30 resultados para borates


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Greaves, George; Sen, S., (2007) 'Inorganic glasses, glass-forming liquids and amorphizing solids', Advances in Physics 56(1) pp.1-166 RAE2008

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Poly(vinyl alcohol)-tetrahydroxyborate (PVA-THB) hydrogels are dilatant formulations with potential for topical wound management. To support this contention, the physical properties, rheological behaviour and component release of candidate formulations were investigated. Oscillatory rheometry and texture profile analysis were used at room temperature and 37 °C. Results showed that it was possible to control the rheological and textural properties by altering component concentration and modifying the type of PVA polymer used. Hydrogels made using PVA grades with higher degrees of hydrolysis displayed favourable characteristics from a wound healing perspective. In vitro release of borate and PVA were assessed in order to evaluate potential clinical dosing of free species originating from the hydrogel structure. Component diffusion was influenced by both concentration and molecular weight, where relevant, with up to 5% free PVA cumulative release observed after 30 min. The results of this study demonstrated the importance of poly(vinyl alcohol) selection for ensuring appropriate gel formation in PVA-THB hydrogels. The benefits of higher degrees of hydrolysis, in particular, included lower excipient release and reduced bioadhesion. The unique physical characteristics of these hydrogels make them an appealing delivery vehicle for chronic and acute wound management purposes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to assess a novel semisolid material as a potential topical drug delivery system for acute laceration. The objectives were to correlate physical characterization data using rheologic studies and to compare with clinical assessment of performance in an emergency department (ED).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thermoluminescence (TL) response of Dy and Li doped 20CaB(4)O(7)-80CaB(2)O(4) (Wt%) glass-ceramic irradiated with ultraviolet (UV) radiation was studied. In order to act as TL activator ions, the Dy and Li ions were included in the matrix during the melting process to increase its TL efficiency. A single crystalline CaB2O4 phase was present in the glass-ceramic as determined by X-ray diffraction (XRD). The glass-ceramic 20CaB(4)O(7)-80CaB(2)O(4):Dy,Li wt% (named 20CBO7:Dy,Li) is a newly prepared TL material. Its thermoluminescent dosimetric characteristics have shown a linear response under UV radiation exposure and a good TL signal reproducibility, thus proving to be a promising material for using as an ultraviolet radiation dosimeter. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Borate glasses present an absorption coefficient very close to that of human tissue. This fact makes some borates ideal materials to develop medical and environmental dosimeters. Glass compositions with calcium tetraborate (CaB4O7) and calcium metaborate (CaB2O4), such as the xCaB(4)O(7) - (100-x)CaB2O4 System (0 <= x <= 100 wt%) were obtained by the traditional melting/quenching method. A phenomenon widely known as the 'boron anomaly' was observed in our thermal analysis measurements, as indicated by the increase of T, and the appearance of a maximum value in the composition with 40 wt% of CaB2O4. The Dy doped and Li co-doped 80CaB(4)O(7)-20CaB(2)O(4) (Wt%) glass samples were studied by the thermoluminescence technique. The addition of Dy improved the signal sensitivity in about three times with respect to the undoped glass sample. The addition of Li as a co-dopant in this glass caused a shift to a lower temperature of about 20 degrees C in the main glow peak. The structural analysis of the 80CaB(4)O(7)-20CaB(2)O(4) (wt%) undoped and doped samples were studied through infrared absorption. We have noted an increase in the coordination number of the boron atoms from 3 to 4, i.e., the conversion of the BO3 triangular structural units into BO4 tetrahedra. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An interferometric technique was used to determine the temperature coefficient of the optical path length (dS/dT) as a function of the temperature in several optical glasses. The temperature range was between 25degreesC and 180degreesC. The studied samples included undoped and doped oxide glasses, such as low silica calcium aluminosilicate, phosphates, borates and also chalcogenides. The oxide glasses had dS/dT between 10 X 10(-6) K-1 and 20x10(-6) K-1, while for the chalcogenides, these were around 70 x 10(-6)K(-1). The results showed that dS/dTs increased with the temperature in all samples. For samples doped with Nd the dS/dT values were found to be independent of concentration. on the other hand, for the phosphate glass doped with Cr, dS/dT increased about 5% when compared with the Nd doped one. In conclusion, the used interferometric method, which is a considerably simpler and a lower cost technique, and is a useful tool to measure dS/dT in semi-transparent glasses as a function of the composition and temperature. