43 resultados para collimation
Resumo:
PURPOSE: We investigated the influence of beam modulation on treatment planning by comparing four available stereotactic radiosurgery (SRS) modalities: Gamma-Knife-Perfexion, Novalis-Tx Dynamic-Conformal-Arc (DCA) and Dynamic-Multileaf-Collimation-Intensity-Modulated-radiotherapy (DMLC-IMRT), and Cyberknife. MATERIAL AND METHODS: Patients with arteriovenous malformation (n = 10) or acoustic neuromas (n = 5) were planned with different treatment modalities. Paddick conformity index (CI), dose heterogeneity (DH), gradient index (GI) and beam-on time were used as dosimetric indices. RESULTS: Gamma-Knife-Perfexion can achieve high degree of conformity (CI = 0.77 ± 0.04) with limited low-doses (GI = 2.59 ± 0.10) surrounding the inhomogeneous dose distribution (D(H) = 0.84 ± 0.05) at the cost of treatment time (68.1 min ± 27.5). Novalis-Tx-DCA improved this inhomogeneity (D(H) = 0.30 ± 0.03) and treatment time (16.8 min ± 2.2) at the cost of conformity (CI = 0.66 ± 0.04) and Novalis-TX-DMLC-IMRT improved the DCA CI (CI = 0.68 ± 0.04) and inhomogeneity (D(H) = 0.18 ± 0.05) at the cost of low-doses (GI = 3.94 ± 0.92) and treatment time (21.7 min ± 3.4) (p<0.01). Cyberknife achieved comparable conformity (CI = 0.77 ± 0.06) at the cost of low-doses (GI = 3.48 ± 0.47) surrounding the homogeneous (D(H) = 0.22 ± 0.02) dose distribution and treatment time (28.4min±8.1) (p<0.01). CONCLUSIONS: Gamma-Knife-Perfexion will comply with all SRS constraints (high conformity while minimizing low-dose spread). Multiple focal entries (Gamma-Knife-Perfexion and Cyberknife) will achieve better conformity than High-Definition-MLC of Novalis-Tx at the cost of treatment time. Non-isocentric beams (Cyberknife) or IMRT-beams (Novalis-Tx-DMLC-IMRT) will spread more low-dose than multiple isocenters (Gamma-Knife-Perfexion) or dynamic arcs (Novalis-Tx-DCA). Inverse planning and modulated fluences (Novalis-Tx-DMLC-IMRT and CyberKnife) will deliver the most homogeneous treatment. Furthermore, Linac-based systems (Novalis and Cyberknife) can perform image verification at the time of treatment delivery.
Resumo:
Messages à retenir: La scanographie hélicoïdale à collimation fine sur l'ensemble du thorax est l'examen de référence pour le diagnostic et l'évaluation de la distributiontopographique et de l'étendue des bronchectasies.Les reformations multiplanaires et les techniques de projection d'intensité maximum et minimum améliorent les performances diagnostiques et permettent unemeilleure détection des lésions associées des petites voies aériennes (bronchiolite infectieuse, bronchiolite oblitérative).Chez les patients atteints de bronchectasies, le degré d'épaississement pariétal bronchique ainsi que l'étendue des zones hypodenses hypoperfusées traduisantdes lésions d'obstruction bronchiolaire sont parfaitement corrélés à la sévérité du retentissement fonctionnel de la maladie .La scanographie est peu fiable pour reconnaître le diagnostic étiologique des bronchectasies. Résumé: La scanographie hélicoïdale multidétecteur à collimation fine sur l'ensemble du thorax au cours d'une seule et même apnée inspiratoire est supérieure auxexamens en coupes fines incrémentales haute résolution avec un intervalle de coupes de 10 mm, pour le diagnostic et l'évaluation de l'étendue desbronchectasies. L'usage des reformations multiplanaires améliore la détection des bronchectasies, augmente la reproductibilité des radiologues pour lediagnostic des bronchectasies ainsi que leur niveau de confiance pour apprécier la distribution lésionnelle . L'examen scanographique évalue le nombre et ladistribution des impactions mucoïdes dans des bronches dilatées et le retentissement de l'atteinte bronchique sur les voies aériennes distales et le parenchymepulmonaire. La recherche d'atteinte associée des petites voies aériennes est systématique : détection des foyers de bronchiolite infectieuse et évaluation de l'étendue des zones hypodenses, hypoperfusées, avec piégeage, qui reflètent les lésions de bronchiolite oblitérative . Ces dernières sont corrélées au degré desévérité de l'obstruction fonctionnelle. La scanographie reste peu fiable pour le diagnostic étiologique des bronchectasies. Inversement, certains mécanismessont facilement identifiés, tels que les bronchectasies post-obstructives et les bronchectasies par traction des fibroses pulmonaires .
