958 resultados para delay-line position sensitive detector


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a detailed study of the Baryscan technique, a new efficient alternative to the widespread Z-scan technique which has been demonstrated [Opt. Lett. 36:8, 2011] to reach among the highest sensitivity levels. This method is based upon the measurement of optical nonlinearities by means of beam centroid displacements with a position sensitive detector and is able to deal with any kind of lensing effect. This technique is applied here to measure pump-induced electronic refractive index changes (population lens), which can be discriminated from parasitic thermal effects by using a time-resolved Baryscan experiment. This method is validated by evaluating the polarizability variation at the origin of the population lens observed in the reference Cr3+:GSGG laser material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The AEgIS experiment is an interdisciplinary collaboration between atomic, plasma and particle physicists, with the scientific goal of performing the first precision measurement of the Earth's gravitational acceleration on antimatter. The principle of the experiment is as follows: cold antihydrogen atoms are synthesized in a Penning-Malmberg trap and are Stark accelerated towards a moiré deflectometer, the classical counterpart of an atom interferometer, and annihilate on a position sensitive detector. Crucial to the success of the experiment is an antihydrogen detector that will be used to demonstrate the production of antihydrogen and also to measure the temperature of the anti-atoms and the creation of a beam. The operating requirements for the detector are very challenging: it must operate at close to 4 K inside a 1 T solenoid magnetic field and identify the annihilation of the antihydrogen atoms that are produced during the 1 μs period of antihydrogen production. Our solution—called the FACT detector—is based on a novel multi-layer scintillating fiber tracker with SiPM readout and off the shelf FPGA based readout system. This talk will present the design of the FACT detector and detail the operation of the detector in the context of the AEgIS experiment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel approach based on transmissive phase-modulated fiber Bragg grating (FBG) to implement a virtual delay line interferometer (DLI) is proposed, designed, numerically simulated and fabricated. The resulting devices provide the functionality of a Mach-Zehnder interferometer (MZI), or equivalently a Michelson-Morley interferometer (MMI).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose an optical apparatus enabling the measurement of spherical power, cylindrical power, and optical center coordinates of ophthalmic lenses. The main advantage of this new focimeter is to provide a full bidimensional mapping of the characteristics of ophthalmic glasses. This is made possible thanks to the use of a large-area and high-resolution position-sensitive detector. We describe the measurement principle and present some typical mappings, particularly for progressive lenses. We then discuss the advantages in terms of speed and versatility of such a focimeter for the measurement of complex lens mappings. (C) 2002 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method using two prisms for measurement of small dynamic angles is proposed in which the measurement is based on a simple tangent equation and a phase-modulating interferometer with a laser diode to measure dynamic optical path differences with higher accuracy. Owing to the simple tangent equation, the symmetry requirement on the two prisms in the optical configuration is eliminated, and easy measurement of the separations between two parallel beams with a position-sensitive detector is achieved. Small-dynamic-angle measurements are experimentally demonstrated with high accuracy. (C) 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

提出一种基于平行平板干涉仪的改进型角度测量方法。为了实现较大的偏转角度测量,该平行平板干涉仪引入了一位置探测系统。平面反射镜的引入提高了角度测量的分辨率。实验验证了可在近3度的范围内实现被测偏转角度的高精度测量。并且作为一位相调制型干涉仪,其小角位移测量实验的重复精度可达5.5×10^(-8)rad。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method using two prisms for measurement of small dynamic angles is proposed in which the measurement is based on a simple tangent equation and a phase-modulating interferometer with a laser diode to measure dynamic optical path differences with higher accuracy. Owing to the simple tangent equation, the symmetry requirement on the two prisms in the optical configuration is eliminated, and easy measurement of the separations between two parallel beams with a position-sensitive detector is achieved. Small-dynamic-angle measurements are experimentally demonstrated with high accuracy. (C) 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A parallel plate interferometer with a reflecting mirror for measuring angular displacement is proposed. A deflection angle of a beam caused by an angular displacement is amplified by use of a reflecting mirror to increase the optical path difference (OPD) in the plane-parallel plate, which provides high sensitivity of the phase measurement. Detection of light transmitted through the plane-parallel plate with a position sensitive detector (PSD) enables high accurate measurement of the initial angle of incidence to the plane-parallel plate with insensitivity to stray light. The improved parallel plate interferometer achieves a measurement repeatability of 10(-8) rad. (C) 2007 The Optical Society of Japan.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

