997 resultados para artificial heart pump


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The long-standing Acid Growth Theory of plant cell elongation posits that auxin promotes cell elongation by stimulating cell wall acidification and thus expansin action. To date, the paucity of pertinent genetic materials has precluded thorough analysis of the importance of this concept in roots. The recent isolation of mutants of the model grass species Brachypodium distachyon with dramatically enhanced root cell elongation due to increased cellular auxin levels has allowed us to address this question. We found that the primary transcriptomic effect associated with elevated steady state auxin concentration in elongating root cells is upregulation of cell wall remodeling factors, notably expansins, while plant hormone signaling pathways maintain remarkable homeostasis. These changes are specifically accompanied by reduced cell wall arabinogalactan complexity but not by increased proton excretion. On the contrary, we observed a tendency for decreased rather than increased proton extrusion from root elongation zones with higher cellular auxin levels. Moreover, similar to Brachypodium, root cell elongation is, in general, robustly buffered against external pH fluctuation in Arabidopsis thaliana However, forced acidification through artificial proton pump activation inhibits root cell elongation. Thus, the interplay between auxin, proton pump activation, and expansin action may be more flexible in roots than in shoots.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

BACKGROUND: Determining a specific death cause may facilitate individualized therapy in patients with heart failure (HF). Cardiac resynchronization therapy (CRT) decreased mortality in the Cardiac Resynchronization in Heart Failure trial by reducing pump failure and sudden cardiac death (SCD). This study analyzes predictors of specific causes of death. METHODS AND RESULTS: Univariate and multivariate analyses used 8 baseline and 3-month post-randomization variables to predict pump failure and SCD (categorized as "definite," "probable," and "possible"). Of 255 deaths, 197 were cardiovascular. There were 71 SCDs with a risk reduction by CRT of 0.47 (95% confidence interval 0.29-0.76; P = .002) with similar reductions in SCD classified as definite, probable, and possible. Univariate SCD predictors were 3-month HF status (mitral regurgitation [MR] severity, plasma brain natriuretic peptide [BNP], end-diastolic volume, and systolic blood pressure), whereas randomization to CRT decreased risk. Multivariate SCD predictors were randomization to CRT 0.56 (0.53-0.96, P = .035) and 3-month MR severity 1.82 (1.77-2.60, P = .0012). Univariate pump failure death predictors related to baseline HF state (quality of life score, interventricular mechanical delay, end-diastolic volume, plasma BNP, MR severity, and systolic pressure), whereas randomization to CRT and nonischemic cardiomyopathy decreased risk; multivariate predictors of pump failure death were baseline plasma BNP and systolic pressure and randomization to CRT. CONCLUSION: CRT decreased SCD in patients with systolic HF and ventricular dyssynchrony. SCD risk was increased with increased severity of MR (including the 3-month value for MR as a time-dependent covariate) and reduced by randomization to CRT. HF death was increased related to the level of systolic blood pressure, log BNP, and randomization to CRT. These results emphasize the importance and interdependence of HF severity to mortality from pump failure and SCD.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: The RCP is a 14 French collapsable percutaneous cardiovascular support device positioned in the descending part of the thoracic aorta via the femoral artery. A 10 patient first in man study demonstrated device safety and significant improvement in renal function among high risk PCI patients. We now report haemodynamic and renal efficacy in patients with ADHF.Methods: Prospective non randomised study seeking to recruit 20 patients with ADHF with a need for inotropic or mechanical circulatory support with: i) EF < 30% ii)Cardiac index(CI) < 2.2 L / min / m2 Outcome measures included: 1) Cardiac index (CI) 2) Pulmonary Capillary Wedge Pressure (PCWP) 3) Urine output / serum creatinine 4) Vascular / device complications 5) 30 day mortalityResults: INTERIM ANALYSIS (n=12) The mean age of the study group was 64 years, with a mean baseline creatinine of 193 umol/L, eGFR 38 ml/min. The intended RCP treatment period was 24 hours. During RCP treatment there was a significant mean reduction of PCWP at 4 hours of 17% (25 to 21 mmHg p=0.04). Mean CI increased at 12 hours by 11%, though not reaching significance (1.78 to 1.96 L/min/m2 p=0.08). RCP insertion prompted substantial diuresis. Urine output tripled over the first 12 hours compared to baseline (55 ml/hr vs 213 ml/hr p=0.03). This was associated with significantly improved renal function, a 28% reduction in serum creatinine at 12 hours (193 to 151 umol/L p=0.003), and a increase in eGFR from 38 ml/min to 50 ml/min (p=0.0007). 