998 resultados para bonding quality
Resumo:
one hundred (n=100) elderly outpatients with diabetic retinopathy taking antihypertensives and/or oral antidiabetics/insulin were interviewed. Adherence was evaluated by the adherence proportion and its association with the care taken in administrating medications and by the Morisky Scale. The National Eye Institute Visual Functioning Questionnaire (NEI VFQ-25) was used to evaluate HRQoL. most (58%) reported the use of 80% or more of the prescribed dose and care in utilizing the medication. The item stopping the drug when experiencing an adverse event, from the Morisky Scale, explained 12.8% and 13.5% of the variability of adherence proportion to antihypertensives and oral antidiabetics/insulin, respectively. there was better HRQoL in the Color Vision, Driving and Social Functioning domains of the NEI VFQ-25. Individuals with lower scores on the NEI VFQ-25 and higher scores on the Morisky Scale presented greater chance to be nonadherent to the pharmacological treatment of diabetes and hypertension.
Resumo:
To assess sexual function (SF) and quality of life (QOL) in women with polycystic ovary syndrome (PCOS). A cross-sectional study was conducted to assess 56 women with PCOS and 102 control women with regular menstrual cycles. To assess SF and QOL in Brazilian women with PCOS with Female Sexual Function Index (FSFI) and the WHOQOL-bref questionnaires. Women with PCOS had a worse evaluation to arousal, lubrication, satisfaction, pain and total FSFI, and there was no difference in sexual desire and orgasm. Besides, they had a worse evaluation concerning health status than controls. The body mass index was inversely correlated to the QOL, especially to the physical, psychological, environment aspects and self-assessment of QOL, but it did not show correlation to the SF. Women with PCOS had a worse sexual function and self-assessment of health condition in comparison to controls. The body weight as isolated symptom was correlated to the worsening in quality of life, but not with the worsening of sexual function.
Resumo:
Introductions: In the care of hypertension, it is important that health professionals possess available tools that allow evaluating the impairment of the health-related quality of life, according to the severity of hypertension and the risk for cardiovascular events. Among the instruments developed for the assessment of health-related quality of life, there is the Mini-Cuestionario of Calidad de Vida en la Hipertensión Arterial (MINICHAL) recently adapted to the Brazilian culture. Objective: To estimate the validity of known groups of the Brazilian version of the MINICHAL regarding the classification of risk for cardiovascular events, symptoms, severity of dyspnea and target-organ damage. Methods: Data of 200 hypertensive outpatients concerning sociodemographic and clinical information and health-related quality of life were gathered by consulting the medical charts and the application of the Brazilian version of MINICHAL. The Mann-Whitney test was used to compare health-related quality of life in relation to symptoms and target-organ damage. The Kruskal-Wallis test and ANOVA with ranks transformation were used to compare health-related quality of life in relation to the classification of risk for cardiovascular events and intensity of dyspnea, respectively. Results: The MINICHAL was able to discriminate health-related quality of life in relation to symptoms and kidney damage, but did not discriminate health-related quality of life in relation to the classification of risk for cardiovascular events. Conclusion: The Brazilian version of the MINICHAL is a questionnaire capable of discriminating differences on the health‑related quality of life regarding dyspnea, chest pain, palpitation, lipothymy, cephalea and renal damage.Fundamento: No cuidado ao hipertenso, é importante que o profissional de saúde disponha de ferramentas que possibilitem avaliar o comprometimento da qualidade de vida relacionada à saúde, de acordo com a gravidade da hipertensão e o risco para eventos cardiovasculares. Dentre os instrumentos criados para avaliação da qualidade de vida relacionada à saúde, destaca-se o Mini-Cuestionario de Calidad de Vida en la Hipertensión Arterial (MINICHAL), recentemente adaptado para a cultura brasileira. Objetivo: Estimar a validade de grupos conhecidos da versão brasileira do MINICHAL em relação à classificação de risco para eventos cardiovasculares, sintomas, intensidade da dispneia e lesões de órgãos-alvo. Métodos: Foram investigados 200 hipertensos em seguimento ambulatorial, cujos dados sociodemográficos, clínicos e de qualidade de vida relacionada à saúde foram obtidos por meio de consulta ao prontuário e da aplicação da versão brasileira do MINICHAL. O teste de Mann-Whitney foi utilizado para comparar qualidade de vida relacionada à saúde em relação aos sintomas e às lesões de órgãos-alvo. Teste de Kruskal-Wallis e ANOVA com transformação nos ranks foram empregados para comparar qualidade de vida relacionada à saúde em relação à classificação de risco para eventos cardiovasculares e intensidade da dispneia, respectivamente. Resultados: O MINICHAL discriminou qualidade de vida relacionada à saúde em relação aos sintomas e dano renal (lesões de órgãos-alvo), porém não discriminou qualidade de vida relacionada à saúde em relação à classificação de risco para eventos cardiovasculares. Conclusão: A versão brasileira do MINICHAL é um instrumento capaz de discriminar diferenças na qualidade de vida relacionada à saúde em relação aos sintomas de dispneia, precordialgia, palpitação, lipotímia, cefaleia e presença de dano renal.
