1000 resultados para consumo de oxigênio
Resumo:
The relation between metabolic demand and maximal oxygen consumption during exercise have been investigated in different areas of knowledge. In the health field, the determination of maximal oxygen consumption (VO2max) is considered a method to classify the level of physical fitness or the risk of cardiocirculatory diseases. The accuracy to obtain data provides a better evaluation of functional responses and allows a reduction in the error margin at the moment of risk classification, as well as, at the moment of determination of aerobic exercise work load. In Brasil, the use of respirometry associated to ergometric test became an opition in the cardiorespiratory evaluation. This equipment allows predictions concerning the oxyredutase process, making it possible to identify physiological responses to physical effort as the respiratory threshold. This thesis focused in the development of mathematical models developed by multiple regression validated by the stepwise method, aiming to predict the VO2max based on respiratory responses to physical effort. The sample was composed of a ramdom sample of 181 healthy individuals, men and women, that were randomized to two groups: regression group and cross validation group (GV). The voluntiars were submitted to a incremental treadmill test; objetiving to determinate of the second respiratory threshold (LVII) and the Peak VO2max. Using the método forward addition method 11 models of VO2max prediction in trendmill were developded. No significative differences were found between the VO2max meansured and the predicted by models when they were compared using ANOVA One-Way and the Post Hoc test of Turkey. We concluded that the developed mathematical models allow a prediction of the VO2max of healthy young individuals based on the LVII
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to investigate the influence of different assessment time periods of submaximal tests on the determination of the maximal accumulated oxygen deficit (MAOD), through the adoption of different time slots of 4 to 6, 6 to 8 and 8 to 10 min. Ten cyclists with mean age of 27.5 ± 4.1 years, body mass 74.4 ± 12.7 kg and time experience of 9.8 ± 4.7 years participated in this study. The athletes underwent an incremental exercise test to determine the peak oxygen consumption (VO2peak), and four submaximal constant work-load test sessions (60, 70, 80 and 90% VO2peak) of 10 min in order to estimate the O2 demand (DEO2). The mean VO2 values obtained on each constant work-load for the 4 to 6, 6 to 8 and 8 to 10 min time-periods intervals were used to perform a linear regression between the intensity and O2 consumption for each time-period. In addition, the subjects performed one supramaximal rectangular test (110% VO2peak) for the quantification of MAOD. There was no significant difference in VO2 between the different time-periods for all submaximal tests (P> 0.05). Similarly, no significant difference was found in DEAO2 and MAOD (P> 0.05). Furthermore, the values of MAOD for the three time-periods intervals showed good agreement and strong correlation. Thus, the data suggest that the submaximal tests used to estimate the values of MAOD can be reduced, at least in this type of sample, and with the use of a cycle simulator.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Introdução – Os componentes protésicos têm um papel fundamental na eficiência energética da marcha dos indivíduos amputados. Esta é uma área de conhecimento ainda em desenvolvimento, onde a investigação desempenha um papel central. Objectivos – Comparar e analisar o efeito de dois joelhos protésicos, 3R34, monocêntrico modular, de fricção constante, com auxiliar de extensão incorporado (A) e 3R92, monocêntrico modular, com travão de fricção e controlo pneumático da fase de balanço (B) no consumo energético e eficiência da marcha. Metodologia – Um indivíduo do sexo masculino de 27 anos, com amputação transfemural longa, foi sujeito a um protocolo submáximo de avaliação da resposta ao exercício em passadeira rolante (H/P/Cosmos(R) Mercury), através de um sistema de análise de gases breath‑by‑breath (Cosmed Quark PFT Ergo). Foi efetuado o mesmo protocolo com intervalo de dois dias, primeiro utilizando o joelho A e depois o B. As variáveis analisadas foram o consumo de O2 (VO2), o equivalente metabólico (MET) e a eficiência energética da marcha (Quociente de VO2 esperado de um individuo saudável e o VO2 do individuo em estudo). O esforço percecionado foi medido com a escala RPE de Borg. Resultados – O consumo energético com o joelho A (24,2 ml O2/kg/min; 6,9 MET) foi inferior ao obtido com o joelho B (28,68 ml O2/kg/min; 8,2 MET). A eficiência energética da marcha foi mais elevada para o joelho A (43%) do que para o joelho B (39%). Conclusão – A utilização do joelho A na prótese do indivíduo em estudo resulta numa marcha de menor consumo energético e maior eficiência. No entanto, este valor poderá estar influenciado pelo curto período de adaptação ao joelho B, sendo necessários mais estudos para confirmar os resultados do estudo e a influência deste fator. ABSTRACT - Background – Prosthetic components have a crucial role in the energy efficiency of amputee’s gait. This is an area of knowledge still in development, where research plays a central role. Objective – The purpose of this case study is to compare the impact in energy consumption of two prosthetic knees, titanium single‑axis constant friction knee joint with internal extension assist, 3R34 (A) and a single‑axis pneumatic swing phase control, 3R92 (B). Methodology – The participant was a transtibial amputee, male, with 27 years old, with no other clinical or functional impairments. To measure the energy expenditure a submaximal treadmill (H/P/Cosmos(R) Mercury) exercise stress test combined with a breath‑by‑breath analysis system (Cosmed Quark PFT Ergo) was used. The same test was applied to both knees, separated by two days. The analyzed variables were O2 consumption (VO2), metabolic equivalent (MET) and gait efficiency (VO2 ratio expected from a healthy individual and the studied individual). A rate of perceived exertion (Borg’s Scale) was used. Results – The results were favorable to knee A (24.2 ml O2/kg/min; 6.9 MET, 43% efficiency) compared with knee B (28.68 ml O2/kg/min; 8.2 MET, 39% efficiency). Conclusion – In this case, a less energy consumption gait corresponds to the prosthesis with knee A. These values may be influenced by the short adaptation period with knee B, so it’s necessary to perform more studies to confirm the previous results and to understand the truly impact of correct adaptation factor to the best prosthetics components for different patients.
