939 resultados para conventional PCR


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Conventional PCR (PCRTeq) for diagnosing Theileria equi and multiplex PCR (M/PCRTeq-Bc) for diagnosing T. equi and Babesia caballi were comparatively evaluated with nested PCR (N/PCR-Teq) for diagnosing equine piroplasmosis. In DNA sensitivity determinations, in multiple dilutions of equine blood that had tested positive for T. equi, PCR-Teq and N/PCR-Teq detected hemoparasite DNA in the larger dilutions (1:128), but did not differ significantly from the M/PCRTeq-Bc (1:64). In analyses on equine serum tested by ELISA, there was high agreement between this serological test and PCR-Teq (k = 0.780) and moderate agreement with N/PCR-Teq (k = 0.562) and M/PCRTeq-Bc (k = 0.488). PCR-Teq found a higher frequency of T. equi both in extensively and intensively reared horses, but this was not significant in relation to N/PCR-Teq (P>0.05), and both PCRs indicated that there was an endemic situation regarding T. equi in the population of horses of this sample. PCR-Teq was only significantly different from M/PCR-Teq-Bc (P<0.05). PCR-Teq presented high sensitivity and specificity, comparable to N/PCR-Teq, but with the advantage of higher speed in obtaining results and lower costs and risks of laboratory contamination. This accredits PCR-Teq for epidemiological studies and for determinations on affected horses.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Group A Rotavirus (RVA) is one of the most common causes of diarrhea in humans and several animal species. A SYBR-Green Real-Time polymerase chain reaction (PCR) was developed to diagnose RVA from porcine fecal samples, targeting amplification of a 137-bp fragment of nonstructural protein 5 (NSP5) gene using mRNA of bovine NADH-desidrogenase-5 as exogenous internal control. Sixty-five samples were tested (25 tested positive for conventional PCR and genetic sequencing). The overall agreement (kappa) was 0.843, indicating 'very good' concordance between tests, presenting 100% of relative sensitivity (25+ Real Time PCR/25+ Conventional PCR) and 87.5% of relative sensitivity (35- Real Time PCR/40- Conventional PCR). The results also demonstrated high intra- and inter-assay reproducibility (coefficient of variation ≤1.42%); thus, this method proved to be a fast and sensitive approach for the diagnosis of RVA in pigs.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Hereditary hemochromatosis (HH) is a common autosomal disorder of iron metabolism mainly affecting Caucasian populations. Three recurrent disease-associated mutations have been detected in the hemochromatosis gene (HFE): C282Y, H63D, and S65C. Although HH phenotype has been associated with all three mutations, C282Y is considered the most relevant mutation responsible for hemochromatosis. Clinical complications of HH include cirrhosis of the liver, congestive cardiac failure and cardiac arrhythmias, endocrine pancreatic disease, which can be prevented by early diagnosis and treatment. Therefore, a reliable genotyping method is required for presymptomatic diagnosis. We describe the simultaneous detection of the C282Y, H63D and S65C mutations in the hemochromatosis gene by real-time PCR followed by melting curve analysis using fluorescence resonance energy transfer (FRET) probes. The acceptor fluorophore may be replaced by a quencher, increasing multiplex possibilities. Real-time PCR results were compared to the results of sequencing and conventional PCR followed by restriction digestion and detection by agarose gel electrophoresis (PCR-RFLP). Genotypes from 80 individuals obtained both by the conventional PCR-RFLP method and quenched-FRET real-time PCR were in full agreement. Sequencing also confirmed the results obtained by the new method, which proved to be an accurate, rapid and cost-effective diagnostic assay. Our findings demonstrate the usefulness of real-time PCR for the simultaneous detection of mutations in the HFE gene, which allows a reduction of a significant amount of time in sample processing compared to the PCR-RFLP method, eliminates the use of toxic reagents, reduces the risk of contamination in the laboratory, and enables full process automation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aim: To develop a TaqMan probe-based, highly sensitive and specific quantitative PCR (qPCR) assay for the detection and quantification of Mycoplasma suis in the blood of pigs. Methods and Results: Primers and probes specific to Myc. suis 16S rRNA gene were designed. The qPCR assay`s specificity, detection limit, intra- and inter-assay variability were evaluated and its performance was compared with a Myc. suis conventional PCR assay (cPCR). Blood of two experimentally infected pigs, 40 Indiana pigs, 40 Brazilian sows and 28 peccaries were tested. The assay detected as few as ten copies of Myc. suis plasmids and was 100-fold more sensitive than the cPCR. No cross-reactivity with nontarget pig mycoplasmas was observed. An average of 1.62 x 10(11) and 2.75 x 10(8) target copies ml(-1) of blood were detected in the acutely and chronically infected pigs, respectively. Three (7.5%) pigs and 32 (80.0%) sows were positive while all peccaries were negative for Myc. suis. Conclusion: The developed qPCR assay is highly sensitive and specific for Myc. suis detection and quantification. Significance and Impact of the Study: TaqMan qPCR is an accurate and quick test for detection of Myc. suis infected pigs, which can be used on varied instrumentation platforms.