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thermoluminescence (TL) response of Dy and Li doped 20CaB(4)O(7)-80CaB(2)O(4) (Wt%) glass-ceramic irradiated with ultraviolet (UV) radiation was studied. In order to act as TL activator ions, the Dy and Li ions were included in the matrix during the melting process to increase its TL efficiency. A single crystalline CaB2O4 phase was present in the glass-ceramic as determined by X-ray diffraction (XRD). The glass-ceramic 20CaB(4)O(7)-80CaB(2)O(4):Dy,Li wt% (named 20CBO7:Dy,Li) is a newly prepared TL material. Its thermoluminescent dosimetric characteristics have shown a linear response under UV radiation exposure and a good TL signal reproducibility, thus proving to be a promising material for using as an ultraviolet radiation dosimeter. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effectiveness of disinfectant solutions (1% sodium hypochlorite, 2% chlorhexidine digluconate, 2% glutaraldehyde, 100% vinegar, tabs of sodium perborate-based denture cleanser, and 3.8% sodium perborate) in the disinfection of acrylic resin specimens (n = 10/group) contaminated in vitro by Candida albicans, Streptococcus mutans, S. aureus, Escherichia coli, or Bacillus subtilis as measured by residual colony-forming unit (CFU). In a separate experiment, acrylic resin was treated with disinfectants to monitor potential effects on surface roughness, Ra (μm), which might facilitate microbial adherence. Materials and Methods: Three hundred fifty acrylic resin specimens contaminated in vitro with 1×10 6 cells/ml suspensions of standard strains of the cited microorganisms were immersed in the disinfectants for 10 minutes; the control group was not submitted to any disinfection process. Final counts of microorganisms per ml were performed by plating method for the evaluation of microbial level reduction. Results were compared statistically by ANOVA and Tukey's test (p ≤ 0.05). In a parallel study aiming to evaluate the effect of the tested disinfectant on resin surface, 60 specimens were analyzed in a digital rugosimeter before and after ten cycles of 10-minute immersion in the disinfectants. Measurements of superficial roughness, Ra (μm), were compared statistically by paired t-test (p ≤ 0.05). Results: The results showed that 1% sodium hypochlorite, 2% glutaraldehyde, and 2% chlorhexidine digluconate were most effective against the analyzed microorganisms, followed by 100% vinegar, 3.8% sodium perborate, and tabs of sodium perborate-based denture cleanser. Superficial roughness of the specimens was higher after disinfection cycles with 3.8% sodium perborate (p = 0.03) and lower after the cycles with 2% chlorhexidine digluconate (p = 0.04). Conclusion: Within the limits of this experiment, it could be concluded that 1% sodium hypochlorite, 2% glutaraldehyde, 2% chlorexidine, 100% vinegar, and 3.8% sodium perborate are valid alternatives for the disinfection of acrylic resin. © 2008 by The American College of Prosthodontists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate alternative methods for the disinfection of toothbrushes considering that most of the previously proposed methods are expensive and cannot be easily implemented. Two-hundred toothbrushes with standardized dimensions and bristles were included in the study. The toothbrushes were divided into 20 experimental groups (n=10), according to microorganism considered and chemical agent used. The toothbrushes were contaminated in vitro by standardized suspensions of Streptococcus mutans, Streptococcus pyogenes, Staphylococcus aureus or Candida albicans. The following disinfectants were tested: 0.12% chlorhexidine digluconate, 50% white vinegar, a triclosan-containing dentifrice solution, and a perborate-based tablet solution. The disinfection method was immersion in the disinfectant for 10min. After the disinfection procedure, the number of remaining microbial cells was evaluated. The values of cfu/toothbrush of each group of microorganism after disinfection were compared by Kruskal-Wallis ANOVA and Dunn's test for multiple comparisons (5%). The chlorhexidine digluconate solution was the most effective disinfectant. The triclosan-based dentifrice solution promoted a significant reduction of all microorganisms' counts in relation to the control group. As to the disinfection with 50% vinegar, a significant reduction was observed for all the microorganisms, except for C. albicans. The sodium perborate solution was the less effective against the tested microorganisms. Solutions based on triclosan-containing dentifrice may be considered effective, nontoxic, cost-effective, and an easily applicable alternative for the disinfection of toothbrushes. The vinegar solution reduced the presence of S. aureus, S. mutans and S. pyogenes on toothbrushes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: This study aimed to measure pH changes during 14 days intracoronal bleaching with hydrogen peroxide/sodium perborate and carbamide peroxide/sodium perborate. Materials and methods: Twenty patients presenting endodontically treated central maxillary incisors with color alterations were divided in two groups (n = 10): Group CP + SP: 37% carbamide peroxide + sodium perborate paste; Group HP + SP: 30% hydrogen peroxide + sodium perborate paste. The pH values were measured using a digital microprocessor at different times: Baseline, 2, 7 and 14 days. Data were analyzed with two-way ANOVA followed by Tukey's test (α = 0.05). Results: ANOVA showed p < 0.00 which indicated significant difference between the groups. The mean values (± sd) and the results of the Tukey's test were: HP + SP/14 days-7.98 (±0.58)a; HP + SP/7 days-8.59 (±0.18)b; HP + SP/2 days-8.83 (±0.32)bc; HP + SP/Baseline-8.83 (±0.01)bc; CP + SP/Baseline-8.89 (±0.01)bc; CP + SP/14 days-9.11 (±0.58)cd; CP + SP/7 days-9.54 (±0.16)de; CP + SP/2 days-9.66 (±0.08) de. The group