745 resultados para bench-kokoluokka


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Whole tumor lysates are promising antigen sources for dendritic cell (DC) therapy as they contain many relevant immunogenic epitopes to help prevent tumor escape. Two common methods of tumor lysate preparations are freeze-thaw processing and UVB irradiation to induce necrosis and apoptosis, respectively. Hypochlorous acid (HOCl) oxidation is a new method for inducing primary necrosis and enhancing the immunogenicity of tumor cells. EXPERIMENTAL DESIGN: We compared the ability of DCs to engulf three different tumor lysate preparations, produce T-helper 1 (TH1)-priming cytokines and chemokines, stimulate mixed leukocyte reactions (MLR), and finally elicit T-cell responses capable of controlling tumor growth in vivo. RESULTS: We showed that DCs engulfed HOCl-oxidized lysate most efficiently stimulated robust MLRs, and elicited strong tumor-specific IFN-γ secretions in autologous T cells. These DCs produced the highest levels of TH1-priming cytokines and chemokines, including interleukin (IL)-12. Mice vaccinated with HOCl-oxidized ID8-ova lysate-pulsed DCs developed T-cell responses that effectively controlled tumor growth. Safety, immunogenicity of autologous DCs pulsed with HOCl-oxidized autologous tumor lysate (OCDC vaccine), clinical efficacy, and progression-free survival (PFS) were evaluated in a pilot study of five subjects with recurrent ovarian cancer. OCDC vaccination produced few grade 1 toxicities and elicited potent T-cell responses against known ovarian tumor antigens. Circulating regulatory T cells and serum IL-10 were also reduced. Two subjects experienced durable PFS of 24 months or more after OCDC. CONCLUSIONS: This is the first study showing the potential efficacy of a DC vaccine pulsed with HOCl-oxidized tumor lysate, a novel approach in preparing DC vaccine that is potentially applicable to many cancers. Clin Cancer Res; 19(17); 4801-15. ©2013 AACR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION. The role of turbine-based NIV ventilators (TBV) versus ICU ventilators with NIV mode activated (ICUV) to deliver NIV in case of severe respiratory failure remains debated. OBJECTIVES. To compare the response time and pressurization capacity of TBV and ICUV during simulated NIV with normal and increased respiratory demand, in condition of normal and obstructive respiratory mechanics. METHODS. In a two-chamber lung model, a ventilator simulated normal (P0.1 = 2 mbar, respiratory rate RR = 15/min) or increased (P0.1 = 6 mbar, RR = 25/min) respiratory demand. NIV was simulated by connecting the lung model (compliance 100 ml/mbar; resistance 5 or 20 l/mbar) to a dummy head equipped with a naso-buccal mask. Connections allowed intentional leaks (29 ± 5 % of insufflated volume). Ventilators to test: Servo-i (Maquet), V60 and Vision (Philips Respironics) were connected via a standard circuit to the mask. Applied pressure support levels (PSL) were 7 mbar for normal and 14 mbar for increased demand. Airway pressure and flow were measured in the ventilator circuit and in the simulated airway. Ventilator performance was assessed by determining trigger delay (Td, ms), pressure time product at 300 ms (PTP300, mbar s) and inspiratory tidal volume (VT, ml) and compared by three-way ANOVA for the effect of inspiratory effort, resistance and the ventilator. Differences between ventilators for each condition were tested by oneway ANOVA and contrast (JMP 8.0.1, p\0.05). RESULTS. Inspiratory demand and resistance had a significant effect throughout all comparisons. Ventilator data figure in Table 1 (normal demand) and 2 (increased demand): (a) different from Servo-i, (b) different from V60.CONCLUSION. In this NIV bench study, with leaks, trigger delay was shorter for TBV with normal respiratory demand. By contrast, it was shorter for ICUV when respiratory demand was high. ICUV afforded better pressurization (PTP 300) with increased demand and PSL, particularly with increased resistance. TBV provided a higher inspiratory VT (i.e., downstream from the leaks) with normal demand, and a significantly (although minimally) lower VT with increased demand and PSL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Using a bench test model, we investigated the hypothesis that neonatal and/or adult ventilators equipped with neonatal/pediatric modes currently do not reliably administer pressure support (PS) in neonatal or pediatric patient groups in either the absence or presence of air leaks. METHODS: PS was evaluated in 4 neonatal and 6 adult ventilators using a bench model to evaluate triggering, pressurization, and cycling in both the absence and presence of leaks. Delivered tidal volumes were also assessed. Three patients were simulated: a preterm infant (resistance 100 cm H2O/L/s, compliance 2 mL/cm H2O, inspiratory time of the patient [TI] 400 ms, inspiratory effort 1 and 2 cm H2O), a full-term