987 resultados para cube specimens
Resumo:
In order to quantify presence of residual BCC in patients with histologic positive margins after the first excison and to correlate the presence of residual tumor in re-excised lesions with the location of the positive margin on the first excision, a retrospective evaluation of 2053 surgically treated BCC was performed. Only 38.3% of the re-excised lesions showed residual tumor. In the group of re-excised lesions where residual BCC was found, 13% had lateral positive margin in the first excision, 39% had deep positive margin and 48% had both lateral and deep positive margins. In the group of re-excised lesions where no residual BCC was found, 49% of the primary excised lesions had lateral positive margin, 32% had deep positive margin and 19% had both deep and lateral positive margins. The association between residual tumor and positive margins was statistically significant (p = 0.01). Our findings confirm that presence of residual tumour is more likely when both lateral and deep margins are compromised.
Resumo:
The types of Haemaphysalis cinnabarina Koch and its junior synonym H. sanguinolenta Koch, both from State of Para, Brazil, have been studied. Although H. cinnabarina has been considered a synonym of H. punctata Canestrini and Fanzago (a Palearctic species), they were compared to another closely related species H. chordedis (Packard) (a Nearctic species). Based on the morphology and geographical distance among of H. cinnabarina, H. chordedis and H. punctata, we are reasonably sure that all are valid taxa. The lack of additional reports of H. cinnabarina is more related to few investigations in South America, mainly in Northern Brazil, rather than suggesting that it does not exist.
Resumo:
Statement of the Problem: Adhesive systems can spread differently onto a substrate and, consequently, influence bonding. Purpose: The purpose of this study was to evaluate the effect of differently oriented dentin surfaces and the regional variation of specimens on adhesive layer thickness and microtensile bond strength (MTBS). Materials and Methods: Twenty-four molars were sectioned mesiodistally to expose flat buccal and lingual halves. Standardized drop volumes of adhesive systems (Single Bond [SB] and Prime & Bond 2.1 [PB2.1]) were applied to dentin according to the manufacturer`s instructions. Teeth halves were randomly divided into groups: 1A-SB/parallel to gravity; 1B-SB/perpendicular to gravity; 2A-PB2.1/parallel to gravity; and 2B-PB2.1/perpendicular to gravity. The bonded assemblies were stored in 37 degrees C distilled water for 24 hours and then sectioned to obtain dentin sticks (0.8 mm(2)). The adhesive layer thickness was determined in a light microscope (x200), and after 48 hours the specimens were subjected to MTBS test. Data were analyzed by one-way and two-way analysis of variance and Student-Newman-Keuls tests. Results: Mean values (MPa +/- SD) of MTBS were: 39.1 +/- 12.9 (1A); 32.9 +/- 12.4 (1B); 52.9 +/- 15.2 (2A); and 52.3 +/- 16.5 (2B). The adhesive systems` thicknesses (mu m +/- SD) were: 11.2 +/- 2.9 (1A); 18.1 +/- 7.3 (1B); 4.2 +/- 1.8 (2A); and 3.9 +/- 1.3 (2B). No correlation between bond strength and adhesive layer thickness for both SB and PB2.1 (r = -0.224, p = 0.112 and r = 0.099, p = 0.491, respectively) was observed. Conclusions: The differently oriented dentin surfaces and the regional variation of specimens on the adhesive layer thickness are material-dependent. These variables do not influence the adhesive systems` bond strength to dentin. CLINICAL SIGNIFICANCE Adhesive systems have different viscosities and spread differently onto a substrate, influencing the bond strength and also the adhesive layer thickness. Adhesive thickness does not influence dentin bond strength, but it may impair adequate solvent evaporation, polymer conversion, and may also determine water sorption and adhesive degradation over time. In the literature, many studies have shown that the adhesive layer is a permeable membrane and can fail over timebecause ofits continuous plasticizing and degradation when in contact with water. Therefore, avoiding thick adhesive layers may minimize these problems and provide long-term success for adhesive restorations.
