941 resultados para Vertical axis
Resumo:
As advances in numerical modelling techniques support the increased confidence in predictions from computer simulations, the need remains to have experimental verification built into the design process. This paper outlines the experimental investigation carried out on a shielded vertical axis turbine in a marine environment. The experiments consist of performance measurements and the use of particle image velocimetry on a small scale device in a marine current flume. The results demonstrate that the performance of the device can be modelled numerically; in particular, the results show that the numerical model used can correctly predict the increase in performance with Reynolds number.
Resumo:
Drawing on ethnographic data collected while working as a deckhand on two Scottish trawlers, this article analyses the spatialisation of social, religious and economic inequalities that marked relations between crew members while they hunted for prawns in the North Sea. Moreover, it explores these inequalities as a wider feature of life in Gamrie, Aberdeenshire, a Brethren and Presbyterian fishing village riven by disparities in wealth and religion. Inequalities identified by fishermen at sea mirrored those identified by residents onshore, resulting in fishing boats being experienced as small 'floating villages'. Drawing on the work of Rodney Needham, this article suggests that these asymmetries can be traced along a vertical axis, with greater to lesser wealth and religiosity moving from top/above to bottom/below. The article seeks to understand the presence and persistence of these hierarchies at sea and on land, by revisiting dual classification within anthropological theory.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Este proyecto trata de completar un estudio sobre la viabilidad de una instalación de turbina de eje vertical, en una azotea de un edificio de 6 plantas en el centro de la ciudad de Madrid. Está basado en la comunidad de vecinos de la calle de Lagasca 106 de Madrid, y se realiza de forma global, con objeto de que sirva como ejemplo a futuros estudios a realizar en esta área, incluyendo todas las dificultades y problemas que este tipo de proyectos muestran en su viabilidad. Los aspectos que vamos a abordar son: Demostración de que una turbina de eje vertical es más indicada e idónea para estos casos que una turbina de eje horizontal. Capacidad de generación eléctrica de la instalación que proponemos. Problemas asociados con la actual legislación. Problemas relacionados con la instalación eléctrica: el inversor de corriente, la decisión de utilizar un sistema de baterías, conectar el aerogenerador a la red o buscar un sistema mixto. La viabilidad económica de la instalación. ABSTRACT This project tries to complete a study on the viability of a vertical axis turbines installation in the roof of a “standard” 6 floors building in the center of Madrid. Besides, the project is based on the building situated in Lagasca 106, it pretends to be done in a “global” mode, in order to be an example of future projects, and include as many usual problems and items that this kind of projects could have to afford. These problems and issues are: the substantiation of the choice of the vertical axis turbine instead of a usual horizontal axis turbine, the model and the power capacity of this turbine. The turbines installation energy saving capacity. Problems associated to the legislation that we may to afford. And problems related to the electric installation, such us, transformer associated to the turbine, the decision of link the turbine with batteries or joining it directly to the building electric system. Also we have to set a programming system in order to monitor the different situations that the turbine has to work
Resumo:
Este trabalho apresenta e compara alguns meios para o estudo do comportamento dinâmico de uma lavadora de roupas de eixo vertical durante o processo de extração de água das roupas, também conhecido como centrifugação. Os três métodos utilizados para estudar o comportamento dinâmico de uma lavadora de roupas de eixo vertical foram: analítico, experimental e simulação através de multicorpos. O interesse nesta etapa é devido ao fato dos problemas de vibração de uma lavadora ocorrerem principalmente durante a centrifugação. A modelagem de uma lavadora de roupas durante a etapa de centrifugação permite a obtenção de seu comportamento dinâmico bem como de suas principais características. Um outro tópico estudado neste trabalho foi o fenômeno de deslocamento da lavadora, um dos principais motivos de reclamação dos usuários de lavadoras de roupa automáticas.
Resumo:
Background: Measurement accuracy is critical for biomechanical gait assessment. Very few studies have determined the accuracy of common clinical rearfoot variables between cameras with different collection frequencies. Research question: What is the measurement error for common rearfoot gait parameters when using a standard 30Hz digital camera compared to 100Hz camera? Type of study: Descriptive. Methods: 100 footfalls were recorded from 10 subjects ( 10 footfalls per subject) running on a treadmill at 2.68m/s. A high-speed digital timer, accurate within 1ms served as an external reference. Markers were placed along the vertical axis of the heel counter and the long axis of the shank. 2D coordinates for the four markers were determined from heel strike to heel lift. Variables of interest included time of heel strike (THS), time of heel lift (THL), time to maximum eversion (TMax), and maximum rearfoot eversion angle (EvMax). Results: THS difference was 29.77ms (+/- 8.77), THL difference was 35.64ms (+/- 6.85), and TMax difference was 16.50ms (+/- 2.54). These temporal values represent a difference equal to 11.9%, 14.3%, and 6.6% of the stance phase of running gait, respectively. EvMax difference was 1.02 degrees (+/- 0.46). Conclusions: A 30Hz camera is accurate, compared to a high-frequency camera, in determining TMax and EvMax during a clinical gait analysis. However, relatively large differences, in excess of 12% of the stance phase of gait, for THS and THL variables were measured.