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Dentre as doenças cardiovasculares, a trombose venosa (TV) destaca-se pela associação entre fatores de riscos adquiridos e fatores genéticos. A resistência hereditária à proteína C ativada tem sido identificada como a principal causa dos casos de trombose venosa, sendo frequentemente associada à mutação fator V Leiden (G1694A). Em indivíduos homozigotos, o risco de trombose venosa é 50 a 100 vezes maior que em pacientes homozigotos normais, enquanto em pacientes heterozigotos o risco é de 5 a 10 vezes. Baseado na necessidade de avaliação e acompanhamento de pacientes com casos de trombose venosa e prevenção de seus respectivos familiares, foi desenvolvido um método simples de discriminação alélica do fator V da coagulação utilizando PCR em tempo real. Foram selecionados 67 pacientes com histórico de TV e 51 indivíduos sem histórico de TV. Primeiramente, a discriminação alélica do fator V foi realizada através de PCR convencional seguida de digestão enzimática (Mnl). Posteriormente, o diagnóstico foi realizado por PCR em tempo real. Ambos os métodos foram baseados no polimorfismo G1691A, sendo no segundo utilizado fluoróforos VIC e FAM para marcar os nucleotídeos G e A, respectivamente. A técnica de PCR-RFLP foi utilizada para diagnosticar 95 indivíduos homozigotos normais, 21 heterozigotos e 2 homozigotos FVL. Utilizando PCR em tempo real foram obtidos os mesmos resultados. A máxima similaridade entre os resultados obtidos por PCR em tempo real e PCR-RFLP indicou precisão significativa do novo método de discriminação e visualização alélica do fator V.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Post-mortem bacterial culture and specific biochemical tests are currently performed to characterize the etiologic agent of bovine tuberculosis. Cultures take up to 90 days to develop. A diagnosis by molecular tests such as PCR can provide fast and reliable results while significantly decreasing the time of confirmation. In the present study, a nested-PCR system, targeting rv2807, with conventional PCR followed by real-time PCR, was developed to detect Mycobacterium tuberculosis complex (MTC) organisms directly from bovine and bubaline tissue homogenates. The sensitivity and specificity of the reactions were assessed with DNA samples extracted from tuberculous and non-tuberculous mycobacteria, as well as other Actinomycetales species and DNA samples extracted directly from bovine and bubaline tissue homogenates. Regarding the analytical sensitivity, DNA of the M. bovis AN5 strain was detected up to 1.5 pg by nested-PCR, whereas DNA of M. tuberculosis H37Rv strain was detected up to 6.1 pg. The nested-PCR system showed 100% analytical specificity for MTC when tested with DNA of reference strains of non-tuberculous mycobacteria and closely-related Actinomycetales. A clinical sensitivity level of 76.7% was detected with tissues samples positive for MTC by means of the culture and conventional PCR. A clinical specificity of 100% was detected with DNA from tissue samples of cattle with negative results in the comparative intradermal tuberculin test. These cattle exhibited no visible lesions and were negative in the culture for MTC. The use of the nested-PCR assay to detect M. tuberculosis complex in tissue homogenates provided a rapid diagnosis of bovine and bubaline tuberculosis.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Ureaplasma diversum in veterinary studies is an undesirable microbe, which may cause infection in bulls and may result in seminal vesiculitis, balanopostitis, and alterations in spermatozoids, whereas in cows, it may cause placentitis, fetal alveolitis, abortion, and birth of weak calves. U. diversum is released through organic secretions, especially semen, preputial and vaginal mucus, conjunctival secretion, and milk. The aim of the present study was to develop a TaqMan probe, highly sensitive and specific quantitative PCR (qPCR) assay for the detection and quantification of U. diversum from genital swabs of bovines. Primers and probes specific to U. diversum 16S rRNA gene were designed. The specificity, detection limit, intra- and inter-assay variability of qPCR to detect this ureaplasma was compared with the results of the conventional PCR assay (cPCR). Swabs of vaginal mucus from 169 cows were tested. The qPCR assay detected as few as 10 copies of U. diversum and was 100-fold more sensitive than the cPCR. No cross-reactivity with other Mollicutes or eubacteria was observed. U. diversum was detected in 79 swabs (46.42%) by qPCR, while using cPCR it was detected in 42 (25%) samples. The difference in cPCR and qPCR ureaplasma detection between healthy and sick animals was not statistically significant. But the U. diversum load in samples from animals with genital disorders was higher than in healthy animals. The qPCR assay developed herein is highly sensitive and specific for the detection and quantification of U. diversum in vaginal bovine samples.