Resumo:
Le traitement de radiochirurgie par Gamma Knife (GK) est utilisé de plus en plus souvent comme une alternative à la microchirurgie conventionnelle pour le traitement des pathologies neurochirurgicales intracrâniennes. Il s'agit d'irradier en dose unique et à haute énergie, en condition stéréotaxique et à l'aide d'une imagerie multimodale (imagerie par résonance magnétique [IRM], tomodensitométrie et éventuellement artériographie). Le GK a été inventé par le neurochirurgien suédois Lars Leksell, qui a réalisé le premier ciblage du nerf trijumeau en 1951, sur la base d'une radiographie standard. Depuis, les progrès de l'informatique et de la robotique ont permis d'améliorer la technique de radiochirurgie qui s'effectue actuellement soit par accélérateur linéaire de particules monté sur un bras robotisé (Novalis®, Cyberknife®), soit par collimation de près de 192 sources fixes (GK). La principale indication radiochirurgicale dans le traitement de la douleur est la névralgie du nerf trijumeau. Les autres indications, plus rares, sont la névralgie du nerf glossopharyngien, l'algie vasculaire de la face, ainsi qu'un traitement de la douleur d'origine cancéreuse par hypophysiolyse. Gamma Knife surgery (GKS) is widely used as an alternative to open microsurgical procedures as noninvasive treatment of many intracranial conditions. It consists of delivering a single dose of high energy in stereotactic conditions, and with the help of a multimodal imaging (e.g., magnetic resonance imaging [MRI], computer tomography, and eventually angiography). The Gamma Knife (GK) was invented by the Swedish neurosurgeon Lars Leksell who was the first to treat a trigeminal neuralgia sufferer in 1951 using an orthogonal X-ray tube. Since then, the progresses made both in the field of informatics and robotics have allowed to improve the radiosurgical technique, which is currently performed either by a linear accelerator of particles mounted on a robotized arm (Novalis®, Cyberknife®), or by collimation of 192 fixed Co-60 sources (GK). The main indication of GKS in the treatment of pain is trigeminal neuralgia. The other indications, less frequent, are: glossopharyngeal neuralgia, cluster headache, and hypophysiolyse for cancer pain.