2 patients previously refused cardiac transplantation were reassessed and successfully transplanted within 9 months of RCP treatment on the basis of demonstrable renal reversibility. There were no vascular or device complications. There were 2 deaths at 30 days, one from multi-organ failure and sepsis, and one from intractable heart failure - neither were device related.Conclusion: RCP support in ADHF patients was associated with improved haemodynamics, and an improvement in renal function. The Reitan Catheter Pump may have a role in providing percutaneous cardiovascular and renal support in the acutely decompensated cardiac patient, and may have a role in suggesting renal reversibility in potential cardiac transplant patients. Further data will be reported at recruitment completion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Half of the patients with end-stage heart failure suffer from persistent atrial fibrillation (AF). Atrial kick (AK) accounts for 10-15% of the ejection fraction. A device restoring AK should significantly improve cardiac output (CO) and possibly delay ventricular assist device (VAD) implantation. This study has been designed to assess the mechanical effects of a motorless pump on the right chambers of the heart in an animal model. METHODS: Atripump is a dome-shaped biometal actuator electrically driven by a pacemaker-like control unit. In eight sheep, the device was sutured onto the right atrium (RA). AF was simulated with rapid atrial pacing. RA ejection fraction (EF) was assessed with intracardiac ultrasound (ICUS) in baseline, AF and assisted-AF status. In two animals, the pump was left in place for 4 weeks and then explanted. Histology examination was carried out. The mean values for single measurement per animal with +/-SD were analysed. RESULTS: The contraction rate of the device was 60 per min. RA EF was 41% in baseline, 7% in AF and 21% in assisted-AF conditions. CO was 7+/-0.5 l min(-1) in baseline, 6.2+/-0.5 l min(-1) in AF and 6.7+/-0.5 l min(-1) in assisted-AF status (p<0.01). Histology of the atrium in the chronic group showed chronic tissue inflammation and no sign of tissue necrosis. CONCLUSIONS: The artificial muscle restores the AK and improves CO. In patients with end-stage cardiac failure and permanent AF, if implanted on both sides, it would improve CO and possibly delay or even avoid complex surgical treatment such as VAD implantation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Atripump is a motorless, volume displacement pump based on artificial muscle technology that could reproduce the pump function of normal atrium. It could help prevent blood clots due to blood stagnation and eventually avoid anticoagulation therapy in atrial fibrillation (AF). An animal study has been designed to assess mechanical effects of this pump on fibrillating atrium. The Atripump is a dome shaped silicone coated nitinol actuator. A pacemaker like control unit drives the actuator. In five adult sheep, the right atrium (RA) was exposed and dome sutured onto the epicardium. Atrial fibrillation was induced using rapid epicardial pacing (600 beats/min). Ejection fraction of the RA was obtained with intracardiac ultrasound in baseline, AF and Atripump assisted AF conditions. The dome's contraction rate was 60/min with power supply of 12V, 400 mA for 200 ms and ran for 2 hours in total. Mean temperature on the RA was 39+/-1.5 degrees C. Right atrium ejection fraction was 31% in baseline conditions, 5% and 20% in AF and assisted AF, respectively. In two animals a thrombus appeared in the right appendix and washed out once the pump was turned on. The Atripump washes blood out the RA acting as an anticoagulant device. Possible clinical implications in patients with chronic AF are prevention of embolism of cardiac origin and avoidance of hemorrhagic complication due to chronic anticoagulation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Cardiopulmonary bypass (CPB) with aortic cross-clamping and cardioplegic arrest remains the method of choice for patients requiring standard myocardial revascularization. Therefore, very high-risk patients presenting with acute coronary syndrome, unstable angina, onset of cardiac decompensation and requiring emergency multiple myocardial revascularization, can have a poor outcome. The on-pump beating heart technique can reduce