在一种已有的角位移干涉测量技术的基础上,提出一种改进的角位移测量方法。通过选择合适的初始入射角,使从平板前后表面反射的两光束实现剪切干涉。采用一维位置探测器测量光束经透镜会聚后在探测器光敏面上的光点偏移量。根据干涉信号的相位和光点偏移量可以计算出被测物体的角位移。在该测量方案中,引入的一平面反射镜与被测物体的反射面形成光程差放大系统,提高了角位移测量灵敏度。分析了初始入射角对剪切比的影响,并讨论了基于该方案的角位移测量精度。实验结果表明,基于该技术的角位移重复测量精度达到10-8 rad数量级。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the experiment of nuclear reaction, it is important to measure the mass, charge, energy and emitted direction of particles. For multiparameter measurement, we must use a detector or a group of detectors which can give the time, energy, and position information. The Large Area position sensitive Ionization Chamber(LAIC) is one of the eight experiment terminals of HIRFL. It is built for researching nuclear reactions from low energy to intermediate energy. It is an excellent equipment for energy measurements and atomic number identification of emitted fragments in this energy region. It is also designed to give the time and position information of the emitted fragments by itself. Obviously, an IC can not supply a good timing signal. Moreover, the mechanical installation is different from the original design by some other reasons. In this case, it is not enough to obtain the correct direction information of the emitted fragments. To obtain good timing signals and the correct direction information, some modifications must be made. It is well known that a PPAC can give us excellent timing signals. It also can be easily built as a position sensitive detector. For this reason, a specially designed PPAC is installed in the entrance of the LAIC. For the different purposes, two types of PPACs were designed and tested. Both are OCTPSACs (OCTunit one dimension Position Sensitive Avalanche Counter). In this paper, both OCTPSACs will be introduced. Based on the requirements of the LAIC, the OCTPSACs consist of eight position sensitive PPACs. Each PPAC has an anode and a cathode. In both cases, the sizes are same. But different type of cathodes are used. In one type of OCTPSAC, its cathode is made of wire plane. It consists of gold-plated tungsten wires with the diameter of 20μm, spaced 0.5 mm apart from each other. The anode is a mylar foil which was evaporated by gold layer with the thickness of 50μg/cm~2 mounted on a printed plate in the shape of rectangle. the thickness of mylar foil is 1.5μm. The gap between anode and cathode is 3mm. The performance of the OCTPSAC has been tested by using a ~(252)Cf source in flowing isobutylene gas at the pressure of 3.4mb. The intrinsic time resolution of 289ps and position resolution of 2 mm have been obtained. In another type of OCTPSAC, the cathode is made of mylar foil, which is composed of gold strip by vacuume evaporation method with a special mask on the mylar foil. The thickness and the width of the gold strip is 50μg/cm~2 and 1.7mm. The strips are spaced 0.3 mm apart from each other. The anode is the same as the former type. We have obtained the time resolution of 296ps and position resolution of 2mm by using ~(241)Am-a source when the gas pressure is 6 mb and high voltage is 600V. The working gas is heptane

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PSD是一种高分辨率、实时性好的光电位置敏感器件,因而具有广泛应用的前景.但在光照度变化条件下,输出信号存在非线性飘移,因而影响了作为位置检测传感器的检测精度,尤其在3D测量时适用性受到了限制.针对这个问题,提出了一种PSD位置传感器的非线性误差补偿方法.该方法针对目标的空间距离变化所产生的PSD输出非线性飘移,采用归一化模型进行误差修正,很大程度上改进了PSD的输出一致性,使基于PSD的3D测量系统性能得以提高.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Photothermal effect refers to heating of a sample due to the absorption of electromagnetic radiation. Photothermal (PT) heat generation which is an example of energy conversion has in general three kinds of applications. 1. PT material probing 2. PT material processing and 3. PT material destruction. The temperatures involved increases from 1-. 