368 resultados para catheterization
Resumo:
Umbilical venous catheters allow rapid central access in neonates, but may be associated with various complications. We present a case of a newborn with pericardial effusion following umbilical venous catheterization. An extremely low birth weight infant was intubated for respiratory distress syndrome and had umbilical venous and arterial lines in place. Massive cardiomegaly was noted on the subsequent chest X-ray. Echocardiography revealed a large pericardial effusion without signs of tamponade. After removing the catheter, the effusion gradually resolved. While pericardial effusion is a well-known complication of percutaneous long central lines, only a few case reports have documented sudden cardiovascular compromise associated with umbilical venous catheters. Pericardial effusion may be asymptomatic and should be suspected in infants with central catheters and progressive cardiomegaly. The prompt removal of catheters and, if signs of cardiac tamponade are present, emergency pericardiocentesis may prove to be life-saving.
Resumo:
PURPOSE: In male patients with ileal bladder substitute we ascertained the likelihood of spontaneous voiding failure, the corrective procedures required and the eventual outcomes. MATERIALS AND METHODS: Following cystectomy and ileal bladder substitution for urothelial cancer between April 1985 and September 2002 male patients were identified and analyzed from the prospective departmental database. Four patients underwent ileum conduit conversion following urethral recurrence or pouch necrosis and were excluded from study. Funnel-shaped outlets were avoided during bladder substitute surgery after the first 4 patients with this configuration experienced voiding failure and required corrective procedures. Only patients with a minimum 5-year followup were assessed for voiding failure, corrective procedures and final outcomes. RESULTS: Of 354 patients with a median age of 65 years (range 36 to 84) treated with bladder substitute 180 (51%) were alive at 5 years. All 180 of these patients spontaneously voided within 3 months of surgery. During this 5-year observation period 22 (12%) patients experienced voiding problems requiring de-obstructive procedures. Following intervention 177 (98%) patients were spontaneously voiding by 5 years. Of 237 patients 77 (32%) were alive at 10 years. Of these 77 patients followed for another 5 years 10 (13%) had similar voiding problems requiring de-obstructive procedures. Subsequently 74 (96%) were voiding spontaneously by 10 years. CONCLUSIONS: Patients often fail to void spontaneously after ileal bladder substitution. However, if a funnel-shaped outlet is avoided and de-obstructive surgery is appropriately implemented, excellent long-term results are seen with spontaneous voiding and clean intermittent catheterization can be avoided.
Resumo:
The exponential increase in cardioverter-defibrillator implantations has resulted in a need for safe implantations that do not require long waiting periods. We report intraoperative and follow-up results in 48 patients with ventricular tachyarrhythmias who underwent cardioverter-defibrillator implantation in the catheterization laboratory. Twenty-six (54%) patients had their first cardioverter-defibrillator implant (group 1), and 22 (46%) patients underwent pulse-generator replacement (group 2). In all patients, cardioverter-defibrillator implant or pulse-generator replacement was performed with the patient under general anesthesia. In 25 (96%) of 26 patients in group 1, cardioverter-defibrillator implantation was possible with a mean defibrillation threshold of 13 +/- 8 J. One patient had a defibrillation threshold of > 25 J, and therefore cardioverter-defibrillator implant was not achieved. This patient underwent epicardial device implantation 1 day later. Another patient in group 1 had vessel rupture (vena subclavia) intraoperatively. During a mean follow-up of 2 +/- 1 months, two patients died from congestive heart failure 2 and 4 months after device implantation. An infection occurred in one patient in group 2, 3 months after generator replacement. In conclusion, these data show that in the majority of patients cardioverter-defibrillator implantation in the catheterization laboratory is safe and has a low complication rate and therefore can generally be recommended.
