952 resultados para angular correlation coefficient


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes two similar methods for calculating gamma transition intensities from multidetector coincidence measurements. In the first one, applicable to experiments where the angular correlation function is explicitly fitted, the normalization parameter from this fit is used to determine the gamma transition intensities. In the second, that can be used both in angular correlation or DCO measurements, the spectra obtained for all the detector pairs are summed up, in order to get the best detection statistics possible, and the analysis of the resulting bidimensional spectrum is used to calculate the transition intensities; in this method, the summation of data corresponding to different angles minimizes the influence of the angular correlation coefficient. Both methods are then tested in the calculation of intensities for well-known transitions from a (152)Eu standard source, as well as in the calculation of intensities obtained in beta-decay experiments with (193)Os and (155)Sm sources, yielding excellent results in all these cases. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aSPECT spectrometer has been constructed to measure, with high precision, the integral proton spectrum of the free neutron decay. From this spectrum the neutrino electron angular correlation coefficient a can be inferred. The coefficient a is involved in several Standard Model tests, like the unitarity test of the Cabibbo-Kobayashi-Maskawa quark mixing matrix. aSPECT has been designed to determine the coefficient a with an accuracy better than 3×10−4, that is, one order of magnitude better than the best current accuracy. First measurements with neutron beam with the aSPECT spectrometer were performed in the Forschungsneutronenquelle Heinz Maier-Leibnitz, in Munich. A study of the data taken in this period is presented in this thesis, demonstrating the proof of principle of the spectrometer. However, the observation of situation and time-dependent background instabilities impedes the report of a new value of the coefficient a. A thorough data analysis is carried out to identify sources of these background instabilities in order to improve the aSPECT experiment for future beam times. The investigation indicates that trapped particles are most likely the reason for the background problems. Furthermore, it has been observed that measurements containing less trapped particles provide a-values closer to the currently Particle Data Group value. Based on this findings, different measures are proposed to eliminate potential traps in the spectrometer. Indeed, with the proposed modifications realized for the following beam-times, the observed background instabilities were greatly reduced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Das aSPECT Spektrometer wurde entworfen, um das Spektrum der Protonen beimrnZerfall freier Neutronen mit hoher Präzision zu messen. Aus diesem Spektrum kann dann der Elektron-Antineutrino Winkelkorrelationskoeffizient "a" mit hoher Genauigkeit bestimmt werden. Das Ziel dieses Experiments ist es, diesen Koeffizienten mit einem absoluten relativen Fehler von weniger als 0.3% zu ermitteln, d.h. deutlich unter dem aktuellen Literaturwert von 5%.rnrnErste Messungen mit dem aSPECT Spektrometer wurden an der Forschungsneutronenquelle Heinz Maier-Leibnitz in München durchgeführt. Jedoch verhinderten zeitabhängige Instabilitäten des Meßhintergrunds eine neue Bestimmung von "a".rnrnDie vorliegende Arbeit basiert hingegen auf den letzten Messungen mit dem aSPECTrnSpektrometer am Institut Laue-Langevin (ILL) in Grenoble, Frankreich. Bei diesen Messungen konnten die Instabilitäten des Meßhintergrunds bereits deutlich reduziert werden. Weiterhin wurden verschiedene Veränderungen vorgenommen, um systematische Fehler zu minimieren und um einen zuverlässigeren Betrieb des Experiments sicherzustellen. Leider konnte aber wegen zu hohen Sättigungseffekten der Empfängerelektronik kein brauchbares Ergebnis gemessen werden. Trotzdem konnten diese und weitere systematische Fehler identifiziert und verringert, bzw. sogar teilweise eliminiert werden, wovon zukünftigernStrahlzeiten an aSPECT profitieren werden.rnrnDer wesentliche Teil der vorliegenden Arbeit befasst sich mit der Analyse und Verbesserung der systematischen Fehler, die durch das elektromagnetische Feld aSPECTs hervorgerufen werden. Hieraus ergaben sich vielerlei Verbesserungen, insbesondere konnten die systematischen Fehler durch das elektrische Feld verringert werden. Die durch das Magnetfeld verursachten Fehler konnten sogar soweit minimiert werden, dass nun eine Verbesserung des aktuellen Literaturwerts von "a" möglich ist. Darüber hinaus wurde in dieser Arbeit ein für den Versuch maßgeschneidertes NMR-Magnetometer entwickelt und soweit verbessert, dass nun Unsicherheiten bei der Charakterisierung des Magnetfeldes soweit reduziert wurden, dass sie für die Bestimmung von "a" mit einer Genauigkeit von mindestens 0.3% vernachlässigbar sind.