284 resultados para XE
Resumo:
In the collision system Xe - Ag, the thresholds for excitation of quasimolecular L radiation and characteristic Ag L radiation have been found to lie at about 5 MeV and 1 MeV, respectively. These results are discussed on the basis of ab initio calculations of the screened interaction potential and the electron-correlation diagram.
Resumo:
From the concentrations of dissolved atmospheric noble gases in water, a so-called “noble gas temperature” (NGT) can be determined that corresponds to the temperature of the water when it was last in contact with the atmosphere. Here we demonstrate that the NGT concept is applicable to water inclusions in cave stalagmites, and yields NGTs that are in good agreement with the ambient air temperatures in the caves. We analysed samples from two Holocene and one undated stalagmite. The three stalagmites originate from three caves located in different climatic regions having modern mean annual air temperatures of 27 °C, 12 °C and 8 °C, respectively. In about half of the samples analysed Kr and Xe concentrations originated entirely from the two well-defined noble gas components air-saturated water and atmospheric air, which allowed NGTs to be determined successfully from Kr and Xe concentrations. One stalagmite seems to be particularly suitable for NGT determination, as almost all of its samples yielded the modern cave temperature. Notably, this stalagmite contains a high proportion of primary water inclusions, which seem to preserve the temperature-dependent signature well in their Kr and Xe concentrations. In future work on stalagmites detailed microscopic inspection of the fluid inclusions prior to noble gas analysis is therefore likely to be crucial in increasing the number of successful NGT determinations.
Resumo:
In case of violation of CPT- and Lorentz Symmetry, the minimal Standard Model Extension (SME) of Kostelecky and coworkers predicts sidereal modulations of atomic transition frequencies as the Earth rotates relative to a Lorentz-violating background field. One method to search for these modulations is the so-called clock-comparison experiment, where the frequencies of co-located clocks are compared as they rotate with respect to the fixed stars. In this work an experiment is presented where polarized 3He and 129Xe gas samples in a glass cell serve as clocks, whose nuclear spin precession frequencies are detected with the help of highly sensitive SQUID sensors inside a magnetically shielded room. The unique feature of this experiment is the fact that the spins are precessing freely, with transverse relaxation times of up to 4.4 h for 129Xe and 14.1 h for 3He. To be sensitive to Lorentz-violating effects, the influence of external magnetic fields is canceled via the weighted difference of the 3He and 129Xe frequencies or phases. The Lorentz-violating SME parameters for the neutron are determined out of a fit on the phase difference data of 7 spin precession measurements of 12 to 16 hours length. The result of the fit gives an upper limit for the equatorial component of the neutron parameter b_n of 3.7×10^(−32) GeV at the 95% confidence level. This value is not limited by the signal-to-noise ratio, but by the strong correlations between the fit parameters. To reduce the correlations and therewith improve the sensitivity of future experiments, it will be necessary to change the time structure of the weighted phase difference, which can be realized by increasing the 129Xe relaxation time.
Resumo:
In this work, the remarkable versatility and usefulness of applications of Xe-129 NMR experiments is further extended. The application of Xe-129 NMR spectroscopy to very different system is studied, including dynamic and static, solid and liquid, porous and non-porous systems. Using the large non-equilibrium polarization created by hyperpolarization of Xe-129, time-resolved NMR measurements can be used for the online-monitoring of dynamic systems. In the first part of this work, several improvements for medical applications of hyperpolarized Xe-129 are achieved and their feasibility shown experimentally. A large gain in speed and reproducibility of the accumulation process of Xe-129 as ice and an enhancement of the usable polarization in any experiment requiring prior accumulation are achieved. An enhancement of the longitudinal relaxation time of Xe-129 is realized by admixture of a buffer gas during the storage of hyperpolarized Xe-129. Pursuing the efforts of simplifying the accumulation process and enhancing the storage time of