965 resultados para central venous pressure
Resumo:
OBJECTIVE: Transthoracic echocardiography (TTE) has been used clinically to disobstruct venous drainage cannula and to optimise placement of venous cannulae in the vena cava but it has never been used to evaluate performance capabilities. Also, little progress has been made in venous cannula design in order to optimise venous return to the heart lung machine. We designed a self-expandable Smartcanula (SC) and analysed its performance capability using echocardiography. METHODS: An epicardial echocardiography probe was placed over the SC or control cannula (CTRL) and a Doppler image was obtained. Mean (V(m)) and maximum (V(max)) velocities, flow and diameter were obtained. Also, pressure drop (DeltaP(CPB)) was obtained between the central venous pressure and inlet to venous reservoir. LDH and Free Hb were also compared in 30 patients. Comparison was made between the two groups using the student's t-test with statistical significance established when p<0.05. RESULTS: Age for the SC and CC groups were 61.6+/-17.6 years and 64.6+/-13.1 years, respectively. Weight was 70.3+/-11.6 kg and 72.8+/-14.4 kg, respectively. BSA was 1.80+/-0.2 m(2) and 1.82+/-0.2 m(2), respectively. CPB times were 114+/-53 min and 108+/-44 min, respectively. Cross-clamp time was 59+/-15 min and 76+/-29 min, respectively (p=NS). Free-Hb was 568+/-142 U/l versus 549+/-271 U/l post-CPB for the SC and CC, respectively (p=NS). LDH was 335+/-73 mg/l versus 354+/-116 mg/l for the SC and CC, respectively (p=NS). V(m) was 89+/-10 cm/s (SC) versus 63+/-3 cm/s (CC), V(max) was 139+/-23 cm/s (SC) versus 93+/-11 cm/s (CC) (both p<0.01). DeltaP(CPB) was 30+/-10 mmHg (SC) versus 43+/-13 mmHg (CC) (p<0.05). A Bland-Altman test showed good agreement between the two devices used concerning flow rate calculations between CPB and TTE (bias 300 ml+/-700 ml standard deviation). CONCLUSIONS: This novel Smartcanula design, due to its self-expanding principle, provides superior flow characteristics compared to classic two stage venous cannula used for adult CPB surgery. No detrimental effects were observed concerning blood damage. Echocardiography was effective in analysing venous cannula performance and velocity patterns.
Resumo:
OBJECTIVE: To investigate the hemodynamic effects of L-canavanine (an inhibitor of inducible, but not of constitutive, nitric oxide synthase) in endotoxic shock. DESIGN: Controlled, randomized, experimental study. SETTING: Animal laboratory. SUBJECTS: Wistar rats. INTERVENTIONS: Rats were anesthetized with pentobarbital, and hemodynamically monitored. One hour after an intravenous challenge with 5 mg/kg of Escherichia coli endotoxin, the rats were randomized to receive a continuous infusion of either L-canavanine (20 mg/kg/hr; n = 8) or vehicle only (isotonic saline, n = 11). In all animals, the infusion was given over 5 hrs at a rate of 2 mL/kg/hr. These experiments were repeated in additional rats challenged with isotonic saline instead of endotoxin (sham experiments). MEASUREMENTS AND MAIN RESULTS: Arterial blood pressure, heart rate, thermodilution cardiac output, central venous pressure, mean systemic filling pressure, urine output, arterial blood gases, blood lactate concentration, and hematocrit were measured. In sham experiments, hemodynamic stability was maintained throughout and L-canavanine had no detectable effect. Animals challenged with endotoxin and not treated with L-canavanine developed progressive hypotension and low cardiac output. After 6 hrs of endotoxemia, both central venous pressure and mean systemic filling pressure were significantly below their baseline values, indicating relative hypovolemia as the main determinant of reduced cardiac output. In endotoxemic animals treated with L-canavanine, hypotension was less marked, while cardiac output, central venous pressure, and mean systemic filling pressure were maintained throughout the experiment. L-canavanine had no effect on the time-course of hematocrit. L-canavanine significantly increased urine output and reduced the severity of lactic acidosis. CONCLUSIONS: Six hours after an endotoxin challenge in rats, low cardiac output develops, which appears to be primarily related to relative hypovolemia. L-canavanine, a selective inhibitor of the inducible nitric oxide synthase, increases the mean systemic filling pressure, thereby improving venous return, under these conditions.
