999 resultados para ddc: 620.104
Resumo:
Background: There are several numerical investigations on bone remodelling after total hip arthroplasty (THA) on the basis of the finite element analysis (FEA). For such computations certain boundary conditions have to be defined. The authors chose a maximum of three static load situations, usually taken from the gait cycle because this is the most frequent dynamic activity of a patient after THA. Materials and methods: The numerical study presented here investigates whether it is useful to consider only one static load situation of the gait cycle in the FE calculation of the bone remodelling. For this purpose, 5 different loading cases were examined in order to determine their influence on the change in the physiological load distribution within the femur and on the resulting strain-adaptive bone remodelling. First, four different static loading cases at 25%, 45%, 65% and 85% of the gait cycle, respectively, and then the whole gait cycle in a loading regime were examined in order to regard all the different loadings of the cycle in the simulation. Results: The computed evolution of the apparent bone density (ABD) and the calculated mass losses in the periprosthetic femur show that the simulation results are highly dependent on the chosen boundary conditions. Conclusion: These numerical investigations prove that a static load situation is insufficient for representing the whole gait cycle. This causes severe deviations in the FE calculation of the bone remodelling. However, accompanying clinical examinations are necessary to calibrate the bone adaptation law and thus to validate the FE calculations.
Resumo:
Background: Ceramic materials are used in a growing proportion of hip joint prostheses due to their wear resistance and biocompatibility properties. However, ceramics have not been applied successfully in total knee joint endoprostheses to date. One reason for this is that with strict surface quality requirements, there are significant challenges with regard to machining. High-toughness bioceramics can only be machined by grinding and polishing processes. The aim of this study was to develop an automated process chain for the manufacturing of an all-ceramic knee implant. Methods: A five-axis machining process was developed for all-ceramic implant components. These components were used in an investigation of the influence of surface conformity on wear behavior under simplified knee joint motion. Results: The implant components showed considerably reduced wear compared to conventional material combinations. Contact area resulting from a variety of component surface shapes, with a variety of levels of surface conformity, greatly influenced wear rate. Conclusions: It is possible to realize an all-ceramic knee endoprosthesis device, with a precise and affordable manufacturing process. The shape accuracy of the component surfaces, as specified by the design and achieved during the manufacturing process, has a substantial influence on the wear behavior of the prosthesis. This result, if corroborated by results with a greater sample size, is likely to influence the design parameters of such devices.
Resumo:
The need for high temporal and spatial resolution precipitation data for hydrological analyses has been discussed in several studies. Although rain gauges provide valuable information, a very dense rain gauge network is costly. As a result, several new ideas have been emerged to help estimating areal rainfall with higher temporal and spatial resolution. Rabiei et al. (2013) observed that moving cars, called RainCars (RCs), can potentially be a new source of data for measuring rainfall amounts. The optical sensors used in that study are designed for operating the windscreen wipers and showed promising results for rainfall measurement purposes. Their measurement accuracy has been quantified in laboratory experiments. Considering explicitly those errors, the main objective of this study is to investigate the benefit of using RCs for estimating areal rainfall. For that, computer experiments are carried out, where radar rainfall is considered as the reference and the other sources of data, i.e. RCs and rain gauges, are extracted from radar data. Comparing the quality of areal rainfall estimation by RCs with rain gauges and reference data helps to investigate the benefit of the RCs. The value of this additional source of data is not only assessed for areal rainfall estimation performance, but also for use in hydrological modeling. The results show that the RCs considering measurement errors derived from laboratory experiments provide useful additional information for areal rainfall estimation as well as for hydrological modeling. Even assuming higher uncertainties for RCs as obtained from the laboratory up to a certain level is observed practical.
