966 resultados para digital dental radiography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION The aim of this study was to determine the reproducibility and accuracy of linear measurements on 2 types of dental models derived from cone-beam computed tomography (CBCT) scans: CBCT images, and Anatomodels (InVivoDental, San Jose, Calif); these were compared with digital models generated from dental impressions (Digimodels; Orthoproof, Nieuwegein, The Netherlands). The Digimodels were used as the reference standard. METHODS The 3 types of digital models were made from 10 subjects. Four examiners repeated 37 linear tooth and arch measurements 10 times. Paired t tests and the intraclass correlation coefficient were performed to determine the reproducibility and accuracy of the measurements. RESULTS The CBCT images showed significantly smaller intraclass correlation coefficient values and larger duplicate measurement errors compared with the corresponding values for Digimodels and Anatomodels. The average difference between measurements on CBCT images and Digimodels ranged from -0.4 to 1.65 mm, with limits of agreement values up to 1.3 mm for crown-width measurements. The average difference between Anatomodels and Digimodels ranged from -0.42 to 0.84 mm with limits of agreement values up to 1.65 mm. CONCLUSIONS Statistically significant differences between measurements on Digimodels and Anatomodels, and between Digimodels and CBCT images, were found. Although the mean differences might be clinically acceptable, the random errors were relatively large compared with corresponding measurements reported in the literature for both Anatomodels and CBCT images, and might be clinically important. Therefore, with the CBCT settings used in this study, measurements made directly on CBCT images and Anatomodels are not as accurate as measurements on Digimodels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To assess the bone mineral density on conventional and digitized images, comparing whether different parameters of digitization and storage change these values. Methods: Twenty radiographs were taken from five partially dentulous dry mandibles with an aluminum 7-mm stepwedge placed on the superior edge of the film. After processing, the films were digitized with a resolution of 600 and 2,400 d.p.i. and saved as TIFF and JPEG files. On every conventional and digitized image, circular regions of interest were selected for densitometry and radiographic contrast analysis. Results: Pearson's correlation coefficient showed a significant and strong mean gray values association between digitized and conventional images, differing from radiographic contrast that did not show a significant association. ANOVA did not reveal a statistically significant difference in bone density and radiographic contrast among the four digitized image groups, but the conventional image contrast was significantly lower. Conclusions: Bone mineral density did not differ in both conventional and digitized images. The parameters of image compression and resolution, tested in this study, did not change the results of densitometry and digitization process increased the radiographic contrast.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: the purpose of this in vivo study was to compare the accuracy of primary incisor length determined by direct digital radiography (straight-line measurement and grid superimposition) and measurement of the actual tooth length. Methods. Twenty-two primary maxillary incisors that required extractions were selected from 3- to 5-year-old children. The teeth were radiographed with an intraoral sensor using the long cone technique and a sensor holder (30-cm focus-to-sensor distance). The exposure time was 03 seconds. Tooth length was estimated by using straight-line and grid measurements provided by the distance measurement feature of the Computed Dental Radiography digital dental imaging system. The actual tooth length was obtained by measuring the extracted tooth with G digital caliper. Data were analyzed statistically by Pearson's correlation coefficient and a paired t test. Results: There were statistically significant differences (P=.007) between the 2 measurement techniques and between the actual tooth lengths and grid measurements. There was no statistically significant difference (P=38) between straight-line measurements and actual tooth lengths, showing that the straight-line measurements were more accurate. Underestimation of the actual tooth length, however, occurred in 45% of the straight-line measurements and in 73% of the grid measurements. Conclusion: It is possible to determine primary tooth length in digital radiographs using onscreen measurements with 0 reasonable degree of accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: This in vitro study evaluated the accuracy of primary incisor lengths determined by digital and conventional radiography compared to the actual tooth length. Methods: Twenty extracted primary maxillary incisors were mounted in acrylic blocks. Tooth length was estimated by using a straight-line measurement provided by the distance measurement tool of a digital dental imaging system (Computed Dental Radiography, Schick Technologies Inc.) and conventional E-speed film radiographs by using a digital caliper. Two operators familiar with both radiographic methods performed the estimates. The estimated tooth lengths were compared to the actual tooth lengths measured with the digital caliper. Data were statistically analyzed by Dahlberg's equation, paired t test, Pearson's correlation coefficient and ANOVA at 5% significance level. Results: There were no statistically significant differences (p = 0.85) between tooth length estimated on digital and conventional radiographs. Admitting as clinically acceptable a 0.5-mm discrepancy between the actual tooth lengths and the radiographically estimated lengths, 60% of the radiographic measurements were considered as accurate. When the acceptable difference range was 1.0 mm, the accuracy of the radiographic measurements increased to 100%. Conclusions: Digital and conventional radiography provided similar tooth length measurements and were equivalent to the actual tooth lengths.