HP + SP resulted in significantly lower pH values compared with group CP + SP. Conclusion: It can be concluded that both associations showed alkaline pH values; however, there was significant reduction in the pH values of the 30% hydrogen peroxide associated with sodium perborate after 14 days. Clinical Significance: The association of hydrogen peroxide and carbamide peroxide with sodium perborate paste presented alkaline characteristics during the 14-day evaluated period. Thus, regarding pH changes, both associations can be considered safe as intracoronal bleaching agents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência dos Materiais - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Environ 90% des composés produits industriellement sont fabriqués à l’aide de catalyseurs. C’est pourquoi la conception de catalyseurs toujours plus performants pour améliorer les procédés industriels actuels est toujours d’intérêt. De la grande variété de complexes avec des métaux de transition rapportés jusqu’à présent, les complexes zwitterioniques attirent notre attention par leurs activités catalytiques souvent supérieures aux complexes cationiques normaux. Un complexe métallique zwitterionique est un fragment métal-ligand neutre où la charge positive est située sur le centre métallique et où la charge négative est délocalisée sur un des ligands liés au métal. Nous proposons la synthèse de ligands anioniques phosphine comportant des groupements borates et boratabenzènes. Cette dernière espèce est un cycle à 6 membres où l’un des atomes de carbone est remplacé par un atome de bore et qui est négativement chargé. La capacité de ces phosphines anioniques à se lier à un centre métallique à l’aide de la paire libre du phosphore est due à la nature du lien P-B qui défavorise l’interaction entre la paire libre du phosphore et l’orbitale p vide du bore. Les propriétés de di-tert-butylphosphido-boratabenzène (DTBB) comme ligand phosphine anionique hautement donneur et encombré ainsi que la découverte de ses modes de coordination inhabituels pour stabiliser les métaux de transition insaturés ont été étudiés au cours de ce travail. De nouvelles perspectives sur les modes de coordination de phosphido-boratabenzène et la force de l’interaction du lien P-B seront discutées ainsi que les applications catalytiques. Nous avons d’abord étudié la coordination η1 avec des complexes de fer, ce qui nous a fourni des données quantitatives précieuses sur la capacité du DTBB d’agir comme ligand très donneur par rapport aux autres ligands donneurs bien connus. La capacité du DTBB à changer de mode de coordination pour soutenir les besoins électroniques du métal a été démontrée par la découverte d’une nouvelle espèce ferrocenyl phosphido-boratabenzène et sa nucléophilie a été étudiée. Au meilleur de notre connaissance, aucun exemple d’un ligand boratabenzène coordonné aux métaux du groupe 11 n’existe dans la littérature. Voilà pourquoi nous avons décidé d’explorer les modes de coordination du ligand DTBB avec Cu(I), Ag(I) et Au(I). A notre grande surprise, le ligand DTBB est capable de stabiliser les métaux du groupe 11 aux états d’oxydation faibles par une liaison MP qui est une coordination du type η1, un mode de coordination guère observé pour les ligands boratabenzène. Pendant nos travaux, notre attention s’est tournée vers la synthèse d’un complexe de rhodium(I) afin de tester son utilité en catalyse. A notre grande satisfaction, le complexe Rh-DTBB agit comme un précatalyseur pour l’hydrogénation des alcènes et alcynes à la température ambiante et à pression atmosphérique et son activité est comparable à celle du catalyseur de Wilkinson. Dans un désir d’élargir les applications de notre recherche, notre attention se tourna vers l’utilisation des composés du bore autres que le boratabenzène. Nous avons décidé de synthétiser une nouvelle espèce phosphido-borate encombrée. Lorsqu’elle réagit avec des métaux, l’espèce phosphido-borate subit un clivage de la liaison P-B. Toutefois, cette observation met en évidence la singularité et les avantages de la stabilité de la liaison P-B lors de l’utilisation du fragment boratabenzène. Ces observations enrichissent notre compréhension des conditions dans lesquelles la liaison P-B du ligand DTBB peut être clivée. Ces travaux ont mené à la découverte d’un nouveau ligand ansa-boratabenzène avec une chimie de coordination prometteuse.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The progress of hydrogen generation by sodium borohydride hydrolysis depends highly on the development of efficient catalysts based on non-noble metals such as cobalt. However, such catalysts undergo extensive deactivation which has a detrimental effect on their stability. Herein, highly porous copper and cobalt-based bimetallic foams, CuxCo100-x (x = 0-100 at%), produced by electrodeposition using the dynamic hydrogen bubble template are reported. The chemical composition of the foams was optimized in order to enhance specific surface area and improve their catalytic activity and stability as heterogeneous catalysts for sodium borohydride hydrolysis. Among the tested catalysts, copper-rich samples like Cu85Co15 are slightly more active than Co-100 and above all, they are less sensitive to deactivation by borates adsorption. Porous copper-rich foams were found to be an alternative to cobalt as low-cost, active and stable heterogeneous catalysts for hydrogen generation by hydrolysis of sodium borohydride. (C) 2016 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.