Resumo:
This report investigates adaptations of electronic packaging methods used to create stacks of these sensors. Four methods were developed and tested to determine the best option in terms of mechanical stability and electrical conductivity of the system. For the first method, a stack is created by way of through paper vias (TPVs), a hole that is cut in the pads of the sensors and then filled with electrically conductive adhesive through the openings on the two sensors to be joined. The second method is called mechanical caulking and connects sensors through pads which have been lined with copper tape backed with conductive adhesive. The connection is created with a small copper rivet which is flattened in place by compressive force. The third method is the stitching method which is inspired by sewing of fabric. A pattern of thin copper wire is stitched on the pad of a sensor that is lined with copper tape backed with conductive adhesive. The wire is then stitched through a second sensor that is treated similarly with copper tape and the stack receives the same pattern through the two layers as was applied to the first sensor alone. The final method is the collapsed daisy chain which is the linear connection of sensors to their neighboring sensors via copper tape backed with conductive adhesive. The row of sensors is then collapsed in an alternating orientation into a single stack.
Resumo:
The accurate prediction of stress histories for the fatigue analysis is of utmost importance for the design process of wind turbine rotor blades. As detailed, transient, and geometrically non-linear three-dimensional finite element analyses are computationally weigh too expensive, it is commonly regarded sufficient to calculate the stresses with a geometrically linear analysis and superimpose different stress states in order to obtain the complete stress histories. In order to quantify the error from geometrically linear simulations for the calculation of stress histories and to verify the practical applicability of the superposition principal in fatigue analyses, this paper studies the influence of geometric non-linearity in the example of a trailing edge bond line, as this subcomponent suffers from high strains in span-wise direction. The blade under consideration is that of the IWES IWT-7.5-164 reference wind turbine. From turbine simulations the highest edgewise loading scenario from the fatigue load cases is used as the reference. A 3D finite element model of the blade is created and the bond line fatigue assessment is performed according to the GL certification guidelines in its 2010 edition, and in comparison to the latest DNV GL standard from end of 2015. The results show a significant difference between the geometrically linear and non-linear stress analyses when the bending moments are approximated via a corresponding external loading, especially in case of the 2010 GL certification guidelines. This finding emphasizes the demand to reconsider the application of the superposition principal in fatigue analyses of modern flexible rotor blades, where geometrical nonlinearities become significant. In addition, a new load application methodology is introduced that reduces the geometrically non-linear behaviour of the blade in the finite element analysis.
Resumo:
Reports of long-term tenofovir disoproxil fumarate (TDF) treatment in HIV-infected adolescents are limited. We present final results from the open-label (OL) TDF extension following the randomized, placebo (PBO)-controlled, double-blind phase of GS-US-104-0321 (Study 321). HIV-infected 12- to 17-year-olds treated with TDF 300 mg or PBO with an optimized background regimen (OBR) for 24-48 weeks subsequently received OL TDF plus OBR in a single arm study extension. HIV-1 RNA and safety, including bone mineral density (BMD), was assessed in all TDF recipients. Eighty-one subjects received TDF (median duration 96 weeks). No subject died or discontinued OL TDF for safety/tolerability. At week 144, proportions with HIV-1 RNA <50 copies/mL were 30.4% (7 of 23 subjects with baseline HIV-1 RNA >1000 c/mL initially randomized to TDF), 41.7% (5 of 12 subjects with HIV-1 RNA <1000 c/mL who switched PBO to TDF) and 0% (0 of 2 subjects failed randomized PBO plus OBR with HIV-1 RNA >1000 c/mL and switched PBO to TDF). Viral resistance to TDF occurred in 1 subject. At week 144, median decrease in estimated glomerular filtration rate was 38.1 mL/min/1.73 m (n = 25). Increases in median spine (+12.70%, n = 26) and total body less head BMD (+4.32%, n = 26) and height-age adjusted Z-scores (n = 21; +0.457 for spine, +0.152 for total body less head) were observed at week 144. Five of 81 subjects (6%) had persistent >4% BMD decreases from baseline. Some subjects had virologic responses to TDF plus OBR, and TDF resistance was rare. TDF was well tolerated and can be considered for treatment of HIV-infected adolescents.