3. Of the above three, PT material probing is the most important in making significant contribution to the field of science and technology. Photothermal material characterization relies on high sensitivity detection techniques to monitor the effects caused by PT material heating of a sample. Photothermal method is a powerful high sensitivity non-contact tool used for non-destructive thermal characterization of materials. The high sensitivity of the photothermal methods has led to its application for analysis of low absorbance samples. Laser calorimetry, photothermal radiometry, pyroelectric technique, photoacoustic technique, photothermal beam deflection technique, etc. come under the broad class ofphotothermal techniques. However the choice of a suitable technique depends upon the nature of the sample, purpose of measurement, nature of light source used, etc. The present investigations are done on polymer thin films employing photothermal beam deflection technique, for the successful determination of their thermal diffusivity. Here the sample is excited by a He-Ne laser (A = 6328...\ ) which acts as the pump beam. Due to the refractive index gradient established in the sample surface and in the adjacent coupling medium, another optical beam called probe beam (diode laser, A= 6500A ) when passed through this region experiences a deflection and is detected using a position sensitive detector and its output is fed to a lock-in amplifier from which the amplitude and phase of the deflection can be directly obtained. The amplitude and phase of the signal is suitably analysed for determining the thermal diffusivity.The production of polymer thin film samples has gained considerable attention for the past few years. Plasma polymerization is an inexpensive tool for fabricating organic thin films. It refers to formation of polymeric materials under the influence of plasma, which is generated by some kind of electric discharge. Here plasma of the monomer vapour is generated by employing radio frequency (MHz) techniques. Plasma polymerization technique results in homogeneous, highly adhesive, thermally stable, pinhole free, dielectric, highly branched and cross-linked polymer films. The possible linkage in the formation of the polymers is suggested by comparing the FTIR spectra of the monomer and the polymer.Near IR overtone investigations on some organic molecules using local mode model are also done. Higher vibrational overtones often provide spectral simplification and greater resolution of peaks corresponding to nonequivalent X-H bonds where X is typically C, N or O. Vibrational overtone spectroscopy of molecules containing X-H oscillators is now a well established tool for molecular investigations. Conformational and steric differences between bonds and structural inequivalence ofCH bonds (methyl, aryl, acetylenic, etc.) are resolvable in the higher overtone spectra. The local mode model in which the X-H oscillators are considered to be loosely coupled anharmonic oscillators has been widely used for the interpretation of overtone spectra. If we are exciting a single local oscillator from the vibrational ground state to the vibrational state v, then the transition energy of the local mode overtone is given by .:lE a......v = A v + B v2 • A plot of .:lE / v versus v will yield A, the local mode frequency as the intercept and B, the local mode diagonal anharmonicity as the slope. Here A - B gives the mechanical frequency XI of the oscillator and B = X2 is the anharmonicity of the bond. The local mode parameters XI and X2 vary for non-equivalent X-H bonds and are sensitive to the inter and intra molecular environment of the X-H oscillator.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Material synthesizing and characterization has been one of the major areas of scientific research for the past few decades. Various techniques have been suggested for the preparation and characterization of thin films and bulk samples according to the industrial and scientific applications. Material characterization implies the determination of the electrical, magnetic, optical or thermal properties of the material under study. Though it is possible to study all these properties of a material, we concentrate on the thermal and optical properties of certain polymers. The thermal properties are detennined using photothermal beam deflection technique and the optical properties are obtained from various spectroscopic analyses. In addition, thermal properties of a class of semiconducting compounds, copper delafossites, arc determined by photoacoustic technique.Photothermal technique is one of the most powerful tools for non-destructive characterization of materials. This forms a broad class of technique, which includes laser calorimetry, pyroelectric technique, photoacollstics, photothermal radiometric technique, photothermal beam deflection technique etc. However, the choice of a suitable technique depends upon the nature of sample and its environment, purpose of measurement, nature of light source used etc. The polynler samples under the present investigation are thermally thin and optically transparent at the excitation (pump beam) wavelength. Photothermal beam deflection technique is advantageous in that it can be used for the detennination of thermal diffusivity of samples irrespective of them being thermally thick or thennally thin and optically opaque or