Technological development of fast multi-sectional, helical computed tomography (CT) scanners has allowed computed tomography perfusion (CTp) and angiography (CTA) in evaluating acute ischemic stroke. This study focuses on new multidetector computed tomography techniques, namely whole-brain and first-pass CT perfusion plus CTA of carotid arteries. Whole-brain CTp data is acquired during slow infusion of contrast material to achieve constant contrast concentration in the cerebral vasculature. From these data quantitative maps are constructed of perfused cerebral blood volume (pCBV). The probability curve of cerebral infarction as a function of normalized pCBV was determined in patients with acute ischemic stroke. Normalized pCBV, expressed as a percentage of contralateral normal brain pCBV, was determined in the infarction core and in regions just inside and outside the boundary between infarcted and noninfarcted brain. Corresponding probabilities of infarction were 0.99, 0.96, and 0.11, R² was 0.73, and differences in perfusion between core and inner and outer bands were highly significant. Thus a probability of infarction curve can help predict the likelihood of infarction as a function of percentage normalized pCBV. First-pass CT perfusion is based on continuous cine imaging over a selected brain area during a bolus injection of contrast. During its first passage, contrast material compartmentalizes in the intravascular space, resulting in transient tissue enhancement. Functional maps such as cerebral blood flow (CBF), and volume (CBV), and mean transit time (MTT) are then constructed. We compared the effects of three different iodine concentrations (300, 350, or 400 mg/mL) on peak enhancement of normal brain tissue and artery and vein, stratified by region-of-interest (ROI) location, in 102 patients within 3 hours of stroke onset. A monotonic increasing peak opacification was evident at all ROI locations, suggesting that CTp evaluation of patients with acute stroke is best performed with the highest available concentration of contrast agent. In another study we investigated whether lesion volumes on CBV, CBF, and MTT maps within 3 hours of stroke onset predict final infarct volume, and whether all these parameters are needed for triage to intravenous recombinant tissue plasminogen activator (IV-rtPA). The effect of IV-rtPA on the affected brain by measuring salvaged tissue volume in patients receiving IV-rtPA and in controls was investigated also. CBV lesion volume did not necessarily represent dead tissue. MTT lesion volume alone can serve to identify the upper size limit of the abnormally perfused brain, and those with IV-rtPA salvaged more brain than did controls. Carotid CTA was compared with carotid DSA in grading of stenosis in patients with stroke symptoms. In CTA, the grade of stenosis was determined by means of axial source and maximum intensity projection (MIP) images as well as a semiautomatic vessel analysis. CTA provides an adequate, less invasive alternative to conventional DSA, although tending to underestimate clinically relevant grades of stenosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Photoacoustic (PA) imaging of interphalangeal peripheral joints is of interest in the context of using the synovial membrane as a surrogate marker of rheumatoid arthritis. Previous work has shown that ultrasound (US) produced by absorption of light at the epidermis reflects on the bone surfaces within the finger. When the reflected signals are backprojected in the region of interest, artifacts are produced, confounding interpretation of the images. In this work, we present an approach where the PA signals known to originate from the epidermis are treated as virtual US transmitters, and a separate reconstruction is performed as in US reflection imaging. This allows us to identify the bone surfaces. Furthermore, the identification of the joint space is important as this provides a landmark to localize a region-of-interest in seeking the inflamed synovial membrane. The ability to delineate bone surfaces allows us to identify not only the artifacts but also the interphalangeal joint space without recourse to new US hardware or a new measurement. We test the approach on phantoms and on a healthy human finger.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of computed tomography systems with energy resolving detectors is a current challenge in medical physics and biomedical engineering. A computed tomography system of this kind allows getting complementary informations relatively to conventional systems, that can help the medical diagnosis, being of great interest in medicine. The work described in this thesis is related to the development of a computed tomography system using micropattern gaseous detectors, which allow storing, simultaneously, information about the interaction position and the energy of each single photon that interacts with the detector. This kind of detectors has other advantages concerning the cost and characteristics of operation when compared with solid state detectors. Tomographic acquisitions were performed using a MicroHole & Strip Plate based detector, which allowed reconstructing cross-sectional images using energy windows, applying the energy weighting technique and performing multi-slice and tri-dimensional reconstructions. The