246 resultados para atrium


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background Heart chambers rupture in blunt trauma is uncommon and is associated with a high mortality. The determinant factors, and the incidence of isolated heart chambers rupture remains undetermined. Isolated rupture of the right atrium appendage (RAA) is very rare, with 8 cases reported in the reviewed literature. The thin wall of the RAA has been presumed to render this chamber more prone to rupture in blunt trauma. Objective To report a case of isolated RAA rupture in blunt trauma, and to compare right atrium (RA) and RAA wall thickness in a necropsy study. Methods The thickness of RA and RAA wall of hearts from cadavers of fatal penetrating head trauma victims was measured. Our case of isolated RAA rupture is presented. The main findings of the 8 cases reported in the literature, and the findings of our case, were organized in a table. Result The comparison of the data showed that wall thickness of the RAA (0.53 ± 0.33 mm) was significantly thinner than that of RA (1.11 ± 0.42 mm) (p < 0.05). Comments In all these 9 cases of isolated RAA rupture, cardiac tamponade occurred, RAA rupture was diagnosed intraoperatively and sutured, and the patients survived. Main mechanisms hypothesized for heart chamber rupture include mechanical compression coincident with phases of cardiac cycle, leading to high hydrostatic pressure inside the chamber. Published series include numerous cases of RA rupture, and only a few cases of RAA rupture. Conclusion Thus, our data suggests that wall thickness is not a determinant factor for RA or RAA rupture in blunt trauma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Persistent atrial fibrillation (AF) ablation may lead to partial disconnection of the coronary sinus (CS). As a result, disparate activation sequences of the local CS versus contiguous left atrium (LA) may be observed during atrial tachycardia (AT). We aimed to evaluate the prevalence of this phenomenon and its impact on activation mapping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Current concepts of catheter ablation for atrial fibrillation (AF) commonly use three-dimensional (3D) reconstructions of the left atrium (LA) for orientation, catheter navigation, and ablation line placement. OBJECTIVES: The purpose of this study was to compare the 3D electroanatomic reconstruction (Carto) of the LA, pulmonary veins (PVs), and esophagus with the true anatomy displayed on multislice computed tomography (CT). METHODS: In this prospective study, 100 patients undergoing AF catheter ablation underwent contrast-enhanced spiral CT scan with barium swallow and subsequent multiplanar and 3D reconstructions. Using Carto, circumferential plus linear LA lesions were placed. The esophagus was tagged and integrated into the Carto map. RESULTS: Compared with the true anatomy on CT, the electroanatomic reconstruction accurately displayed the true distance between the lower PVs; the distances between left upper PV, left lower PV, right lower PV, and center of the esophagus; the longitudinal diameter of the encircling line around the funnel of the left PVs; and the length of the mitral isthmus line. Only the distances between the upper PVs, the distance between the right upper PV and esophagus, and the diameter of the right encircling line were significantly shorter on the electroanatomic reconstructions. Furthermore, electroanatomic tagging of the esophagus reliably visualized the true anatomic relationship to the LA. On multiple tagging and repeated CT scans, the LA and esophagus showed a stable anatomic relationship, without relevant sideward shifting of the esophagus. CONCLUSION: Electroanatomic reconstruction can display with high accuracy the true 3D anatomy of the LA and PVs in most of the regions of interest for AF catheter ablation. In addition, Carto was able to visualize the true anatomic relationship between the esophagus and LA. Both structures showed a stable anatomic relationship on Carto and CT without relevant sideward shifting of the esophagus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Right atrial perforation can lead to tamponade and death. Closure devices are used for sealing of shunts in the heart. We describe an indwelling catheter that caused perforation of the right atrium and was treated with a percutaneous closure device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The chest X-ray of a 61-year-old man with severe aortic and mitral stenosis revealed extensive, circularly arranged calcifications in the wall of the left atrial appendage. He died soon after admission to hospital and autopsy confirmed the atrial calcifications in association with severe mitral stenosis. Although such calcification of the left atrial wall is rare, it can be of importance because it may make the usual surgical approach to mitral valve replacement impossible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Rapid pulmonary vein (PV) activity has been shown to maintain paroxysmal atrial fibrillation (AF). We evaluated in persistent AF the cycle length (CL) gradient between PVs and the left atrium (LA) in an attempt to identify the subset of patients where PVs play an important role. METHODS AND RESULTS Ninety-seven consecutive patients undergoing first ablation for persistent AF were studied. For each PV, the CL of the fastest activation was assessed over 1 minute (PVfast) using Lasso recordings. The PV to LA CL gradient was quantified by the ratio of PVfast to LA appendage (LAA) AF CL. Stepwise ablation terminated AF in 73 patients (75%). In the AF termination group, the PVfast CL was much shorter than the LAA CL resulting in lower PVfast/LAA ratios compared with the nontermination group (71±10% versus 92±7%; P<0.001). Within the termination group, PVfast/LAA ratios were notably lower if AF terminated after PV isolation or limited adjunctive substrate ablation compared with patients who required moderate or extensive ablation (63±6% versus 75±8%; P<0.001). PVfast/LAA ratio <69% predicted AF termination after PV isolation or limited substrate ablation with 74% positive predictive value and 95% negative predictive value. After a mean follow-up of 29±17 months, freedom from arrhythmia recurrence off-antiarrhythmic drugs was achieved in most patients with PVfast/LAA ratios <69% as opposed to the remaining population (80% versus 43%; P<0.001). CONCLUSIONS The PV to LA CL gradient may identify the subset of patients in whom persistent AF is likely to terminate after PV isolation or limited substrate ablation and better long-term outcomes are achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Autore Henrico Opitio

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.