Resumo:
Abstract OBJECTIVE Determining which is the most effective solution (heparin flush compared to 0.9% saline flush) for reducing the risk of occlusions in central venous catheters (CVC) in adults. METHOD The systematic review followed the principles proposed by the Cochrane Handbook; critical analysis, extraction and synthesis of data were performed by two independent researchers; statistical analysis was performed using the RevMan program 5.2.8. RESULTS Eight randomized controlled trials and one cohort study were included and the results of the meta-analysis showed no difference (RR=0.68, 95% CI=0.41-1.10; p=0.12). Analysis by subgroups showed that there was no difference in fully deployed CVC (RR=1.09, CI 95%=0.53-2.22;p=0.82); Multi-Lumen CVC showed beneficial effects in the heparin group (RR=0.53, CI 95%=0.29-0.95; p=0.03); in Double-Lumen CVC for hemodialysis (RR=1.18, CI 95%=0.08-17.82;p=0.90) and Peripherally inserted CVC (RR=0.14, CI 95%=0.01-2.60; p=0.19) also showed no difference. CONCLUSION Saline solution is sufficient for maintaining patency of the central venous catheter, preventing the risks associated with heparin administration.
Resumo:
Peripheral venous cannulation is the preferred method of inserting central venous silastic catheters in premature infants. The standard techniques are placement of the catheter using a breakaway introducer needle or introduction of the catheter through a cannula. In extremely low birth weight infants (<1000 g) successful cannulation is impeded by the small size of the vessels. After repeated attempts, both procedures can be time-consuming and stressful to the infant. We present a modified insertion technique of the standard 2-French silastic catheter with an increased success rate, thus reducing insertion time, stress to the infant, and costs. The method uses the tip of a 20-gauge cannula as dilator/introducer for the 2-French catheter. This tip is inserted into the vessel with a standard 24-gauge cannula. After successful insertion of the dilator/introducer cannula, the standard 2-French catheter can then be advanced easily.
Resumo:
La pose d'un cathéter veineux central est un geste fréquent dans un service de médecine interne. En suivant la formation des médecins-assistants, nous nous sommes aperçus que certaines questions, doutes ou craintes concernant cette procédure nous sont régulièrement adressées: «Est-ce qu'un cathéter sous-clavier peut être posé avec une thrombocytopénie modérée?»; «Quel site de ponction présente le moins de risques pour le patient?»; «Après combien de jours un cathéter doit-il être changé?». Cet article se propose de répondre à ces questions et à d'autres, en partant d'une mini-revue de la littérature actuelle. Central venous catheterization is a frequently performed procedure in internal medicine units. Residents in training frequently share the same questions, doubts and fears about this procedure : "Should I perform a subclavian catheterization in a patient with mild thrombopenia?"; "Which site has the lesser complication rate?"; "After how long does a catheter need to be replaced?". This mini-review of the current literature tries to answer this and other questions
Resumo:
Alteplase has been shown to be effective in preventing central venous access clotting in patients on hemodialysis. Because of a high phosphorus content in its excipient, it can inadvertently contaminate blood samples, leading the physician in care of the patient to erroneously increase dialysis time or change diet in order to control the pseudo-hyperphosphatemia.