Resumo:
Atualmente, no segmento metro-ferroviário, há uma tendência para que todos os equipamentos que constituem os sistemas auxiliares de uma estação (escadas mecânicas, elevadores, bloqueadores, validadores de bilhética, ventiladores, bombas, entre outros) sejam dotados de inteligência. Tipicamente, um conjunto de equipamentos são ligados a um autómato que permite o controlo local e remoto e é vulgar que, sendo de fabricantes diferentes, suportem tecnologias distintas. Um sistema de supervisão que permita o acesso à informação disponibilizada por cada um dos autómatos, ou à atuação sobre um deles, terá por isso que implementar e suportar diversos protocolos de comunicação de forma a não ficar limitado a um tipo de tecnologia. De forma a diminuir os custos de desenvolvimento e operação de um sistema de supervisão e controlo e facilitar a integração de novos equipamentos, com diferentes características, têm sido procuradas soluções que garantam uma mais fácil comunicação entre os diversos módulos intervenientes. Nesta dissertação são implementadas soluções baseadas em clientes OPC-DA e OPC-AE e no protocolo IEC 60870-5-104, permitindo que os sistemas de supervisão e de controlo comuniquem com os equipamentos através destes três módulos. Os principais aspectos inovadores estão associados à implementação de uma arquitetura multiprotocolo usando as novas tendências de supervisão e controlo baseadas em soluções distribuídas.
Resumo:
Com o objetivo de descrever as características clínicas e laboratoriais da meningoencefalite criptocócica, foram analisados 104 prontuários de pacientes com este diagnóstico, internados no Hospital Couto Maia, na cidade de Salvador-Bahia, no período de 1972 a 1996. A idade dos pacientes variou de 8 meses a 79 anos. Sessenta e quatro (61,5%) enfermos eram do sexo masculino. O tempo de doença variou de 2 a 150 dias, com média de 27,6 dias. Os sinais e sintomas clínicos mais comuns foram cefaléia (92,7%), febre (84,4%) e rigidez de nuca (83,2%). A celularidade do líquido cefalorraquiano foi superior a 4 cels/mm+ em 95,8% dos pacientes com predominância de linfócitos em 86,3% dos casos. A letalidade foi de 42,7%.
Resumo:
Summary of Statistical Results
Resumo:
The calculation of disability-adjusted life years (DALYs) enables public health policy makers to compare the burden of disease of a specific disease with that of other (infectious) diseases. The incidence of a disease is important for the calculation of DALYs. To estimate the incidence of congenital toxoplasmosis (CT), a random sample of 10,008 dried blood spot filter paper cards from babies born in 2006 in the Netherlands were tested for Toxoplasma gondii-specific IgM antibodies. Eighteen samples were confirmed as positive for IgM, resulting in an observed birth incidence of CT of 1.8 cases per 1,000 live-born children in 2006 and an adjusted incidence of 2.0 cases per 1,000. This means that 388 infected children were born in 2006. The most likely burden of disease is estimated to be 2,300 DALYs (range 820-6,710 DALYs). In the previous calculations, using data from a regional study from 1987, this estimate was 620 DALYs (range 220-1,900 DALYs). The incidence of CT in the Netherlands is much higher than previously reported; it is 10 times higher than in Denmark and 20 times higher than in Ireland, based on estimates obtained using the same methods. There is no screening program in the Netherlands; most children will be born asymptomatic and therefore will not be detected or treated.
Resumo:
A hallmark of group/species A rotavirus (RVA) replication in MA-104 cells is the logarithmic increase in viral mRNAs that occurs four-12 h post-infection. Viral protein synthesis typically lags closely behind mRNA synthesis but continues after mRNA levels plateau. However, RVA non-structural protein 1 (NSP1) is present at very low levels throughout viral replication despite showing robust protein synthesis. NSP1 has the contrasting properties of being susceptible to proteasomal degradation, but being stabilised against proteasomal degradation by viral proteins and/or viral mRNAs. We aimed to determine the kinetics of the accumulation and intracellular distribution of NSP1 in MA-104 cells infected with rhesus rotavirus (RRV). NSP1 preferentially localises to the perinuclear region of the cytoplasm of infected cells, forming abundant granules that are heterogeneous in size. Late in infection, large NSP1 granules predominate, coincident with a shift from low to high NSP1 expression levels. Our results indicate that rotavirus NSP1 is a late viral protein in MA-104 cells infected with RRV, presumably as a result of altered protein turnover.