale integration of wind energy sources creates potential technical challenges due to the intermittent nature that needs to be investigated and mitigated as part of developing a sustainable power system for the future. Therefore, this study developed simulation models to investigate the potential challenges, in particular voltage fluctuations, zone substation, and distribution transformer loading, power flow characteristics, and harmonic emissions with the integration of wind energy into both the high voltage (HV) and low voltage (LV) distribution network (DN). From model analysis, it has been clearly indicated that influences of these problems increase with the increased integration of wind energy into both the high voltage and low voltage distribution network, however, the level of adverse impacts is higher in the LV DN compared to the HV DN.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The advancement in solar photovoltaic (PV) technology, the cost and efficiency of PVs have encouraged users worldwide to adopt more and more PVs as it is free from greenhouse gas emissions and unlimited in nature. Integration of roof-top solar PV systems is currently emerging rapidly in Australia as the governments are giving attractive incentives and encouraging households to build a sustainable climate-friendly society for the future. The key major barriers to the integration of roof-top solar PV systems are the uncertainties in the performance of the low voltage distribution network due to the intermittent nature of solar PV sources. In this paper, a model was developed to investigate the potential technical impacts of integrating roof-top solar PV systems into the low voltage distribution network in a subtropical climate. The results show that integration of roof-top solar PV in the customer premises causes uncertainties such as voltage fluctuations, phase unbalance, distribution transformer overloading, reactive power compensation, and harmonic injections that detract the overall power quality of the typical distribution network. © 2014 AIP Publishing LLC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose - The purpose of this paper is to present designs for an accelerated life test (ALT). Design/methodology/approach - Bayesian methods and simulation Monte Carlo Markov Chain (MCMC) methods were used. Findings - In the paper a Bayesian method based on MCMC for ALT under EW distribution (for life time) and Arrhenius models (relating the stress variable and parameters) was proposed. The paper can conclude that it is a reasonable alternative to the classical statistical methods since the implementation of the proposed method is simple, not requiring advanced computational understanding and inferences on the parameters can be made easily. By the predictive density of a future observation, a procedure was developed to plan ALT and also to verify if the conformance fraction of the manufactured process reaches some desired level of quality. This procedure is useful for statistical process control in many industrial applications. Research limitations/implications - The results may be applied in a semiconductor manufacturer. Originality/value - The Exponentiated-Weibull-Arrhenius model has never before been used to plan an ALT. © Emerald Group Publishing Limited.