the mortality and the morbidity in such a selected group of patients and this report describes our clinical experience. METHODS: Out of 290 patients operated for CABG from January 2005 to January 2006, 25 (8.6%) selected high-risk patients suffering from life threatening coronary syndrome (mean age 69 +/- 7 years) and requiring emergency multiple myocardial revascularization, underwent on-pump beating heart surgery. The mean pre-operative left ventricle ejection fraction (LVEF) was 27 +/- 8%. The majority of them (88%) suffered of tri-vessel coronary disease and 6 (24%) had a left main stump disease. Nine patients (35%) were on severe cardiac failure and seven among them (28%) received a pre-operative intra-aortic balloon pump. The pre-operative EuroScore rate was equal or above 8 in 18 patients (73%). RESULTS: All patients underwent on-pump-beating heart coronary revascularization. The mean number of graft/patient was 2.9 +/- 0.6 and the internal mammary artery was used in 23 patients (92%). The mean CPB time was 84 +/- 19 minutes. Two patients died during the recovery stay in the intensive care unit, and there were no postoperative myocardial infarctions between the survivors. Eight patients suffered of transitorily renal failure and 1 patient developed a sternal wound infection. The mean hospital stay was 12 +/- 7 days. The follow-up was complete for all 23 patients survived at surgery and the mean follow-up time was 14 +/- 5 months. One patient died during the follow-up for cardiac arrest and 2 patients required an implantable cardiac defibrillator. One year after surgery they all had a standard trans-thoracic echocardiogram showing a mean LVEF rate of 36 +/- 11.8%. CONCLUSION: Standard on-pump arrested heart coronary surgery has higher mortality and morbidity in emergencies. The on-pump beating heart myocardial revascularization seems to be a valid alternative for the restricted and selected cohort of patients suffering from life threatening coronary syndrome and requiring multiple emergency CABG.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We describe a device made of artificial muscle for the treatment of end-stage heart failure as an alternative to current heart assist devices. The key component is a matrix of nitinol wires and aramidic fibers called Biometal muscle (BM). When heated electrically, it produces a motorless, smooth, and lifelike motion. The BM is connected to a carbon fiber scaffold, tightening the heart and providing simultaneous assistance to the left and right ventricles. A pacemaker-like microprocessor drives the contraction of the BM. We tested the device in a dedicated bench model of diseased heart. It generated a systolic pressure of 75 mm Hg and ejected a maximum of 330 ml/min, with an ejection fraction of 12%. The device required a power supply of 6 V, 250 mA. This could be the beginning of an era in which BMs integrate or replace the mechanical function of natural muscles.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A carrier system for gases and nutrients became mandatory when primitive animals grew larger and developed different organs. The first circulatory systems are peristaltic tubes pushing slowly the haemolymph into an open vascular tree without capillaries (worms). Arthropods developed contractile bulges on the abdominal aorta assisted by accessory hearts for wings or legs and by abdominal respiratory motions. Two-chamber heart (atrium and ventricle) appeared among mollusks. Vertebrates have a multi-chamber heart and a closed circulation with capillaries. Their heart has two chambers in fishes, three chambers (two atria and one ventricle) in amphibians and reptiles, and four chambers in birds and mammals. The ventricle of reptiles is partially divided in two cavities by an interventricular septum, leaving only a communication of variable size leading to a variable shunt. Blood pressure increases progressively from 15 mmHg (worms) to 170/70 mmHg (birds) according to the increase in metabolic rate. When systemic pressure exceeds 50 mmHg, a lower pressure system appears for the circulation through gills or lungs in order to improve gas exchange. A four-chamber heart allows a complete separation of systemic and pulmonary circuits. This review describes the circulatory pumping systems used in the different classes of animals, their advantages and failures, and the way they have been modified with evolution.