Resumo:
We describe in this article the application of a high-density gas aggregation nanoparticle gun to the production and characterization of high anisotropy SmCo nanoparticles. We give a detailed description of the simple but efficient experimental apparatus with a focus on the microscopic processes of the gas aggregation technique. Using high values of gas flux (similar to 45 sccm) we are able to operate in regimes of high collimation of material. In this regime, as we explain in terms of a phenomenological model, the power applied to the sputtering target becomes the main variable to change the size of the clusters. Also presented are the morphological, structural, and magnetic characterizations of SmCo nanoparticles produced using 10 and 50 W of sputtering power. These values resulted in mean sizes of similar to 12 and similar to 20 nm. Significant differences are seen in the structural and magnetic properties of the samples with the 50 W sample showing a largely enhanced crystalline structure and magnetic anisotropy.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Shearplate is an optical glass plate having two flat surfaces and a small angle between them. The use of a high quality shear plate is essential to implement shear interferometric technique . The shear interferometry is a technique used to evaluate the light beam collimation. In order to guarantee the shearplate quality , the complete manufacturing process must be thoroughly monitored. In the manufacturing process, the first step consisted of the glass selection. The selected glass has been submitted to the process of cutting, gluing, chamfering, grinding and polishing. Each phase has been strictly monitored. The quality of the final result depends extremely on an appropriate starting condition, which arises from the grinding process, as the polishing process only recovers the brightness of the part, acting on a small scale on the wearing off of the part, as well as not changing the structured obtained in the grinding process. Respecting all stages of the manufacturing process, the quality of the part has evolved to a good result. The best result obtained showed PV distance of 162 nm, slightly less than λ / 4. This result is significant because the dimensions of the piece with respect to the dimensions of the polisher what interferes directly in the results. The closer are the dimensions of piece and the dimensions of the polisher, the greater the difficulty in controlling the propagation of errors
Resumo:
Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)
Resumo:
The rapid technical advances in computed tomography have led to an increased number of clinical indications. Unfortunately, at the same time the radiation exposure to the population has also increased due to the increased total number of CT examinations. In the last few years various publications have demonstrated the feasibility of radiation dose reduction for CT examinations with no compromise in image quality and loss in interpretation accuracy. The majority of the proposed methods for dose optimization are easy to apply and are independent of the detector array configuration. This article reviews indication-dependent principles (e.g. application of reduced tube voltage for CT angiography, selection of the collimation and the pitch, reducing the total number of imaging series, lowering the tube voltage and tube current for non-contrast CT scans), manufacturer-dependent principles (e.g. accurate application of automatic modulation of tube current, use of adaptive image noise filter and use of iterative image reconstruction) and general principles (e.g. appropriate patient-centering in the gantry, avoiding over-ranging of the CT scan, lowering the tube voltage and tube current for survey CT scans) which lead to radiation dose reduction.
Resumo:
BACKGROUND: Integrity of the abdominal aortic aneurysm (AAA) neck is crucial for the long-term success of endovascular AAA repair (EVAR). However, suitable tools for reliable assessment of changes in small aortic volumes are lacking. The purpose of this study was to assess the intraobserver and interobserver variability of software-enhanced 64-row computed tomographic angiography (CTA) AAA neck volume measurements in patients after EVAR. METHODS: A total of 25 consecutive patients successfully treated by EVAR underwent 64-row follow-up CTA in 1.5-mm collimation. Manual CTA measurements were performed twice by three blinded and independent readers in random order with at least a 4-week interval between readings. Maximum and minimum transverse aortic neck diameters were measured twice on two different levels within the proximal neck. Volumetry of the proximal aortic neck was performed by using dedicated software. Variability was calculated as 1.96 SD of the mean arithmetic difference according to Bland and Altman. Two-sided and paired t tests were used to compare measurements. P values <.05 were considered to indicate statistical significance. RESULTS: Intraobserver agreement was excellent for dedicated aneurysmal neck volumetry, with mean differences of less than 1 mL (P > .05), whereas it was poor for transverse aortic neck diameter measurements (P < .05). However, interobserver variability was statistically significant for both neck volumetry (P < .005) and neck diameter measurements (P < .015). CONCLUSIONS: The reliability of dedicated AAA neck volumetry by using 64-row CTA is excellent for serial measurements by individual readers, but not between different readers. Therefore, studies should be performed with aortic neck volumetry by a single experienced reader.