Resumo:
BACKGROUND AND OBJECTIVE: Arterial base excess and lactate levels are key parameters in the assessment of critically ill patients. The use of venous blood gas analysis may be of clinical interest when no arterial blood is available initially. METHODS: Twenty-four pigs underwent progressive normovolaemic haemodilution and subsequent progressive haemorrhage until the death of the animal. Base excess and lactate levels were determined from arterial and central venous blood after each step. In addition, base excess was calculated by the Van Slyke equation modified by Zander (BE(z)). Continuous variables were summarized as mean +/- SD and represent all measurements (n = 195). RESULTS: Base excess according to National Committee for Clinical Laboratory Standards for arterial blood was 2.27 +/- 4.12 versus 2.48 +/- 4.33 mmol(-l) for central venous blood (P = 0.099) with a strong correlation (r(2) = 0.960, P < 0.001). Standard deviation of the differences between these parameters (SD-DIFBE) did not increase (P = 0.355) during haemorrhage as compared with haemodilution. Arterial lactate was 2.66 +/- 3.23 versus 2.71 +/- 2.80 mmol(-l) in central venous blood (P = 0.330) with a strong correlation (r(2) = 0.983, P < 0.001). SD-DIFLAC increased (P < 0.001) during haemorrhage. BE(z) for central venous blood was 2.22 +/- 4.62 mmol(-l) (P = 0.006 versus arterial base excess according to National Committee for Clinical Laboratory Standards) with strong correlation (r(2) = 0.942, P < 0.001). SD-DIFBE(z)/base excess increased (P < 0.024) during haemorrhage. CONCLUSION: Central venous blood gas analysis is a good predictor for base excess and lactate in arterial blood in steady-state conditions. However, the variation between arterial and central venous lactate increases during haemorrhage. The modification of the Van Slyke equation by Zander did not improve the agreement between central venous and arterial base excess.
Resumo:
Chronic hepatitis C is a major healthcare problem. The response to antiviral therapy for patients with chronic hepatitis C has previously been defined biochemically and by PCR. However, changes in the hepatic venous pressure gradient (HVPG) may be considered as an adjunctive end point for the therapeutic evaluation of antiviral therapy in chronic hepatitis C. It is a validated technique which is safe, well tolerated, well established, and reproducible. Serial HVPG measurements may be the best way to evaluate response to therapy in chronic hepatitis C.
Resumo:
OBJECTIVES: To assess the performance of 45F vs. 36F smartcanula in CPB with gravity drainage alone. METHODS: Twenty patients were randomly assigned to two groups receiving for venous drainage a smartcanula which is collapsed over a mandrel for trans-atrial insertion into the inferior vena cava and expanded in situ to either 45F or 36F. RESULTS: Valve replacement/repair was realized in 7/10 and/or CABG in 6/10 for 36F (69+/-13 years) vs. 5/10 and 5/10, respectively, for 45F (63+/-11 years: NS). Body weight and surface area (BSA) were 83+/-9 kg (1.9+/-0.2 m2, max 2.2 m2) for 36F vs. 79+/-6 kg: NS (1.9+/-0.1 m2 (NS), max 2.1 m2) for 45F. Insertion and access orifice diameter (area) was 6 mm and 10 mm (78.5 mm2) for the 36F vs. 6 mm and 13 mm (132 mm2) for the 45F (+69%). Calculated target pump flow (2.4 l/min/m2) was 4.7+/-0.4 l/min for 36F vs. 4.5+/-0.3 l/min for 45F. Achieved pump flow accounted for 5.0+/-0.3 l/min for 36F (8% above target) vs. 4.8+/-0.3 l/min for 45F (8% above target): NS. The water balance during the pump run (clear volume added minus hemofilter and urine output) was 2.2+/-0.3 l for 36F vs. 2.0 l for 45F: NS. CONCLUSION: Due to its 'open' wall (the vena cava provides the seal), its reduced wall thickness (range: 0.0-0.4 mm), and its self-expanding design, the 36F smartcanula requiring a 30F access orifice has sufficient drainage capacity by gravity alone for full CPB in adults with a BSA up to 2.2 mm2.
