933 resultados para axial compression test
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Due to the inherent limitations of DXA, assessment of the biomechanical properties of vertebral bodies relies increasingly on CT-based finite element (FE) models, but these often use simplistic material behaviour and/or single loading cases. In this study, we applied a novel constitutive law for bone elasticity, plasticity and damage to FE models created from coarsened pQCT images of human vertebrae, and compared vertebral stiffness, strength and damage accumulation for axial compression, anterior flexion and a combination of these two cases. FE axial stiffness and strength correlated with experiments and were linearly related to flexion properties. In all loading modes, damage localised preferentially in the trabecular compartment. Damage for the combined loading was higher than cumulated damage produced by individual compression and flexion. In conclusion, this FE method predicts stiffness and strength of vertebral bodies from CT images with clinical resolution and provides insight into damage accumulation in various loading modes.
Resumo:
Computer tomography (CT)-based finite element (FE) models of vertebral bodies assess fracture load in vitro better than dual energy X-ray absorptiometry, but boundary conditions affect stress distribution under the endplates that may influence ultimate load and damage localisation under post-yield strains. Therefore, HRpQCT-based homogenised FE models of 12 vertebral bodies were subjected to axial compression with two distinct boundary conditions: embedding in polymethylmethalcrylate (PMMA) and bonding to a healthy intervertebral disc (IVD) with distinct hyperelastic properties for nucleus and annulus. Bone volume fraction and fabric assessed from HRpQCT data were used to determine the elastic, plastic and damage behaviour of bone. Ultimate forces obtained with PMMA were 22% higher than with IVD but correlated highly (R2 = 0.99). At ultimate force, distinct fractions of damage were computed in the endplates (PMMA: 6%, IVD: 70%), cortex and trabecular sub-regions, which confirms previous observations that in contrast to PMMA embedding, failure initiated underneath the nuclei in healthy IVDs. In conclusion, axial loading of vertebral bodies via PMMA embedding versus healthy IVD overestimates ultimate load and leads to distinct damage localisation and failure pattern.
Resumo:
INTRODUCTION An accurate description of the biomechanical behavior of the spine is crucial for the planning of scoliotic surgical correction as well as for the understanding of degenerative spine disorders. The current clinical assessments of spinal mechanics such as side-bending or fulcrum-bending tests rely on the displacement of the spine observed during motion of the patient. Since these tests focused solely on the spinal kinematics without considering mechanical loads, no quantification of the mechanical flexibility of the spine can be provided. METHODS A spinal suspension test (SST) has been developed to simultaneously monitor the force applied on the spine and the induced vertebral displacements. The system relies on cervical elevation of the patient and orthogonal radiographic images are used to measure the position of the vertebras. The system has been used to quantify the spinal flexibility on five AIS patients. RESULTS Based on the SST, the overall spinal flexibility varied between 0.3 °/Nm for the patient with the stiffer curve and 2 °/Nm for the less rigid curve. A linear correlation was observed between the overall spinal flexibility and the change in Cobb angle. In addition, the segmental flexibility calculated for five segments around the apex was 0.13 ± 0.07 °/Nm, which is similar to intra-operative stiffness measurements previously published. CONCLUSIONS In summary, the SST seems suitable to provide pre-operative information on the complex functional behavior and stiffness of spinal segments under physiological loading conditions. Such tools will become increasingly important in the future due to the ever-increasing complexity of the surgical instrumentation and procedures.
Resumo:
A hydrogel intervertebral disc (lVD) model consisting of an inner nucleus core and an outer anulus ring was manufactured from 30 and 35% by weight Poly(vinyl alcohol) hydrogel (PVA-H) concentrations and subjected to axial compression in between saturated porous endplates at 200 N for 11 h, 30 min. Repeat experiments (n = 4) on different samples (N = 2) show good reproducibility of fluid loss and axial deformation. An axisymmetric nonlinear poroelastic finite element model with variable permeability was developed using commercial finite element software to compare axial deformation and predicted fluid loss with experimental data. The FE predictions indicate differential fluid loss similar to that of biological IVDs, with the nucleus losing more water than the anulus, and there is overall good agreement between experimental and finite element predicted fluid loss. The stress distribution pattern indicates important similarities with the biological lVD that includes stress transference from the nucleus to the anulus upon sustained loading and renders it suitable as a model that can be used in future studies to better understand the role of fluid and stress in biological IVDs. (C) 2005 Springer Science + Business Media, Inc.
Resumo:
A reciclagem de resíduos apresenta-se como uma alternativa adequada com relação à preservação dos recursos naturais e do meio ambiente. As escórias de aciaria são resíduos siderúrgicos originados na fabricação do aço, e são geradas em grandes quantidades. Estes resíduos são estocados nos pátios siderúrgicos, onde permanecem, na sua maioria, sem qualquer destino. Normalmente, as escórias de aciaria são volumetricamente instáveis, apresentando características expansivas, e por esta razão, a aplicação das mesmas em materiais de construção torna-se restrita. Esta pesquisa tem como objetivo estudar a viabilidade técnica do uso das escórias de aciaria LD como adição em cimentos, propondo um método de estabilização por meio de granulação por resfriamento brusco destas escórias, buscando, desta forma, a eliminação do fenômeno da expansão, e visando a melhoria das características destes resíduos. No processo de estabilização, a escória líquida foi granulada em uma usina siderúrgica. Estudos complementares de granulação foram realizados nos laboratórios da UFRGS, empregando-se escórias refundidas. A granulação por resfriamento brusco favoreceu a redução do CaOlivre, a eliminação do MgO na forma de periclásio, e a eliminação do bC2S das escórias, considerados agentes causadores da expansão. No entanto, a elevada basicidade da escória LD dificulta a formação da estrutura vítrea e a separação da fração metálica após o resfriamento brusco. Foram realizados ensaios de expansão das escórias, atividade pozolânica, e resistência mecânica de argamassas com escórias granuladas. O resfriamento brusco proporcionou a eliminação da expansão e o desenvolvimento das propriedades pozolânicas/cimentícias da escória granulada. Como adição em cimentos, do ponto de vista da resistência mecânica, as argamassas compostas com escórias granuladas e clínquer apresentaram níveis de resistência à compressão axial compatíveis com as especificações referentes ao cimento Portland composto, apesar destes resultados serem inferiores aos obtidos para as argamassas de referência.
Resumo:
Aim. To investigate the biomechanical effects of zoledronic acid (ZA) on femurs of female osteoporotic rats after follow-up periods of 9 and 12 months. Methods. Eighty female Wistar rats were prospectively assessed. At 60 days of age, the animals were randomly divided into two groups: bilateral oophorectomy (O) (n=40) and sham surgery (S) (n=40). At 90 days of age, groups O and S were randomly subdivided into four groups, according to whether 0.1 mg/kg of ZA or distilled water (DW) was intraperitoneally administered: OZA (n=20), ODW (n=20), SZA (n=20), and SDW (n=20). The animals were sacrificed at 9 and 12 months after the administration of the substances, and then their right femurs were removed and analyzed biomechanically. Axial compression tests that focused on determining the maximum load (N), yield point (N), and stiffness coefficient (N/mm) of the proximal femur were performed in the biomechanical study. Results. ZA significantly increased the maximum load and yield point, reducing the stiffness coefficient concerning the oophorectomy status and follow-up period. Conclusion. Zoledronic acid, at a dose of 0.1 mg/kg, significantly increased the maximum loads and yield points and reduced the stiffness coefficients in the femurs of female rats with osteoporosis caused by bilateral oophorectomy. © 2012 Evandro Pereira Palacio et al.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)