Resumo:
BACKGROUND: Until August 2004 there were 106 forensic cases examined with postmortem multislice computed tomography (MSCT) and magnetic resonance (MR) imaging before traditional autopsy within the Virtopsy project. Intrahepatic gas (IHG) was a frequent finding in postmortem MSCT examinations. The aim of this study was to investigate its cause and significance. METHODS: There were 84 virtopsy cases retrospectively investigated concerning the occurrence, location, and volume of IHG in postmortem MSCT imaging (1.25 mm collimation, 1.25 mm thickness). We assessed and noted the occurrence of intestinal distention, putrefaction, and systemic gas embolisms and the cause of death, possible open trauma, possible artificial respiration, and the postmortem interval. We investigated the relations between the findings using the contingency table (chi2 test) and the comparison of the postmortem intervals in both groups was performed using the t test in 79 nonputrefied corpses. RESULTS: IHG was found in 47 cases (59.5%). In five of the cases, the IHG was caused or influenced by putrefaction. Gas distribution within the liver of the remaining 42 cases was as follows: hepatic arteries in 21 cases, hepatic veins in 35 cases, and portal vein branches in 13 cases; among which combinations also occurred in 20 cases. The presence of IHG was strongly related to open trauma with systemic gas. Pulmonary barotrauma as occurring under artificial respiration or in drowning also caused IHG. Putrefaction did not seem to influence the occurrence of IHG until macroscopic signs of putrefaction were noticeable. CONCLUSIONS: IHG is a frequent finding in traumatic causes of death and requires a systemic gas embolism. Exceptions are putrefied or burned corpses. Common clinical causes such as necrotic bowel diseases appear rarely as a cause of IHG in our forensic case material.
Resumo:
PURPOSE: To quantify the interobserver variability of abdominal aortic aneurysm (AAA) neck length and angulation measurements. MATERIALS AND METHODS: A total of 25 consecutive patients scheduled for endovascular AAA repair underwent follow-up 64-row computed tomographic (CT) angiography in 0.625-mm collimation. AAA neck length and angulation were determined by four blinded, independent readers. AAA neck length was defined as the longitudinal distance between the first transverse CT slice directly distal to the lowermost renal artery and the first transverse CT slice that showed at least a 15% larger outer aortic wall diameter versus the diameter measured directly below the lowermost renal artery. Infrarenal AAA neck angulation was defined as the true angle between the longitudinal axis of the proximal AAA neck and the longitudinal axis of the AAA lumen as analyzed on three-dimensional CT reconstructions. RESULTS: Mean deviation in aortic neck length determination was 32.3% and that in aortic neck angulation was 32.1%. Interobserver variability of aortic neck length and angulation measurements was considerable: in any reader combination, at least one measurement difference was outside the predefined limits of agreement. CONCLUSIONS: Assessment of the longitudinal extension and angulation of the infrarenal aortic neck is associated with substantial observer variability, even if measurement is carried out according to a standardized protocol. Further studies are mandatory to assess dedicated technical approaches to minimize variance in the determination of the longitudinal extension and angulation of the infrarenal aortic neck.
Resumo:
Refractive losses in laser-produced plasmas used as gain media are caused by electron density gradients, and limit the energy transport range. The pump pulse is thus deflected from the high-gain region and the short wavelength laser signal also steers away, causing loss of collimation. A Hohlraum used as a target makes the plasma homogeneous and can mitigate refractive losses by means of wave-guiding. A computational study combining a hydrodynamics code and an atomic physics code is presented, which includes a ray-tracing modeling based on the eikonal theory of the trajectory equation. This study presents gain calculations based on population inversion produced by free-electron collisions exciting bound electrons into metastable levels in the 3d94d1(J = 0) → 3d94p1(J = 1) transition of Ni-like Sn. Further, the Hohlraum suggests a dramatic enhancement of the conversion efficiency of collisionally excited x-ray lasing for Ni-like Sn.
Resumo:
High brightness electron sources are of great importance for the operation of the hard X-ray free electron lasers. Field emission cathodes based on the double-gate metallic field emitter arrays (FEAs) can potentially offer higher brightness than the currently used ones. We report on the successful application of electron beam lithography for fabrication of the large-scale single-gate as well as double-gate FEAs. We demonstrate operational high-density single-gate FEAs with sub-micron pitch and total number of tips up to 106 as well as large-scale double-gate FEAs with large collimation gate apertures. The details of design, fabrication procedure and successful measurements of the emission current from the single- and double-gate cathodes are presented.