infant (resistance 50 cm H2O/L/s, compliance 5 mL/cm H2O, TI 500 ms, inspiratory effort 2 and 4 cm H2O), and a child (resistance 30 cm H2O/L/s, compliance 10 mL/cm H2O, TI 600 ms, inspiratory effort 5 and 10 cm H2O). Two PS levels were tested (10 and 15 cm H2O) with and without leaks and with and without the leak compensation algorithm activated. RESULTS: Without leaks, only 2 neonatal ventilators and one adult ventilator had trigger delays under a given predefined acceptable limit (1/8 TI). Pressurization showed high variability between ventilators. Most ventilators showed TI in excess high enough to seriously impair patient-ventilator synchronization (> 50% of the TI of the subject). In some ventilators, leaks led to autotriggering and impairment of ventilation performance, but the influence of leaks was generally lower in neonatal ventilators. When a noninvasive ventilation algorithm was available, this was partially corrected. In general, tidal volume was calculated too low by the ventilators in the presence of leaks; the noninvasive ventilation algorithm was able to correct this difference in only 2 adult ventilators. CONCLUSIONS: No ventilator performed equally well under all tested conditions for all explored parameters. However, neonatal ventilators tended to perform better in the presence of leaks. These findings emphasize the need to improve algorithms for assisted ventilation modes to better deal with situations of high airway resistance, low pulmonary compliance, and the presence of leaks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: During open heart surgery, so-called atrial chatter, a phenomenon due to right atria and/or caval collapse, is frequently observed. Collapse of the cava axis during cardiopulmonary bypass (CPB) limits venous drainage and may result downstream in reduced pump flow on (lack of volume) and upstream in increased after-load (stagnation), which in turn may both result in reduced or even inadequate end-organ perfusion. The goal of this study was to reproduce venous collapse in the flow bench. METHODS: In accordance with literature for venous anatomy, a caval tree system is designed (polyethylene, thickness 0.061 mm), which receives venous inflow from nine afferent veins. With water as medium and a preload of 4.4 mmHg, the system has an outflow of 4500 ml/min (Scenario A). After the insertion of a percutaneous venous cannula (23-Fr), the venous model is continuously served by the afferent branches in a venous test bench and venous drainage is augmented with a centrifugal pump (Scenario B). RESULTS: With gravity drainage (siphon: A), spontaneously reversible atrial chatter can be generated in reproducible fashion. Slight reduction in the outflow diameter allows for generation of continuous flow. With augmentation (B), irreversible collapse of the artificial vena cava occurs in reproducible fashion at a given pump speed of 2300 ± 50 RPM and a pump inlet pressure of -112 mmHg. Furthermore, bubbles form at the cannula tip despite the fact that the entire system is immersed in water and air from the environment cannot enter the system. This phenomenon is also known as cavitation and should be avoided because of local damage of both formed blood elements and endothelium, as well embolization. CONCLUSIONS: This caval model provides a realistic picture for the limitations of flow due to spontaneously reversible atrial chatter vs irreversible venous collapse for a given negative pressure during CPB. Temporary interruption of negative pressure in the venous line can allow for recovery of venous drainage. This know-how can be used not only for testing different cannula designs, but also for further optimizing perfusion strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The reconstruction of the right ventricular outflow tract (RVOT) with valved conduits remains a challenge. The reoperation rate at 5 years can be as high as 25% and depends on age, type of conduit, conduit diameter and principal heart malformation. The aim of this study is to provide a bench model with computer fluid dynamics to analyse the haemodynamics of the RVOT, pulmonary artery, its bifurcation, and left and right pulmonary arteries that in the future may serve as a tool for analysis and prediction of outcome following RVOT reconstruction. METHODS: Pressure, flow and diameter at the RVOT, pulmonary artery, bifurcation of the pulmonary artery, and left and right pulmonary arteries were measured in five normal pigs with a mean weight of 24.6 ± 0.89 kg. Data obtained were used for a 3D computer fluid-dynamics simulation of flow conditions, focusing on the pressure, flow and shear stress profile of the pulmonary trunk to the level of the left and right pulmonary arteries. RESULTS: Three inlet steady flow profiles were obtained at 0.2, 0.29 and 0.36 m/s that correspond to the flow rates of 1.5, 2.0 and 2.5 l/min flow at the RVOT. The flow velocity profile was constant