Resumo:
OBJECTIVE: To investigate the hypothesis that the need for clean intermittent self-catheterization after botulinum neurotoxin type A injections is outweighed by the efficacy of this treatment, so that clean intermittent self-catheterization is not a burden for patients with refractory idiopathic detrusor overactivity. METHODS: Women undergoing intradetrusor injections of 200 units botulinum neurotoxin type A for refractory idiopathic detrusor overactivity were evaluated prospectively. Clean intermittent self-catheterization was discussed with all patients and its possible need after botulinum neurotoxin type A treatment. As indicator of quality of life, lower urinary tract symptom distress and effect on daily activities were assessed using the validated Urogenital Distress Inventory (UDI-6) and Incontinence Impact Questionnaire (IIQ-7) before and 4 weeks after receiving botulinum neurotoxin type A injections. RESULTS: Mean age of the 65 women was 51 years, and all voided spontaneously before botulinum neurotoxin type A injections. After botulinum neurotoxin type A treatment, 28 (43%) required clean intermittent self-catheterization. Mean UDI-6 and IIQ-7 scores reduced from 61 to 33 (P<.001) and 62 to 30 (P<.001) in women performing clean intermittent self-catheterization and from 60 to 28 (P<.001) and 64 to 25 (P<.001) in those who did not, respectively. Comparison of quality of life in women performing clean intermittent self-catheterization and in those who did not revealed no significant differences before and after botulinum neurotoxin type A treatment. CONCLUSION: Clean intermittent self-catheterization after botulinum neurotoxin type A intradetrusor injections did not impair quality of life in appropriately informed and selected women in the short term. All patients should be informed of the potential need for clean intermittent self-catheterization after botulinum neurotoxin type A injections, and a willingness to do so should be a prerequisite for this still unlicensed off-label treatment.
Resumo:
AIM: To assess patients' perception of clean intermittent self-catheterization (CISC) for voiding dysfunction. PATIENTS AND METHODS: A total of 101 patients performing CISC because of voiding dysfunction were invited to participate in this questionnaire survey. The response rate was 91% (92/101). RESULTS: The mean time over which CISC was performed was 5 years (standard deviation (SD) +/- 6.3) and the mean frequency of CISC per day was three times (SD +/- 2). Almost 80% (72/92) of the patients perceived CISC as easy or very easy and CISC did not interfere at all or interfered a little bit with work or other regular daily activities in more than 80% (76/92). Almost 90% (80/92) reported no or minimal pain while performing CISC. This did not interfere at all or interfered a little bit with work or other regular daily activities in almost 90% (80/92). Quality of life improved considerably due to CISC in more than 60% (56/92) and 12% (11/92) complained of a deterioration. In multivariable analysis, severe pain performing CISC (odds ratio 20.9, 95% confidence interval 1.7-259.9, P = 0.018) was the only factor that predicted poor quality of life. CONCLUSIONS: The majority of patients considered CISC to be an easy and painless procedure which did not interfere with daily activities. Consequently, quality of life improved in more than 60% of the patients. Therefore, CISC does not appear to be a burden for the patient and, from a patient's perspective, can be recommended.
Resumo:
Background and objectives Central venous catheterization of the internal jugular vein is a commonly performed invasive procedure associated with a significant morbidity and even mortality. Ultrasound-guided methods have shown to significantly improve the success of the technique and are recommended by various scientific societies, including the American Society of Anesthesiologists. The aim of this report is to describe an innovative ultrasound-guided central line placement of the internal jugular vein. Technique The authors describe an innovative ultrasound-guided central line placement of the internal jugular vein based on an oblique approach – the “Syringe-Free” approach. This technique allows immediate progression of the guide wire in the venous lumen, while maintaining a real-time continuous ultrasound image. Conclusions The described method adds to the traditional oblique technique the possibility of achieving a continuous real-time ultrasound-guided venipuncture and a guide wire insertion that does not need removing the probe from the puncture field, while having a single operator performing the whole procedure.