Resumo:
Le but de cette thèse a été d'investiguer la relation entre, d'une part le temps de propagation de l'onde de pouls artérielle du coeur vers les membres inférieurs, et d'autre part le temps séparant, au niveau de l'aorte ascendante, la génération de l'onde antérograde du retour des ondes réfléchies. Le principe de la méthode employée a été de mesurer ces deux temps par deux méthodes indépendantes, ce en les faisant varier par changement rapide de la position du corps, chez sujets humains volontaires. Le facteur gravitationnel a en effet une influence majeure sur la pression transmurale des artères, dont dépend largement la vitesse de propagation des ondes de pouls, tant dans le sens antérograde que rétrograde. Vingt sujets jeunes, en bonne santé, dontIO hommes et 10 femmes, ont été examinés sur une table de tilt, dans deux positions différentes : tête vers le bas (angle de tilt : - 10°) et tête vers le haut (+45°).Dans chaque position, le temps de propagation carotido- femorale (Tcf, succédané du temps aorto-fémoral) et carotido-tibial (Tct, succédané du temps aorto-tibial) a été mesuré avec l'appareil Complior. De même, dans chaque position la pression aortique centrale a été enregistrée par tonométrie radiale en utilisant l'appareil SphygmoCor qui applique une fonction de transfert généralisé pour reconstruire la forme de l'onde de pouls aortique. L'analyse de celle-ci permet ensuite de calculer les temps d'aller-retour des ondes réfléchies atteignant l'aorte pendant la systole (début de l'onde réfléchie, sT1 r) et pendant la diastole (temps de transit moyen de l'onde diastolique réfléchie dMTT). Le changement de position de tête vers le haut à tête vers le bas, a provoqué une augmentation importante du temps de propagation Tct (chez le femmes de 130±10 à 185±18msec, P<0,001 et chez les hommes de 136±9 à 204±18msec P<0.001) ainsi que du temps moyen de transition de l'onde diastolique réfléchie dMTT (chez les femmes de 364±35 à 499±33msec P<0,001 et chez les hommes de 406±22 à 553±21msec, P<0,001). Un modèle de régression mixte montre qu'entre les deux positions, les variations de dMTT sont environ le double de celles de Tct (coefficient de régression 2.1; 95% intervalle de confiance 1.9-2,3, P<0,001). Ces résultats suggèrent que les ondes diastoliques observées dans l'onde de pouls aortique central reconstruites par tonométrie radiale, correspondent, du moins en partie, aux ondes réfléchies générées au niveau des membres inférieurs.
Resumo:
Les voies veineuses centrales (VVC) sont essentielles pour l'administration de la nutrition parentérale. Le risque de complications est dépendant de la qualité des soins apportés à la VVC qui influence de ce fait la qualité de vie des patients et le coût des soins. Beaucoup de complications des VVC, infectieuses ou non, peuvent être prévenues par l'existence de protocoles de soins appropriés et standardisés. L'information sur les soins des VVC et les éventuelles complications est essentielle pour le dépistage et le traitement précoce de ces complications ; elle doit faire l'objet de protocoles partagés entre les patients et les soignants. Cet article décrit une évaluation des pratiques professionnelles sous la forme d'un audit clinique destiné à améliorer la qualité de soins des patients en nutrition parentérale porteurs de VVC. Central venous access devices (CVAD) are essential for the administration of parenteral nutrition. The quality of the care of CVAD influences the risk of complications and so the quality of life of the patients and the costs of care. Numerous infectious or non-infectious complications of CVAD can be prevented by appropriate, standardized protocols of care. Information about the care of CVAD and complications is essential for the early recognition and treatment of complications and should be shared between patients and caregivers. This article describes an audit for CAVD care that can be used to improve quality of care in a professional practice evaluation program.
Resumo:
The present work was undertaken to investigate, in young healthy volunteers, the relationships between the forward propagation times of arterial pressure waves and the timing of reflected waves observable on the aortic pulse, in the course of rapid changes in body position. 20 young healthy subjects, 10 men, and 10 women, were examined on a tilt table at two different tilt angles, -10° (Head-down) and + 45° (Head-up). In each position, carotid-femoral (Tcf) and carotid-tibial forward propagation times (Tct) were measured with the Complior device. In each position also, the central aortic pressure pulse was recorded with radial tonometry, using the SphygmoCor device and a generalized transfer function, so as to evaluate the timing of reflected waves reaching the aorta in systole (onset of systolic reflected wave, sT1r) and diastole (mean transit time of diastolic reflected wave, dMTT). The position shift from Head-up to Head-down caused a massive increase in both Tct (women from 130 ± 10 to 185 ± 18 msec P < 0.001, men from 136 ± 9 to 204 ± 18 msec P < 0.001) and dMTT (women from 364 ± 35 to 499 ± 33 msec P < 0.001, men from 406 ± 22 to 553 ± 21 msec P < 0.001). Mixed model regression showed that the changes in Tct and dMTT observed between Head-up and Head-down were tightly coupled (regression coefficient 2.1, 95% confidence interval 1.9-2.3, P < 0.001). These results strongly suggest that the diastolic waves observed on central aortic pulses reconstructed from radial tonometric correspond at least in part to reflections generated in the lower limbs.