Resumo:
to compare the general and specific health-related quality of life (HRQoL) between the Intervention (IG) and Control (CG) groups of coronary artery disease patients after the implementation of Action Planning and Coping Planning strategies for medication adherence and to verify the relationship between adherence and HRQoL. this was a controlled and randomized study. the sample (n=115) was randomized into two groups, IG (n=59) and CG (n=56). Measures of medication adherence and general and specific HRQoL were obtained in the baseline and after two months of monitoring. the findings showed that the combination of intervention strategies - Action Planning and Coping Planning for medication adherence did not affect the HRQoL of coronary artery disease patients in outpatient monitoring.
Resumo:
This study aimed to check for any significant differences in perceived quality of life, specifically aspects of a physical nature, among volunteers who are more physically active and those less physically active in a university community. The sample consisted of 1,966 volunteers in a university community in Brazil. To assess physical activity levels, volunteers responded to the International Physical Activity Questionnaire (IPAQ), and to analyse the perception of quality of life they responded to WHOQOL-bref, which is classified into three groups according to level of physical activity, taking into account the metabolic equivalent index (MET) over a full week. For comparison, consideration was given to the first and third tertiles, respectively, namely groups of more and less active students. The results indicated that individuals who engaged in more physical activity had a more positive perception of quality of life compared to those who were less active in physical aspects related to the ability to work, energy for day-to-day activities and locomotion.
Resumo:
INTRODUCTION:proctocolectomy with ileal pouch-anal anastomosis (IPAA) is the standard surgical procedure for the treatment of ulcerative colitis (UC) and is associated with the prospect of cure. Experience gained over the years has demonstrated the occurrence of a high number of complications as well as bowel disorders that can compromise quality of life (QoL).OBJECTIVE:evaluate QoL in patients with IPAA for ulcerative colitis.PATIENTS AND METHODS:the Inflammatory Bowel Disease Questionnaire (IBDQ) was used to assess QoL in patients with IPAA after its validation in Portuguese.RESULTS:thirty-one patients submitted to IPAA by the same group of professionals were evaluated. QoL was classified as regular in all domains evaluated (intestinal and systemic symptoms and emotional and social aspects). There were no differences in relation to gender, type of pouch or postoperative time. However, elderly patients showed a tendency toward lower scores. Having a professional activity was associated with higher scores in systemic symptoms and social aspects (p < 0.05). Patients with ileostomy showed lower values in the domains of systemic symptoms, emotional and social aspects (p <0.05).CONCLUSION:in all domains assessed, patients with IPAA for UC had QoL classified as regular. Ileostomy and lack of professional activity negatively influenced QoL.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
PURPOSE: This study evaluated the quality of DNA obtained from stored human saliva and its applicability to human identification. METHODS: The saliva samples of 20 subjects, collected in the form of saliva in natura and from mouth swabs and stored at -20ºC, were analyzed. After 7 days, the DNA was extracted from the 40 saliva samples and subjected to PCR and electrophoresis. After 180 days, the technique was repeated with the 20 swab samples. RESULTS: The first-stage results indicated that DNA was successfully extracted in 97.5% of reactions, 95% of saliva in natura and 100% of swab saliva samples, with no statistically significant difference between the forms of saliva. In the second phase, the result was positive for all 20 analyzed samples (100%). Subsequently, in order to analyze the quality of the DNA obtained from human saliva, the SIX3-2 gene was tested on the 20 mouth swab samples, and the PCR products were digested using the MbO1 restriction enzyme to evaluate polymorphisms in the ADRA-2 gene, with positive results for most samples. CONCLUSION: It was concluded that the quantity and quality of DNA from saliva and the techniques employed are adequate for forensic analysis of DNA.