Resumo:
To compare the hemodynamic changes following two different lipid emulsion therapies after bupivacaine intoxication in swines. Large White pigs were anesthetized with thiopental, tracheal intubation performed and mechanical ventilation instituted. Hemodynamic variables were recorded with invasive pressure monitoring and pulmonary artery catheterization (Swan-Ganz catheter). After a 30-minute resting period, 5 mg.kg-1 of bupivacaine by intravenous injection was administered and new hemodynamic measures were performed 1 minute later; the animals were than randomly divided into three groups and received 4 ml.kg-1 of one of the two different lipid emulsion with standard long-chaim triglyceride, or mixture of long and medium-chain triglyceride, or saline solution. Hemodynamic changes were then re-evaluated at 5, 10, 15, 20 and 30 minutes. Bupivacaine intoxication caused fall in arterial blood pressure, cardiac index, ventricular systolic work index mainly and no important changes in vascular resistances. Both emulsion improved arterial blood pressure mainly increasing vascular resistance since the cardiac index had no significant improvement. On the systemic circulation the hemodynamic results were similar with both lipid emulsions. Both lipid emulsions were efficient and similar options to reverse hypotension in cases of bupivacaine toxicity.
Resumo:
Background: TCF7L2 polymorphisms have been consistently associated with type 2 diabetes mellitus in different populations and type 2 diabetes mellitus is a major risk factor for cardiovascular disease, especially coronary artery disease. This study aimed to evaluate the association between TCF7L2 polymorphism rs7903146 and coronary artery disease in diabetic and non-diabetic subjects. Methods and Results: two populations were studied in order to assess severity of coronary artery disease and cardiovascular events incidence. Eight-hundred and eighty nine subjects who were referred for cardiac catheterization for coronary artery disease diagnosis were cross-sectionally evaluated for coronary lesions (atherosclerotic burden) and 559 subjects from the MASS-II Trial were prospectively followed-up for 5 years and assessed for major cardiovascular events incidence. As expected, rs7903146 T allele was associated with diabetes. Although diabetic patients had a higher prevalence of coronary lesions, no association between TCF7L2 genotype and coronary lesions was found in this subgroup. However, non-diabetic individuals carrying the T allele were associated with a significantly higher frequency of coronary lesions than non-diabetic non-carriers of the risk allele (adjusted OR = 2.32 95% CI 1.27-4.24, p = 0.006). Moreover, presence of multi-vessel coronary artery disease was also associated with the CT or TT genotypes in non-diabetics. Similarly, from the prospective sample analysis, non-diabetics carrying the CT/TT genotypes had significantly more composite cardiovascular end-points events than CC carriers (p = 0.049), mainly due to an increased incidence of death (p = 0.004). Conclusions: rs7903146 T allele is associated with diabetes and, in non-diabetic individuals, with a higher prevalence and severity of coronary artery disease and cardiovascular events. name of registry site (see list below), registration number, trial registration URL in brackets.
Resumo:
Background: Studies have shown that the autonomic dysfunction accompanied by impaired baroreflex sensitivity was associated with higher mortality. However, the influence of decreased baroreflex sensitivity on cardiac function, especially in diastolic function, is not well understood. This study evaluated the morpho-functional changes associated with baroreflex impairment induced by chronic sinoaortic denervation (SAD). Methods and Results: Animals were divided into sinoaortic denervation (SAD) and control (C) groups. Baroreflex sensitivity was evaluated by tachycardic and bradycardic responses, induced by vasoactive drugs. Cardiac function was studied by echocardiography and by left ventricle (LV) catheterization. LV collagen content and the expression of regulatory proteins involved in intracellular Ca(2+) homeostasis were quantified. Results showed higher LV mass in SAD versus C animals. Furthermore, an increase in deceleration time of E-wave in the SAD versus the C group (2.14 +/- 0.07 ms vs 1.78 +/- 0.03 ms) was observed. LV end-diastolic pressure was increased and the minimum dP/dt was decreased in the SAD versus the C group (12 +/- 1.5 mm Hg vs 5.3 +/- 0.2 mm Hg and 7,422 +/- 201 vs 4,999 +/- 345 mm Hg/s, respectively). SERCA/NCX ratio was lower in SAD than in control rats. The same was verified in SERCA/PLB ratio. Conclusions: The results suggest that baroreflex dysfunction is associated with cardiac diastolic dysfunction independently of the presence of other risk factors. (J Cardiac Fail 2011;17:519-525)
