994 resultados para computer tomography
Resumo:
Bone loss may result from remodelling initiated by implant stress protection. Quantifying remodelling requires bone density distributions which can be obtained from computed tomography scans. Pre-operative scans of large animals however are rarely possible. This study aimed to determine if the contra-lateral bone is a suitable control for the purpose of quantifying bone remodelling. CT scans of 8 pairs of ovine tibia were used to determine the likeness of left and right bones. The deviation between the outer surfaces of the bone pairs was used to quantify geometric similarity. The density differences were determined by dividing the bones into discrete volumes along the shaft of the tibia. Density differences were also determined for fractured and contra-lateral bone pairs to determine the magnitude of implant related remodelling. Left and right ovine tibiae were found to have a high degree of similarity with differences of less than 1.0 mm in the outer surface deviation and density difference of less than 5% in over 90% of the shaft region. The density differences (10–40%) as a result of implant related bone remodelling were greater than left-right differences. Therefore, for the purpose of quantifying bone remodelling in sheep, the contra-lateral tibia may be considered an alternative to a pre-operative control.
Resumo:
Orthopaedic fracture fixation implants are increasingly being designed using accurate 3D models of long bones based on computer tomography (CT). Unlike CT, magnetic resonance imaging (MRI) does not involve ionising radiation and is therefore a desirable alternative to CT. This study aims to quantify the accuracy of MRI-based 3D models compared to CT-based 3D models of long bones. The femora of five intact cadaver ovine limbs were scanned using a 1.5T MRI and a CT scanner. Image segmentation of CT and MRI data was performed using a multi-threshold segmentation method. Reference models were generated by digitising the bone surfaces free of soft tissue with a mechanical contact scanner. The MRI- and CT-derived models were validated against the reference models. The results demonstrated that the CT-based models contained an average error of 0.15mm while the MRI-based models contained an average error of 0.23mm. Statistical validation shows that there are no significant differences between 3D models based on CT and MRI data. These results indicate that the geometric accuracy of MRI based 3D models was comparable to that of CT-based models and therefore MRI is a potential alternative to CT for generation of 3D models with high geometric accuracy.
Resumo:
O uso de modelos de estudo dentários faz parte tanto da prática quanto da pesquisa odontológica e ortodôntica. Com a introdução dos scanners 3D e dos tomógrafos CBCT (cone beam computer tomography) tornou-se possível a obtenção de modelos dentários tridimensionais virtuais das arcadas dentárias. Foram selecionados 56 modelos dentários superiores e escaneados em três tipos diferentes de scanners: Maestro 3D Dental Scanner (AGE Solutions, Potedera, Italia), 3Shape R700 3D Scanner (3Shape, Copenhagen, Dinamarca) e o scanner 3Shape TRIOS (3Shape, Copenhagen, Dinamarca). Doze medidas foram realizadas nos modelos dentários de gesso e comparadas com as mesmas medidas realizadas nos modelos dentários digitais por meio do teste de Análise de Variância (ANOVA). Estatisticamente não foram encontradas diferenças significativas entre as medições tradicionais nos modelos dentários de gesso e as medidas realizadas nos modelos dentários digitais. Os três tipos de métodos de aquisição de modelos dentários digitais foram considerados confiáveis para as medições horizontais, transversais e verticais. Os modelos dentários virtuais podem ser indicados como substitutos dos modelos dentários de gesso.