Resumo:
In this study, we evaluated agreement among three generations of ActiGraph (TM) accelerometers in children and adolescents. Twenty-nine participants (mean age = 14.2 +/- 3.0 years) completed two laboratory-based activity sessions, each lasting 60 min. During each session, participants concurrently wore three different models of the ActiGraph (TM) accelerometers (GT1M, GT3X, GT3X+). Agreement among the three models for vertical axis counts, vector magnitude counts, and time spent in moderate-to-vigorous physical exercise (MVPA) was evaluated by calculating intraclass correlation coefficients and Bland-Altman plots. The intraclass correlation coefficient for total vertical axis counts, total vector magnitude counts, and estimated MVPA was 0.994 (95% CI = 0.989-0.996), 0.981 (95% CI = 0.969-0.989), and 0.996 (95% CI = 0.989-0.998), respectively. Inter-monitor differences for total vertical axis and vector magnitude counts ranged from 0.3% to 1.5%, while inter-monitor differences for estimated MVPA were equal to or close to zero. On the basis of these findings, we conclude that there is strong agreement between the GT1M, GT3X, and GT3X+ activity monitors, thus making it acceptable for researchers and practitioners to use different ActiGraph (TM) models within a given study.
Resumo:
Osseointegration has been introduced in the orthopaedic surgery in the 1990’s in Gothenburg (Sweden). To date, there are two frequently used commercially available human implants: the OPRA (Integrum, Sweden) and ILP (Orthodynamics, Germany) systems. The rehabilitation program with both systems include some form of static load bearing exercises. These latter involved following a load progression that is monitored by the bathroom scale, providing only the load applied on the vertical axis. The loading data could be analysed through different biomechanical variables. For instance, the load compliance, corresponding to the difference between the load recommended (LR) and the load actually applied on the implant, will be presented here.
Resumo:
Background Physical conditions through gait and other functional task are parameters to consider for frailty detection. The aim of the present study is to measure and describe the variability of acceleration, angular velocity and trunk displacement in the ten meter Extended Timed Get-Up-and-Go test in two groups of frail and non-frail elderly people through instrumentation with the iPhone4® smartphone. Secondly, to analyze the differences and performance of the variance between the study groups (frail and non-frail). This is a cross-sectional study of 30 subjects aged over 65 years, 14 frail subjects and 16 non-frail subjects. Results The highest difference between groups in the Sit-to-Stand and Stand-to-Sit subphases was in the y axis (vertical vector). The minimum acceleration in the Stand-to-Sit phase was -2.69 (-4.17 / -0.96) m/s2 frail elderly versus -8.49 (-12.1 / -5.23) m/s2 non-frail elderly, p < 0.001. In the Gait Go and Gait Come subphases the biggest differences found between the groups were in the vertical axis: -2.45 (-2.77 /-1.89) m/s2 frail elderly versus -5.93 (-6.87 / -4.51) m/s2 non-frail elderly, p < 0.001. Finally, with regards to the turning subphase, the statistically significant differences found between the groups were greater in the data obtained from the gyroscope than from the accelerometer (the gyroscope data for the mean maximum peak value for Yaw movement angular velocity in the frail elderly was specifically 25.60°/s, compared to 112.8°/s for the non-frail elderly, p < 0.05). Conclusions The inertial sensor fitted in the iPhone4® is capable of studying and analyzing the kinematics of the different subphases of the Extended Timed Up and Go test in frail and non-frail elderly people. For the Extended Timed Up and Go test, this device allows more sensitive differentiation between population groups than the traditionally used variable, namely time.