Resumo:
We studied the variation in toxin profiles of purified extracts of 10 individual specimens and two pools of ciguateric Caranx latus. High-performance liquid chromatography/mass spectrometry (HPLC/MS) identified in all individual samples at least seven Caribbean ciguatoxins (C-CTXs) comprising C-CTX-1 and its epimer C-CTX-2 ([M + H](+) m/z 1141.58), and five new C-CTX congeners with pseudo-molecular ions at m/z 1141.58, 1143.60, 1157.57, 1159.58, and 1127.57. In some samples, additional C-CTX isomers were detected with [M + H](+) ions at m/z 1141.58 (two), 1143.60 (one) and 1157.57 (two). The two low-toxic pools contained only four to six ciguatoxins. The comparison in relative proportions of four different mass classes ([M + H](+) at m/z 1141, 1143, 1157 and 1127) showed that the group at m/z 1157 increased (2-20%) with flesh toxicity. More than 80% of group m/z 1141 comprised C-CTX-1, C-CTX-2 and their isomer C-CTX-1 a whose level in this group correlated with fish toxicity. Contrary to low-toxic fishes, high-risk specimens had C-CTX-1 levels
Resumo:
Three Herpes Simplex Virus LightCycler polymerase chain reaction assays were compared for the detection of herpes simplex virus in 48 swab specimens. The assays comprised of one in-house assay and two commercial kits: the Artus HSV LC RealArt PCR kit and the Roche LightCycler HSV 1/2 Detection kit. On the whole, the three assays had comparable sensitivities. However, differentiation of herpes simplex virus types 1 and 2 by melting curve analysis was problematic in all assays. Overall, the results highlight the limitations of typing herpes simplex virus by melting curve analysis.
Resumo:
Deep Ocean Species. The little that is known mostly comes from collected specimens. L.A. Rocha et al. Letter "Specimen collection: An essential tool" (23 May, 344: 814) brilliantly discuss the importance of specimen collection and present the evolution of collecting since the mid-19th century until our present strict codes and conducts. However, it is also important to emphasize the fact that the vast majority of deep ocean macro-organisms are only known to us because of collection and this is a strong argument that should be present in our actions as scientists. If the deep is considered the least known of Earth’s habitats (1% or so according to recent estimates) then what awesome collection of yet to discover species are still there to be properly described? As the authors point citing (1), something around 86% of species remain unknown. Voucher specimens are fundamental for the reasons pointed out and perhaps the vast depths of the World’s oceans are the best example of that importance. The resumed report of 2010 Census of Marine Life (2) showed that among the millions of specimens collected in both familiar and seldom-explored waters, the Census found more than 6,000 potentially new species and completed formal descriptions of more than 1,200 of them. It also found that a number of rare species are in fact common. Voucher specimens are essential and, again agreeing with L.A. Rocha et al. Letter (see above), the modern approach for collecting will not be a cause for extinctions but instead a valuable tool for knowledge, description and even, as seen above, a way to find out that supposed rare species may not be that rare and even prove to reach abundant populations.
Resumo:
A specimen of porcupine fish was collected by a fisherman at Terceira Island, Azores (north-eastern Atlantic), and identified as the pelagic porcupinefish, Diodon eydouxii Brisout de Barneville, 1846, a species recently recorded for the first time from the Azores. This record, together with an examination of the first reported specimen, allowed us to compare the external morphology with Pacific specimens. The possibility of this species to be relatively common in the Azores is discussed.
Resumo:
In order to correctly assess the biaxial fatigue material properties one must experimentally test different load conditions and stress levels. With the rise of new in-plane biaxial fatigue testing machines, using smaller and more efficient electrical motors, instead of the conventional hydraulic machines, it is necessary to reduce the specimen size and to ensure that the specimen geometry is appropriated for the load capacity installed. At the present time there are no standard specimen’s geometries and the indications on literature how to design an efficient test specimen are insufficient. The main goal of this paper is to present the methodology on how to obtain an optimal cruciform specimen geometry, with thickness reduction in the gauge area, appropriated for fatigue crack initiation, as a function of the base material sheet thickness used to build the specimen. The geometry is optimized for maximum stress using several parameters, ensuring that in the gauge area the stress is uniform and maximum with two limit phase shift loading conditions. Therefore the fatigue damage will always initiate on the center of the specimen, avoiding failure outside this region. Using the Renard Series of preferred numbers for the base material sheet thickness as a reference, the reaming geometry parameters are optimized using a derivative-free methodology, called direct multi search (DMS) method. The final optimal geometry as a function of the base material sheet thickness is proposed, as a guide line for cruciform specimens design, and as a possible contribution for a future standard on in-plane biaxial fatigue tests. © 2014, Gruppo Italiano Frattura. All rights reserved.
