987 resultados para X-rays: individuals: 2XMM J104608.7-594306
Resumo:
In 2009, Cygnus X-3 (Cyg X-3) became the first microquasar to be detected in the GeV γ-ray regime, via the satellites Fermi and AGILE. The addition of this new band to the observational toolbox holds promise for building a more detailed understanding of the relativistic jets of this and other systems. We present a rich data set of radio, hard and soft X-ray, and γ-ray observations of Cyg X-3 made during a flaring episode in 2010 May. We detect a ~3 day softening and recovery of the X-ray emission, followed almost immediately by a ~1 Jy radio flare at 15 GHz, followed by a 4.3σ γ-ray flare (E > 100 MeV) ~1.5 days later. The radio sampling is sparse, but we use archival data to argue that it is unlikely the γ-ray flare was followed by any significant unobserved radio flares. In this case, the sequencing of the observed events is difficult to explain in a model in which the γ-ray emission is due to inverse Compton scattering of the companion star's radiation field. Our observations suggest that other mechanisms may also be responsible for γ-ray emission from Cyg X-3.
Resumo:
The microquasar 1E 1740.7-2942 is a source located in the direction of the Galactic Center. It has been detected at X-rays, soft gamma-rays, and in the radio band, showing an extended radio component in the form of a double-sided jet. Although no optical counterpart has been found so far for 1E 1740.7-2942, its X-ray activity strongly points to a galactic nature. Aims.We aim to improve our understanding of the hard X-ray and gamma-ray production in the system, exploring whether the jet can emit significantly at high energies under the light of the present knowledge. Methods.We have modeled the source emission, from radio to gamma-rays, with a cold-matter dominated jet model. INTEGRAL data combined with radio and RXTE data, as well as EGRET and HESS upper-limits, are used to compare the computed and the observed spectra. Results.From our modeling, we find out that jet emission cannot explain the high fluxes observed at hard X-rays without violating at the same time the constraints from the radio data, favoring the corona origin of the hard X-rays. Also, 1E 1740.7-2942 might be detected by GLAST or AGILE at GeV energies, and by HESS and HESS-II beyond 100 GeV, with the spectral shape likely affected by photon-photon absorption in the disk and corona photon fields.
Resumo:
The Tradescantia micronucleus test is a sensitive bioassay for mutagenesis that may be employed both under field and laboratory conditions. This test has been standardized mostly on the basis of the results obtained with clone 4430. However, this clone is not well adapted to tropical weather, frequently showing problems with growth and flowering. In addition, it is attacked by parasites and insects, a fact that limits its use in field studies aiming at the biomonitoring of air pollution. In the city of São Paulo, Tradescantia pallida (Rose) Hunt. var. purpurea Boom is widely distributed as an ornamental plant in gardens and along roadsides and streets, mostly because of its natural resistance and its easy propagation. In this report, we present dose-response curves indicating that the sensitivity of T. pallida and clone 4430 to X-radiation (1, 10, 25 and 50 cGy) is similar. The results confirm our previous suggestion that T. pallida represents a good alternative for in situ mutagenesis testing in tropical regions, especially biomonitoring studies in which the exposure conditions may not be fully controllable.
Resumo:
The objective of the present study was to evaluate the efficiency of X-rays in identifying fissures in artificially dried rice seeds and the relationship between damage and seed performance in the germination test. Irrigated rice seeds of the IRGA 417 and IRGA 420 cultivars were harvested with 23.3 and 24.5% water content respectively and submitted to stationary drying treatments at 32, 38, 44 and 50 °C. X-rays were taken of subsamples of 100 seeds for each treatment, using an MX-20 X-ray equipment. The X-rayed seeds were classified from 1 to 3, where 1 corresponded to seeds without fissures, 2 to seeds with non-severe fissures and 3 to seeds with severe fissures. The same X-rayed seeds were planted and on the seventh day the seedlings (normal or abnormal) and dead seeds were photographed and evaluated to verify any relationship between the fissures and physiological potential. Higher drying temperature increased the percentage of fissures in the two cultivars, which can adversely affect their germination. Seeds with fissures can be identified using X-rays.
Resumo:
Using a relativistic selfconsistent correlation diagram a first interpretation of the shape and position of L MO X-rays is given within a quasi-adiabatic model.
Resumo:
The result of the first calculation of a self-consistent relativistic many electron correlation diagram ever done (for the system Au - I) leads to a good agreement of the spectral shape and position of the observed noncharacteristic X-rays within the quasi adiabatic model.