Resumo:
This study investigated questions related to half-occlusion processing in human stereoscopic vision: (1) How does the depth location of a half-occluding figure affect the depth localization of adjacent monocular objects? (2) Is three-dimensional slant around vertical axis (geometric effect) affected by half-occlusion constraints? and (3) How the half-occlusion constraints and surface formation processes are manifested in stereoscopic capture? Our results showed that the depth localization of binocular objects affects the depth localization of discrete monocular objects. We also showed that the visual system has a preference for a frontoparallel surface interpretation if the half-occlusion configuration allows multiple interpretation alternatives. When the surface formation was constrained by textures, our results showed that a process of rematching spreading determines the resulting perception and that the spreading can be limited by illusory contours that support the presence of binocularly unmatched figures. The unmatched figures could be present, if the inducing figures producing the illusory surface contained binocular image differences that provided cues for quantitative da Vinci stereopsis. These findings provide evidence of the significant role of half-occlusions in stereoscopic processing.
Resumo:
PURPOSE To develop and test decision tree (DT) models to classify physical activity (PA) intensity from accelerometer output and Gross Motor Function Classification System (GMFCS) classification level in ambulatory youth with cerebral palsy (CP); and 2) compare the classification accuracy of the new DT models to that achieved by previously published cut-points for youth with CP. METHODS Youth with CP (GMFCS Levels I - III) (N=51) completed seven activity trials with increasing PA intensity while wearing a portable metabolic system and ActiGraph GT3X accelerometers. DT models were used to identify vertical axis (VA) and vector magnitude (VM) count thresholds corresponding to sedentary (SED) (<1.5 METs), light PA (LPA) (>/=1.5 and <3 METs) and moderate-to-vigorous PA (MVPA) (>/=3 METs). Models were trained and cross-validated using the 'rpart' and 'caret' packages within R. RESULTS For the VA (VA_DT) and VM decision trees (VM_DT), a single threshold differentiated LPA from SED, while the threshold for differentiating MVPA from LPA decreased as the level of impairment increased. The average cross-validation accuracy for the VC_DT was 81.1%, 76.7%, and 82.9% for GMFCS levels I, II, and III, respectively. The corresponding cross-validation accuracy for the VM_DT was 80.5%, 75.6%, and 84.2%, respectively. Within each GMFCS level, the decision tree models achieved better PA intensity recognition than previously published cut-points. The accuracy differential was greatest among GMFCS level III participants, in whom the previously published cut-points misclassified 40% of the MVPA activity trials. CONCLUSION GMFCS-specific cut-points provide more accurate assessments of MVPA levels in youth with CP across the full spectrum of ambulatory ability.
Resumo:
ZLI-1167 is a ternary mixture of nematic liquid crystals with negative diamagnetic anisotropy. It has, therefore, been used as a solvent where the spinning of the samples around the vertical axis in the conventional electromagnets without destroying the orientation of the dissolved molecules is possible in NMR experiments. This results in sharp lines with widths up to 1 Hz in the spectra.1,2 In an NMR system using a superconducting magnet (where the magnetic field direction is along the axis of spinning of the sample), it is possible to use even the nematic liquid crystals with positive diamagnetic anisotropy such as N-(p'-methoxybenzylidene)-p-n-butylaniline (MBBA) or N-(p'-ethoxybenzylidene)-p-n-butylaniline (EBBA) to obtain the spectra with sample spinning with equally sharp lines.3 The orientational behaviour of the dissolved molecules as a function of relative concentrations of the two solvents is investigated and the results are reported in the present communication.
Resumo:
In this paper, a single-story, bilinear-hysteretic structure, square in plan and supported on four columns, subjected to two horizontal ground motions is studied. The model is assumed to possess three degrees of freedom, viz., translational displacements along the two horizontal orthogonal directions and a rotation about the vertical axis. Interaction of the bending moments in the two perpendicular directions has been considered.
Resumo:
This paper addresses the problem of determining an optimal (shortest) path in three dimensional space for a constant speed and turn-rate constrained aerial vehicle, that would enable the vehicle to converge to a rectilinear path, starting from any arbitrary initial position and orientation. Based on 3D geometry, we propose an optimal and also a suboptimal path planning approach. Unlike the existing numerical methods which are computationally intensive, this optimal geometrical method generates an optimal solution in lesser time. The suboptimal solution approach is comparatively more efficient and gives a solution that is very close to the optimal one. Due to its simplicity and low computational requirements this approach can be implemented on an aerial vehicle with constrained turn radius to reach a straight line with a prescribed orientation as required in several applications. But, if the distance between the initial point and the straight line to be followed along the vertical axis is high, then the generated path may not be flyable for an aerial vehicle with limited range of flight path angle and we resort to a numerical method for obtaining the optimal solution. The numerical method used here for simulation is based on multiple shooting and is found to be comparatively more efficient than other methods for solving such two point boundary value problem.