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Use of PCR in the field of molecular diagnostics has increased to the point where it is now accepted as the standard method for detecting nucleic acids from a number of sample and microbial types. However, conventional PCR was already an essential tool in the research laboratory. Real-time PCR has catalysed wider acceptance of PCR because it is more rapid, sensitive and reproducible, while the risk of carryover contamination is minimised. There is an increasing number of chemistries which are used to detect PCR products as they accumulate within a closed reaction vessel during real-time PCR. These include the non-specific DNA-binding fluorophores and the specific, fluorophore-labelled oligonucleotide probes, some of which will be discussed in detail. It is not only the technology that has changed with the introduction of real-time PCR. Accompanying changes have occurred in the traditional terminology of PCR, and these changes will be highlighted as they occur. Factors that have restricted the development of multiplex real-time PCR, as well as the role of real-time PCR in the quantitation and genotyping of the microbial causes of infectious disease, will also be discussed. Because the amplification hardware and the fluorogenic detection chemistries have evolved rapidly, this review aims to update the scientist on the current state of the art. Additionally, the advantages, limitations and general background of real-time PCR technology will be reviewed in the context of the microbiology laboratory.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study investigated the presence of the Treponema species in longstanding endodontic retreatment-resistant lesions of teeth with apical periodontitis, the association of this species with clinical/radiographic features, and the association among the different target species. Microbial samples of apical lesions were collected from twenty-five adult patients referred to endodontic surgery after unsuccessful root canal retreatment. Nested-PCR and conventional PCR were used for Treponema detection. Twenty-three periradicular tissue samples showed detectable levels of bacterial DNA. Treponema species were detected in 28% (7/25) of the cases. The most frequently detected species were T. socranskii (6/25), followed by T. maltophilum (3/25), T. amylovorum (3/25), T. lecithinolyticum (3/25), T. denticola (3/25), T. pectinovorum (2/25) and T. medium (2/25). T. vicentii was not detected in any sample. Positive statistical association was found between T. socranskii and T. denticola, and between T. maltophilum and T. lecithinolyticum . No association was detected between the presence of any target microorganism and the clinical or radiographic features. Treponema spp. are present, in a low percentage, in longstanding apical lesions from teeth with endodontic retreatment failure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

About 95% of HTLV-1 infected patients remain asymptomatic throughout life, and the risk factors associated with the development of related diseases, such as HAM/TSP and ATL, are not fully understood. The human leukocyte antigen-G molecule (HLA-G), a nonclassical HLA class I molecule encoded by MHC, is expressed in several pathological conditions, including viral infection, and is related to immunosuppressive effects that allow the virus-infected cells to escape the antiviral defense of the host. The 14-bp insertion/deletion polymorphism of exon 8 HLA-G gene influences the stability of the transcripts and could be related to HTLV-1-infected cell protection and to the increase of proviral load. The present study analyzed by conventional PCR the 14-bp insertion/deletion polymorphism of exon 8 HLA-G gene in 150 unrelated healthy subjects, 82 HTLV-1 infected patients with symptoms (33 ATL and 49 HAM), and 56 asymptomatic HTLV-1 infected patients (HAC). In addition, the proviral load was determined by quantitative real-time PCR in all infected groups and correlated with 14-bp insertion/deletion genotypes. The heterozygote genotype frequencies were significantly higher in HAM, in the symptomatic group, and in infected patients compared to control (p < 0.05). The proviral load was higher in the symptomatic group than the HAC group (p < 0.0005). The comparison of proviral load and genotypes showed that -14-bp/-14-bp genotype had a higher proviral load than +14-bp/-14-bp and +14-bp/+14-bp genotypes. Although HLA-G 14-bp polymorphism does not appear to be associated

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Detection and quantification of human papillomavirus (HPV) may help in predicting the evolution of HPV infection and progression of associated lesions. Objectives: We propose a novel protocol using consensus primers GP5+/6+ in a SYBR Green quantitative real-time (Q-RT) polymerase chain reaction (PCR). The strategy permits screening for HPV infection and viral load quantification simultaneously. Study design: DNA from 153 archived cervical samples, previously tested for HPV detection by GP5+/6+ PCR and typed by EIA-RLB (enzyme immunoassay-reverse line blot) or sequence analysis, was analysed using SYBR Green Q-RT PCR. Melting temperature assay (T(m)) and cycle threshold (C(t)) were used to evaluate HPV positivity and viral load. The T(m) in the range of 77-82 degrees C was considered to be positive for HPV-DNA. HPV results generated through GP5+/6+ conventional PCR were considered the gold standard against which sensitivity and specificity of our assay were measured. Results: Out of 104 HPV positive samples, 100 (96.2%) were also determined as positive by SYBR Green Q-RT PCR; of the 49 HPV-negative samples, all were determined as negative. There was an excellent positivity agreement (K = 0.94) between the SYBR Green Q-RT and the previous methods employed. The specificity and sensitivity were 100% and 96.2%, respectively. Comparison of SYBR Green Q-RT and TaqMan oligo-probe technologies gave an excellent concordance (pc = 0.95) which validated the proposed strategy. Conclusions: We propose a sensitive and easy-to-perform technique for HPV screening and viral load quantification simultaneously. (C) 2009 Elsevier B.V. All rights reserved.