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In some high-risk patients, standard mitral valve replacement can represent a challenging procedure, requiring a risky extensive decalcification of the annulus. In particular, high-risk redo patients and patients with a previously implanted transcatheter aortic valve, who develop calcific mitral disease, would benefit from the development of new, minimally invasive, transcatheter or hybrid techniques for mitral valve replacement. In particular, mixing transcatheter valve therapies and well-established minimally invasive techniques for mitral replacement or repair can help in decreasing the surgical risk and the technical complexity. Thus, placing transcatheter, balloon-expandable Sapien? XT stent-valves in calcified, degenerated mitral valves through a right thoracotomy, a left atriotomy and on an on-pump fibrillating heart, represents an attractive alternative to standard surgery in redo patients, in patients with concomitant transcatheter aortic stent-valves in place and in patients with a high-risk profile. We describe this hybrid technique in detail.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Apart from its role as a flow generator for ventilation the diaphragm has a circulatory role. The cyclical abdominal pressure variations from its contractions cause swings in venous return from the splanchnic venous circulation. During exercise the action of the abdominal muscles may enhance this circulatory function of the diaphragm. Eleven healthy subjects (25 ± 7 year, 70 ± 11 kg, 1.78 ± 0.1 m, 3 F) performed plantar flexion exercise at ~4 METs. Changes in body volume (ΔVb) and trunk volume (ΔVtr) were measured simultaneously by double body plethysmography. Volume of blood shifts between trunk and extremities (Vbs) was determined non-invasively as ΔVtr-ΔVb. Three types of breathing were studied: spontaneous (SE), rib cage (RCE, voluntary emphasized inspiratory rib cage breathing), and abdominal (ABE, voluntary active abdominal expiration breathing). During SE and RCE blood was displaced from the extremities into the trunk (on average 0.16 ± 0.33 L and 0.48 ± 0.55 L, p < 0.05 SE vs. RCE), while during ABE it was displaced from the trunk to the extremities (0.22 ± 0.20 L p < 0.001, p < 0.05 RCE and SE vs. ABE respectively). At baseline, Vbs swings (maximum to minimum amplitude) were bimodal and averaged 0.13 ± 0.08 L. During exercise, Vbs swings consistently increased (0.42 ± 0.34 L, 0.40 ± 0.26 L, 0.46 ± 0.21 L, for SE, RCE and ABE respectively, all p < 0.01 vs. baseline). It follows that during leg exercise significant bi-directional blood shifting occurs between the trunk and the extremities. The dynamics and partitioning of these blood shifts strongly depend on the relative predominance of the action of the diaphragm, the rib cage and the abdominal muscles. Depending on the partitioning between respiratory muscles for the act of breathing, the distribution of blood between trunk and extremities can vary by up to 1 L. We conclude that during exercise the abdominal muscles and the diaphragm might play a role of an "auxiliary heart."

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: In previous studies cholesterol-rich nanoemulsions (LDE) resembling low-density lipoprotein were shown to concentrate in atherosclerotic lesions of rabbits. Lesions were pronouncedly reduced by treatment with paclitaxel associated with LDE. This study aimed to test the hypothesis of whether LDE-paclitaxel is able to concentrate in grafted hearts of rabbits and to ameliorate coronary allograft vasculopathy after the transplantation procedure. Methods: Twenty-one New Zealand rabbits fed 0.5% cholesterol were submitted to heterotopic heart transplantation at the cervical position. All rabbits undergoing transplantation were treated with cyclosporin A (10 mg . kg(-1) . d(-1) by mouth). Eleven rabbits were treated with LDE-paclitaxel (4 mg/kg body weight paclitaxel per week administered intravenously for 6 weeks), and 10 control rabbits were treated with 3 mL/wk intravenous saline. Four control animals were injected with LDE labeled with [(14)C]-cholesteryl oleate ether to determine tissue uptake. Results: Radioactive LDE uptake by grafts was 4-fold that of native hearts. In both groups the coronary arteries of native hearts showed no stenosis, but treatment with LDE-paclitaxel reduced the degree of stenosis in grafted hearts by 50%. The arterial luminal area in grafts of the treated group was 3-fold larger than in control animals. LDE-paclitaxel treatment resulted in a 7-fold reduction of macrophage infiltration. In grafted hearts LDE-paclitaxel treatment reduced the width of the intimal layer and inhibited the destruction of the medial layer. No toxicity was observed in rabbits receiving LDE-paclitaxel treatment. Conclusions: LDE-paclitaxel improved posttransplantation injury to the grafted heart. The novel therapeutic approach for heart transplantation management validated here is thus a promising strategy to be explored in future clinical