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: (1) To evaluate the intraobserver agreement related to image interpretation and (2) to compare the accuracy of 100%, 200% and 400% zoomed digital images in the detection of simulated periodontal bone defects.Methods: Periodontal bone defects were created in 60 pig hemi-mandibles with slow-speed burs 0.5 mm, 1.0 mm, 1.5 mm, 2.0 mm and 3.0 mm in diameter. 180 standardized digital radiographs were made using Schick sensor and evaluated at 100%, 200% and 400% zooming. The intraobserver agreement was estimated by Kappa statistic (kappa). For the evaluation of diagnostic accuracy receiver operating characteristic (ROC) analysis was performed followed by chi-square test to compare the areas under ROC curves according to each level of zooming.Results: For 100%, 200% and 400% zooming the intraobserver agreement was moderate (kappa = 0.48, kappa = 0.54 and kappa = 0.43, respectively) and there were similar performances in the discrimination capacity, with ROC areas of 0.8611 (95% CI: 0.7660-0.9562), 0.8600 (95% CI: 0.7659-0.9540), and 0.8368 (95% CI: 0.7346-0.9390), respectively, with no statistical significant differences (chi(2)-test; P = 0.8440).Conclusions: A moderate intraobserver agreement was observed in the classification of periodontal bone defects and the 100%, 200% and 400% zoomed digital images presented similar performances in the detection of periodontal bone defects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the influence of cyclosporin A (CsA) administration on bone around integrated dental implants assessed by a bone quality index and by quantitative subtraction radiography.A total of 36 machine surface commercial implants were placed in 18 adult rabbits. After a 3-month healing period without any disturbance, the animals were randomly divided into three groups of six animals each. Group A was sacrificed at this time. CsA was injected subcutaneously in an immunosuppressive dose of 10 mg/kg/day in a test group (Group T), and a Group B served as a control, receiving only vehicle. After 3 months of cyclosporin administration, the animals of both Groups B and T were sacrificed. Radiographs were obtained at implant surgery and at the day of sacrifice with a CMOS sensor. Bone quality around the implants was compared between the groups using a bone quality index and quantitative subtraction radiography.The bone analysis showed that in Group T, the bone quality changed dramatically from a dense cortical to a loose trabecular bone structure (P < 0.0001, chi(2) test) while in Groups A and B there were no significant differences. Quantitative digital subtraction radiography showed significantly (P < 0.05) lower gray shade values (radiographic density) in a region of bone formation around the implants in Group T (118 +/- 12) than in Groups A (161 +/- 6) and B (186 +/- 10).Within the limits of this study, CsA administration has a negative effect on the quality of bone around integrated dental implant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the influence of alternative erasing times of DenOptix (R) (Dentsply/Gendex, Chicargo, IL) digital plates oil subjective image quality and the probability of double exposure image not Occurring.Methods: Human teeth were X-rayed with phosphor plates using tell different erasing times. Two observers evaluated the images for subjective Image quality (sharpness, brightness, contrast, enamel definition, dentin definition and dentin-enamal Junction definition) and for the presence or absence of double exposure image. Spearman's correlation analysis and ANOVA was performed to verify the existence ora linear association between the subjective image quality parameters and the alternative erasing times. A contingency table was constructed to evaluate the agreement among the observers, and a binominal logistic regression was performed to verify the correlation between the erasing time and the probability of double exposure image not occurring.Results: All 6 parameters or image quality were rated high by the examiners for the erasing times between 25 s and 130 s. The same erasing time range, from 25 to 130 s, was considered a safe erasing time interval, with no probability of a double exposure image Occurring.Conclusions: The alternative erasing times from 25 s to 130 s showed high quality and no probability of double image Occurrence. Thus, it is possible to reduce the operating time or the DenOptix (R) digital system Without jeopardizing the diagnostic task.Dentomaxillofacial Radiology (2010) 39, 23-27. doi: 10.1259/dmfr/49065239.