Resumo:
BACKGROUND A precise detection of volume change allows for better estimating the biological behavior of the lung nodules. Postprocessing tools with automated detection, segmentation, and volumetric analysis of lung nodules may expedite radiological processes and give additional confidence to the radiologists. PURPOSE To compare two different postprocessing software algorithms (LMS Lung, Median Technologies; LungCARE®, Siemens) in CT volumetric measurement and to analyze the effect of soft (B30) and hard reconstruction filter (B70) on automated volume measurement. MATERIAL AND METHODS Between January 2010 and April 2010, 45 patients with a total of 113 pulmonary nodules were included. The CT exam was performed on a 64-row multidetector CT scanner (Somatom Sensation, Siemens, Erlangen, Germany) with the following parameters: collimation, 24x1.2 mm; pitch, 1.15; voltage, 120 kVp; reference tube current-time, 100 mAs. Automated volumetric measurement of each lung nodule was performed with the two different postprocessing algorithms based on two reconstruction filters (B30 and B70). The average relative volume measurement difference (VME%) and the limits of agreement between two methods were used for comparison. RESULTS At soft reconstruction filters the LMS system produced mean nodule volumes that were 34.1% (P < 0.0001) larger than those by LungCARE® system. The VME% was 42.2% with a limit of agreement between -53.9% and 138.4%.The volume measurement with soft filters (B30) was significantly larger than with hard filters (B70); 11.2% for LMS and 1.6% for LungCARE®, respectively (both with P < 0.05). LMS measured greater volumes with both filters, 13.6% for soft and 3.8% for hard filters, respectively (P < 0.01 and P > 0.05). CONCLUSION There is a substantial inter-software (LMS/LungCARE®) as well as intra-software variability (B30/B70) in lung nodule volume measurement; therefore, it is mandatory to use the same equipment with the same reconstruction filter for the follow-up of lung nodule volume.
Resumo:
PURPOSE To investigate whether the effects of hybrid iterative reconstruction (HIR) on coronary artery calcium (CAC) measurements using the Agatston score lead to changes in assignment of patients to cardiovascular risk groups compared to filtered back projection (FBP). MATERIALS AND METHODS 68 patients (mean age 61.5 years; 48 male; 20 female) underwent prospectively ECG-gated, non-enhanced, cardiac 256-MSCT for coronary calcium scoring. Scanning parameters were as follows: Tube voltage, 120 kV; Mean tube current time-product 63.67 mAs (50 - 150 mAs); collimation, 2 × 128 × 0.625 mm. Images were reconstructed with FBP and with HIR at all levels (L1 to L7). Two independent readers measured Agatston scores of all reconstructions and assigned patients to cardiovascular risk groups. Scores of HIR and FBP reconstructions were correlated (Spearman). Interobserver agreement and variability was assessed with ĸ-statistics and Bland-Altmann-Plots. RESULTS Agatston scores of HIR reconstructions were closely correlated with FBP reconstructions (L1, R = 0.9996; L2, R = 0.9995; L3, R = 0.9991; L4, R = 0.986; L5, R = 0.9986; L6, R = 0.9987; and L7, R = 0.9986). In comparison to FBP, HIR led to reduced Agatston scores between 97 % (L1) and 87.4 % (L7) of the FBP values. Using HIR iterations L1 - L3, all patients were assigned to identical risk groups as after FPB reconstruction. In 5.4 % of patients the risk group after HIR with the maximum iteration level was different from the group after FBP reconstruction. CONCLUSION There was an excellent correlation of Agatston scores after HIR and FBP with identical risk group assignment at levels 1 - 3 for all patients. Hence it appears that the application of HIR in routine calcium scoring does not entail any disadvantages. Thus, future studies are needed to demonstrate whether HIR is a reliable method for reducing radiation dose in coronary calcium scoring.