hyperpolarized Xe-129 will allow for a wider use of the hyperpolarized gas in (medical) MRI experiments. Concerning the use of hyperpolarized Xe-129 in MRI, the influence of the diffusion coefficient of the gas on parameters of the image contrast is experimentally demonstrated here by admixture of a buffer gas and thus changing the diffusion coefficient. In the second part of this work, a polymer system with unique features is probed by Xe-129 NMR spectroscopy, proving the method to be a valuable tool for the characterization of the anisotropic properties of semicrystalline, syndiotactic polystyrene films. The polymer films contain hollow cavities or channels with sizes in the sub-nanometer range, allowing for adsorption of Xe-129 and subsequent NMR measurements. Despite the use of a ’real-world’ system, the transfer of the anisotropic properties from the material to adsorbed Xe-129 atoms is shown, which was previously only known for fully crystalline materials. The anisotropic behavior towards atomar guests inside the polymer films is proven here for the first time for one of the phases. For the polymer phase containing nanochannels, the dominance of interactions between Xe-129 atoms in the channels compared to interactions between Xe atoms and the channel walls are proven by measurements of a powder sample of the polymer material and experiments including the rotation of the films in the external magnetic field as well as temperature-dependent measurements. The characterization of ’real-world’ systems showing very high degrees of anisotropy by Xe-129 are deemed to be very valuable in future applications. In the last part of this work, a new method for the online monitoring of chemical reactions has been proposed and its feasibility and validity are experimentally proven. The chemical shift dependence of dissolved Xe-129 on the composition of a reaction mixture is used for the online monitoring of free-radical miniemulsion polymerization reactions. Xe-129 NMR spectroscopy provides an excellent method for the online monitoring of polymerization reactions, due to the simplicity of the Xe-129 NMR spectra and the simple relationship between the Xe-129 chemical shift and the reaction conversion. The results of the time-resolved Xe-129 NMR measurements are compared to those from calorimetric measurements, showing a good qualitative agreement. The applicability of the new method to reactions other than polymerization reactions is investigated by the online monitoring of an enzymatic reaction in a miniemulsion. The successful combination of the large sensitivity of Xe-129, the NMR signal enhancements due to hyperpolarization, and the solubility of Xe-129 gives access to the large new field of investigations of chemical reaction kinetics in dynamic and complex systems like miniemulsions.
Resumo:
Light pseudoscalar bosons, such as the axion that was originally proposed as a solution of the strong CP problem, would cause a new spin-dependent short-range interaction. In this thesis, an experiment is presented to search for axion mediated short-range interaction between a nucleon and the spin of a polarized bound neutron. This interaction cause a shift in the precession frequency of nuclear spin-polarized gases in the presence of an unpolarized mass. To get rid of magnetic field drifts co-located, nuclear spin polarized 3He and 129Xe atoms were used. The free nuclear spin precession frequencies were measured in a homogeneous magnetic guiding field of about 350nT using LTc SQUID detectors. The whole setup was housed in a magnetically shielded room at the Physikalisch Technische Bundesanstalt (PTB) in Berlin. With this setup long nuclear spin-coherence times, respectively, transverse relaxation times of 5h for 129Xe and 53h for 3He could be achieved. The results of the last run in September 2010 are presented which give new upper limits on the scalar-pseudoscalar coupling of axion-like particles in the axion-mass window from 10^(-2) eV to 10^(-6) eV. The laboratory upper bounds were improved by up to 4 orders of magnitude.
Resumo:
Seit seiner Entdeckung im Jahre 1978 wurden für hyperpolarisiertes (HP) 129Xe zahlreiche Anwendungen gefunden. Aufgrund seiner hohen Verstärkung von NMR-Signalen wird es dabei typischerweise für Tracer- und Oberflächenstudien verwendet. Im gasförmigen Zustand ist es ein interessantes, klinisches Kontrastmittel, welches für dynamische Lungen MRT genutzt oder auch in Blut oder lipophilen Flüssigkeiten gelöst werden kann. Weiterhin findet HP-Xe auch in der Grundlagenphysik in He-Xe Co-Magnetometern Verwendung, mit welchen z. B. das elektrische Dipolmoment von Xe bestimmt werden soll, oder es dient zur Überprüfung auf Lorentz-Invarianzen. Alle diese Anwendungen profitieren von einem hohen Polarisationsgrad (PXe), um hohe Signalstärken und lange Lagerzeiten zu erreichen. rnIn dieser Arbeit wurden zwei mobile Xe-Polarisatoren konstruiert: einer für Experimente in der Grundlagenphysik mit einer Produktionsrate von 400 mbar·l/h mit PXe ≈ 5%. Der zweite Xe-Polarisator wurde für medizinische Anwendungen entwickelt und soll 1 bar l/h mit PXe > 20% erzeugen. Der letztere wurde noch nicht getestet. Die Arbeitsbedingungen des Xe-Polarisators für Grundlagenphysik (Strömung des Gasgemischs, Temperatur, Druck und Konzentration von Xe) wurden variiert, um einen höchstmöglichen Polarisationsgrad zu erzielen. Die maximale Polarisation von 5,6 % wurde bei Verwendung eine Gasmischung von 1% Xe bei einem Durchfluss von 200 ml/min, einer Temperatur von 150°C und einem Gesamtdruck von 4 bar erreicht. rnWeiterhin muss HP-Xe auch effizient gelagert werden, um Polarisationsverluste zu minimieren. Das ist besonders für solche Anwendungen notwendig, welche an einem entfernten Standort durchgeführt werden sollen oder auch wenn lange Spinkohärenzeiten gefordert sind, z.B. bei He-Xe Co-Magnetometern. rnHierbei bestand bisher die größte Schwierigkeit darin, die Reproduzierbarkeit der gemessenen Lagerzeiten sicherzustellen. In dieser Arbeit konnte die Spin-Gitter-Relaxationszeit (T1) von HP-129Xe in unbeschichteten, Rb-freien, sphärischen Zellen aus Aluminiumsilikatglas (GE-180) signifikant verbessert werden. Die T1–Zeit wurde in einem selbstgebauten Niederfeld-NMR-System (2 mT) sowohl für reines HP-Xe als auch für HP-Xe in Mischungen mit N2, SF6 und CO2 bestimmt. Bei diesen Experimenten wurde die maximale Relaxationszeit für reines Xe (85% 129 Xe) bei (4,6 ± 0,1) h festgestellt. Dabei lagen die typischen Wand-Relaxationszeiten bei ca. 18 h für Glaszellen mit einem Durchmesser von 10 cm. Des Weiteren wurde herausgefunden, dass CO2 eine unerwartet hohe Effizienz bei der Verkürzung der Lebensdauer der Xe-Xe Moleküle zeigte und somit zu einer deutlichen Verlängerung der gesamten T1-Zeit genutzt werden kann. rnIm Verlauf vieler Experimente wurde durch wiederholte Messungen mit der gleichen Zelle, ein "Alterungsprozess“ bei der Wandrelaxation identifiziert und untersucht. Dieser Effekt könnte leicht rückgängig gemacht werden, indem die anfängliche Reinigungsprozedur wiederholt wurde. Auf diese Weise kann eine konstante Wandrelaxation sichergestellt werden, durch die sehr reproduzierbare T1-Messungen möglich werden. rnSchließlich wurde die maximale Relaxationszeit für HP-Xe mit natürlicher Häufigkeit in Mischungen mit SF6 bestimmt. Überraschenderweise war dieser Wert um ca. 75% niedriger als der Wert für Xenon, das zu 85% mit 129Xe angereichert war. Dieser Effekt wurde durch drei unabhängige Experimente bestätigt, da er nicht von der bestehenden Theorie der Xe-Relaxation ableitbar ist. rnDie Polarisation von HP-Xe, PXe, wird normalerweise durch den Vergleich der NMR-Signale des HP-Xe mit einer thermischen polarisierten Probe (z. B. 1H2O oder Xe) bestimmt. Dabei beinhaltet der Vergleich unterschiedlicher Messungen an verschiedenen Proben (unterschiedlicher Druck, Signalintensität und Messverfahren) viele experimentelle Unsicherheiten, welche sich oft nicht leicht bestimmen lassen. Eine einfache, genaue und kostengünstige Methode zur Bestimmung von PXe durch eine direkte Messung der makroskopischen Magnetisierung in einem statischen Magnetfeld vermeidet alle diese Unsicherheiten. Dieses Verfahren kann Polarisationen von > 2 % mit einer Genauigkeit von maximal 10% fast ohne Polarisationsverlust bestimmen. Zusätzlich kann diese Methode ohne weitere Änderungen auch für Bestimmungen des Polarisationsgrades anderer HP-Gase verwendet werden.rn
Resumo:
Ion impact emission cross sections for eleven transitions from the 5p56p configuration to the 5p56s configuration of neutral xenon occurring in the spectral region between 700 nm and 1000 nm have been measured experimentally. Collisions between both singly- and doublyionized xenon and neutral xenon have been studied. These cross sections are of primary use in the development of a spectrographic diagnostic for Hall effect thruster plasma. A detailed discussion of the experimental methods and the subsequent data reduction is included. The results are presented and the importance of these data for spectrographic emission models of Hall effect thruster plasmas is discussed.