contrast-to-noise ratio was improved by 31% by applying the energy weighting technique, comparing with the corresponding image obtained with the current medical systems. A prototype of a computed tomography with flexibility to change the detector was developed, making it possible to apply different detectors based on Thick-COBRA. Several images acquired with these detectors are presented and demonstrate their applicability in X-ray imaging. When operating in NeCH4, the detector allowed a charge gain of 8 104, an energy resolution of 20% (full width at half maximum at 8 keV), a count rate of 1 106 Hz/mm2, a very stable operation (gain fluctuations below 5%) and a spacial resolution of 1.2 mm for an energy photon of 3.6 keV. Operating the detector in pure Kr allowed increasing the detection efficiency and achieving a charge gain of 2 104, an energy resolution of 32% (full width at half maximum at 22 keV), a count rate of 1 105 Hz/mm2, very stable operation and a spatial resolution of 500 m. The software already existing in the group was improved and tools to correct geometric misalignments of the system were also developed. The reconstructions obtained after geometrical correction are free of artefacts due to the referred misalignments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In an emergency department (ED), computed tomography (CT) is particularly beneficial in the investigation of high-speed trauma patients. With the advent of multidetector CT (MDCT) scanners, it is becoming faster and easier to conduct scans. In recent years, this has become evident with an increasing number of CT requests. Patients who have multiple CT scans during their hospital stay can receive radiation doses that have an increased theoretical risk of induction of cancer. It is essential that the clinical justification for each CT scan be considered on an individual basis and that due consideration is given to the radiation risk and possible diagnostic benefit. The current lack of a central State or Commonwealth data repository for medical images is a contributing factor to excessive radiation dosage to the population. The principles of justification and radiation risks are discussed in this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The surgical removal of impacted, supernumerary, or ectopic teeth is a routine procedure to the dental surgeon. Because any and all surgical interventions involve anatomic considerations that predispose the patient to a high risk of incidents or complications, it is absolutely necessary to precisely determine the location of the enclosed teeth, to better plan the procedure. Even though the conventional radiographic techniques are commonly used to detect the presence of such teeth, they can present deficiencies. In those situations, additional examinations can be requested. In this article, we are reporting the case of a 12-year-old patient, whose third superior molars appeared in a very atypical position. We chose to request a computed tomography and three-dimensional manipulation of the obtained images. This article, as its main goal, highlighted the importance of computed tomography and of three-dimensional reconstructions as a tool to precisely determine the location of enclosed teeth, thus allowing for a better planning of the surgery and a safer surgical intervention.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare dental plaster model (DPM) and cone-beam computed tomography (CBCT) in the measurement of the dental arches, and investigate whether CBCT image artifacts compromise the reliability of such measurements.Materials and Methods: Twenty patients were divided into two groups based on the presence or absence of metallic restorations in the posterior teeth. Both dental arches of the patients were scanned with the CBCT unit i-CAT, and DPMs were obtained. Two examiners obtained eight arch measurements on the CBCT images and DPMs and repeated this procedure 15 days later. The arch measurements of each patient group were compared separately by the Wilcoxon rank sum (Mann-Whitney U) test, with a significance level of 5% (alpha = .05). Intraclass correlation measured the level of intraobserver agreement.Results: Patients with healthy teeth showed no significant difference between all DPM and CBCT arch measurements (P > .05). Patients with metallic restoration showed significant difference between DPM and CBCT for the majority of the arch measurements (P > .05). The two examiners showed excellent intraobserver agreement for both measuring methods with intraclass correlation coefficient higher than 0.95.Conclusion: CBCT provided the same accuracy as DPM in the measurement of the dental arches, and was negatively influenced by the presence of image artifacts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Horizontal root fractures (HRF) usually affect the anterior teeth as a result of trauma, and generally heal spontaneously, depending on the vitality of the pulp. Diagnosis based on clinical findings, sensitivity tests, and radiographic examination is important to determine the presence of a root fracture and to prevent a root fracture from passing unnoticed. Cone-beam computed tomography (CBCT) has been used successfully for diagnosis and prognosis imaging of root fractures and has proved to be superior to other radiographic methods. This