Resumo:
Complications from central venous catheterization include infectious conditions, pneumothorax, hemothorax and venous thrombosis. Pericardial effusion with cardiac tamponade hardly occurs, and in infants is generally caused by umbilical catheterization. The authors describe the case of cardiac tamponade occurred in an infant during chest computed tomography with contrast infusion through a central venous catheter inserted into the right internal jugular vein.
Resumo:
Cateteres venosos centrais inseridos em pacientes internados em unidade de terapia intensiva foram avaliados por métodos microbiológicos (cultura semi-quantitativa) e microscopia eletrônica de varredura a fim de detectar adesão microbiana e correlacionar com a cultura de sangue. Durante o período de estudo, foram avaliados 59 pacientes com cateter venoso central. A idade dos pacientes, sexo, sítio de inserção e tempo de permanência do cateter foram anotados. O cateter era de poliuretano não tunelizado e de único lúmen. O sangue para cultura foi coletado no momento da remoção do cateter. de 63 pontas de cateteres, 30 (47,6%) foram colonizadas e a infecção encontrada em 5 (23,8%) cateteres. A infecção foi mais prevalente em 26 pacientes (41,3%) com cateteres inseridos em veia subclávia do que nos 3 (3,2%) inseridos em veia jugular. A infecção foi observada com mais freqüência em cateteres com tempo de permanência maior do que sete dias. Os microrganismos isolados incluíram 32 estafilococos coagulase-negativa (29,7%), 61 bactérias Gram-negativas (52,9%), 9 estafilcocos coagulase-positiva (8,3%) e 3 leveduras (2,7%). Como agentes causais de infecções em unidade de terapia intensiva foram isolados E. aerogenes, P. aeruginosa, A. baumannii. Os antimicrobianos com maior atividade in vitro contra as bactérias Gram-negativas foram o imipenem e contra as Gram-positivas vancomicina, cefepime, penicilina, rifampicina e tetraciclina. As análises por microscopia eletrônica de varredura revelaram biofilmes sobre a superfície de todos os cateteres examinados.
Resumo:
As infecções devido a biofilmes bacterianos são comuns em pacientes sob tratamento em hemodiálise. Neste estudo, 16 pacientes (7 homens, 9 mulheres, de 22 a 81 anos, média 50 anos de idade), com um total de 25 cateteres de hemodiálise (3 de triplo-lúmen e 22 de duplo-lúmen) de poliuretano inseridos em veia subclávia foram estudados. Os cateteres permaneceram no local de 3 a 91 dias (média de 47 dias). Os cateteres foram removidos devido ao: mau funcionamento (44%), suspeita de infecção relacionada ao cateter (20%), viabilidade de um acesso permanente (16%), remoção acidental (12%), sinais e sintomas de infecção no local da inserção do cateter (4%) e contaminação exógena (4%). Culturas positivas de ponta foram observadas em sete cateteres (28%), concomitantemente com três culturas positivas de sangue. Das culturas de sangue foram identificados Staphylococcus aureus (12%) e de uma das conexões foi isolado S. aureus. Biofilmes foram observados sobre todas as pontas de cateteres. Os S. aureus isolados do sangue e cateter (ponta e conexão) eram resistentes a pencilina e sensíveis a azitromicina, ciprofloxacina, clindamicina, cloranfenicol, gentamicina, oxacilina, rifampicina, sulfametoxazole, tetraciclina e vancomicina. As cepas de S. aureus isoladas de sangue, ponta de cateter e conexão foram consideradas idênticas devido à coincidência do perfil de sensibilidade. E similaridade genética, avaliada por meio de ribotipagem.