optically transparent. Hence of all the abovementioned techniques, photothemlal beam deflection technique is employed for the successful determination of thermal diffusivity of these polymer samples. However, the semi conducting samples studied are themlally thick and optically opaque and therefore, a much simpler photoacoustic technique is used for the thermal characterization.The production of polymer thin film samples has gained considerable attention for the past few years. Different techniques like plasma polymerization, electron bombardment, ultra violet irradiation and thermal evaporation can be used for the preparation of polymer thin films from their respective monomers. Among these, plasma polymerization or glow discharge polymerization has been widely lIsed for polymer thin fi Im preparation. At the earlier stages of the discovery, the plasma polymerization technique was not treated as a standard method for preparation of polymers. This method gained importance only when they were used to make special coatings on metals and began to be recognized as a technique for synthesizing polymers. Thc well-recognized concept of conventional polymerization is based on molecular processcs by which thc size of the molecule increases and rearrangemcnt of atoms within a molecule seldom occurs. However, polymer formation in plasma is recognized as an atomic process in contrast to the above molecular process. These films are pinhole free, highly branched and cross linked, heat resistant, exceptionally dielectric etc. The optical properties like the direct and indirect bandgaps, refractive indices etc of certain plasma polymerized thin films prepared are determined from the UV -VIS-NIR absorption and transmission spectra. The possible linkage in the formation of the polymers is suggested by comparing the FTIR spectra of the monomer and the polymer. The thermal diffusivity has been measured using the photothermal beam deflection technique as stated earlier. This technique measures the refractive index gradient established in the sample surface and in the adjacent coupling medium, by passing another optical beam (probe beam) through this region and hence the name probe beam deflection. The deflection is detected using a position sensitive detector and its output is fed to a lock-in-amplifIer from which the amplitude and phase of the deflection can be directly obtained. The amplitude and phase of the deflection signal is suitably analyzed for determining the thermal diffusivity.Another class of compounds under the present investigation is copper delafossites. These samples in the form of pellets are thermally thick and optically opaque. Thermal diffusivity of such semiconductors is investigated using the photoacoustic technique, which measures the pressure change using an elcctret microphone. The output of the microphone is fed to a lock-in-amplificr to obtain the amplitude and phase from which the thermal properties are obtained. The variation in thermal diffusivity with composition is studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Photothermal deflection technique was used for determining the laser damage threshold of polymer samples of teflon (PTFE) and nylon. The experiment was conducted using a Q-switched Nd-YAG laser operating at its fundamental wavelength (1-06μm, pulse width 10 nS FWHM) as irradiation source and a He-Ne laser as the probe beam, along with a position sensitive detector. The damage threshold values determined by photothermal deflection method were in good agreement with those determined by other methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Antihydrogen Experiment: Gravity, Interferometry, Spectroscopy (AEgIS) experiment is conducted by an international collaboration based at CERN whose aim is to perform the first direct measurement of the gravitational acceleration of antihydrogen in the local field of the Earth, with Δg/g = 1% precision as a first achievement. The idea is to produce cold (100 mK) antihydrogen ( ¯H) through a pulsed charge exchange reaction by overlapping clouds of antiprotons, from the Antiproton Decelerator (AD) and positronium atoms inside a Penning trap. The antihydrogen has to be produced in an excited Rydberg state to be subsequently accelerated to form a beam. The deflection of the antihydrogen beam can then be measured by using a moir´e deflectometer coupled to a position sensitive detector to register the impact point of the anti-atoms through the vertex reconstruction of their annihilation products. After being approved in late 2008, AEgIS started taking data in a commissioning phase in 2012. This paper presents an outline of the experiment with a brief overview of its physics motivation and of the state-of-the-art of the g measurement on antimatter. Particular attention is given to the current status of the emulsion-based position detector needed to measure the ¯H sag in AEgIS.