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Precision measurements of observables in neutron beta decay address important open questions of particle physics and cosmology. In this thesis, a measurement of the proton recoil spectrum with the spectrometer aSPECT is described. From this spectrum the antineutrino-electron angular correlation coefficient a can be derived. In our first beam time at the FRM II in Munich, background instabilities prevented us from presenting a new value for a. In the latest beam time at the ILL in Grenoble, the background has been reduced sufficiently. As a result of the data analysis, we identified and fixed a problem in the detector electronics which caused a significant systematic error. The aim of the latest beam time was a new value for a with an error well below the present literature value of 4%. A statistical accuracy of about 1.4% was reached, but we could only set upper limits on the correction of the problem in the detector electronics, too high to determine a meaningful result. This thesis focused on the investigation of different systematic effects. With the knowledge of the systematics gained in this thesis, we are able to improve aSPECT to perform a 1% measurement of a in a further beam time.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

To assess total testosterone and prostatic-specific antigen (PSA) kinetics among diverse chemical castrations, advanced-stage prostate cancer patients were randomized into three groups of 20: Group 1, Leuprolide 3.75 mg; Group 2, Leuprolide 7.5 mg; and Group 3, Goserelin 3.6 mg. All groups were treated with monthly application of the respective drugs. The patients' levels of serum total testosterone and PSA were evaluated at two time periods: before the treatment and 3 months after the treatment. Spearman's rank correlation coefficient was utilized to verify the hypothesis of linear correlation between total testosterone and PSA levels. At the beginning the patients' age, stage, grade, PSA, and total testosterone were similar within the three groups, with median age 72, 70, and 70 years in Groups 1, 2, and 3, respectively. Three months after the treatment, patients who received Leuprolide 7.5 mg presented significantly lower median total testosterone levels compared with Goserelin 3.6 mg and Leuprolide 3.75 mg (9.5 ng/dL vs. 20.0 ng/dL vs. 30.0 ng/dL, respectively; p = .0072), while those who received Goserelin 3.6 mg presented significantly lower PSA levels compared with Leuprolide 7.5 mg and Leuprolide 3.75 mg (0.67 vs. 1.86 vs. 2.57, respectively; p = .0067). There was no linear correlation between total testosterone and PSA levels. Overall, regarding castration levels of total testosterone, 28.77% of patients did not obtain levels ≤50 ng/dL and 47.80% did not obtain levels ≤20 ng/dL. There was no correlation between total testosterone and PSA kinetics and no equivalence among different pharmacological castrations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Microleakage can be related to margin misfit. Also, traditional microleakage techniques are time-consuming. This study evaluated the existence of correlation between in vitro margin fit and a new microleakage technique for complete crowns cemented with 3 different luting agents. Thirty human premolars were prepared for full-coverage crowns with a convergence angle of 6 degrees, chamfer margin of 1.2 mm circumferentially, and occlusal reduction of 1.5 mm. Ni-Cr cast crowns were cemented with either zinc phosphate (ZP) (S.S. White), resin-modified glass-ionomer (RMGI) (Rely X Luting Cement) or a resin-based luting agent (RC) (Enforce). Margin fit (seating discrepancy and margin gap) was evaluated according to criteria in the literature under microscope with 0.001 mm accuracy. After thermal cycling, crowns were longitudinally sectioned and microleakage scores at tooth-cement interface were obtained and recorded at ×100 magnification. Margin fit parameters were compared with the one-way ANOVA test and microleakage scores with Kruskal-Wallis and Dunn's tests (alpha=0.05). Correlation between margin fit and microleakage was analyzed with the Spearman's test (alpha=0.05). Seating discrepancy and marginal gap values ranged from 81.82 µm to 137.22 µm (p=0.117), and from 75.42 µm to 78.49 µm (p=0.940), respectively. Marginal microleakage scores were ZP=3.02, RMGI=0.35 and RC=0.12 (p<0.001), with no differences between RMGI and RC scores. The correlation coefficient values ranged from -0.27 to 0.30 (p>0.05). Conclusion: Margin fit parameters and microleakage showed no strong correlations; cast crowns cemented with RMGI and RC had lower microleakage scores than ZP cement.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The effects of fluctuating initial conditions are studied in the context of relativistic heavy ion collisions where a rapidly evolving system is formed. Two-particle correlation analysis is applied to events generated with the NEXSPHERIO hydrodynamic code, starting with fluctuating nonsmooth initial conditions (IC). The results show that the nonsmoothness in the IC survives the hydroevolution and can be seen as topological features of the angular correlation function of the particles emerging from the evolving system. A long range correlation is observed in the longitudinal direction and in the azimuthal direction a double peak structure is observed in the opposite direction to the trigger particle. This analysis provides clear evidence that these are signatures of the combined effect of tubular structures present in the IC and the proceeding collective dynamics of the hot and dense medium.