study reports two cases of dental trauma caused by a collision and a sports accident. The patients suffered horizontal root fractures in the maxillary left central incisor and in the mandibular left central incisor. The diagnosis of root fracture was confirmed by cone-beam computed tomography (CBCT) images, which also demonstrated spontaneous healing of the fracture line. The repair occurred by interposition of connective tissue in the former case and by interposition of bone and connective tissue in the latter case. The final diagnoses of both cases were based on CBCT images, indicating the importance of a CBCT examination to reach a firm diagnosis and to follow the healing process of root fracture cases, avoiding unnecessary radical endodontic treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contrast enhancement enables the verification of several pathological conditions that lead to vascular changes and/or breakdown of the blood-brain barrier. Examples of diseases that cause these disorders are: neoplastic diseases, vascular communications, active inflammation and cerebral ischemia. Several contrast enhancements located peripherically to cerebral lobes, in the topography of brain sulci and gyri, were identified on tomographic scan of twelve healthy cats that had their health confirmed through history, general and neurologic physical examination and polymerase chain reaction for feline leukemia (FeLV) and immunodeficiency (FIV) virus. This study aims to describe the tomographic contrast enhancement findings, which showed an identical appearance to the pia mater and arachnoid enhancement, also called leptomeninges. This finding is generally considered related to leptomeningeal diseases such as meningitis and neoplastic disease. However, in dogs, the leptomeningeal enhancement has already been described in healthy animals. This finding has a great importance in the interpretation of tomographic images of these animals since, so far, in the presence of these enhancements, meningeal disorders were suggested. Thus, the verification of other tomographic findings and the combination with other diagnostic methods are of great importance for the diagnosis of leptomeningeal disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The head is the most important and specialized region in the body because it contains a range of specialized organs and, because it has interconnections between specialized organs, there is a great overlap of images. Thus, computed tomography (CT) helps in diagnosing diseases in this region, such as oral conditions, as they provide millimetric slices or cuts and demonstrate the relationship between the various anatomical structures involved, in volume and depth. Within dentistry, CT helps in the identification of pathological processes such as infection, tumors, visualization of embedded teeth and bone bed. This study aimed to assess the density of the mandibular alveolar bone at a determined point to later predict how periodontal disease is involved in bone resorption. For this, we performed a blind retrospective study (n = 124) of the CT scan files of dog skulls at FMVZ-UNESP in order to determine the density of the jaw bone using a Hounsfield scale, in the region of the dental apex of the cranial root of the first molar tooth in dogs. The results obtained were evaluated using mean and standard deviation (27.28 +/- 9.53 HU) in order to predict the normal density of the mandibular alveolar bone in the studied region. Thus, this data analysis allows a more concise evaluation of bone resorption of mandibular alveolar bone and, therefore, provides an adequate surgical planning in cases of osteosynthesis given mainly by the presence of installed periodontal disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) for measuring the buccal bone volume around dental implants. Materials and methods: Three to six implants were inserted into the anterior maxilla of eight skulls, depending on the availability of bone, and after this, the CBCT was performed. By means of CBCT image, measurements of the bone wall at three points of the implant were obtained, analyzed and compared with those obtained in the plaster skull casting. Results: The results showed that for the three points of the implants, no statistically significant difference in the measurements was obtained from the plaster model and CBCT images. Conclusions: CBCT can be a useful tool for assessing buccal bone volume along the implant. To cite this article:?Shiratori LN, Marotti J, Yamanouchi J, Chilvarquer I, Contin I, Tortamano-Neto P. Measurement of buccal bone volume of dental implants by means of cone-beam computed tomography.?Clin. Oral Impl. Res. 23, 2012; 797804.?doi: 10.1111/j.1600-0501.2011.02207.x