Resumo:
INTRODUÇÃO: apesar da colagem direta despender menor tempo clínico, com maior preservação da integridade gengival, ainda hoje se observa uma alta incidência de bandagem dos molares. Portanto, torna-se interessante a idealização de recursos para o aumento da eficiência desse procedimento para dentes submetidos a maiores impactos mastigatórios, como, por exemplo, os molares. OBJETIVO: esse estudo teve o propósito de avaliar se a resistência à adesão com a aplicação de uma camada de resina adicional na região oclusal da interface tubo/dente aumenta a qualidade do procedimento de colagem direta de tubos em molares. MÉTODOS: selecionou-se uma amostra composta por 40 terceiros molares inferiores, que foram aleatoriamente divididos em 2 grupos: Grupo 1 - colagem direta convencional, seguida pela aplicação de uma camada de resina na oclusal da interface tubo/dente; e Grupo 2 - colagem direta convencional. O teste de resistência ao cisalhamento foi realizado 24 horas após a colagem, utilizando-se uma máquina de ensaio universal, operando a uma velocidade de 0,5mm/min. Os resultados foram analisados por meio do teste t independente. RESULTADOS: os valores médios obtidos nos testes de cisalhamento foram: 17,08MPa para o Grupo 1 e 12,60MPa para o Grupo 2. O Grupo 1 apresentou uma resistência ao cisalhamento estatisticamente significativa mais alta do que o Grupo 2. CONCLUSÃO: a aplicação de uma camada adicional de resina na oclusal da interface tubo/dente aumenta a qualidade da adesão do procedimento de colagem direta de tubos ortodônticos em molares.
Resumo:
This study evaluated in vitro the shear bond strength of a resin-based pit-and-fissure sealant (Fluroshield - F) associated with either an ethanol-based (Adper Single Bond 2 - SB) or an acetone-based (Prime & Bond - PB) adhesive system under conditions of oil contamination. Mesial and distal enamel surfaces from 30 sound third molars were randomly assigned to 2 groups (n=30): I - no oil contamination; II - oil contamination. Contamination (0.25 mL during 10 s) was performed after 37% phosphoric acid etching with an air/oil spray. The specimens were randomly assigned to subgroups, according to the bonding protocol adopted: subgroup A - F was applied to enamel without an intermediate bonding agent layer; In subgroups B and C, SB and PB, respectively, were applied, light-cured, and then F was applied and light-cured. Shear bond strength was tested at a crosshead speed of 0.5 mm/min in a universal testing machine. Means (± SD) in MPa were: IA-11.28 (±1.84); IIA-12.02 (±1.15); IB-9.73 (±2.38); IIB-9.62 (±2.29); IC-28.30 (±1.63); and IIC-25.50 (±1.91). It may be concluded that the oil contamination affected negatively the sealant bonding to enamel and the acetone-based adhesive system (PB) layer applied underneath the sealant was able to prevent its deleterious effects to adhesion.
Resumo:
The purpose of this study was to evaluate the dentin shear bond strength of four adhesive systems (Adper Single Bond 2, Adper Prompt L-Pop, Magic Bond DE and Self Etch Bond) in regards to buccal and lingual surfaces and dentin depth. Forty extracted third molars had roots removed and crowns bisected in the mesiodistal direction. The buccal and lingual surfaces were fixed in a PVC/acrylic resin ring and were divided into buccal and lingual groups assigned to each selected adhesive. The same specimens prepared for the evaluation of superficial dentin shear resistance were used to evaluate the different depths of dentin. The specimens were identified and abraded at depths of 0.5, 1.0, 1.5 and 2.0 mm. Each depth was evaluated by ISO TR 11405 using an EMIC-2000 machine regulated at 0.5 mm/min with a 200 Kgf load cell. We performed statistical analyses on the results (ANOVA, Tukey and Scheffé tests). Data revealed statistical differences (p < 0.01) in the adhesive and depth variation as well as adhesive/depth interactions. The Adper Single Bond 2 demonstrated the highest mean values of shear bond strength. The Prompt L-Pop product, a self-etching adhesive, revealed higher mean values compared with Magic Bond DE and Self Etch Bond adhesives, a total and self-etching adhesive respectively. It may be concluded that the shear bond strength of dentin is dependent on material (adhesive system), substrate depth and adhesive/depth interaction.