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A quantitative correlation between the glass forming ability and the electronic parameters of metallic alloys is presented. It is found that the critical cooling rate for glass formation (R(c)) correlates well with the average work function difference (Delta phi) and the average electron density difference (Delta n(ws)(1/3)) among the constituent elements of the investigated alloys. A correlation coefficient (R(2)) of 0.77 was found for 68 alloys in 30 metallic systems, which is better than the previous proposed correlation between the glass forming ability and the average Pauling electronegativity difference.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In adolescent idiopathic scoliosis (AIS) there has been a shift towards increasing the number of implants and pedicle screws, which has not been proven to improve cosmetic correction. To evaluate if increasing cost of instrumentation correlates with cosmetic correction using clinical photographs. 58 Lenke 1A and B cases from a multicenter AIS database with at least 3 months follow-up of clinical photographs were used for analysis. Cosmetic parameters on PA and forward bending photographs included angular measurements of trunk shift, shoulder balance, rib hump, and ratio measurements of waist line asymmetry. Pre-op and follow-up X-rays were measured for coronal and sagittal deformity parameters. Cost density was calculated by dividing the total cost of instrumentation by the number of vertebrae being fused. Linear regression and spearman`s correlation were used to correlate cost density to X-ray and photo outcomes. Three independent observers verified radiographic and cosmetic parameters for inter/interobserver variability analysis. Average pre-op Cobb angle and instrumented correction were 54A degrees (SD 12.5) and 59% (SD 25) respectively. The average number of vertebrae fused was 10 (SD 1.9). The total cost of spinal instrumentation ranged from $6,769 to $21,274 (Mean $12,662, SD $3,858). There was a weak positive and statistically significant correlation between Cobb angle correction and cost density (r = 0.33, p = 0.01), and no correlation between Cobb angle correction of the uninstrumented lumbar spine and cost density (r = 0.15, p = 0.26). There was no significant correlation between all sagittal X-ray measurements or any of the photo parameters and cost density. There was good to excellent inter/intraobserver variability of all photographic parameters based on the intraclass correlation coefficient (ICC 0.74-0.98). Our method used to measure cosmesis had good to excellent inter/intraobserver variability, and may be an effective tool to objectively assess cosmesis from photographs. Since increasing cost density only improves mildly the Cobb angle correction of the main thoracic curve and not the correction of the uninstrumented spine or any of the cosmetic parameters, one should consider the cost of increasing implant density in Lenke 1A and B curves. In the area of rationalization of health care expenses, this study demonstrates that increasing the number of implants does not improve any relevant cosmetic or radiographic outcomes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Milk is the normal secretion of the mammary gland, practically free of colostrum and obtained by the complete milking of oil(? or more healthy animals. Mastitis is all inflammatory process of the mammary gland and it may cause alterations in the milk. The present work aimed to verify whether it is possible, by means of the counts of microorganism in the bulk raw milk ill four selective culture media, to establish a correlation with the occurrence of mastitis and therefore, to monitor this disease in bovine dairy herds. The following selective culture media were Used: KF Streptococcus Agar, Edwards Agar, Baird-Parker Agar, Blood Agar plus potassium tellurite. Spearman`s correlation coefficient was calculated in order to compare the Occurrence of mastitis (percentage) in each herd with respective selective culture media counts of microorganisms in bulk raw milk. Thirty-six possibilities were analysed (Tamis and CMT-positive rates were compared with the log-transformed count in four selective Culture media) and there was a negative correlation between Tamis 3 and the Baird-Parker Agar plate count. The total results of microbiological tests showed that there were three correlations of the counts in selective culture media. Fifty-two possibilities were analysed and there was a negative correlation between no-bacteria I-growth mastitis rates and log(10) of KF Streptoccocus Agar plate Count and there were two positive correlations between coagulase-positive staphylococci and log(10) of Baird-Parker Agar plate count and Blood Agar plus potassium tellurite plate count.