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Biopatologia Bucal - ICT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Tooth root problems and periodontal diseases are common in South American camelids (SAC). The objective was to evaluate and optimize the imaging technique for dental radiography in SAC and to describe the radiographic and computed tomographic (CT) anatomy of normal teeth at different ages. In this study, the heads of 20 healthy SAC slaughtered for meat production or euthanized for reasons not related to dental problems included 7 female and 10 male llamas and 3 male alpacas. Using a standardized protocol, radiographs and CT scans of the 20 specimen were performed. RESULTS The most useful radiographic projections for mandibular and maxillary cheek teeth evaluation turned out to be lateral30°ventral-laterodorsal and lateral30°dorsal-lateroventral with slight separation of the dental arcades respectively. Digital radiographic and CT appearance of the mandibular and maxillary teeth were described from the beginning of mineralization till maturity. In addition the normal range of the CT radio density of different cheek teeth and different dental tissues were measured. Hounsfield units of different dental tissues of SAC turned out to be similar to equids. Deviation, shortening and partial destruction of the distal tooth root of mandibular 09's and 10's and of maxillary 09's was observed and the existence of a common pulp chamber in younger teeth was revealed. CONCLUSIONS The present study provides information about the dental imaging morphology in clinically healthy SAC. This basic information provides fundamental knowledge for evaluating images and planning treatments in clinically affected animals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A imagem digital no formato DICOM requer grande espaço para armazenamento, dificultando o arquivamento e transmissão da imagem via internet, sendo necessária, muitas vezes, a compressão das imagens por meio de formatos de arquivo como o JPEG. O objetivo neste estudo foi avaliar a influência dos formatos DICOM e JPEG, nos Fatores de Qualidade 100, 80 e 60, na reprodutibilidade intra e interexaminador na marcação de pontos cefalométricos em Telerradiografias digitais em Norma Frontal. A amostra consistiu de 120 imagens digitais de Telerradiografias em Norma Frontal, obtidas de 30 indivíduos. As 30 imagens originais, em formato DICOM, posteriormente, foram convertidas para o formato JPEG, nos Fatores de Qualidade 100, 80 e 60. Após cegar e randomizar a amostra, três ortodontistas calibrados marcaram os 18 pontos cefalométricos em cada imagem utilizando um programa de cefalometria computadorizada, que registra as medidas dos pontos cefalométricos em um sistema de coordenadas cartesianas X e Y. Nos resultados, os testes estatísticos de correlações intraclasses e análise de variância (ANOVA) apresentaram concordância de reprodutibilidade dos pontos cefalométricos em Telerradiografias digitais em Norma Frontal, tanto intra como interexaminador, com exceção dos pontos ZL, ZR, AZ, JR, NC, CN na coordenada Y e A6 na coordenada X, independentemente dos formatos de arquivo. Em conclusão, os formatos de arquivo DICOM e JPEG, nos Fatores de Qualidade 100, 80 e 60, não afetaram a reprodutibilidade intra e interexaminador na marcação dos pontos cefalométricos.(AU)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A imagem digital no formato DICOM requer grande espaço para armazenamento, dificultando o arquivamento e transmissão da imagem via internet, sendo necessária, muitas vezes, a compressão das imagens por meio de formatos de arquivo como o JPEG. O objetivo neste estudo foi avaliar a influência dos formatos DICOM e JPEG, nos Fatores de Qualidade 100, 80 e 60, na reprodutibilidade intra e interexaminador na marcação de pontos cefalométricos em Telerradiografias digitais em Norma Frontal. A amostra consistiu de 120 imagens digitais de Telerradiografias em Norma Frontal, obtidas de 30 indivíduos. As 30 imagens originais, em formato DICOM, posteriormente, foram convertidas para o formato JPEG, nos Fatores de Qualidade 100, 80 e 60. Após cegar e randomizar a amostra, três ortodontistas calibrados marcaram os 18 pontos cefalométricos em cada imagem utilizando um programa de cefalometria computadorizada, que registra as medidas dos pontos cefalométricos em um sistema de coordenadas cartesianas X e Y. Nos resultados, os testes estatísticos de correlações intraclasses e análise de variância (ANOVA) apresentaram concordância de reprodutibilidade dos pontos cefalométricos em Telerradiografias digitais em Norma Frontal, tanto intra como interexaminador, com exceção dos pontos ZL, ZR, AZ, JR, NC, CN na coordenada Y e A6 na coordenada X, independentemente dos formatos de arquivo. Em conclusão, os formatos de arquivo DICOM e JPEG, nos Fatores de Qualidade 100, 80 e 60, não afetaram a reprodutibilidade intra e interexaminador na marcação dos pontos cefalométricos.(AU)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A imagem digital no formato DICOM requer grande espaço para armazenamento, dificultando o arquivamento e transmissão da imagem via internet, sendo necessária, muitas vezes, a compressão das imagens por meio de formatos de arquivo como o JPEG. O objetivo neste estudo foi avaliar a influência dos formatos DICOM e JPEG, nos Fatores de Qualidade 100, 80 e 60, na reprodutibilidade intra e interexaminador na marcação de pontos cefalométricos em Telerradiografias digitais em Norma Frontal. A amostra consistiu de 120 imagens digitais de Telerradiografias em Norma Frontal, obtidas de 30 indivíduos. As 30 imagens originais, em formato DICOM, posteriormente, foram convertidas para o formato JPEG, nos Fatores de Qualidade 100, 80 e 60. Após cegar e randomizar a amostra, três ortodontistas calibrados marcaram os 18 pontos cefalométricos em cada imagem utilizando um programa de cefalometria computadorizada, que registra as medidas dos pontos cefalométricos em um sistema de coordenadas cartesianas X e Y. Nos resultados, os testes estatísticos de correlações intraclasses e análise de variância (ANOVA) apresentaram concordância de reprodutibilidade dos pontos cefalométricos em Telerradiografias digitais em Norma Frontal, tanto intra como interexaminador, com exceção dos pontos ZL, ZR, AZ, JR, NC, CN na coordenada Y e A6 na coordenada X, independentemente dos formatos de arquivo. Em conclusão, os formatos de arquivo DICOM e JPEG, nos Fatores de Qualidade 100, 80 e 60, não afetaram a reprodutibilidade intra e interexaminador na marcação dos pontos cefalométricos.(AU)