977 resultados para WATER SOURCES
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Economics from the NOVA – School of Business and Economics
Resumo:
Dissertation presented to obtain the Ph.D degree in Engineering and Technology Sciences, Chemical Engineering.
Resumo:
Quantitative method of viral pollution determination for large volume of water using ferric hydroxide gel impregnated on the surface of glassfibre cartridge filter. The use of ferric hydroxide gel, impregnated on the surface of glassfibre cartridge filter enable us to recover 62.5% of virus (Poliomylitis type I, Lsc strain) exsogeneously added to 400 liters of tap-water. The virus concentrator system consists of four cartridge filters, in which the three first one are clarifiers, where the contaminants are removed physically, without significant virus loss at this stage. The last cartridge filter is impregnated with ferric hydroxide gel, where the virus is adsorbed. After the required volume of water has been processed, the last filter is removed from the system and the viruses are recovered from the gel, using 1 liter of glycine/NaOH buffer, at pH 11. Immediately the eluate is clarified through series of cellulose acetate membranes mounted in a 142mm Millipore filter. For the second step of virus concentration, HC1 1N is added slowly to the eluate to achieve pH 3.5-4. MgC1, is added to give a final concentration of 0.05M and the viruses are readsorbed on a 0.45 , porosity (HA) cellulose acetate membrane, mounted in a 90 mm Millipore filter. The viruses are recovered using the same eluent plus 10% of fetal calf serum, to a final volume of 3 ml. In this way, it was possible to concentrate virus from 400 liters of tap-water, into 1 liter in the first stage of virus concentration and just to 3 ml of final volume in a second step. The efficiency, simplicity and low operational cost, provded by the method, make it feasible to study viral pollution of recreational and tap-water sources.
Resumo:
Prevention of acid mine drainage (AMD) in sulfide-containing tailings requires the identification of the geochemical processes and element pathways in the early stages of tailing deposition. However, analyses of recently deposited tailings in active tailings impoundments are scarce because mineralogical changes occur near the detection limits of many assays. This study shows that a detailed geochemical study which includes stable isotopes of water (delta H-2, delta O-18), dissolved sulfates (delta S-34, delta O-18) and hydrochernical parameter (pH, Eh, DOC, major and trace elements) from tailings samples taken at different depths in rainy and dry seasons allows the understanding of weathering (oxidation, dissolution, sorption, and desorption), water and element pathways, and mixing processes in active tailings impoundments. Fresh alkaline tailings (pH 9.2-10.2) from the Cu-Mo porphyry deposit in El Teniente, Chile had low carbonate (0.8-1.1 Wt-% CaCO3 equivalent) and sulfide concentrations (0.8-1.3 wt.%, mainly as pyrite). In the alkaline tailings water, Mo and Cu (up to 3.9 mg/L Mo and 0.016 mg/L Cu) were mobile as MoO42- and Cu (OH)(2)(0). During the flotation, tailings water reached equilibrium with gypsum (up to 738 mg/L Ca and 1765 mg/ L SO4). The delta S-34 VS. delta O-18 covariations of dissolved sulfate (2.3 to 4.5% delta S-34 and 4.1 to 6.0 % delta O-18) revealed the sulfate sources: the dissolution of primary sulfates (12.0 to 13.2%. delta S-34, 7.4 to 10.9%.delta O-18) and oxidation of primary sulfides (-6.7 to 1.7%. delta S-34). Sedimented tailings in the tailings impoundment can be divided into three layers with different water sources, element pathways, and geochemical processes. The deeper sediments (> 1 m depth) were infiltrated by catchment water, which partly replaced the original tailings water, especially during the winter season. This may have resulted in the change from alkaline to near-neutral pH and towards lower concentrations of most dissolved elements. The neutral pH and high DOC (up to 99.4 mg/L C) of the catchment water mobilized Cu (up to 0.25 mg/L) due to formation of organic Cu complexes; and Zn (up to 130 mg/L) due to dissolution of Zn oxides and desorption). At I m depth, tailings pore water obtained during the winter season was chemically and isotopically similar to fresh tailings water (pH 9.8-10.6, 26.7-35.5 mg/L Cl, 2.3-6.0 mg/L Mo). During the summer, a vadose zone evolved locally and temporarily up to 1.2 m depth. resulting in a higher concentration of dissolved solids in the pore water due to evaporation. During periodical new deposition of fresh tailings, the geochemistry of the surface layer was geochemically similar to fresh tailings. In periods without deposition, sulfide oxidation was suggested by decreasing pH (7.7-9.5), enrichment of MoO42- and SO42-, and changes in the isotopic composition of dissolved sulfates. Further enrichment for Na, K, Cl, SO4, Mg, Cu, and Mo (up to 23.8 mg/L Mo) resulted from capillary transport towards the surface followed by evaporation and the precipitation of highly soluble efflorescent salts (e.g., mirabilite, syngenite) at the tailing surface during summer. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
One way of classifying water quality is by means of indices, in which a series of parameters analyzed are joined a single value, facilitating the interpretation of extensive lists of variables or indicators, underlying the classification of water quality. The objective of this study was to develop a statistically based index to classify water according to the Irrigation Water Quality Index (IWQI), to evaluate the ionic composition of water for use in irrigation and classify it by its source. For this purpose, the database generated during the Technology Generation and Adaptation (GAT) program was used, in which, as of 1988, water samples were collected monthly from water sources in the states of Paraíba, Rio Grande do Norte and Ceará. To evaluate water quality, the electrical conductivity (EC) of irrigation water was taken as a reference, with values corresponding to 0.7 dS m-1. The chemical variables used in this study were: pH, EC, Ca, Mg, Na, K, Cl, HCO3, CO3, and SO4. The data of all characteristics evaluated were standardized and data normality was confirmed by Lilliefors test. Then the irrigation water quality index was determined by an equation that relates the standardized value of the variable with the number of characteristics evaluated. Thus, the IWQI was classified based on indices, considering normal distribution. Finally, these indices were subjected to regression analysis. The method proposed for the IWQI allowed a satisfactory classification of the irrigation water quality, being able to estimate it as a function of EC for the three water sources. Variation in the ionic composition was observed among the three sources and within a single source. Although the water quality differed, it was good in most cases, with the classification IWQI II.