at the RVOT down to the bifurcation and decreased at the left and right pulmonary arteries. In all three inlet velocity profiles, low sheer stress and low-velocity areas were detected along the left wall of the pulmonary artery, at the pulmonary artery bifurcation and at the ostia of both pulmonary arteries. CONCLUSIONS: This computed fluid real-time model provides us with a realistic picture of fluid dynamics in the pulmonary tract area. Deep shear stress areas correspond to a turbulent flow profile that is a predictive factor for the development of vessel wall arteriosclerosis. We believe that this bench model may be a useful tool for further evaluation of RVOT pathology following surgical reconstructions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peripheral and neuraxial nerve blockades are widely used in the perioperative period. Their values to diminish acute postoperative pain are established but other important outcomes such as chronic postoperative pain, or newly, cancer recurrence, or infections could also be influenced. The long-term effects of perioperative nerve blockade are still controversial. We will review current knowledge of the effects of blocking peripheral electrical activity in different animal models of pain. We will first go over the mechanisms of pain development and evaluate which types of fibers are activated after an injury. In the light of experimental results, we will propose some hypotheses explaining the mitigated results obtained in clinical studies on chronic postoperative pain. Finally, we will discuss three major disadvantages of the current blockade: the absence of blockade of myelinated fibers, the inappropriate duration of blockade, and the existence of activity-independent mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The formation of new blood vessels, a process globally referred to as angiogenesis, occurs in a number of pathological conditions, such as cancer and chronic inflammation. Recent findings indicate that cyclooxygenase-2 (COX-2), the inducible form of the cyclooxygenase (COX) isoenzymes, acts as a potent inducer of angiogenesis. Non-steroidal anti-inflammatory drugs (NSAIDs) are classical inhibitors of COX enzymes, which are widely prescribed for the treatment of inflammation, pain and fever. Selective COX-2 inhibitors (COXIBs) have been subsequently developed with the purpose to improve the safety profile of this class of therapeutics. More recently, substantial preclinical evidence demonstrated that NSAIDS and COXIBs have anti-angiogenic properties. This newly recognized activity opens the possibility of using these drugs for the treatment of angiogenesis-dependent diseases. In this article we review the most recent advances in understanding the mechanisms by which NSAIDs and COXIBs suppress angiogenesis, and we discuss their potential clinical use as anti-angiogenic drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A metallic-sample arc-furnace was modified to synthesize fullerenes and nanotubes. The (reversible) changes and the process for producing single-wall nanotubes (SWNTs) are described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to develop a an automated bench top electronic penetrometer (ABEP) that allows performing tests with high rate of data acquisition (up to 19,600 Hz) and with variation of the displacement velocity and of the base area of cone penetration. The mechanical components of the ABEP are: a supporting structure, stepper motor, velocity reducer, double nut ball screw and six penetration probes. The electronic components of ABEP are: a "driver" to control rotation and displacement, power supply, three load cells, two software programs for running and storing data, and a data acquisition module. This penetrometer presented in compact size, portable and in 32 validation tests it proved easy to operate, and showed high resolution, high velocity in reliability in data collection. During the validation tests the equipment met the objectives, because the test results showed that the ABEP could use different sizes of cones, allowed work at different velocities, showed for velocity and displacement, were only 1.3% and 0.7%, respectively, at the highest velocity (30 mm s-1) and 1% and 0.9%, respectively for the lowest velocity (0.1 mm s-1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is remarkable the reduction in the number of medical students choosing general surgery as a career. In this context, new possibilities in the field of surgical education should be developed to combat this lack of interest. In this study, a program of surgical training based on learning with models of low-fidelity bench is designed as a complementary alternative to the various methodologies in the teaching of basic surgical skills during medical education, and to develop personal interests in career choice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to introduce the tangential