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the performance of the turbidimetric method of C-reactive protein (CRP) as a measure of low-grade inflammation in patients admitted with non-ST elevation acute coronary syndromes (ACS). METHODS: Serum samples obtained at hospital arrival from 68 patients (66±11 years, 40 men), admitted with unstable angina or non-ST elevation acute myocardial infarction were used to measure CRP by the methods of nephelometry and turbidimetry. RESULTS: The medians of C-reactive protein by the turbidimetric and nephelometric methods were 0.5 mg/dL and 0.47 mg/dL, respectively. A strong linear association existed between the 2 methods, according to the regression coefficient (b=0.75; 95% C.I.=0.70-0.80) and correlation coefficient (r=0.96; P<0.001). The mean difference between the nephelometric and turbidimetric CRP was 0.02 ± 0.91 mg/dL, and 100% agreement between the methods in the detection of high CRP was observed. CONCLUSION: In patients with non-ST elevation ACS, CRP values obtained by turbidimetry show a strong linear association with the method of nephelometry and perfect agreement in the detection of high CRP.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: We examined the correlation between clinical wear rates of restorative materials and enamel (TRAC Research Foundation, Provo, USA) and the results of six laboratory test methods (ACTA, Alabama (generalized, localized), Ivoclar (vertical, volumetric), Munich, OHSU (abrasion, attrition), Zurich). METHODS: Individual clinical wear data were available from clinical trials that were conducted by TRAC Research Foundation (formerly CRA) together with general practitioners. For each of the n=28 materials (21 composite resins for intra-coronal restorations [20 direct and 1 indirect], 5 resin materials for crowns, 1 amalgam, enamel) a minimum of 30 restorations had been placed in posterior teeth, mainly molars. The recall intervals were up to 5 years with the majority of materials (n=27) being monitored, however, only for up to 2 years. For the laboratory data, the databases MEDLINE and IADR abstracts were searched for wear data on materials which were also clinically tested by TRAC Research Foundation. Only those data for which the same test parameters (e.g. number of cycles, loading force, type of antagonist) had been published were included in the study. A different quantity of data was available for each laboratory method: Ivoclar (n=22), Zurich (n=20), Alabama (n=17), OHSU and ACTA (n=12), Munich (n=7). The clinical results were summed up in an index and a linear mixed model was fitted to the log wear measurements including the following factors: material, time (0.5, 1, 2 and 3 years), tooth (premolar/molar) and gender (male/female) as fixed effects, and patient as random effect. Relative ranks were created for each material and method; the same was performed with the clinical results. RESULTS: The mean age of the subjects was 40 (±12) years. The materials had been mostly applied in molars (81%) and 95% of the intracoronal restorations were Class II restorations. The mean number of individual wear data per material was 25 (range 14-42). The mean coefficient of variation of clinical wear data was 53%. The only significant correlation was reached by OHSU (abrasion) with a Spearman r of 0.86 (p=0.001). Zurich, ACTA, Alabama generalized wear and Ivoclar (volume) had correlation coefficients between 0.3 and 0.4. For Zurich, Alabama generalized wear and Munich, the correlation coefficient improved if only composites for direct use were taken into consideration. The combination of different laboratory methods did not significantly improve the correlation. SIGNIFICANCE: The clinical wear of composite resins is mainly dependent on differences between patients and less on the differences between materials. Laboratory methods to test conventional resins for wear are therefore less important, especially since most of them do not reflect the clinical wear.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study aimed to determine the number of measurements necessary to evaluate physical and chemical characteristics of peach fruits, study the relationships between them and their direct and indirect effects on the content of ascorbic acid and total carotenoids. The characteristics skin and pulp color, fruit weight, suture, equatorial and polar diameters, firmness, soluble solids (SS), titratable acidity (TA), SS/TA ratio, ascorbic acid and total carotenoids were evaluated in 39 cultivars of peach and 3 cultivars of nectarine from the orchard of the Universidade Federal de Viçosa. The repeatability coefficient was estimated by ANOVA and CPCOR. Phenotypic correlation coefficients (rf) were estimated and, after the multicollinearity diagnostics, they were unfolded to direct and indirect effects of the explanatory variables on the response variable using path analysis. There was agreement on the magnitude of repeatability coefficients obtained by the two methods; however, they varied among the 14 characteristics. The highest correlations were found between FW, SD, ED and PD. Seven fruits are sufficient to evaluate the physical and chemical characteristics of peach with a correlation coefficient of 90%. The characteristics considered in the path diagrams (b* skin, hº skin, b* pulp, hº pulp, ED, PD, FIR, SS, SS/AT and TC) are not the main determinants of the ascorbic acid. The yellow hue of the pulp (hº pulp) has the potential to be used in indirect selection for total carotenoids.