Resumo:
Solving the water crisis in the developing world is a critical issue. Four billion people in the globe, so called the Base of the Pyramid (BoP) population suffer from inadequate access to safe drinking water, while millions die daily from waterborne diseases and lack of clean water. The BoP people desperately need to obtain a satisfactory access to safe water sources. In order to address the issue, this research has been carried out. To provide holistic consideration to the matter, comprehensive exploration of various causes of the water crisis and its impacts in developing countries were discussed. Then, various viable and relevant solutions to the problem have been thoroughly scrutinized, including scientific, rational, practical and speculative approaches, examination of existing methods, technologies and products at the BoP water market. The role of clean water to the sustainable development was specifically featured. The paper also has studied social and economic factors, actors and circumstances which affect the market development of clean water technologies in the BoP. Possibilities and potentials of successful business between foreign water enterprises and BoP consumers were considered, while primary obstacles are deliberated on, with suggestion of the ways to tackle them. Technologies and products which are needed by the poor must be affordable, sustainable and of an appropriate quality. The crucial question of technology transfer was soundly discussed with pointing out main hindrances on the way of its implementation between the developed and developing world. The means to overcome these barriers were properly observed as well. To explore to some extent the possibility and feasibility of technology transfer from Finland to the BoP sector, 3 case study analyses have been implemented. Personal discussions in form of interviews were conducted at Kemira, Outotec and Fenno Water, Finnish water treatment and supply enterprises. The results of the interviews shed light on the specific practical matters, actual obstacles and potential solutions of the technology transfer from Finland to low-income countries.
Resumo:
The tiniest Union territory of India, Lakshadweep, is an archipelago, with an area of 32 Sq. km. consisting of 12 atolls, three reefs and five submerged banks, lies between 8° and 12°30'N latitudes and 71° and 74" E longitudes. It is one of the most important and critical territories of India from economic and defence point of view. Specialised environment having typical geological set up, Lakshadweep is ecologically sensitive to even slight climatic or anthropogenic interference. Pollution of coastal seas, over exploitation and contamination of the fresh water sources are thus become great concerns to the existence of the island. Typical geological set up and interference cause threat to the ecology of the fragile environment and resources of the island as well as its resources. Marine pollution and ground water contamination are concerns in this regard. Even though attentions were made to assess the physico—chemical and bacteriological status of the marine and groundwater systems separately, an integrated approach has not been evolved. The present study with its broad objectives is attempted for an integrated assessment of microbiological, physicochemical and biological characteristics of the surrounding seawater and microbiological and physico—chemical characteristics of the ground water in Kavaratti island. The entire study has been organised in 4 chapters
Resumo:
The rivers are considered as the life line of any country since they make water available for our domestic, industrial and recreational functions. The quality of river water signifies the health status and hygienic aspects of a particular region, but the quality of these life lines is continuously deteriorating due to discharge of sewage, garbage and industrial effluents into them. Thrust on water demand has increased manifolds due to the increased population, therefore tangible efforts to make the water sources free from pollution is catching attention all across the globe. This paper attempts to highlight the trends in water quality change of River Beas, right from Manali to Larji in India. This is an important river in the state of Himachal Pradesh and caters to the need of water for Manali and Kullu townships, besides other surrounding rural areas. The Manali-Larji Beas river stretch is exposed to the flow of sewage, garbage and muck resulting from various project activities, thereby making it vulnerable to pollution. In addition, the influx of thousands of tourists to these towns also contributes to the pollution load by their recreational and other tourist related activities. Pollution of this river has ultimately affected the livelihood of local population in this region. Hence, water quality monitoring was carried out for the said stretch between January, 2010 and January, 2012 at 15 various locations on quarterly basis, right from the upstream of Manali town and up to downstream of Larji dam. Temperature, color, odor, D.O. , pH, BOD, TSS, TC and FC has been the parameters that were studied. This study gives the broad idea about the characteristics of water at locations in the said river stretch, and suggestions for improving water quality and livelihood of local population in this particular domain.