Resumo:
For the angular dependence of quasimolecular X-ray emission in heavy ion colliding systems we present a semiclassical adiabatic model taking into account spontaneous dipole radiation. Using the most characteristic levels from a DFS-correlation diagram we are able to explain the behaviour of the observed anisotropy.
Resumo:
Quasi-molecular X-rays observed in heavy ion collisions are interpreted within a relativistic calculation of correlation diagrams using the Dirac-Slater model. A semiquantitative description of noncharacteristic M X rays is given for the system Au-I.
Resumo:
Platinum is one of the most common coatings used to optimize mirror reflectivity in soft X-ray beamlines. Normal operation results in optics contamination by carbon-based molecules present in the residual vacuum of the beamlines. The reflectivity reduction induced by a carbon layer at the mirror surface is a major problem in synchrotron radiation sources. A time-dependent photoelectron spectroscopy study of the chemical reactions which take place at the Pt(111) surface under operating conditions is presented. It is shown that the carbon contamination layer growth can be stopped and reversed by low partial pressures of oxygen for optics operated in intense photon beams at liquidnitrogen temperature. For mirrors operated at room temperature the carbon contamination observed for equivalent partial pressures of CO is reduced and the effects of oxygen are observed on a long time scale.
Resumo:
X-ray irradiation is shown to affect electronic properties of polyaniline (PANi) in composite Langmuir-Blodgett (LB) films of PANi and cadmium stearate, in a similar way to acid doping. The time it takes for the shift in the UV-vis spectra, characteristic of PANi doping, increases linearly with the film thickness, thus indicating a surface-controlled process. The humidity of the environment under which the films are irradiated is also of extreme importance. No shin is observed under vacuum or under dry atmospheres of N-2, O-2 and Ar. For humid environments the time for the shift decreases with increasing relative humidity.
Resumo:
This paper describes two simple thermal methods for measuring the energy fluence in J/cm 2 from a diagnostic x-ray exposure. Both detectors absorb essentially 100% of the radiation and give a signal that is directly proportional to the energy fluence of the x-ray beam. One detector measures the thermal effect when a pulse of x rays is totally absorbed in the pyroelectric detector of lead-zirconium-titanate (PZT). The other detector measures the expansion of a gas surrounding a lead disk detector in a photoacoustic chamber. The increased pressure of the gas is transmitted through a 1-mm duct to a sensitive microphone. Both detectors have previously been used to measure the energy fluence rate of continuous x-ray beams in the same energy region using a chopped beam and a lock-in amplifier. Measurement of the energy fluence of a pulse of radiation eliminates the need for the beam chopper and lock-in amplifier and results in a simple, rugged, and inexpensive dosimeter. Either method can be combined with the area of the beam to give an estimate of the imparted energy to the patient from a diagnostic x-ray exposure.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this work we have studied the radiation effects on MOSFET electronic devices. The integrated circuits were exposed to 10 key X-ray radiation and 2.6 MeV energy proton beam. We have irradiated MOSFET devices with two different geometries: rectangular-gate transistor and circular-gate transistor. We have observed the cumulative dose provokes shifts on the threshold voltage and increases or decreases the transistor's off-state and leakage current. The position of the trapped charges in modern CMOS technology devices depends on radiation type, dose rate, total dose, applied bias and is a function of device geometry. We concluded the circular-gate transistor is more tolerant to radiation than the rectangular-gate transistor. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The objective of the present study was to evaluate the efficiency of X-rays in identifying fissures in artificially dried rice seeds and the relationship between damage and seed performance in the germination test. Irrigated rice seeds of the IRGA 417 and IRGA 420 cultivars were harvested with 23.3 and 24.5% water content respectively and submitted to stationary drying treatments at 32, 38, 44 and 50 °C. X-rays were taken of subsamples of 100 seeds for each treatment, using an MX-20 X-ray equipment. The X-rayed seeds were classified from 1 to 3, where 1 corresponded to seeds without fissures, 2 to seeds with non-severe fissures and 3 to seeds with severe fissures. The same X-rayed seeds were planted and on the seventh day the seedlings (normal or abnormal) and dead seeds were photographed and evaluated to verify any relationship between the fissures and physiological potential. Higher drying temperature increased the percentage of fissures in the two cultivars, which can adversely affect their germination. Seeds with fissures can be identified using X-rays.