Resumo:
An Immunoperoxidase technique for identification of leptospires in formalin fixed, paraffin embedded kidney sections is presented, using peroxidase-antiperoxidase complex. The anti-leptospiral antibody was raised in rabbit. Possible applications of this technique are discussed.
Resumo:
In order to correctly assess the biaxial fatigue material properties one must experimentally test different load conditions and stress levels. With the rise of new in-plane biaxial fatigue testing machines, using smaller and more efficient electrical motors, instead of the conventional hydraulic machines, it is necessary to reduce the specimen size and to ensure that the specimen geometry is appropriate for the load capacity installed. At the present time there are no standard specimen's geometries and the indications on literature how to design an efficient test specimen are insufficient. The main goal of this paper is to present the methodology on how to obtain an optimal cruciform specimen geometry, with thickness reduction in the gauge area, appropriate for fatigue crack initiation, as a function of the base material sheet thickness used to build the specimen. The geometry is optimized for maximum stress using several parameters, ensuring that in the gauge area the stress distributions on the loading directions are uniform and maximum with two limit phase shift loading conditions (delta = 0 degrees and (delta = 180 degrees). Therefore the fatigue damage will always initiate on the center of the specimen, avoiding failure outside this region. Using the Renard Series of preferred numbers for the base material sheet thickness as a reference, the reaming geometry parameters are optimized using a derivative-free methodology, called direct multi search (DMS) method. The final optimal geometry as a function of the base material sheet thickness is proposed, as a guide line for cruciform specimens design, and as a possible contribution for a future standard on in-plane biaxial fatigue tests
Resumo:
In this work tubular fiber reinforced specimens are tested for fatigue life. The specimens are biaxially loaded with tension and shear stresses, with a load angle β of 30° and 60° and a load ratio of R=0,1. There are many factors that affect fatigue life of a fiber reinforced material and the main goal of this work is to study the effects of load ratio R by obtaining S-N curves and compare them to the previous works (1). All the other parameters, such as specimen production, fatigue loading frequency and temperature, will be the same as for the previous tests. For every specimen, stiffness, temperature of the specimen during testing, crack counting and final fracture mode are obtained. Prior to testing, a study if the literature regarding the load ratio effects on composites fatigue life and with that review estimate the initial stresses to be applied in testing. In previous works (1) similar specimens have only been tested for a load ratio of R=-1 and therefore the behaviour of this tubular specimens for a different load ratio is unknown. All the data acquired will be analysed and compared to the previous works, emphasizing the differences found and discussing the possible explanations for those differences. The crack counting software, developed at the institute, has shown useful before, however different adjustments to the software parameters lead to different cracks numbers for the same picture, and therefore a better methodology will be discussed to improve the crack counting results. After the specimen’s failure, all the data will be collected and stored and fibre volume content for every specimen is also determinate. The number of tests required to make the S-N curves are obtained according to the existent standards. Additionally are also identified some improvements to the testing machine setup and to the procedures for future testing.
Resumo:
Sample preparation and DNA extraction protocols for DNA amplification by PCR, which can be applied in human fecal samples for taeniasis diagnosis, are described. DNA extracted from fecal specimens with phenol/chloroform/isoamilic alcohol and DNAzol® reagent had to be first purified to generate fragments of 170 pb and 600 pb by HDP2-PCR. This purification step was not necessary with the use of QIAmp DNA stool mini kit®. Best DNA extraction results were achieved after eggs disruption with glass beads, either with phenol/chloroform/isoamilic alcohol, DNAzol® reagent or QIAmp DNA stool mini kit®.