Resumo:
Objectives: We tested two novel drug-eluting stents (DES), covered with a biodegradable-polymer carrier and releasing paclitaxel or sirolimus, which were compared against a bare metal stent (primary objective). The DES differed by the drug, but were identical otherwise, allowing to compare the anti-restenosis effects of sirolimus versus paclitaxel (secondary objective). Background: The efficacy of novel DES with biodegradable polymers should be tested in the context of randomized trials, even when using drugs known to be effective, such as sirolimus and paclitaxel. Methods: Overall, 274 patients with de novo coronary lesions in native vessels scheduled for stent implantation were randomly assigned (2:21 ratio) for the paclitaxel (n = 111), sirolimus (n = 106), or bare metal stent (n = 57) groups. Angiographic follow-up was obtained at 9 months and major cardiac adverse events up to 12 months. Results: Both paclitaxel and sirolimus stents reduced the 9-month in-stent late loss (0.54-0.44 mm, 0.32-0.43 mm, vs. 0.90-0.45 mm respectively), and 1-year risk of target vessel revascularization and combined major adverse cardiac events (P < 0.05 for both, in all comparisons), compared with controls. Sirolimus stents had lower late loss than paclitaxel stents (P < 0.01), but similar 1-year clinical outcomes. There were no differences in the risk of death, infarction, or stent thrombosis among the study groups. Conclusion: Both novel DES were effective in reducing neointimal hyperplasia and 1-year re-intervention, compared to bare metal stents. Our findings also suggest that sirolimus is more effective than paclitaxel in reducing angiographic neointima, although this effect was not associated with better clinical outcomes. (C) 2009 Wiley-Liss, Inc.
Resumo:
Objectives: Pneumothorax is a frequent complication during mechanical ventilation. Electrical impedance tomography (EIT) is a noninvasive tool that allows real-time imaging of regional ventilation. The purpose of this study was to 1) identify characteristic changes in the EIT signals associated with pneumothoraces; 2) develop and fine-tune an algorithm for their automatic detection; and 3) prospectively evaluate this algorithm for its sensitivity and specificity in detecting pneumothoraces in real time. Design: Prospective controlled laboratory animal investigation. Setting: Experimental Pulmonology Laboratory of the University of Sao Paulo. Subjects: Thirty-nine anesthetized mechanically ventilated supine pigs (31.0 +/- 3.2 kg, mean +/- SD). Interventions. In a first group of 18 animals monitored by EIT, we either injected progressive amounts of air (from 20 to 500 mL) through chest tubes or applied large positive end-expiratory pressure (PEEP) increments to simulate extreme lung overdistension. This first data set was used to calibrate an EIT-based pneumothorax detection algorithm. Subsequently, we evaluated the real-time performance of the detection algorithm in 21 additional animals (with normal or preinjured lungs), submitted to multiple ventilatory interventions or traumatic punctures of the lung. Measurements and Main Results: Primary EIT relative images were acquired online (50 images/sec) and processed according to a few imaging-analysis routines running automatically and in parallel. Pneumothoraces as small as 20 mL could be detected with a sensitivity of 100% and specificity 95% and could be easily distinguished from parenchymal overdistension induced by PEEP or recruiting maneuvers, Their location was correctly identified in all cases, with a total delay of only three respiratory cycles. Conclusions. We created an EIT-based algorithm capable of detecting early signs of pneumothoraces in high-risk situations, which also identifies its location. It requires that the pneumothorax occurs or enlarges at least minimally during the monitoring period. Such detection was operator-free and in quasi real-time, opening opportunities for improving patient safety during mechanical ventilation.