Resumo:
Deep ocean sediments off the west coast of Africa exhibit a peculiar undrained strength profile in the form of a crust, albeit of exceptionally high water content, overlying normally consolidated clay. Hot-oil pipelines are installed into these crustal sediments, so their origins and characteristics are of great interest to pipeline designers. This paper provides evidence for the presence of burrowing invertebrates in crust material, and for the way sediment properties are modified through their creation of burrows, and through the deposition of faecal pellets. A variety of imaging techniques are used to make these connections, including photography, scanning electron microscopy and X-ray computer tomography. However, the essential investigative technology is simply the wet-sieving of natural cores, which reveals that up to 60% by dry mass of the crustal material can consist of smooth, highly regular, sand-sized capsules that have been identified as the faecal pellets of invertebrates such as polychaetes. Mechanical tests reveal that these pellets are quite robust under effective stresses of the order of 10 kPa, acting like sand grains within a matrix of fines. Their abundance correlates closely with the measured strength of the crust. While this can easily be accepted in the context of a pellet fraction as high as 60%, the question arises how a smaller proportion of pellets, such as 20%, is apparently able to enhance significantly the strength of a sediment that otherwise appears to be normally consolidated. A hypothesis is suggested based on the composition of the matrix of fines around the pellets. These appear to consist of agglomerates of clay platelets, which may be the result of the breakdown of pellets by other organisms. Their continued degradation at depths in excess of 1 m is taken to explain the progressive loss of crustal strength thereafter.
Resumo:
C.R. Bull and R. Zwiggelaar, 'Discrimination between low atomic number materials from their characteristic scattering of X-ray radiation', Journal of Agricultural Engineering Research 68 (2), 77-87 (1997)
Resumo:
Porous poly(L-lactic acid) (PLA) scaffolds of 85 per cent and 90 per cent porosity are prepared using polymer sintering and porogen leaching method. Different weight fractions of 10 per cent, 30 per cent, and 50 per cent of hydroxyapatite (HA) are added to the PLA to control the acidity and degradation rate. The three-dimensional (3D) morphology and surface porosity are tested using micro-computer tomography (micro-CT), optical microscopy, and scanning electron microscopy (SEM). Results indicate that the surface porosity does not change on the addition of HA. The micro-CT examinations show a slight decrease in the pore size and increase in the wall thickness accompanied by reduced anisotropy for the scaffolds containing HA. Scanning electron micrographs show detectable interconnected pores for the scaffold with pure PLA. Addition of the HA results in agglomeration of the HA particles and reduced leaching of the porogen. Compression tests of the scaffold identify three stages in the stress-strain curve. The addition of HA results in a reduction in the modulus of the scaffold at the first stage of elastic bending of the wall, but this is reversed for the second and third stages of collapse of the wall and densification in the compression tests. In the scaffolds with 85 per cent porosity, the addition of a high percentage of HA could result in 70 per cent decrease in stiffness in the first stage, 200 per cent increase in stiffness in the second stage, and 20 per cent increase in stiffness in the third stage. The results of these tests are compared with the Gibson cellular material model that is proposed for prediction of the behaviour of cellular material under compression. The pH and molecular weight changes are tracked for the scaffolds within a period of 35 days. The addition of HA keeps the pH in the alkaline region, which results in higher rate of degradation at an early period of observation, followed by a reduced rate of degradation later in the process. The final molecular weight is higher for the scaffolds with HA than for scaffolds of pure PLA. The manufactured scaffolds offer acceptable properties in terms of the pore size range and interconnectivity of the pores and porosity for non-load-bearing bone graft substitute; however, improvement to the mixing of the phases of PLA and HA is required to achieve better integrity of the composite scaffolds. © 2008 IMechE.