Resumo:
Introdução - O achatamento da curva do pulso de oxigênio durante o teste de esforço cardiopulmonar com cargas progressivas tem sido proposto para melhorar a acurácia diagnóstica da isquemia miocárdica induzida pelo esforço. Entretanto, este critério não foi formalmente avaliado em pacientes de baixo risco, para os quais a melhora da acurácia diagnóstica pode ser clinicamente mais relevante. Objetivo - Testar a hipótese de que o achatamento da curva do pulso de oxigênio durante o teste de esforço cardiopulmonar pode detectar isquemia miocárdica extensa, mas não detectar isquemia miocárdica leve, usando como padrão ouro a cintilografia de perfusão miocárdica. Métodos - Oitenta e sete pacientes (idade média ± DP de 57 ± 11 anos, 64% do sexo masculino) referidos para cintilografia de perfusão miocárdica com exercício para diagnóstico de isquemia miocárdica foram também avaliados com teste de esforço cardiopulmonar. Um investigador identificou prospectivamente os pacientes que apresentaram defeito transitório de perfusão induzido pelo exercício na cintilografia miocárdica com 99mTcsestamibi. Outro investigador avaliou a resposta do pulso de oxigênio durante o exercício de cargas progressivas, sem o conhecimento da resposta eletrocardiográfica ou dos achados da cintilografia. Resultados - A cintilografia de perfusão miocárdica com exercício detectou defeitos transitórios de perfusão em 36% dos pacientes. Comparados com os pacientes com estudos de perfusão normal, os pacientes com isquemia vii induzida pelo exercício apresentaram duplo produto máximo (Isquemia: 33060±5489; Sem Isquemia: 31826±5343; p=0,17), consumo de oxigênio de pico (VO2 pico) (Isquemia: 29±8 mL/kg.min; Sem Isquemia: 30±8 mL/kg.min; p=0,59) e consumo de oxigênio do limiar anaeróbio (Isquemia: 64±12%; Sem Isquemia: 61±13%; p=0,15) similares. O pulso de oxigênio analisado a 25% (9,7±2 vs 9,3±2 ml/b), 50% (11,2±3 vs 10,8±3 ml/b), 75% (12,5±3 vs 11,9±3 ml/b) do VO2 pico, e no pico do exercício (15±4 vs 14±4 ml/b), não foram diferentes no grupo com Isquemia e Sem Isquemia, respectivamente. Entretanto, os pacientes com defeitos perfusionais transitórios extensos durante o exercício apresentaram um pulso de oxigênio no pico menor (12,8±3,8 vs 16,4±4,6 mL/b; p=0,035) e demonstraram um achatamento detectável na curva de pulso de oxigênio. Conclusão - A análise da resposta do pulso de oxigênio ao teste de esforço com cargas progressivas não identifica isquemia miocárdica leve. O achatamento do pulso de oxigênio no teste de esforço de cargas progressivas está presente apenas nos pacientes com isquemia miocárdica extensa.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
OBJETIVE: Investigate the cardiopulmonary responses of one strength training session in young women. METHOD: Twenty-three women aged between 18 and 29 years participated in this study. All the volunteers were submitted to the following tests: cardiopulmonary and one-repetition maximum (1-RM). The strength training protocol had emphasis on muscular hypertrophy, three sets from eight to twelve repetitions under 70% of 1-RM, with a one minute thirty-second break between sets. During the training session, the cardiopulmonary variables were measured with a metabolic gas analyzer and a telemetry module. RESULTS: The results of the oxygen consumption in the training session were from 8.43 + 1.76 ml/kg/min and of the heart rate of 108.08 + 15.26 bpm. The results of the oxygen consumption and of the heart rate in the training were lower (p < 0.01) than in the ventilatory threshold and of the oxygen consumption and the heart rate reserves. CONCLUSION: The obtained data show that the present protocol of strength training provided low overload to the cardiopulmonary system of young women.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física