Resumo:
An investigation into the speciation and occurrence of nine haloacetic acids (HAAs) was conducted during the period of April 2007 to March 2008 and involved three drinking water supply systems in England, which were chosen to represent a range of source water conditions; these were an upland surface water, a lowland surface water and a groundwater. Samples were collected seasonally from the water treatment plants and at different locations in the distribution systems. The highest HAA concentrations occurred in the upland surface water system, with an average total HAA concentration of 21.3 μg/L. The lowest HAA levels were observed in the groundwater source, with a mean concentration of 0.6 μg/L. Seasonal variations were significant in the HAA concentrations; the highest total HAA concentrations were found during the autumn, when the concentrations were approximately two times higher than in winter and spring. HAA speciation varied among the water sources, with dichloroacetic acid and trichloroacetic acid dominant in the lowland surface water system and brominated species dominant in the upland surface water system. There was a strong correlation between trihalomethanes and HAAs when considering all samples from the three systems in the same data set (r2=0.88); however, the correlation was poor/moderate when considering each system independently.
Resumo:
Acanthamoeba spp., known to cause keratitis and granulomatous encephalitis in humans, are frequently isolated from a variety of water sources. Here we report for the first time the characterization of an Acanthamoeba sp. (ACC01) isolated from tap water in Brazil. This organism is currently being maintained in an axenic growth medium. Phylogenetic analysis based on SSU rRNA gene sequences positioned the new isolate in genotype T4, closest to the keratitis-causing isolate, A. polyphaga ATCC 30461 (similar to 99% similarity). Acanthamoeba ACC01 and A. polyphaga 30461 both grew at 37 degrees C and were osmotically resistant, multiplying in hyperosmolar medium. Both isolates secreted comparable amounts of proteolytic enzymes, including serine peptidases that were optimally active at a near neutral/alkaline pH and resolved identically in gelatin gels. Incubation of gels at pH 4.0 with 2 mM DTT also indicated the secretion of similar cysteine peptidases. Altogether, the results point to the pathogenic potential of Acanthamoeba ACC01. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
A high incidence of waterborne diseases is observed worldwide and in order to address contamination problems prior to an outbreak, quantitative microbial risk assessment is a useful tool for estimating the risk of infection. The objective of this paper was to assess the probability of Giardia infection from consuming water from shallow wells in a peri-urban area. Giardia has been described as an important waterborne pathogen and reported in several water sources, including ground waters. Sixteen water samples were collected and examined according to the US EPA (1623, 2005). A Monte Carlo method was used to address the potential risk as described by the exponential dose response model. Giardia cysts occurred in 62.5% of the samples (0.1-36.1 cysts/l). A median risk of 10-1 for the population was estimated and the adult ingestion was the highest risk driver. This study illustrates the vulnerability of shallow well water supply systems in peri-urban areas.
Resumo:
Aims: To determine the species, bio-sero-phagetypes, antimicrobial drug resistance and also the pathogenic potential of 144 strains of Yersinia spp. isolated from water sources and sewage in Brazil.Methods and Results: the 144 Yersinia strains were characterized biochemically, serologically and had their antibiotic resistance and phenotypic virulence markers determined by microbiological and serological standard techniques. The Y. enterocolitica strains related to human diseases were also tested for the presence of virulence genes, by the PCR technique. The isolates were classified as Y. enterocolitica, Y. intermedia, Y. frederiksenii, Y. kristensenii and Yersinia biochemically atypical. The 144 isolates belonged to various bio-serogroups. Half of the strains showed resistance to three or more drugs. The Y. enterocolitica strains related to human diseases exhibited phenotypic virulence characteristics and virulence genes.Conclusions: Water from various sources and sewage are contaminated with Yersinia spp. in Brasil. Among these bacteria, virulent strains of Y. enterocolitica were found, with biotypes and serogroups related to human diseases.Significance and Impact of the Study: This is the first documented description of the occurrence of pathogenic Y. enterocolitica in water sources and sewage in Brazil. The occurrence of virulence strains of Y. enterocolitica shows that the environment is a potential source of human infection by this species in this country.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Leakage in buried pipes is one of the main concerns for water companies due to the scarcity of potable water sources. Older metallic pipelines have been replaced by plastic pipes in such systems, which makes it more difficult to locate leaks using acoustics and vibration. This is mainly because of the high attenuation of leak signals caused by the damping in the pipe wall. To investigate acoustic methods in leak location in controlled conditions, a bespoke test rig was constructed in the UK. In this paper, data from this test-rig is used to discuss some issues that arise when using two contemporary correlators. Of particular interest, is the way in which a resonance in the system can have a profound effect on the estimate of the position of the leak depending on the way in which the leak noise signals are processed. © (2013) Trans Tech Publications.