Resumo:
Aims/hypothesis - It is not known whether the beneficial effects of exercise training on insulin sensitivity are due to changes in hepatic and peripheral insulin sensitivity or whether the changes in insulin sensitivity can be explained by adaptive changes in fatty acid metabolism, changes in visceral fat or changes in liver and muscle triacylglycerol content. We investigated the effects of 6 weeks of supervised exercise in sedentary men on these variables. Subjects and methods - We randomised 17 sedentary overweight male subjects (age 50 ± 2.6 years, BMI 27.6 ± 0.5 kg/m2) to a 6-week exercise programme (n = 10) or control group (n = 7). The insulin sensitivity of palmitic acid production rate (Ra), glycerol Ra, endogenous glucose Ra (EGP), glucose uptake and glucose metabolic clearance rate were measured at 0 and 6 weeks with a two-step hyperinsulinaemic–euglycaemic clamp [step 1, 0.3 (low dose); step 2, 1.5 (high dose) mU kg−1 min−1]. In the exercise group subjects were studied >72 h after the last training session. Liver and skeletal muscle triacylglycerol content was measured by magnetic resonance spectroscopy and visceral adipose tissue by cross-sectional computer tomography scanning. Results - After 6 weeks, fasting glycerol, palmitic acid Ra (p = 0.003, p = 0.042) and NEFA concentration (p = 0.005) were decreased in the exercise group with no change in the control group. The effects of low-dose insulin on EGP and of high-dose insulin on glucose uptake and metabolic clearance rate were enhanced in the exercise group but not in the control group (p = 0.026; p = 0.007 and p = 0.04). There was no change in muscle triacylglycerol and liver fat in either group. Conclusions/interpretation - Decreased availability of circulating NEFA may contribute to the observed improvement in the insulin sensitivity of EGP and glucose uptake following 6 weeks of moderate exercise.
Resumo:
*** Purpose – Computer tomography (CT) for 3D reconstruction entails a huge number of coplanar fan-beam projections for each of a large number of 2D slice images, and excessive radiation intensities and dosages. For some applications its rate of throughput is also inadequate. A technique for overcoming these limitations is outlined. *** Design methodology/approach – A novel method to reconstruct 3D surface models of objects is presented, using, typically, ten, 2D projective images. These images are generated by relative motion between this set of objects and a set of ten fanbeam X-ray sources and sensors, with their viewing axes suitably distributed in 2D angular space. *** Findings – The method entails a radiation dosage several orders of magnitude lower than CT, and requires far less computational power. Experimental results are given to illustrate the capability of the technique *** Practical implications – The substantially lower cost of the method and, more particularly, its dramatically lower irradiation make it relevant to many applications precluded by current techniques *** Originality/value – The method can be used in many applications such as aircraft hold-luggage screening, 3D industrial modelling and measurement, and it should also have important applications to medical diagnosis and surgery.
Resumo:
A doença vascular encefálica (AVE) é a principal causa de morte no Brasil. As seqüelas em indivíduos pós-acidente vascular encefálico incluem distúrbios motores, distúrbios de fala ou de linguagem e distúrbios de deglutição. A disfagia orofaríngea ocorre em cerca de 50% dos pacientes com AVE. Este estudo teve por objetivo determinar a incidência da disfagia após AVE. Foram avaliados todos os pacientes que deram entrada em hospital universitário de referência no período de um ano, tão logo apresentassem condições para avaliação clínica, fonoaudiológica e neurológica (102 pacientes), com análise objetiva da deglutição (61 pacientes). Foi observada incidência de disfagia em 76,5% dos pacientes avaliados clinicamente, este percentual elevando-se a 91% com avaliação videofluoroscópica. A alta incidência de disfagia observada neste estudo que avaliou pacientes com amplo espectro de gravidade, em diferentes fases de recuperação, ressalta a importância de equipe multidisciplinar, incluindo fonoaudiólogos capacitados, para avaliar os distúrbios da deglutição nos diversos momentos de recuperação dos AVEs.