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Owing to a lack of symptoms and difficult visualization in routine intraoral radiographs, diagnosis of external root resorptions can be challenging. Aim: The goal of this study was to compare two image acquisition methods, intraoral radiographs and cone beam computed tomography (CBCT), in the diagnosis of external resorption. Material and Methods: Thirty-four maxillary and mandibular bicuspids were divided into three groups. Perforations measuring 0.3 and 0.6 mm in diameter and 0.15 and 0.3 mm in depth, respectively, were made on the lingual root surfaces in thirty teeth, and four were used as controls. Next, teeth were mounted on an apparatus and radiographed at mesial, distal, and orthoradial angulations. CBCT images were also taken. The analysis of the intraoral radiographic and tomographic images was carried out by two experts using standardized scores. Data were then compared statistically. Results: A strong agreement between the examiners was observed in both diagnosis methods, the intraoral radiographic (r = 0.93) and the tomographic analysis (r = 1.0). Tomography had higher statistically significant detection values than intraoral radiography (P < 0.05). In intraoral radiographs, the detection was significantly greater (P < 0.05) in the mandibular bicuspids, compared with their maxillary counterparts. The ability to detect 0.6-mm perforations by intraoral radiography was significantly higher than that of 0.3-mm perforations (P < 0.05). Conclusion: Cone beam computed tomography showed better diagnostic ability compared with intraoral radiography, regardless of the tooth or the dimensions of the resorption evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare two methods of assessing apical transportation in curved canals after rotary instrumentation, namely, cross-sections and micro-computed tomography (mu CT). Thirty mandibular molars were divided into two groups and prepared according to the requirements of each method. In G1 (cross-sections), teeth were embedded in resin blocks and sectioned at 2.0, 3.5, and 5.0 mm from the anatomic apex. Pre- and postoperative sections were photographed and analyzed. In G2 (mu CT), teeth were embedded in a rubber-base impression material and scanned before and after instrumentation. Mesiobuccal canals were instrumented with the Twisted File (TF) system (SybronEndo, Orange, USA), and mesiolingual canals, with the Endo Sequence (ES) system (Brasseler, Savannah, USA). Images were reconstructed, and sections corresponding to distances 2.0, 3.5, and 5.0 mm from the anatomic apex were selected for comparison. Data were analyzed using Mann-Whitney's test at a 5% significance level. The TF and ES instruments produced little deviation from the root canal center, with no statistical difference between them (P > 0.05). The canal transportation results were significantly lower (0.056 mm) in G2 than in G1 (0.089 mm) (p = 0.0012). The mu CT method was superior to the cross-section method, especially in view of its ability to preserve specimens and provide results that are more closely related to clinical situations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Cone-beam computed tomography (CBCT) is a reliable method of assessing the oral cavity and upper airways. We conducted this study to examine the changes introduced by rapid maxillary expansion in the nasal cavity, nasopharynx, and oropharynx as seen with images obtained by CBCT. Materials and Methods: We evaluated 15 patients with maxillary width deficiency treated with RME. Patients were subjected to CBCT at the beginning of RME and after the retention period of 4 months. Results: The nasal cavity presented a significant transverse increase in the lower third, in the anterior (1.08 mm +/- 0.15), medium (1.28 mm +/- 0.15), and posterior regions (0.77 mm +/- 0.12). No significant change occurred in the nasopharynx in volume (P = .11), median sagittal area (P = .33), or lower axial area (P = .29) resulting from the RME. A significant change was noted in the oropharynx in volume (P = .05), median sagittal area (P = .01), and lower axial area (P = .04) before and immediately after the RME. Conclusions: RME is able to increase the transverse width of the nasal cavity, but it does not have the same effect in the nasopharynx. Changes noted in the oropharynx may be due to the lack of a standardized position of the head and tongue at the time of image acquisition. (Angle Orthod. 2012;82:458-463.)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To verify the thickness and level of alveolar bone around the teeth adjacent to the cleft by means of cone beam computed tomography (CBCT) in patients with complete bilateral cleft lip and palate prior to bone graft surgery and orthodontic intervention. Method: The sample comprised 10 patients with complete bilateral cleft lip and palate (five boys and five girls) in the mixed dentition. The mean age was 9.5 years, and all subjects showed a G3 interarch relationship according to the Bauru index. The thickness of alveolar bone surrounding the maxillary incisors and the maxillary canines was measured in CBCT axial section using the software iCAT Xoran System. The distance between the alveolar bone crest and the cement-enamel junction (CEJ) was measured in cross sections. Results: The tomography images showed a thin alveolar bone plate around teeth adjacent to clefts. No bone dehiscence was observed in teeth adjacent to clefts during the mixed dentition. A slight increase in the distance between the alveolar bone crest and the CEJ was observed in the mesial and lingual aspects of canines adjacent to cleft. Conclusion: In patients with BCLP in the mixed dentition, teeth adjacent to the alveolar cleft are covered by a thin alveolar bone plate. However, the level of alveolar bone crest around these teeth seems to be normal, and no bone dehiscence was identified at this age.