studies. (J Thorac Cardiovasc Surg 2011;141:1522-8)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Myocardial depression after cardiac surgery is modulated by cardiopulmonary bypass (CPB) and the underlying heart disease. The sodium pump is a key component for myocardial function. We hypothesized that the change in sodium pump expression during CPB correlates with intraoperative and postoperative laboratory and clinical parameters in neonates and children with various congenital heart defects. Sodium pump isoforms alpha1 (ATP1A1) and alpha3 (ATP1A3) mRNA expression in right atrial myocardium, excised before and after CPB, was quantified. Groups were assigned according to presence (VO group, n = 8) or absence (NO group, n = 8) of right atrial volume overload. CPB and aortic clamp time correlated with postoperative troponin-I values and ICU stay. ATP1A1 (P = 0.008) and ATP1A3 (P = 0.038) mRNA expression were significantly reduced during CPB. Longer aortic clamp times were associated with lower postoperative ATP1A1 (P = 0.045) and ATP1A3 (P = 0.002) mRNA expression. Low postoperative ATP1A1 (P = 0.043) and ATP1A3 (P = 0.002) expressions were associated with high troponin-I values. These results were restricted to the VO group. No correlation of sodium pump mRNA expression was found with the duration of ICU stay or ventilation. The postoperative troponin-I and clinical parameters correlated with the length of CPB, regardless of volume overload. In contrast, only dilated right atrium seemed to be susceptible to CPB in terms of sodium pump expression, showing a reduction during the operation and a correlation of sodium pump with postoperative troponin-I values.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Extracorporeal membrane oxygenation (ECMO) was used to achieve temporary artificial support in cardiac and pulmonary function in 22 patients from 1987 to September 1990. Standard indications were postcardiotomy cardiogenic shock (n = 4), neonatal (n = 1) and adult respiratory distress syndrome (n = 4). ECMO was also used for extended indications, such as graft failure following heart (n = 11) or lung transplantation (n = 2). In six of these cases ECMO was instituted as a bridge device to subsequent retransplantation of either the heart (n = 4) or one lung (n = 2). One out of nine patients supported by ECMO for standard indications, and two out of 13 patients supported for extended indications are long-term survivors. This series illustrates the results with ECMO in emergency situations, in patients under immunosuppressive protocols, or in patients with advanced lung failure requiring almost complete artificial gas exchange. In such complex situations, ECMO does provide stabilization until additional therapeutic measures are in effect. ECMO cannot be recommended for postoperative cardiogenic shock but short-term ECMO support is an accepted method in most cases with graft failure or pulmonary failure or other origin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective Adapt the 6 minutes walking test (6MWT) to artificial gait in complete spinal cord injured (SCI) patients aided by neuromuscular electrical stimulation. Method Nine male individuals with paraplegia (AIS A) participated in this study. Lesion levels varied between T4 and T12 and time post injured from 4 to 13 years. Patients performed 6MWT 1 and 6MWT 2. They used neuromuscular electrical stimulation, and were aided by a walker. The differences between two 6MWT were assessed by using a paired t test. Multiple r-squared was also calculated. Results The 6MWT 1 and 6MWT 2 were not statistically different for heart rate, distance, mean speed and blood pressure. Multiple r-squared (r2 = 0.96) explained 96% of the variation in the distance walked. Conclusion The use of 6MWT in artificial gait towards assessing exercise walking capacity is reproducible and easy to apply. It can be used to assess SCI artificial gait clinical performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the development of a ventricular assist device, computational fluid dynamics (CFD) analysis is an efficient tool to obtain the best design before making the final prototype. In this study, different designs of a centrifugal blood pump were developed to investigate flow characteristics and performance. This study assumed the blood flow as being an incompressible homogeneous Newtonian fluid. A constant velocity was applied at the inlet; no slip boundary conditions were applied at device wall; and pressure boundary conditions were applied at the outlet. The CFD code used in this work was based on the finite volume method. In the future, the results of CFD analysis can be compared with flow visualization and hemolysis tests.