Resumo:
Descreve-se um surto de abscesso mandibular em ovelhas da raça Bergamácia no município de Botucatu, estado de São Paulo. do rebanho de 120 animais, 35 apresentaram aumento de volume mandibular com a presença de nódulos únicos, de consistência pétrea, de diferentes tamanhos, fistulados ou não e sem indicativos de inflamação dos tecidos moles adjacentes. Os animais eram criados em pasto de Panicum maximum cv. Tanzânia com água e sal mineral ad libitum e everminados, via oral, com pistolas dosificadoras. O material para diagnóstico microbiológico e antibiograma foi coletado de cinco animais acometidos, por punção e aspiração dos nódulos. Dos 35 animais acometidos, 19 foram submetidos ao exame radiográfico, um ao exame tomográfico e outro à biópsia óssea da região submandibular. O único ovino que morreu, encontrava-se em estado de caquexia provavelmente devido à localização do aumento de volume que afetou a implantação dos dentes molares daquela região impedindo a apreensão e mastigação adequadas levando a perda da condição corporal e morte. Ao exame necroscópico, observaram-se áreas de necrose caseosa na mandíbula direita de onde isolou-se Pseudomonas aeruginosa. O tratamento utilizado foi baseado na aplicação de iodeto de sódio a 10% por via intramuscular e antibioticoterapia segundo antibiograma com enrofloxacina por via intramuscular, porém com pouca eficácia. Diante do quadro clínico, dos dados de anamnese, da localização das lesões no tecido ósseo mandibular, do resultado do cultivo microbiológico, das alterações radiográficas e tomográficas foi feito o diagnóstico de abscesso mandibular causado por Pseudomonas aeruginosa.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Diffuse large cell non Hodgkin's lymphoma associated with chronic lymphoid leukemia (CLL), or Richter's syndrome, is a rare and serious complication. Isolated Richter's syndrome in the central nervous system is very rare; only 12 cases have been reported. We describe a 74-year-old patient with diffuse large cell non Hodgkin's lymphoma in the right frontal region with the appearance of multiform glioblastoma.
Resumo:
Craniopharyngiomas and germ cell tumors (GCT) may affect the pituitary-hypothalamic region during childhood. Although different in origin, their clinical and radiological features may be similar. In this article we present a 5-year-old girl with clinical and radiological findings (computer tomography calcification) that were initially considered as craniopharyngioma. However clinical outcome, blood and cerebral spinal fluid tumoral markers, and results from anatomopathology and immunohistochemistry disclosed a mixed GCT. This case report highlights that some clinical features and radiological findings of pituitary-hypothalamic tumors may be misdiagnosed as craniopharyngioma mainly when there is a mature teratoma with cartilaginous tissue differentiation. Copyright© ABE&M.
Resumo:
Objective: To make individual assessments using automated quantification methodology in order to screen for perfusion abnormalities in cerebral SPECT examinations among a sample of subjects with OCD. Methods: Statistical parametric mapping (SPM) was used to compare 26 brain SPECT images from patients with OCD individually with an image bank of 32 normal subjects, using the statistical threshold of p < 0.05 (corrected for multiple comparisons at the level of individual voxels or clusters). The maps were analyzed, and regions presenting voxels that remained above this threshold were sought. results: Six patients from a sample of 26 OCD images showed abnormalities at cluster or voxel level, considering the criteria described above, which represented 23.07%. However, seven images from the normal group of 32 were also indicated as cases of perfusional abnormality, representing 21.8% of the sample. Conclusion: The automated quantification method was not considered to be a useful tool for clinical practice, for analyses complementary to visual inspection.
Resumo:
Background: Brain abscess of dental origin is a rare situation and deserves attention due to its high mortality rate even when adequate treatment is done. Few reports are available when dental origin is the main cause of this infection. Case report: We present the case of a 70-year-old man diagnosed with cerebral abscess caused by apical lesions located at superior and inferior teeth. The three lesions containing pus were drained from anterior and posterior brain region and the laboratory evaluation revealed the presence of Streptococcus viridians and Bacteroides. Postoperative period was uneventful with excellent recovery after 1 year of surgery. Final diagnosis was able to be done due to excellent image exams availability like computer tomography and magnetic resonance using diffusion and perfusion techniques. Discussion: The early detection of this pathology with the correct diagnosis essential to give the patient the best treatment including antimicrobial drugs and drainage is of extreme importance. © 2011 Springer-Verlag.