Resumo:
This study evaluated the effect of chemical and mechanical surface treatments for cast metal alloys on the bond strength of an indirect composite resin (Artglass) to commercially pure titanium (cpTi). Thirty cylindrical metal rods (3 mm diameter x 60 mm long) were cast in grade-1 cpTi and randomly assigned to 6 groups (n=5) according to the received surface treatment: sandblasting; chemical treatment; mechanical treatment - 0.4 mm beads; mechanical treatment - 0.6 mm beads; chemical/mechanical treatment - 0.4 mm; and chemical/mechanical treatment - 0.6 mm beads. Artglass rings (6.0 mm diameter x 2.0 mm thick) were light cured around the cpTi rods, according manufacturer's specifications. The specimens were invested in hard gypsum and their bond strength (in MPa) to the rods was measured at fracture with a universal testing machine at a crosshead speed of 2.0 mm/min and 500 kgf load cell. Data were analyzed statistically by one-way ANOVA and Tukey test (a=5%). The surface treatments differed significantly from each other (p<0.05) regarding the recorded bond strengths. Chemical retention and sandblasting showed statistically similar results to each other (p=0.139) and both had significantly lower bond strengths (p<0.05) than the other treatments. In conclusion, mechanical retention, either associated or not to chemical treatment, provided higher bond strength of the indirect composite resin to cpTi.
Resumo:
Caffeine induces loss of calcium and influences the normal development of bone. This study investigated the effects of coffee on bone metabolism in rats by biochemical measurement of calcium, bone densitometry and histometry. Male rats, born of female treated daily with coffee and with coffee intake since born, were anesthetized, subjected to extraction of the upper right incisor, and sacrificed 7, 21 and 42 days after surgery. Blood and urine samples were taken, and their maxilla radiographed and processed to obtain 5-µm-thick semi-serial sections stained with hematoxylin and eosin. The volume and bone quality were estimated using an image-analysis software. The results showed significantly greater amount of calcium in the plasma (9.40 ± 1.73 versus 9.80 ± 2.05 mg%) and urine (1.00 ± 0.50 versus 1.25 ± 0.70 mg/24 h) and significantly less amount in bone (90.0 ± 1.94 versus 86.0 ± 2.12 mg/mg bone), reduced bone mineral density (1.05 ± 0.11 versus 0.65 ± 0.15 mmAL), and lower amount of bone (76.19 ± 1.6 versus 53.41 ± 2.1 %) (ANOVA; p≤0.01) in animals treated with coffee sacrificed after 42 days. It may be concluded that coffee/caffeine intake caused serious adverse effects on calcium metabolism in rats, including increased levels of calcium in the urine and plasma, decreased bone mineral density and lower volume of bone, thus delaying the bone repair process.
Resumo:
OBJECTIVE: The aim of this study was to evaluate the morphology of glass (GF), carbon (CF) and glass/carbon (G/CF) fiber posts and their bond strength to self or dual-cured resin luting agents. MATERIAL AND METHODS: Morphological analysis of each post type was conducted under scanning electron microscopy (SEM). Bond strength was evaluated by microtensile test after bisecting the posts and re-bonding the two halves with the luting agents. Data were subjected to two-way ANOVA and Tukey's test (α=0.05). Failure modes were evaluated under optical microscopy and SEM. RESULTS: GF presented wider fibers and higher amount of matrix than CF, and G/CF presented carbon fibers surrounded by glass fibers, and both involved by matrix. For CF and GF, the dual-cured material presented significantly higher (p<0.05) bond strength than the self-cured agent. For the dual agent, CF presented similar bond strength to GF (p>0.05), but higher than that of G/CF (p<0.05). For the self-cured agent, no significant differences (p>0.05) were detected, irrespective of the post type. For GF and G/CF, all failures were considered mixed, while a predominance of adhesive failures was detected for CF. CONCLUSION: The bonding between fiber posts and luting agents was affected by the type of fibers and polymerization mode of the cement. When no surface treatment of the post is performed, the bonding between glass fiber post and dual-cured agent seems to be more reliable.