microfiltration (TMF) technique on the production of orange juice (TMFJ), and compare it with pasteurised juice (control) as regards chemical composition and sensorial characteristics. We used a TMF pilot equipped with four monotubular ceramic membranes (0.1, 0.2, 0.8 and 1.4mm) arranged in series with a filtering area of 0.005 m² each. Commercial flash-pasteurised orange juice was used as the initial product. Experiments were divided into three parts: a) the characterisation of the TMF pilot; b) optimisation of operational conditions; c) production of the TMFJ. In the second part, membrane with 0.8-mm pores presented best flux followed by those with 1.4-, 0.1-, and 0.2-mm pores. However, to guarantee permeate sterility, we chose the membrane with 0.1-mm pores for TMFJ production. Initially, the orange juice was sieved in order to separate part of the pulp, being subsequently submitted to TMF. A mixture of retentate and pulp was made, and was subsequently pasteurised. We obtained the TMFJ by adding the permeate to the mixture. TMFJ presented soluble solids content (°Brix), pulp, pH, and titrable acidity similar to the initial pasteurised juice (control). Nevertheless, 28% of vitamin C was lost during the TMFJ production. According to the juice taster panel, the control juice presented best sensorial characteristics (greater aroma intensity and fruity flavour) when compared with the TMJF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This unhappy looking young girl is featured in an early black and white tintype photograph. The date, location and name of the photographer are unknown. This small tintype was in the possession of Iris Sloman Bell, of St. Catharines, Ontario. The Sloman - Bell families have descendants who are former slaves from the United States."Tintypes were the invention of Prof. Hamilton Smith of Ohio. They begin as thin sheets of iron, covered with a layer of black paint. This serves as the base for the same iodized collodion coating and silver nitrate bath used in the ambrotype process. First made in 1856, millions were produced well into the twentieth century. When tintypes were finished in the same sorts of mats and cases used for ambrotypes, it can be almost impossible to distinguish which process was used without removing the image to examine the substrate." Source: American Museum of Photography http://www.photographymuseum.com/primer.html

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relationships between vine water status, soil texture, and vine size were observed in four Niagara, Ontario Pinot noir vineyards in 2008 and 2009. The vineyards were divided into water status zones using geographic information systems (GIS) software to map the seasonal mean midday leaf water potential (,P), and dormant pruning shoot weights following the 2008 season. Fruit was harvested from all sentinel vines, bulked by water status zones and made into wine. Sensory analysis included a multidimensional sorting (MDS) task and descriptive analysis (DA) of the 2008 wines. Airborne multispectral images, with a spatial resolution of 38 cm, were captured four times in 2008 and three times in 2009, with the final flights around veraison. A semi-automatic process was developed to extract NDVI from the images, and a masking procedure was identified to create a vine-only NDVI image. 2008 and 2009 were cooler and wetter than mean years, and the range of water status zones was narrow. Yield per vine, vine size, anthocyanins and phenols were the least consistent variables. Divided by water status or vine size, there were no variables with differences between zones in all four vineyards in either year. Wines were not different between water status zones in any chemical analysis, and HPLC revealed that there were no differences in individual anthocyanins or phenolic compounds between water status zones within the vineyard sites. There were some notable correlations between vineyard and grape composition variables, and spatial trends were observed to be qualitatively related for many of the variables. The MDS task revealed that wines from each vineyard were more affected by random fermentation effects than water status effects. This was confirmed by the DA; there were no differences between wines from the water status zones within vineyard sites for any attribute. Remotely sensed NDVI (normalized difference vegetation index) correlated reasonably well with a number of grape composition variables, as well as soil type. Resampling to a lower spatial resolution did not appreciably affect the strength of correlations, and corresponded to the information contained in the masked images, while maintaining the range of values of NDVI. This study showed that in cool climates, there is the potential for using precision viticulture techniques to understand the variability in vineyards, but the variable weather presents a challenge for understanding the driving forces of that variability.